Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Electrophoresis ; 41(23): 2007-2014, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32776330

RESUMEN

A three-dimensional-printed microfluidic device made of a thermoplastic material was used to study the creation of molecular filters by controlled dielectric breakdown. The device was made from acrylonitrile butadiene styrene by a fused deposition modeling three-dimensional printer and consisted of two V-shaped sample compartments separated by 750 µm of extruded plastic gap. Nanofractures were formed in the thin piece of acrylonitrile butadiene styrene by controlled dielectric breakdown by application voltage of 15-20 kV with the voltage terminated when reaching a defined current threshold. Variation of the size of the nanofractures was achieved by both variation of the current threshold and by variation of the ionic strength of the electrolyte used for breakdown. Electrophoretic transport of two proteins, R-phycoerythrin (RPE; <10 nm in size) and fluorescamine-labeled BSA (f-BSA; 2-4 nm), was used to monitor the size and transport properties of the nanofractures. Using 1 mM phosphate buffer, both RPE and f-BSA passed through the nanofractures when the current threshold was set to 25 µA. However, when the threshold was lowered to 10 µA or lower, RPE was restricted from moving through the nanofractures. When we increased the electrolyte concentration during breakdown from 1 to 10 mM phosphate buffer, BSA passed but RPE was blocked when the threshold was equal to, or lower than, 25 µA. This demonstrates that nanofracture size (pore area) is directly related to the breakdown current threshold but inversely related to the concentration of the electrolyte used for the breakdown process.


Asunto(s)
Electrólitos/química , Electroforesis/instrumentación , Técnicas Analíticas Microfluídicas , Nanoestructuras/química , Impresión Tridimensional/instrumentación , Butadienos/química , Diseño de Equipo , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Proteínas/análisis , Proteínas/química , Estireno/química
2.
Biosensors (Basel) ; 9(1)2019 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-30704056

RESUMEN

On-site therapeutic drug monitoring (TDM) is important for providing a quick and accurate dosing to patients in order to improve efficacy and minimize toxicity. Aminoglycosides such as amikacin, gentamicin, and tobramycin are important antibiotics that have been commonly used to treat infections of chronic bacterial infections in the urinary tract, lung, and heart. However, these aminoglycosides can lead to vestibular and auditory dysfunction. Therefore, TDM of aminoglycosides is important due to their ototoxicity and nephrotoxicity. Here, we have developed a hot embossed poly (methyl methacrylate) (PMMA) microfluidic device featuring an electrokinetic size and mobility trap (SMT) to purify, concentrate, and separate the aminoglycoside antibiotic drugs amikacin, gentamicin, and tobramycin. These drugs were separated successfully from whole blood within 3 min, with 30-fold lower detection limits compared to a standard pinched injection. The limit of detections (LOD) were 3.75 µg/mL for gentamicin, 8.53 µg/mL for amikacin, and 6.00 µg/mL for tobramycin. These are sufficient to cover the therapeutic range for treating sepsis of 6⁻10 µg/mL gentamicin and tobramycin and 12⁻20 µg/mL of amikacin. The device is simple and could be mass produced via embossing or injection molding approaches.


Asunto(s)
Aminoglicósidos/sangre , Monitoreo de Drogas/instrumentación , Dispositivos Laboratorio en un Chip , Polimetil Metacrilato/química , Nanopartículas/química
3.
PLoS One ; 12(5): e0176997, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28472086

RESUMEN

Diffuse axonal injury is a hallmark pathological consequence of non-penetrative traumatic brain injury (TBI) and yet the axonal responses to stretch injury are not fully understood at the cellular level. Here, we investigated the effects of mild (5%), very mild (0.5%) and repetitive very mild (2×0.5%) axonal stretch injury on primary cortical neurons using a recently developed compartmentalized in vitro model. We found that very mild and mild levels of stretch injury resulted in the formation of smaller growth cones at the tips of axons and a significantly higher number of collapsed structures compared to those present in uninjured cultures, when measured at both 24 h and 72 h post injury. Immunocytochemistry studies revealed that at 72 h following mild injury the axonal growth cones had a significantly higher colocalization of ßIII tubulin and F-actin and higher percentage of collapsed morphology than those present following a very mild injury. Interestingly, cultures that received a second very mild stretch injury, 24 h after the first insult, had a further increased proportion of growth cone collapse and increased ßIII tubulin and F-actin colocalization, compared with a single very mild injury at 72 h PI. In addition, our results demonstrated that microtubule stabilization of axons using brain penetrant Epothilone D (EpoD) (100 nM) resulted in a significant reduction in the number of fragmented axons following mild injury. Collectively, these results suggest that mild and very mild stretch injury to a very localized region of the cortical axon is able to trigger a degenerative response characterized by growth cone collapse and significant abnormal cytoskeletal rearrangement. Furthermore, repetitive very mild stretch injury significantly exacerbated this response. Results suggest that axonal degeneration following stretch injury involves destabilization of the microtubule cytoskeleton and hence treatment with EpoD reduced fragmentation. Together, these results contribute a better understanding of the pathogenesis of mild and repetitive TBI and highlight the therapeutic effect of microtubule targeted drugs on distal part of neurons using a compartmentalized culturing model.


Asunto(s)
Axones , Citoesqueleto/metabolismo , Lesión Axonal Difusa/patología , Conos de Crecimiento/patología , Células Cultivadas , Humanos , Técnicas In Vitro , Microfluídica/instrumentación
4.
Biomicrofluidics ; 8(4): 044110, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25379095

RESUMEN

A new model for studying localised axonal stretch injury is presented, using a microfluidic device to selectively culture axons on a thin, flexible poly (dimethylsiloxane) membrane which can be deflected upward to stretch the axons. A very mild (0.5% strain) or mild stretch injury (5% strain) was applied to primary cortical neurons after 7 days growth in vitro. The extent of distal degeneration was quantified using the degenerative index (DI, the ratio of fragmented axon area to total axon area) of axons fixed at 24 h and 72 h post injury (PI), and immunolabelled for the axon specific, microtubule associated protein-tau. At 24 h PI following very mild injuries (0.5%), the majority of the axons remained intact and healthy with no significant difference in DI when compared to the control, but at 72 h PI, the DI increased significantly (DI = 0.11 ± 0.03). Remarkably, dendritic beading in the somal compartment was observed at 24 h PI, indicative of dying back degeneration. When the injury level was increased (5% stretch, mild injury), microtubule fragmentation along the injured axons was observed, with a significant increase in DI at 24 h PI (DI = 0.17 ± 0.02) and 72 h PI (DI = 0.18 ± 0.01), relative to uninjured axons. The responses observed for both mild and very mild injuries are similar to those observed in the in vivo models of traumatic brain injury, suggesting that this model can be used to study neuronal trauma and will provide new insights into the cellular and molecular alterations characterizing the neuronal response to discrete axonal injury.

5.
Anal Chem ; 85(21): 10051-6, 2013 Nov 05.
Artículo en Inglés | MEDLINE | ID: mdl-24063252

RESUMEN

With the introduction of hobby laser engravers/cutters, the use of CO2 laser micromachining on poly(methyl methacrylate) (PMMA) has the potential for flexible, low cost, rapid prototyping of microfluidic devices. Unfortunately, the feature size created by most entry-level CO2 laser micromachining systems is too large to become a functional tool in analytical microfluidics. In this paper, we report a novel method to reduce the feature size of microchannels and the bulges formed at the rim of the channel during CO2 laser micromachining by passing the laser beam through a stainless steel pinhole. Without the pinhole, the channel width was typically 300 µm wide. However, when 50 or 35 µm diameter pinholes were used, channel widths of 60 and 25 µm, respectively, could be obtained. The height of the bulge deposited directly next to the channel was reduced to less than 0.8 µm with the pinhole during ablation. Separations of fluorescent dyes on devices ablated with and without the pinhole were compared. On devices fabricated with the pinhole, the number of theoretical plates/m was 2.2-fold higher compared to devices fabricated without the pinhole, and efficiencies comparable to embossed PMMA and laser ablated glass chips were obtained. A mass-produced commercial hobby laser (retailing at ∼$2500), when equipped with a $500 pinhole, represents a rapid and low-cost approach to the rapid fabrication of rigid plastic microchips including the narrow microchannels required for microchip electrophoresis.


Asunto(s)
Electroforesis por Microchip/instrumentación , Láseres de Gas , Acero Inoxidable , Electroforesis por Microchip/métodos , Microscopía Electrónica de Rastreo , Polimetil Metacrilato/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...