RESUMEN
In this work, a post-synthetic modification strategy was attempted to improve the performance of the probe for sulfite detection. The assembled platform UiO-66-NH-DQA, which was acquired by anchoring the sulfite-response fluorescent probe DQA onto the surface of UiO-66-NH2via amide covalent bonds, exhibited enhanced fluorescence intensity and practical intracellular imaging capability. In spite of the structural similarity, as verified by characterization tests, the conversion rate of post-synthetic modification was calculated as 35%, equaling an approximate assembly ratio of 1 : 2 between UiO-66-NH2 and DQA. Most significantly, conversion into UiO-66-NH-DQA led to a 5.6-fold enhancement in the reporting signal with a red shift of 20 nm. For sulfite detection, the linear range was 0-150 µM, with a limit of detection value of 0.025 µM. UiO-66-NH-DQA retained advantages including high stability (within pH 5.0-9.0), rapid response (within 15 min) and high selectivity. Based on low cytotoxicity and relatively rapid cellular uptake, UiO-66-NH-DQA achieved the imaging of both the exogenous and endogenous sulfite levels in living cells. In particular, its rapid cell-permeating capability was guaranteed during the modification. The post-synthetic modification strategy reported herein has potential for improving the practical properties of fluorescent monitoring materials.
RESUMEN
Copper ions, implicated in processes such as oxidative stress and inflammation, are believed to play a crucial role in cardiovascular disease, a prevalent and deadly disease. Despite this, current diagnostic methods fail to detect early stage cardiovascular disease or track copper ion accumulation, limiting our understanding of the disease's progression. Therefore, the development of noninvasive techniques to image copper ions in cardiovascular disease is urgently needed to enhance diagnostic precision and therapeutic strategies. In this study, we report the successful synthesis and application of a copper ion-activated photoacoustic probe, CS-Cu, which exhibits high sensitivity and selectivity toward copper ions both in vitro and in vivo. CS-Cu was able to noninvasively monitor the changes in copper ion levels and differentiate between different mice based on copper ions in urine. Furthermore, the probe demonstrated good photoacoustic stability and exhibited no significant toxicity in the mice. These findings suggest that CS-Cu could be a promising tool for early detection and monitoring of Cu2+ levels in vivo and urine, providing a new perspective on the role of copper ions in cardiovascular disease.
Asunto(s)
Enfermedades Cardiovasculares , Cobre , Técnicas Fotoacústicas , Cobre/química , Cobre/orina , Animales , Técnicas Fotoacústicas/métodos , Ratones , Humanos , Iones , Rayos InfrarrojosRESUMEN
Hepatocellular carcinoma (HCC) seriously threatens the human health. Previous investigations revealed that γ-glutamyltranspeptidase (GGT) was tightly associated with the chronic injury, hepatic fibrosis, and the development of HCC, therefore might act as a potential indicator for monitoring the HCC-related processes. Herein, with the contribution of a structurally optimized probe ETYZE-GGT, the bimodal imaging in both far red fluorescence (FL) and photoacoustic (PA) modes has been achieved in multiple HCC-related models. To our knowledge, this work covered the most comprehensive models including the fibrosis and developed HCC processes as well as the premonitory induction stages (autoimmune hepatitis, drug-induced liver injury, non-alcoholic fatty liver disease). ETYZE-GGT exhibited steady and practical monitoring performances on reporting the HCC stages via visualizing the GGT dynamics. The two modes exhibited working consistency and complementarity with high spatial resolution, precise apparatus and desirable biocompatibility. In cooperation with the existing techniques including testing serum indexes and conducting pathological staining, ETYZE-GGT basically realized the universal application for the accurate pre-clinical diagnosis of as many HCC stages as possible. By deeply exploring the mechanically correlation between GGT and the HCC process, especially during the premonitory induction stages, we may further raise the efficacy for the early diagnosis and treatment of HCC.
Asunto(s)
Carcinoma Hepatocelular , Técnicas Fotoacústicas , gamma-Glutamiltransferasa , gamma-Glutamiltransferasa/metabolismo , Animales , Humanos , Carcinoma Hepatocelular/diagnóstico por imagen , Técnicas Fotoacústicas/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Hepatopatías/diagnóstico por imagen , Imagen Óptica/métodos , Ratones , Masculino , Ratones Endogámicos BALB C , Hígado/patología , Hígado/diagnóstico por imagen , Hígado/enzimología , Colorantes Fluorescentes/químicaRESUMEN
In this work, a photoacoustic (PA) probe, HDS-GGT, was developed for the in vivo imaging of cardiovascular diseases by monitoring the γ-glutamyl transferase (GGT) dynamics. HDS-GGT exhibited a stable PA signal with auxiliary absorbance and NIRF variation after the trigger by GGT. In all three modalities of absorbance, NIRF, and PA, HDS-GGT could quantitatively reflect the GGT level. In PA modality, HDS-GGT indicated the practical advantages including high sensitivity, high stability, and high specificity. In living oxidized low-density lipoprotein-induced RAW264.7 cells, HDS-GGT indicated proper capability for imaging the plaques by visualizing the GGT dynamics. Moreover, during imaging in living model mice, HDS-GGT was achieved to distinguish the plaques from healthy blood vessels via a multiview PA presentation. HDS-GGT could also suggest the severity of plaques in the extracted aorta from the model mice, which was consistent with the histological staining results. The information herein might be useful for future investigations on cardiovascular diseases.
Asunto(s)
Enfermedades Cardiovasculares , Animales , Ratones , Enfermedades Cardiovasculares/diagnóstico por imagen , gamma-Glutamiltransferasa , Análisis Espectral , Diagnóstico por ImagenRESUMEN
Lipid metabolism diseases have become a tremendous risk worldwide, along with the development of productivity and particular attention to public health. It has been an urgent necessity to exploit reliable imaging strategies for lipids and thus to monitor fatty liver diseases. Herein, by converting the NIR-I signal to the NIR-II signal with IR1061 for the monitoring of lipid, the in vivo imaging of fatty liver disease was promoted on the contrast and visual effect. The main advantages of the imaging promotion in this work included a long emission wavelength, rapid response, and high signal-background-ratio (SBR) value. After promoting the NIR-I signal to NIR-II signal, IR1061 achieved higher SBR value and exhibited a dose-dependent fluorescence intensity at 1100 nm along with the increase of the EtOH proportion as well as steady and selective optical responses toward liposomes. IR1061 was further applied in the in vivo imaging of lipid in fatty liver diseases. In spite of the differences in body weight gain and TC level between healthy mice and fatty liver diseases two models, IR1061 achieved high-resolution imaging in the liver region to monitor the fatty liver disease status. This work might be informatic for the clinical diagnosis and therapeutical treatments of fatty liver diseases.
Asunto(s)
Boratos , Metabolismo de los Lípidos , Hepatopatías , Piranos , Animales , Ratones , Imagen Óptica/métodos , Colorantes Fluorescentes , LípidosRESUMEN
In this work, we reported a fluorescent probe Fur-SH, a derivative of benzofuranone, which was used to detect H2S in living cells and zebrafish. Based on the three structural characteristics of the probe, the effects of different structural modifications on the optical properties of the fluorophore were compared. Then, the fluorophore Fur-OH was synthesized by modifying diethylamino group with benzofuranone as the main skeleton. With 2,4-dinitrofluorobenzene as the recognition group and diethylamino as the electron donor, the push-pull electron effect occurred with nitro group, which led to fluorescence quenching, and an openable fluorescent probe Fur-SH was formed. The probe Fur-SH (λex = 510 nm; λem = 570 nm) had the advantages of smaller full width at half maxima, rapid response (5 min) and wide pH window. The quantitative properties of the probe were excellent, reaching saturation at 50 equivalents of substrate. The probe Fur-SH showed high sensitivity to H2S, with LOD of 48.9 nM and LOQ of 50 nM. At present, the probe Fur-SH had been applied to fluorescence imaging of MCF-7 cells and zebrafish. By comparing the effects of different structures on the optical properties of fluorophores, this work was expected to be helpful to the development of fluorescent probes in the future.
Asunto(s)
Colorantes Fluorescentes , Sulfuro de Hidrógeno , Humanos , Animales , Colorantes Fluorescentes/química , Pez Cebra , Sulfuro de Hidrógeno/análisis , Mitocondrias/química , Imagen Óptica , Células HeLaRESUMEN
In this work, a fluorescent probe, TPABF-HS, was developed for detecting hydrogen sulfide (H2S) using a human serum albumin (HSA)-binding-based approach for amplifying the fluorescence signal and extending the linear correlation range. Compared to the most recent probes for H2S, the most interesting feature of the detection system developed herein was the especially wide linear range (0-1000 µM (0-100 eq.)), which covered the physiological and pathological levels of H2S. TPABF-HS could be used in applications high sensitivity and selectivity with an LOD value of 0.42 µM. Further, site-competition experiments and molecular docking simulation experiments indicated that signal amplification was realized by the binding of the TPABF fluorophore to the naproxen-binding site of HSA. Moreover, the extension of the measurement span could allow for applications in living cells and Caenorhabditis elegans for imaging both exogenous and endogenous H2S. This work brings new information to the strategy of signal processing by exploiting fluorescent probes.
Asunto(s)
Colorantes Fluorescentes , Sulfuro de Hidrógeno , Humanos , Colorantes Fluorescentes/toxicidad , Colorantes Fluorescentes/química , Sulfuro de Hidrógeno/química , Simulación del Acoplamiento Molecular , Células HeLa , Microscopía FluorescenteRESUMEN
Herein, the Near-infrared imaging of hepatocellular carcinoma (HCC) and its medicinal treatment was achieved with a γ-glutamyl transpeptidase (GGT)-monitoring fluorescence probe KYZ-GGT which consisted of the typical recognition group γ-glutamyl and the structurally modified signal reporting group hemicyanine-thioxanthene. Compared with the recently reported probes, KYZ-GGT suggested practical and steady capability for monitoring the GGT level in the cellular, xenograft, induced as well as medicinal treatment HCC models. It realized the mitochondrial targeting intracellular imaging to reflect the GGT dynamics in the induction or medicinal treatment of HCC. In the xenograft and induced model mice with multiple factors, KYZ-GGT showed stable performance for visualizing the HCC status. In the medicinal treatment of the long-period-induced HCC model mice verified by the serum indexes and histopathological analysis, KYZ-GGT successfully imaged the medicinal treatment process of HCC with two marketed drugs (Sorafenib and Lenvatinib) respectively, with an applicative penetration depth. The information here was meaningful for investigating effective medicinal strategies for overcoming HCC.
Asunto(s)
Técnicas Biosensibles , Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Animales , Ratones , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/tratamiento farmacológico , gamma-Glutamiltransferasa/análisis , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/tratamiento farmacológico , Mitocondrias/químicaRESUMEN
Hepatocellular carcinoma (HCC) is one of the main principal causes of cancer death, and the late definite diagnosis limits therapeutic approaches in time. The early diagnosis of HCC is essential, and the previous investigations on the biomarkers inferred that the γ-glutamyltranspeptidase (GGT) level could indicate the HCC process. Herein, a near-infrared fluorescence/photoacoustic (NIRF/PA) bimodal probe, CySO3-GGT, was developed for monitoring the GGT level and thus to image the HCC process. After the in-solution tests, the bimodal response was convinced. The various HCC processes were imaged by CySO3-GGT at the cellular level. Then, the CCl4-induced HCC (both induction and treatment) and the subcutaneous and orthotopic xenograft mice models were selected. All throughout the tests, CySO3-GGT achieved NIRF and PA bimodal imaging of the HCC process. In particular, CySO3-GGT could effectively realize 3D imaging of the HCC nodule by visualizing the boundary between the tumor and the normal tissue. The information here might offer significant guidance for the dynamic monitoring of HCC in the near future.
Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Animales , Ratones , Carcinoma Hepatocelular/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Colorantes Fluorescentes , Imagen Óptica/métodos , XenoinjertosRESUMEN
Herein, a novel fluorescent probe HZY was developed for monitoring the sulfite (SO32-) dynamics. For the first time, the SO32- triggered implement was applied in the acute liver injury (ALI) model. The levulinate was selected to achieve the specific and relatively steady recognition reaction. With the addition of SO32-, the fluorescence response of HZY exhibited a large Stokes shift of 110 nm under the 380 nm excitation. The merits included high selectivity under various pH conditions. Compared with the reported fluorescent probes for sulfite, HZY indicated above-moderate performances including remarkable and rapid response (40 folds, within 15 min), and high sensitivity (limit of detection = 0.21 µM). Further, HZY could visualize the exogenous and endogenous SO32- level in living cells. Moreover, HZY could gauge the changing levels of SO32- in three types (induced by CCl4, APAP, and alcohol) of ALI models. Both in vivo imaging and depth-of-penetration fluorescence imaging demonstrated that HZY could characterize the developmental and therapeutic status during the liver injury process by measuring the dynamic of SO32-. The successful implementation of this project would promote the accurate in-situ detection of SO32- in liver injury, which was expected to guide the pre-clinical diagnosis and clinical practice.
Asunto(s)
Colorantes Fluorescentes , Quinoxalinas , Colorantes Fluorescentes/toxicidad , Colorantes Fluorescentes/química , Espectrometría de Fluorescencia , Imagen Óptica , Sulfitos/químicaRESUMEN
Herein, a novel fluorescent probe RhoDCM was developed for monitoring the cysteine (Cys) dynamics. For the first time, the Cys-triggered implement was applied in relatively complete diabetic mice models. The response of RhoDCM towards Cys suggested advantages including practical sensitivity, high selectivity, rapid reaction, and steadiness in various pH and temperature conditions. RhoDCM could basically monitor the intracellular Cys level, both exogenous and endogenous. It could further monitor the glucose level via detecting consumed Cys. Furthermore, the diabetic mice models including the no diabetic control group, the induced model groups by streptozocin (STZ) or alloxan, and the treatment groups induced by STZ and treated with vildagliptin (Vil), dapagliflozin (DA), or metformin (Metf) were constructed. The models were checked by oral glucose tolerance test and significant liver-related serum indexes. Based on the models, the in vivo imaging and penetrating depth fluorescence imaging both indicated that RhoDCM could characterize the status of the development and treatment in the diabetic process via monitoring the Cys dynamics. Consequently, RhoDCM seemed beneficial for inferring the order of severity in the diabetic process and evaluating the potency of therapeutic schedules, which might be informatic for correlated investigations.
Asunto(s)
Diabetes Mellitus Experimental , Metformina , Ratones , Animales , Humanos , Cisteína/química , Diabetes Mellitus Experimental/diagnóstico por imagen , Diabetes Mellitus Experimental/tratamiento farmacológico , Colorantes Fluorescentes/química , Metformina/farmacología , Metformina/uso terapéutico , Imagen Óptica , Células HeLaRESUMEN
In this work, a series of novel compounds Spartinin C1-C24 were screened, synthesised and evaluated for inhibiting xanthine oxidase thus lowering serum uric acid level. The backbones were derived from the components of coastal marine source Spartina alterniflora and marketed drugs. The top hits Spartinin C10 & C22 suggested high inhibition percentages (78.54 and 93.74) at 10 µM dosage, which were higher than the positive control Allopurinol. They were low cytotoxic onto human normal hepatocyte cells. Treatment with Spartinin C10 could lower the serum uric acid level to 440.0 µM in the hyperuricemic model mice (723.0 µM), comparable with Allopurinol (325.8 µM). Spartinin C10 was more appreciated than Allopurinol on other serum indexes. The preliminary pharmacokinetics evaluation indicated that the rapid absorption, metabolism and elimination of Spartinin C10 should be further improved. The discovery of pharmaceutical molecules from coastal marine source here might inspire the inter-disciplinary investigations on public health.
Asunto(s)
Alopurinol , Hiperuricemia , Humanos , Ratones , Animales , Alopurinol/farmacología , Alopurinol/uso terapéutico , Ácido Úrico/uso terapéutico , Ácidos Cumáricos , Hiperuricemia/tratamiento farmacológico , Xantina Oxidasa/metabolismoRESUMEN
Liver injury is a serious threat to human health, and γ-glutamyltranspeptidase (GGT) is proven to be one of the clinical biomarkers of liver injury. The conventional detection method of GGT activity in serum suffers from the complex operation, expensive equipment, and incapability of dynamically monitoring in biological samples. Herein, in consideration of the excellent characteristics of fluorescent probes, such as simple operation, high sensitivity, low cost, and good biocompatibility, a novel fluorescence detection method for GGT based on the combination of probe Rho-GGT and glutamic acid 5-hydrazide (glutamlhydrine) was designed. This method was applied to liver injury model mice to construct the relationship between the fluorescence signal, GGT activity, and the occurrence or development stage of liver injury. The fluorescence detection method combined with clinical indexes could more accurately characterize the situation of liver fibrosis, and evaluate the efficacy of liver fibrosis drugs, which could help provide important information for accurate diagnosis and early treatment of liver injury. The successful implementation of this project would promote the accurate in situ detection of GGT in liver injury, which was expected to guide pre-clinical diagnosis and clinical practice.
RESUMEN
Sulfite (SO32-) is considered as a monitor of a wide range of physiological processes. However, cells and tissues are adversely affected when the body ingests high level of sulfite. Here, we designed and synthesized a "turn on" fluorescent probe ImiSft-1 with 2-cyano-N-methylacetamide as the specific recognition site of SO32-. This probe predominantly achieved high response intensity to SO32- and desirable properties such as large Stokes shift (â¼180 nm), fast response time (within 15 s), and high sensitivity (LOD = 0.12 µM). Importantly, the probe was highly selective for sulfite from other bio-species including biological thiols. Other functional properties included broad pH adaptability (5.0-10.0) and low cytotoxicity. Given these advantages and the fluorescence imaging in living MCF-7 cells, it was demonstrated that probe ImiSft-1 could monitor the changes of sulfite concentration in living cells.
Asunto(s)
Colorantes Fluorescentes , Sulfitos , Colorantes Fluorescentes/química , Humanos , Células MCF-7 , Imagen Óptica , Compuestos de SulfhidriloRESUMEN
In this work, hit compounds Spartinin F1-F20 sharing the Spartina alterniflora-sourced ferulic acid backbone were synthesized and evaluated on inhibiting xanthine oxidase and lowering uric acid level. The top hit Spartinin F2 exhibited inhibition percentages at 10 µM dosage as high as 84.48 (higher than that of the positive control allopurinol) and low cyto-toxicity. Spartinin F2 inferred potential efficiency in lowering the serum UA level (from 631.6 µM to 295.0 µM), which was comparable with allopurinol (to 309.2 µM). Spartinin F2 was also beneficial for other serum indexes. The bioavailability of Spartinin F2 was 63.71% from the preliminary pharmacokinetics test and the molecular docking simulation indicated that except for retaining the hydrogen bonds with the key residues such as THR 1010 and LYS 771, the introduction of the π-sulfur interactions via the sulfonate might also be beneficial for developing more potent XO inhibitors.
Asunto(s)
Alopurinol , Xantina Oxidasa , Alopurinol/química , Alopurinol/farmacología , Inhibidores Enzimáticos/química , Inhibidores Enzimáticos/farmacología , Simulación del Acoplamiento Molecular , Relación Estructura-Actividad , Ácido Úrico , Xantina Oxidasa/metabolismoRESUMEN
Based on OR logic gate, we proposed a smart near-infrared (NIR) fluorescent probe, named VPCPP, for simultaneously monitoring local microviscosity, micropolarity, and carboxylesterases (CEs) in living cells through blue and red channels. This proposed probe was capable of distinguishing cancer cells from normal cells and had good potential for identifying living liver cell lines. Furthermore, the fluctuations of the three analytes of interest in different cell status was successfully explored. Particularly, facilitated with high-content analysis (HCA) and VPCPP, a simple and efficient high-throughput screening (HTS) platform was first constructed for screening antitumor drugs and studying their effect on the analytes. For the first time, we found that sorafenib-induced ferroptosis led to an increase in the microviscosity and up-regulation of CEs at the same time. Additionally, the procedure that aristolochic acid (AA) induced the overexpression of CEs was verified. Besides, VPCPP was utilized for imaging the variations of the two microenvironment parameters and CEs in the inflammation model. Finally, VPCPP was able to image the tumor ex vivo and in vivo through two channels and one channel separately, as well as to visualize the kidneys and liver ex vivo with dual emissions, which indicated that the probe had great potential for imaging applications such as medical diagnosis, preclinical research, and imaging-guided surgery.
Asunto(s)
Colorantes Fluorescentes , Cirugía Asistida por Computador , Hidrolasas de Éster Carboxílico , Línea Celular , Colorantes Fluorescentes/metabolismo , Imagen Óptica/métodos , ViscosidadRESUMEN
H2S has been reported to play essential roles in a variety of physiological and pathological procedures. In this work, a novel fluorescent probe, Rho-HS, for detecting H2S was developed by introducing the ortho-halogen to activate the least reactive recognition group 2,4-dinitrophenyl moiety. In combination of the structures from both Rhodamine B and fluorescein, Rho-HS could generate both the colorimetric and fluorescent responses. This feature was not frequently achieved and could lead to the quantitative and convenient for the end-user. In comparison with recent probes for H2S, the major advantages of Rho-HS included suiting wide pH range (6.0-10.0), relatively rapid response (within 15 min) and the high selectivity among the competing species including the biothiols. With low cytoxicity, Rho-HS was further applied in the biological imaging in living MCF-7 cells and Caenorhabditis elegans. We hope that the designing strategy in this work might provide useful information for more preferable implements in this field.
Asunto(s)
Sulfuro de Hidrógeno , Xantonas , Fluoresceína , Colorantes Fluorescentes , Imagen ÓpticaRESUMEN
Mercury is a highly toxic and non-essential element that is found in every corner of the globe. The small amount of mercury produced by various pathways eventually enters freshwater and marine ecosystems, circulating through the food chain (especially fish) and causing various environmental problems in aspects including plants, animals, and human. There are several traditional quantitative methods developed for mercury ions (II) analysis in water samples. However, due to the complexity of the detection process, high cost and strong technical expertise, it is difficult to detect mercury ions in real-time. Therefore, in recent years, a large number of researchers have developed small-molecule fluorescent probes for Hg ions detection. Fluorimetry has the advantages of convenient detection, short response time, high sensitivity and good selectivity. This review summarized the small-molecule fluorescent probes for mercuric ion detection developed in recent years according to the chemical structural classification, compared their performances and elaborated the mechanism. We hope that the review will help the researches for the designs of metal ions fluorescent probes and their applications with certain reference value.
Asunto(s)
Mercurio , Animales , Ecosistema , Colorantes Fluorescentes/química , Humanos , Iones/análisis , Mercurio/análisis , Mercurio/químicaRESUMEN
Human serum albumin (HSA) is a biological macromolecule with important physiological functions; abnormal HSA levels are associated with coronary heart disease, multiple myeloma, diabetes, nephropathy, neurometabolic disorders, liver cirrhosis and other diseases. Therefore, accurate and quantitative detection of HAS have extremely important research and application value in biological science, molecular biology, clinical medicine and other fields. As for the detection method of HSA, dye-binding method and immune method are the first to be used, and have been applied in clinical detection. In recent years, many new detection technologies have emerged, such as fluorescent probe detection method, nano-materials for HSA detection, biosensor and so on. Although there are many methods developed recently to detect HSA, comprehensive reviews for HSA detection methods are still rare. Thus, writing this review to fill in the blank is in need. In order to highlight the recent progress in the field of HSA detection, in this review, the methods used to detect HSA are summarized and sorted, the advantages and disadvantages of these detection methods are also listed, then the research progress of small molecular fluorescence probe method is emphatically introduced in this paper. Then, we briefly discussed the challenges and future development directions in this field.