Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Micromachines (Basel) ; 15(6)2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38930728

RESUMEN

In this paper, a sensor using a complementary split ring resonator (CSRR) is proposed for non-destructive testing of blood glucose. By depicting the complementary split ring structure on the ground, the electromagnetic field strength between the split rings can be enhanced effectively. The structure size of the sensor by CSRR is determined by simulation, so that the insertion loss curve of the device has a resonance point at the frequency of 3.419 GHz. With a special holder created by three-dimensional (3D) printing technology, the test platform was established when the concentration of the solution varied from 0 mg/mL to 20 mg/mL. The experimental results indicate that there is an obvious linear relationship between the insertion loss S21 and the glucose concentration at the resonant frequency. Similarly, the measured real part and imaginary part of the S21 both vary with glucose concentration linearly. Based on the above experimental results, the feasibility of the sensor using a CSRR proposed in this paper for non-destructive detection of blood glucose is preliminarily verified.

2.
Sensors (Basel) ; 23(12)2023 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-37420700

RESUMEN

This communication investigated the dust effect on microelectromechanical system (MEMS) thermal wind sensors, with an aim to evaluate performance in practical applications. An equivalent circuit was established to analyze the temperature gradient influenced by dust accumulation on the sensor's surface. The finite element method (FEM) simulation was carried out to verify the proposed model using COMSOL Multiphysics software. In experiments, dust was accumulated on the sensor's surface by two different methods. The measured results indicated that the output voltage for the sensor with dust on its surface was a little smaller than that of the sensor without dust at the same wind speed, which can degrade the measurement sensitivity and accuracy. Compared to the sensor without dust, the average voltage was reduced by about 1.91% and 3.75% when the dustiness was 0.04 g/mL and 0.12 g/mL, respectively. The results can provide a reference for the actual application of thermal wind sensors in harsh environments.


Asunto(s)
Polvo , Sistemas Microelectromecánicos , Polvo/análisis , Viento , Temperatura , Programas Informáticos
3.
Front Bioeng Biotechnol ; 9: 783428, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34778241

RESUMEN

Microfluidic devices in combination with fluorescent microscopy offer high-resolution and high-content platforms to study single-cell morphology, behavior and dynamic process in replicative aging of budding yeast, Saccharomyces cerevisiae. However, a huge mass of recorded images makes the data processing labor-intensive and time-consuming to determine yeast replicative lifespan (RLS), a primary criterion in yeast aging. To address this limitation and pursue label-free RLS assays, electrical impedance spectroscopy (EIS) that can be easily functionalized through microelectrodes in microfluidic devices, was introduced to monitor cell growth and division of budding yeast. Herein, a microfluidic device integrated with EIS biosensor was proposed to perform in-situ impedance measurement of yeast proliferation in single-cell resolution so as to identify the momentary events of daughter dissection from its mother. Single yeast cells were reliably immobilized at the bottleneck-like traps for continuous culturing, during which daughter cells were effectively detached from their mother cells by hydraulic shear forces. Time-lapse impedance measurement was performed every 2 min to monitor the cellular process including budding, division and dissection. By using the K-means clustering algorithm to analyze a self-defined parameter "Dissection Indicator," to our knowledge for the first time, the momentary event of a daughter removing from its mother cell was accurately extracted from EIS signals. Thus, the identification of daughter dissection events based on impedance sensing technology has been validated. With further development, this microfluidic device integrated with electrical impedance biosensor holds promising applications in high-throughput, real-time and label-free analysis of budding yeast aging and RLS.

4.
Sensors (Basel) ; 21(9)2021 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-33946866

RESUMEN

In this paper, a novel 2.5-dimensional (2.5D) flexible wind sensor is proposed based on four differential plate capacitors. This design consists of a windward pillar, two electrode layers, and a support layer, which are all made of polydimethylsiloxane (PDMS) with different Young's moduli. A 2 mm × 2 mm copper electrode array is located on each electrode layer, forming four parallel plate capacitors as the sensitive elements. The wind in the xy-plane tilts the windward pillar, decreasing two capacitances on the windward side and increasing two capacitances on the leeward side. The wind in the z-axis depresses the windward pillar, resulting in an increase of all four capacitances. Experiments demonstrate that this sensor can measure the wind speed up to 23.9 m/s and the wind direction over the full 360° range of the xy-plane. The sensitivities of wind speed are close to 4 fF·m-1·s and 3 fF·m-1·s in the xy-plane and z-axis, respectively.

5.
Sensors (Basel) ; 16(6)2016 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-27338395

RESUMEN

In this paper, a novel 3D model is proposed to describe the temperature distribution of the thermoelectric microwave power sensor. In this 3D model, the heat flux density decreases from the upper surface to the lower surface of the GaAs substrate while it was supposed to be a constant in the 2D model. The power sensor is fabricated by a GaAs monolithic microwave integrated circuit (MMIC) process and micro-electro-mechanical system (MEMS) technology. The microwave performance experiment shows that the S11 is less than -26 dB over the frequency band of 1-10 GHz. The power response experiment demonstrates that the output voltage increases from 0 mV to 27 mV, while the incident power varies from 1 mW to 100 mW. The measured sensitivity is about 0.27 mV/mW, and the calculated result from the 3D model is 0.28 mV/mW. The relative error has been reduced from 7.5% of the 2D model to 3.7% of the 3D model.

6.
Sensors (Basel) ; 15(12): 29871-81, 2015 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-26633398

RESUMEN

For a two-dimensional solid silicon thermal wind sensor with symmetrical structure, the wind speed and direction information can be derived from the output voltages in two orthogonal directions, i.e., the north-south and east-west. However, the output voltages in these two directions will vary linearly with the ambient temperature. Therefore, in this paper, a temperature model to study the temperature effect on the wind direction measurement has been developed. A theoretical analysis has been presented first, and then Finite Element Method (FEM) simulations have been performed. It is found that due to symmetrical structure of the thermal wind sensor, the temperature effects on the output signals in the north-south and east-west directions are highly similar. As a result, the wind direction measurement of the thermal wind sensor is approximately independent of the ambient temperature. The experimental results fit the theoretical analysis and simulation results very well.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...