Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Huan Jing Ke Xue ; 45(6): 3297-3307, 2024 Jun 08.
Artículo en Chino | MEDLINE | ID: mdl-38897752

RESUMEN

Land use changes lead to changes in the functions of different types of carbon sources and sinks, which are key sources of carbon emissions. The study of carbon emissions and its influencing factors in the Aksu River Basin from the perspective of land use change is of great importance for the promotion of integrated protection and restoration of mountains, water, forests, fields, lakes, grasslands, sand, and ice in the basin and to help achieve the goal of carbon peaking and carbon neutrality. Based on four periods of land use data and socio-economic data from 1990 to 2020, the total carbon emissions from land use were measured, and the spatial and temporal trajectories of carbon emissions and their influencing factors were explored. The results showed that:① from 1990 to 2020, arable land, forest land, construction land, and unused land showed a general increasing trend, whereas grasslands and water areas showed a decreasing trend. The spatial change in land use types was mainly characterized by the conversion of grasslands and unused land into arable land, and 83.58 % of the arable land conversion areas were concentrated in the southwest of Wensu, Aksu, and the northern part of Awat. ② The total net carbon emissions in the basin showed a continuous growth trend from 1990 to 2020, with a cumulative increase of 14.78×104 t. The increase in arable land was a key factor causing an increase in net carbon emissions in the basin. ③ The spatial distribution pattern of land use carbon emissions in the basin was high in the middle and low in the fourth, with significant changes in net carbon emissions mainly in the southern part of Wensu, Aksu, Awat, and Alaer. ④ Human activities had the strongest driving effect on land use carbon emissions, with their effects gradually increasing from east to west. The contribution of average annual temperature to land use carbon emissions was mainly concentrated in the eastern part of Aksu and the northern part of Awat, whereas average annual rainfall had a strong inhibitory effect on the northern part of Wensu and the western part of Aheqi.

2.
EJNMMI Phys ; 9(1): 23, 2022 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-35348926

RESUMEN

BACKGROUND: To investigate the influence of small voxel Bayesian penalized likelihood (SVB) reconstruction on small lesion detection compared to ordered subset expectation maximization (OSEM) reconstruction using a clinical trials network (CTN) chest phantom and the patients with 18F-FDG-avid small lung tumors, and determine the optimal penalty factor for the lesion depiction and quantification. METHODS: The CTN phantom was filled with 18F solution with a sphere-to-background ratio of 3.81:1. Twenty-four patients with 18F-FDG-avid lung lesions (diameter < 2 cm) were enrolled. Six groups of PET images were reconstructed: routine voxel OSEM (RVOSEM), small voxel OSEM (SVOSEM), and SVB reconstructions with four penalty factors: 0.6, 0.8, 0.9, and 1.0 (SVB0.6, SVB0.8, SVB0.9, and SVB1.0). The routine and small voxel sizes are 4 × 4 × 4 and 2 × 2 × 2 mm3. The recovery coefficient (RC) was calculated by dividing the measured activity by the injected activity of the hot spheres in the phantom study. The SUVmax, target-to-liver ratio (TLR), contrast-to-noise ratio (CNR), the volume of the lesions, and the image noise of the liver were measured and calculated in the patient study. Visual image quality of the patient image was scored by two radiologists using a 5-point scale. RESULTS: In the phantom study, SVB0.6, SVB0.8, and SVB0.9 achieved higher RCs than SVOSEM. The RC was higher in SVOSEM than RVOSEM and SVB1.0. In the patient study, the SUVmax, TLR, and visual image quality scores of SVB0.6 to SVB0.9 were higher than those of RVOSEM, while the image noise of SVB0.8 to SVB1.0 was equivalent to or lower than that of RVOSEM. All SVB groups had higher CNRs than RVOSEM, but there was no difference between RVOSEM and SVOSEM. The lesion volumes derived from SVB0.6 to SVB0.9 were accurate, but over-estimated by RVOSEM, SVOSEM, and SVB1.0, using the CT measurement as the standard reference. CONCLUSIONS: The SVB reconstruction improved lesion contrast, TLR, CNR, and volumetric quantification accuracy for small lesions compared to RVOSEM reconstruction without image noise degradation or the need of longer emission time. A penalty factor of 0.8-0.9 was optimal for SVB reconstruction for the small tumor detection with 18F-FDG PET/CT.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...