Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Asian J Endosc Surg ; 17(1): e13252, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37839891

RESUMEN

Laparoscopic cystectomy for mature teratomas is associated with a high incidence of intraperitoneal spillage and tumor spread; however, extragonadal recurrence of this benign tumor is rare. We hereby present an additional case of extragonadal mature teratoma that recurred in the pouch of Douglas after ovarian cystectomy. A 43-year-old Japanese woman presented with atypical genital bleeding. A 7 cm mature teratoma was detected using transvaginal ultrasonography and magnetic resonance imaging. At 26 years old, she underwent bilateral cystectomy for bilateral mature teratoma of the ovary. During laparoscopic surgery, a cystic tumor appeared in the pouch of Douglas and was firmly adhered to the surrounding tissues. Both ovaries were normal. The resected tumor was diagnosed as extragonadal, benign, mature teratoma. To avoid the extragonadal recurrence of mature teratoma, removal of tumor contents from intraperitoneal spillage by lavage should be performed at the end of surgery.


Asunto(s)
Pared Abdominal , Laparoscopía , Neoplasias Ováricas , Teratoma , Femenino , Humanos , Adulto , Neoplasias Ováricas/diagnóstico , Neoplasias Ováricas/patología , Neoplasias Ováricas/cirugía , Teratoma/cirugía , Teratoma/diagnóstico , Teratoma/patología , Pared Abdominal/patología
2.
Eur J Obstet Gynecol Reprod Biol ; 271: 132-137, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35189440

RESUMEN

OBJECTIVE: Transabdominal amnioinfusion is beneficial in oligohydramnios, which has high fetal mortality and does not improve with observation alone. However, there are few reports on the maternal adverse events of transabdominal amnioinfusion. This study aimed to evaluate the adverse events of amniocentesis with transabdominal amnioinfusion. STUDY DESIGN: This study is a retrospective cohort study at a single tertiary perinatal center in Japan. A total of 313 procedures in 126 patients who underwent amniocentesis for transabdominal amnioinfusion at our tertiary perinatal institution were evaluated using the Common Terminology Criteria for Adverse Events (CTCAE). Adverse events were retrospectively examined using a 5-grade evaluation based on the CTCAE. Procedurally, a 21-23-G percutaneous transhepatic cholangiography drainage (PTCD) needle was advanced under ultrasound guidance into the amniotic fluid cavity with a gravity-fed infusion of warm saline solution. RESULTS: No maternal deaths were recorded. Only two maternal/fetal adverse events occurred, and grade 4 fetal adverse events requiring pregnancy termination were observed in seven cases. Fetal death occurred in five cases, all with severe oligohydramnios and premature rupture of the membranes. No placental abruption or bleeding occurred before or after delivery. CONCLUSION: Adverse events during transabdominal amnioinfusion were successfully analyzed using CTCAE. We also provided new terminology for evaluating adverse events during amnioinfusion. Our results may encourage obstetricians to perform amnioinfusion in difficult situations, with less concern for severe maternal or fetal adverse events.


Asunto(s)
Rotura Prematura de Membranas Fetales , Oligohidramnios , Líquido Amniótico , Femenino , Edad Gestacional , Humanos , Oligohidramnios/etiología , Embarazo , Estudios Retrospectivos
3.
J Matern Fetal Neonatal Med ; 35(1): 86-90, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32106728

RESUMEN

OBJECTIVES: Although amnioinfusion (AI) for repetitive variable deceleration has been reported to reduce the frequency of variable deceleration and cesarean section (CS) rate, CS is sometimes unavoidable even after therapeutic AI. The purpose of this study was to investigate prenatal factors related to the efficacy of therapeutic AI during labor. METHODS: This retrospective study investigated 80 singleton pregnancies that underwent transcervical therapeutic AI for repetitive variable deceleration during labor. AI was performed with 500 mL of warmed saline through an intrauterine pressure catheter by gravity infusion. Prenatal factors related to emergency CS for fetal distress even after therapeutic AI were investigated. RESULTS: Emergency CS was performed for 12 of the 80 cases due to fetal distress. Z-score for umbilical cord length was significantly smaller in the CS group (-0.68 SD) than in the vaginal delivery group (0.15 SD, p < .001). No CSs were performed in cases with Z-score for umbilical cord length >-0.05 SD. No significant differences between CS and vaginal delivery groups were seen in gestational age at delivery, cervical dilatation at AI, birth weight, Z-score of birth weight, incidence of the nuchal cord or incidence of abnormal umbilical cord insertion. CONCLUSIONS: Therapeutic AI for repetitive variable deceleration was considered useful, in many cases avoiding emergency CS. Short umbilical cord length (lower Z-score) was related to emergency CS after therapeutic AI for repetitive variable deceleration. Umbilical cord length may offer an important factor for assessing the risk of fetal distress that is difficult to avoid, if methods to accurately determine umbilical cord length can be developed.


Asunto(s)
Cesárea , Desaceleración , Parto Obstétrico , Femenino , Humanos , Embarazo , Estudios Retrospectivos , Cordón Umbilical
4.
J Matern Fetal Neonatal Med ; 33(17): 2933-2940, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30585101

RESUMEN

Aim: Our study aimed to clarify the prognosis of bilateral and unilateral umbilical artery end-diastolic blood flow abnormalities (BFAs) in monochorionic diamniotic twin pregnancies.Methods: Monochorionic diamniotic twin pregnancies were classified into bilateral (group 1), unilateral (group 2), and no (group 3) umbilical artery end-diastolic BFAs. After the usual obstetric management, short- and long-term prognoses were analyzed.Results: A total of 171 monochorionic diamniotic twins were analyzed and classified into group 1 (13 twins, 7.6%), 2 (12 twins, 7.0%), and 3 (146 twins, 85.4%). Gestational age at delivery was significantly lower in group 1 than in groups 2 and 3 (median, 29.3, 35.6, and 35.6 weeks, respectively; p < .01 and p < .001). The survival rate of fetuses with BFAs was significantly lower in group 1 than in group 2 (23.0% [3/13] versus 100% [12/12]; p < .001). However, the survival rate of the co-twin was not significantly different between groups 1 and 2 (84.6% [11/13] versus 100% [12/12]; p = .48). The survival rate of both fetuses was significantly lower in group 1 than in groups 2 and 3 (53.8% [14/26], 100% [24/24], and 98.6% [288/292], respectively; both p < .001). In cases with fetal therapy, the survival rate of both fetuses tended to be lower in group 1 than in group 2 (44.4% [8/18] versus 83.3% [10/12]; p = .05). In cases without fetal therapy, the gestational age at delivery tended to lower in group 1 than in group 2 and was significantly lower than in group 3 (median, 29.1, 35.6, 35.6 weeks, respectively; p = .05 and p < .05). The survival rate of fetuses with BFA tended to be lower in group 1 than in group 2 (50.0% [2/4] versus 100% [12/12]; p = .05). The survival rate of the co-twin was not significantly different between groups 1 and 2 (100% [4/4] versus 100% [12/12]; p = 1). The survival rate of both fetuses tended to be lower in group 1 than in group 2 and was significantly lower than in group 3 (75% [6/8], 100% [24/24], and 99.2% [278/280], respectively; p = .05 and p < .01).Conclusions: In monochorionic diamniotic twin pregnancies, bilateral umbilical artery end-diastolic BFAs demonstrated a poor prognosis. However, unilateral abnormalities exhibited a good prognosis similar to that in twins with normal umbilical artery blood flow. If such abnormalities are detected during a routine checkup, the umbilical artery pulse wave on the other side should be examined.


Asunto(s)
Enfermedades Fetales , Arterias Umbilicales , Enfermedades en Gemelos , Femenino , Retardo del Crecimiento Fetal , Edad Gestacional , Humanos , Embarazo , Embarazo Gemelar , Gemelos Monocigóticos , Arterias Umbilicales/diagnóstico por imagen
5.
Fetal Diagn Ther ; 47(1): 60-65, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31212278

RESUMEN

BACKGROUND: There have been no previous reports on the postnatal course, especially long-term outcomes, of fetal hydrothorax patients, including those treated with thoracoamniotic shunting (TAS) using a double-basket catheter.The outcomes of cases from a single center are reported. METHODS: Cases of fetal hydrothorax managed at our center between 2005 and 2015 were enrolled retrospectively. TAS was performed if indicated. Long-term outcomes such as cerebral palsy, developmental disabilities, and others were analyzed. RESULTS: Ninety-two cases of fetal hydrothorax were included. The causes were primary chylothorax, transient abnormal myelopoiesis, cardiac disease, pulmonary sequestration, mediastinal neoplasm, and infection. TAS was performed in 36 cases. Early neonatal death occurred in 19 cases. The 28-day survival rates for all cases and for TAS cases were 70% (48/69) and 72% (26/36), respectively. Of the cases that underwent TAS, one was treated with home oxygen therapy, one was diagnosed with cerebral palsy and severe intellectual disability, and five were diagnosed with mild or moderate developmental disabilities. CONCLUSIONS: The results showed that the survival rate and long-term outcomes of cases with hydrothorax have improved as TAS has become more prevalent. The reasons for these results need to be elucidated, and efforts are needed to further improve outcomes.


Asunto(s)
Terapias Fetales , Hidrotórax/mortalidad , Femenino , Humanos , Hidrotórax/terapia , Embarazo , Estudios Retrospectivos
6.
Eur J Obstet Gynecol Reprod Biol ; 241: 82-87, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31476656

RESUMEN

OBJECTIVES: Some monochorionic twin pregnancies need intensive cardiac management even in the absence of twin-to-twin transfusion syndrome after birth. The purpose of this study was to investigate risk factors related to persistent hypotension requiring cardiotonic agent use among monochorionic twin pregnancies without twin-to-twin transfusion syndrome. STUDY DESIGN: This was a retrospective study of 316 monochorionic twin pregnancies without twin-to-twin transfusion syndrome (632 babies). All cases were treated in the neonatal intensive care unit. Hypotension was defined as mean arterial blood pressure below the norm for gestational age. Decreased left ventricular ejection fraction was defined as a value <60%. Dopamine, dobutamine and phosphodiesterase III inhibitor were used as cardiotonic agents for hypotension persisting even after adequate infusion. RESULTS: Among the 632 cases, 33 (5.2%) needed cardiotonic agents for persistent hypotension. The frequency of persistent hypotension with decreased left ventricular ejection fraction was significantly higher among larger twins (4.4%) than among smaller twins (0.6%, p = 0.0038). In larger twins, multivariate analysis showed that Z-score for cardiothoracic area ratio (odds ratio, 2.31; p < 0.001), tricuspid regurgitation (odds ratio, 6.34; p = 0.015) and gestational age at delivery (odds ratio, 0.66; p < 0.001) correlated with persistent hypotension. In smaller twins, univariate analysis showed gestational age at delivery, birth weight, Z-score for birth weight and Z-score for cardiothoracic area ratio of the larger twin were related to persistent hypotension. Concentration of brain natriuretic peptide in the umbilical vein in larger and smaller twins were significantly correlated (coefficient of correlation = 0.792, p < 0.001). CONCLUSIONS: In monochorionic twin pregnancies, attention needs to be given to cardiac size along with amniotic fluid and fetal growth. Both larger and smaller twins carry risks of persistent hypotension after birth. Close observation is needed, especially in cases where the larger twin displays cardiomegaly despite absence of twin-to-twin transfusion syndrome.


Asunto(s)
Cardiomegalia , Enfermedades Fetales , Hipotensión/terapia , Cuidado Intensivo Neonatal , Embarazo Gemelar , Femenino , Humanos , Recién Nacido , Embarazo , Estudios Retrospectivos , Gemelos Monocigóticos
8.
Eur J Obstet Gynecol Reprod Biol ; 235: 62-65, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30797177

RESUMEN

OBJECTIVES: Our study aimed to analyze the differences in intra-amniotic pressures in patients with polyhydramnios with and without symptoms. STUDY DESIGN: We recruited patients with pregnancies in which amnioreduction was performed for polyhydramnios in the Department of Fetal-Maternal Medicine at Nagara Medical Center between April 2017 and August 2018. Amnioreduction was performed for severe polyhydramnios with maternal symptoms [symptomatic group] or polyhydramnios without maternal symptoms [asymptomatic group] such as abdominal distension, dyspnea, or threatened premature labor. We measured the intra-amniotic pressure after every 200 ml volume reduction during the amnioreduction. RESULTS: A total of 27 patients who underwent amnioreduction were classified into symptomatic (66.7%, 18/27) and asymptomatic (33.3%, 9/27) groups. Gestational age, amniotic fluid index at the time of amnioreduction, and the volume of amniotic fluid removed were not significantly different between the symptomatic and asymptomatic groups [median 32.4 weeks vs. 33.1 weeks, median 38.0 cm vs. 39.0 cm, and median 1500 ml vs. 2500 ml, respectively]. However; the intra-amniotic pressure before amnioreduction was significantly higher in the symptomatic group than in the asymptomatic group [median 15.0 mmHg (range, 10-27) vs. 10.0 mmHg (range, 6.0-13); p < 0.005]. After amnioreduction, these pressures decreased significantly to median 9.0 mmHg (range, 5.0-13) (p < 0.001) in the symptomatic and 7.0 mmHg (range, 4.0-11) (p < 0.05) in the asymptomatic group. The median intra-amniotic pressure gradually decreased and reached a plateau during the amnioreductions in both groups. CONCLUSIONS: With polyhydramnios, the intra-amniotic pressure was significantly higher in the symptomatic group than in the asymptomatic group. Therefore, uterine pressure tolerance might vary according to the individual. In addition, intra-amniotic pressure monitoring might enhance the safety during amnioreduction procedures to avoid drastic and potentially harmful pressure changes.


Asunto(s)
Líquido Amniótico/fisiología , Polihidramnios/patología , Abdomen/patología , Adulto , Enfermedades Asintomáticas , Disnea/etiología , Disnea/patología , Femenino , Edad Gestacional , Humanos , Polihidramnios/terapia , Embarazo , Presión , Adulto Joven
9.
J Obstet Gynaecol ; 39(1): 49-53, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30246578

RESUMEN

We report prophylactic amnioinfusion (AI) for variable decelerations in umbilical cord compression without oligohydramnios as an early sign of deterioration. We performed a transabdominal AI in cases without oligohydramnios using the ultrasonography findings of umbilical cord compression (i.e. sandwich sign [SWS]) and variable decelerations (VD) in a foetal heart rate. Thirteen cases and 21 AIs were analysed. Nine (69%) cases were of a foetal growth restriction and 4 (31%) had umbilical hyper-coiled cords. VD frequency (p < .0001), umbilical artery pulsatility index (PI) (p < .01) and ductus venous PI (0.66 vs. 0.48; p < .05) significantly decreased, and an umbilical venous (UV) flow volume (121 vs. 197 ml/min/kg; p < .05) significantly increased after AI. The umbilical artery diastolic blood flow abnormalities and UV pulsation improved. In conclusion, AI improves the umbilical cord compression even without oligohydramnios. The SWS is an important marker of deterioration to severe oligohydramnios and latent foetal damage. IMPACT STATEMENT What is already known on this subject? Antepartum variable decelerations due to umbilical cord compression are significantly associated with the deceleration in labour. In particular, foetal hypoxia leads to other adverse events such as foetal distress, hypoxic-ischemic encephalopathy, and pulmonary arterial hypertension after birth. Amnioinfusion has been shown to be effective in patients who also have oligohydramnios. What do the results of this study add? Amnioinfusion may be effective in the cases with ultrasonography findings of umbilical cord compression (i.e. sandwich sign) and in cases with variable decelerations in foetal heart rate, but without oligohydramnios. What are the implications of these findings for clinical practice and/or further research? Amnioinfusion may be helpful to prevent adverse events including oligohydramnios and anhydroamnios.


Asunto(s)
Constricción Patológica/terapia , Sufrimiento Fetal/terapia , Cordón Umbilical/irrigación sanguínea , Adulto , Biomarcadores , Constricción Patológica/diagnóstico por imagen , Parto Obstétrico/estadística & datos numéricos , Femenino , Edad Gestacional , Frecuencia Cardíaca Fetal , Humanos , Recién Nacido , Inyecciones , Oligohidramnios/prevención & control , Embarazo , Flujo Pulsátil , Ultrasonografía Prenatal , Cordón Umbilical/diagnóstico por imagen
10.
Case Rep Obstet Gynecol ; 2018: 4281528, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30298111

RESUMEN

Intra-amniotic, fetal intrathoracic, and intraperitoneal pressures during pregnancy have been previously investigated. However, to our knowledge, changes in these pressures during uterine contractions have not been reported. Herein, we present three cases of polyhydramnios, fetal pleural effusion, and fetal ascites, in which intra-amniotic, fetal intrathoracic, intraperitoneal pressures increased with uterine contractions. These pressure increases may affect the fetal circulation. We suggest that managing potential premature delivery (e.g., with tocolysis) is important in cases with polyhydramnios and excess fluid in fetal body areas, such as the thorax, abdomen, and heart. The results of this preliminary study on intrafetal pressure measurements will be useful in performing fetal and neonatal surgeries in the future.

13.
J Med Ultrason (2001) ; 45(4): 629-632, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29396737

RESUMEN

Acute funisitis is characterized by the infiltration of fetal neutrophils from the umbilical vessels into Wharton's jelly and presents as fetal inflammation. However, no reports about its prenatal diagnosis using ultrasonography have been published. We encountered one case of oligohydramnios at 26 weeks and another case of threatened premature delivery at 27 weeks of gestation with ultrasonographic findings of non-uniform thickening of Wharton's jelly, a heterogeneous internal echo, and a high echoic line of the umbilical vessel wall. Acute funisitis was diagnosed, and the postpartum histopathological examination revealed severe funisitis in both cases. To our knowledge, this is the first case report of prenatal diagnosis of funisitis determined using ultrasonography. When we find such ultrasonographic features under the circumstances of intrauterine infection, severe funisitis should be included in the differential diagnosis.


Asunto(s)
Corioamnionitis/diagnóstico por imagen , Ultrasonografía Prenatal , Adulto , Corioamnionitis/patología , Femenino , Humanos , Recién Nacido , Embarazo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...