Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Front Neurol ; 15: 1337230, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38694770

RESUMEN

Introduction: Upper limb rehabilitation assessment plays a pivotal role in the recovery process of stroke patients. The current clinical assessment tools often rely on subjective judgments of healthcare professionals. Some existing research studies have utilized physiological signals for quantitative assessments. However, most studies used single index to assess the motor functions of upper limb. The fusion of surface electromyography (sEMG) and functional near-infrared spectroscopy (fNIRS) presents an innovative approach, offering simultaneous insights into the central and peripheral nervous systems. Methods: We concurrently collected sEMG signals and brain hemodynamic signals during bilateral elbow flexion in 15 stroke patients with subacute and chronic stages and 15 healthy control subjects. The sEMG signals were analyzed to obtain muscle synergy based indexes including synergy stability index (SSI), closeness of individual vector (CV) and closeness of time profile (CT). The fNIRS signals were calculated to extract laterality index (LI). Results: The primary findings were that CV, SSI and LI in posterior motor cortex (PMC) and primary motor cortex (M1) on the affected hemisphere of stroke patients were significantly lower than those in the control group (p < 0.05). Moreover, CV, SSI and LI in PMC were also significantly different between affected and unaffected upper limb movements (p < 0.05). Furthermore, a linear regression model was used to predict the value of the Fugl-Meyer score of upper limb (FMul) (R2 = 0.860, p < 0.001). Discussion: This study established a linear regression model using force, CV, and LI features to predict FMul scale values, which suggests that the combination of force, sEMG and fNIRS hold promise as a novel method for assessing stroke rehabilitation.

2.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 41(1): 90-97, 2024 Feb 25.
Artículo en Chino | MEDLINE | ID: mdl-38403608

RESUMEN

In the process of robot-assisted training for upper limb rehabilitation, a passive training strategy is usually used for stroke patients with flaccid paralysis. In order to stimulate the patient's active rehabilitation willingness, the rehabilitation therapist will use the robot-assisted training strategy for patients who gradually have the ability to generate active force. This study proposed a motor function assessment technology for human upper-limb based on fuzzy recognition on interaction force and human-robot interaction control strategy based on assistance-as-needed. A passive training mode based on the calculated torque controller and an assisted training mode combined with the potential energy field were designed, and then the interactive force information collected by the three-dimensional force sensor during the training process was imported into the fuzzy inference system, the degree of active participation σ was proposed, and the corresponding assisted strategy algorithms were designed to realize the adaptive adjustment of the two modes. The significant correlation between the degree of active participation σ and the surface electromyography signals (sEMG) was found through the experiments, and the method had a shorter response time compared to a control strategy that only adjusted the mode through the magnitude of interaction force, making the robot safer during the training process.


Asunto(s)
Robótica , Rehabilitación de Accidente Cerebrovascular , Accidente Cerebrovascular , Humanos , Robótica/métodos , Extremidad Superior , Algoritmos , Electromiografía/métodos
3.
Med Eng Phys ; 117: 103993, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37331748

RESUMEN

Over the past several decades, many scholars have investigated muscle synergy as a promising tool for evaluating motor function. However, it is challenging to obtain favorable robustness using the general muscle synergy identification algorithms, namely non-negative matrix factorization (NMF), independent component analysis (ICA), and factor analysis (FA). Some scholars have proposed improved muscle synergy identification algorithms to overcome the shortcomings of these approaches, such as singular value decomposition NMF (SVD-NMF), sparse NMF (S-NMF), and multivariate curve resolution-alternating least squares (MCR-ALS). However, performance comparisons of these algorithms are seldom conducted. In this study, experimental electromyography (EMG) data collected from healthy individuals and stroke survivors were applied to assess the repeatability and intra-subject consistency of NMF, SVD-NMF, S-NMF, ICA, FA, and MCR-ALS. MCR-ALS presented higher repeatability and intra-subject consistencies than the other algorithms. More synergies and lower intra-subject consistencies were observed in stroke survivors than in healthy individuals. Thus, MCR-ALS is considered a favorable muscle synergy identification algorithm for patients with neural system disorders.


Asunto(s)
Músculo Esquelético , Accidente Cerebrovascular , Humanos , Músculo Esquelético/fisiología , Electromiografía , Accidente Cerebrovascular/complicaciones , Algoritmos
4.
Acta Radiol ; 64(1): 228-236, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34964365

RESUMEN

BACKGROUND: Measurement of bone mineral density (BMD) is the most important method to diagnose osteoporosis. However, current BMD measurement is always performed after a fracture has occurred. PURPOSE: To explore whether a radiomic model based on abdominal computed tomography (CT) can predict the BMD of lumbar vertebrae. MATERIAL AND METHODS: A total of 245 patients who underwent both dual-energy X-ray absorptiometry (DXA) and abdominal CT examination (training cohort, n = 196; validation cohort, n = 49) were included in our retrospective study. In total, 1218 image features were extracted from abdominal CT images for each patient. Combined with clinical information, three steps including least absolute shrinkage and selection operator (LASSO) regression were used to select key features. A two-tier stacking regression model with multi-algorithm fusion was used for BMD prediction, which can integrate the advantages of linear model and non-linear model. The prediction results of this model were compared with those using a single regressor. The degree-of-freedom adjusted coefficient of determination (Adjusted-R2), root mean square error (RMSE), and mean absolute error (MAE) were used to evaluate the regression performance. RESULTS: Compared with other regression methods, the two-tier stacking regression model has a higher regression performance, with Adjusted-R2, RMSE, and MAE of 0.830, 0.077, and 0.06, respectively. Pearson correlation analysis and Bland-Altman analysis showed that the BMD predicted by the model had a high correlation with the DXA results (r = 0.932, difference = -0.01 ± 0.1412 mg/cm2). CONCLUSION: Using radiomics, the BMD of lumbar vertebrae could be predicted from abdominal CT images.


Asunto(s)
Densidad Ósea , Osteoporosis , Humanos , Estudios Retrospectivos , Osteoporosis/diagnóstico por imagen , Absorciometría de Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Vértebras Lumbares/diagnóstico por imagen
5.
Sensors (Basel) ; 21(11)2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-34205957

RESUMEN

In this paper, we present a novel muscle synergy extraction method based on multivariate curve resolution-alternating least squares (MCR-ALS) to overcome the limitation of the nonnegative matrix factorization (NMF) method for extracting non-sparse muscle synergy, and we study its potential application for evaluating motor function of stroke survivors. Nonnegative matrix factorization (NMF) is the most widely used method for muscle synergy extraction. However, NMF is susceptible to components' sparseness and usually provides inferior reliability, which significantly limits the promotion of muscle synergy. In this study, MCR-ALS was employed to extract muscle synergy from electromyography (EMG) data. Its performance was compared with two other matrix factorization algorithms, NMF and self-modeling mixture analysis (SMMA). Simulated data sets were utilized to explore the influences of the sparseness and noise on the extracted synergies. As a result, the synergies estimated by MCR-ALS were the most similar to true synergies as compared with SMMA and NMF. MCR-ALS was used to analyze the muscle synergy characteristics of upper limb movements performed by healthy (n = 11) and stroke (n = 5) subjects. The repeatability and intra-subject consistency were used to evaluate the performance of MCR-ALS. As a result, MCR-ALS provided much higher repeatability and intra-subject consistency as compared with NMF, which were important for the reliability of the motor function evaluation. The stroke subjects had lower intra-subject consistency and seemingly had more synergies as compared with the healthy subjects. Thus, MCR-ALS is a promising muscle synergy analysis method for motor function evaluation of stroke patients.


Asunto(s)
Músculo Esquelético , Accidente Cerebrovascular , Electromiografía , Humanos , Proyectos Piloto , Reproducibilidad de los Resultados
6.
Sensors (Basel) ; 21(13)2021 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-34203331

RESUMEN

Time synchronization is the basis of many applications. Aiming at the limitations of the existing clock synchronization algorithms in underwater wireless sensor networks, we propose a pairwise synchronization algorithm called K-Sync, which is based on the Kalman filter. The algorithm does not need the assistance of the position sensor or the speed sensor, and the high time synchronization accuracy can be realized only by utilizing the time-stamps information in the process of message exchange. The K-Sync uses the general constraints of the motion characteristics of the sensor nodes to establish the recursive equations of the clock skew, clock offset, relative mobility velocity, and relative distance. At the same time, the time-stamps are viewed as the observation variables and the system observation equation is obtained. The K-Sync estimates the normalized clock skew and offset of the node via the Kalman filter to achieve high-precision clock synchronization between the two nodes. The simulation shows that the K-Sync has obvious advantages in the key indicators such as the estimated accuracy of clock skew and clock offset, convergence speed, etc. In addition, the K-Sync is more robust to a variety of underwater motion scenes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA