Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
Sci Immunol ; 9(93): eadi5578, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38427717

RESUMEN

Urinary tract infections (UTIs) account for almost 25% of infections in women. Many are recurrent (rUTI), with patients frequently experiencing chronic pelvic pain and urinary frequency despite clearance of bacteriuria after antibiotics. To elucidate the basis for these bacteria-independent bladder symptoms, we examined the bladders of patients with rUTI. We noticed a notable increase in neuropeptide content in the lamina propria and indications of enhanced nociceptive activity. In mice subjected to rUTI, we observed sensory nerve sprouting that was associated with nerve growth factor (NGF) produced by recruited monocytes and tissue-resident mast cells. Treatment of rUTI mice with an NGF-neutralizing antibody prevented sprouting and alleviated pelvic sensitivity, whereas instillation of native NGF into naïve mice bladders mimicked nerve sprouting and pain behavior. Nerve activation, pain, and urinary frequency were each linked to the presence of proximal mast cells, because mast cell deficiency or treatment with antagonists against receptors of several direct or indirect mast cell products was each effective therapeutically. Thus, our findings suggest that NGF-driven sensory sprouting in the bladder coupled with chronic mast cell activation represents an underlying mechanism driving bacteria-independent pain and voiding defects experienced by patients with rUTI.


Asunto(s)
Mastocitos , Vejiga Urinaria , Humanos , Ratones , Femenino , Animales , Vejiga Urinaria/inervación , Vejiga Urinaria/metabolismo , Factor de Crecimiento Nervioso/metabolismo , Reinfección/complicaciones , Reinfección/metabolismo , Dolor/etiología , Dolor/metabolismo , Dolor/prevención & control
2.
Sci Rep ; 14(1): 3864, 2024 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-38366042

RESUMEN

We aimed to evaluate the feasibility of MR elastography (MRE) using a transpelvic approach. Thirty-one patients who underwent prostate MRE and had a pathological diagnosis were included in this study. MRE was obtained using a passive driver placed at the umbilicus and iliac crests. The shear stiffness, clinical data, and conventional imaging findings of prostate cancer and benign prostatic hyperplasia (BPH) were compared. Inter-reader agreements were evaluated using the intraclass coefficient class (ICC). Prostate MRE was successfully performed for all patients (100% technical success rate). Nineteen cancer and 10 BPH lesions were visualized on MRE. The mean shear stiffness of cancer was significantly higher than that of BPH (5.99 ± 1.46 kPa vs. 4.67 ± 1.54 kPa, p = 0.045). One cancer was detected on MRE but not on conventional sequences. Six tiny cancer lesions were not visualized on MRE. The mean size of cancers that were not detected on MRE was smaller than that of cancers that were visible on MRE (0.8 ± 0.3 cm vs. 2.3 ± 1.8 cm, p = 0.001). The inter-reader agreement for interpreting MRE was excellent (ICC = 0.95). Prostate MRE with transpelvic vibration is feasible without intracavitary actuators. Transpelvic prostate MRE is reliable for detecting focal lesions, including clinically significant prostate cancer and BPH.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hiperplasia Prostática , Neoplasias de la Próstata , Masculino , Humanos , Próstata/diagnóstico por imagen , Vibración , Diagnóstico por Imagen de Elasticidad/métodos , Estudios de Factibilidad , Hiperplasia Prostática/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico por imagen , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos
3.
Materials (Basel) ; 16(11)2023 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-37297150

RESUMEN

The demand for fast-charging lithium-ion batteries (LIBs) with long cycle life is growing rapidly due to the increasing use of electric vehicles (EVs) and energy storage systems (ESSs). Meeting this demand requires the development of advanced anode materials with improved rate capabilities and cycling stability. Graphite is a widely used anode material for LIBs due to its stable cycling performance and high reversibility. However, the sluggish kinetics and lithium plating on the graphite anode during high-rate charging conditions hinder the development of fast-charging LIBs. In this work, we report on a facile hydrothermal method to achieve three-dimensional (3D) flower-like MoS2 nanosheets grown on the surface of graphite as anode materials with high capacity and high power for LIBs. The composite of artificial graphite decorated with varying amounts of MoS2 nanosheets, denoted as MoS2@AG composites, deliver excellent rate performance and cycling stability. The 20-MoS2@AG composite exhibits high reversible cycle stability (~463 mAh g-1 at 200 mA g-1 after 100 cycles), excellent rate capability, and a stable cycle life at the high current density of 1200 mA g-1 over 300 cycles. We demonstrate that the MoS2-nanosheets-decorated graphite composites synthesized via a simple method have significant potential for the development of fast-charging LIBs with improved rate capabilities and interfacial kinetics.

4.
PLoS Pathog ; 19(5): e1011388, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37167325

RESUMEN

There is a growing consensus that a significant proportion of recurrent urinary tract infections are linked to the persistence of uropathogens within the urinary tract and their re-emergence upon the conclusion of antibiotic treatment. Studies in mice and human have revealed that uropathogenic Escherichia coli (UPEC) can persist in bladder epithelial cells (BECs) even after the apparent resolution of the infection. Here, we found that, following the entry of UPEC into RAB27b+ fusiform vesicles in BECs, some bacteria escaped into the cytoplasmic compartment via a mechanism involving hemolysin A (HlyA). However, these UPEC were immediately recaptured within LC3A/B+ autophagosomes that matured into LAMP1+ autolysosomes. Thereafter, HlyA+ UPEC-containing lysosomes failed to acidify, which is an essential step for bacterial elimination. This lack of acidification was related to the inability of bacteria-harboring compartments to recruit V-ATPase proton pumps, which was attributed to the defragmentation of cytosolic microtubules by HlyA. The persistence of UPEC within LAMP1+ compartments in BECs appears to be directly linked to HlyA. Thus, through intravesicular instillation of microtubule stabilizer, this host defense response can be co-opted to reduce intracellular bacterial burden following UTIs in the bladder potentially preventing recurrence.


Asunto(s)
Infecciones por Escherichia coli , Infecciones Urinarias , Escherichia coli Uropatógena , Animales , Ratones , Humanos , Vejiga Urinaria/microbiología , Escherichia coli Uropatógena/fisiología , Proteínas Hemolisinas , Infecciones por Escherichia coli/microbiología , Infecciones Urinarias/microbiología , Células Epiteliales/microbiología , Lisosomas/patología , Concentración de Iones de Hidrógeno
5.
Asian J Surg ; 46(1): 472-477, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35691801

RESUMEN

OBJECTIVE: To describe surgical technique for single port robotic surgery using the da Vinci SP system and report the perioperative outcomes. PATIENTS AND METHODS: Between Jan 2019 and Jan 2021, single-port robotic urologic surgeries were performed in 120 patients by a single surgeon. Clinicopathologic data and perioperative outcomes were collected. All surgical procedures were performed with a transperitoneal approach through an umbilical single port. Additional assistant port was used in complex procedures for malignant disease. Surgeries were carried out using both above and below camera position for effective retraction. For reconstructive surgery using intestine, an extra-intracorporeal hybrid method was used. Surgical procedures involving both kidney and pelvis were performed without change of patient position or trocar placement. RESULTS: Mean age was 62.7 years and 102 patients were male. For oncologic indication, 105 patients underwent surgeries including 66 radical prostatectomy, 25 partial nephrectomy, six radical nephrectomies, five nephroureterectomy and three radical cystectomy with urinary diversion. Fifteen cases with benign indication included four ureterolithotomy, seven uretero/pyeloplasty, three ureteroneocystostomy, and one ileal ureter reconstruction. All surgeries were performed successfully without conversion to other surgical approach. Clavien-Dindo grade III complication occurred in two patients. CONCLUSIONS: The da Vinci SP system provides a new robotic surgical platform for single port surgery while maintaining the major features of robotic surgery similar to multi-port surgery. Various single port urologic surgeries can be safely performed with this platform.


Asunto(s)
Procedimientos Quirúrgicos Robotizados , Derivación Urinaria , Urología , Humanos , Masculino , Persona de Mediana Edad , Femenino , Procedimientos Quirúrgicos Robotizados/métodos , Prostatectomía/métodos , Procedimientos Quirúrgicos Urológicos
6.
Int Neurourol J ; 26(2): 119-128, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35793990

RESUMEN

PURPOSE: DA-8010 is a novel muscarinic M3 receptor antagonist with significant selectivity for bladder over salivary gland in preclinical studies. We evaluated the clinical efficacy and safety of DA-8010 in overactive bladder (OAB) patients. METHODS: This phase 2, randomized, double-blind, parallel-group, active reference- and placebo-controlled trial was conducted at 12 centers in South Korea (NCT03566134). Patients aged ≥19 years with OAB symptoms for ≥3 months were enrolled. Three hundred six patients (30.07% male) were randomized to 12 weeks of treatment among 4 groups; 2 experimental groups (DA-8010 2.5 or 5 mg), an active reference group (solifenacin 5 mg), and a placebo group. The change from the baseline of (=∆) 24-hour frequency at 12 weeks (primary endpoint), episodes of urgency, overall/urgency urinary incontinence, average/ maximum voided volume, nocturia, and patients' subjective responses were analyzed. RESULTS: In the full analysis set, the mean (standard deviation) [median] values for ∆ 24-hour frequency at 12 weeks were -1.01 (2.44) [-1.33] for placebo, -1.22 (2.05) [-1.33] for DA-8010 2.5 mg, and -1.67 (2.25) [-1.67] for DA-8010 5 mg; DA-8010 5 mg showed a significant decrease compared with placebo (P=0.0413). At 4 and 8 weeks, both DA-8010 2.5 mg (P=0.0391 at 4 weeks, P=0.0335 at 8 weeks) and DA-8010 5 mg (P=0.0001 at 4 weeks, P=0.0210 at 8 weeks) showed significant decrease in ∆ 24-hour frequency compared with placebo. DA-8010 5 mg achieved a significant decrease in ∆ number of urgency episodes, compared with placebo at 4 (P=0.0278) and 8 (P=0.0092) weeks. Adverse drug reactions (ADRs) were observed in 3.95% of placebo, 6.67% of DA-8010 2.5 mg, 18.42% of DA-8010 5 mg, and 17.33% of solifenacin 5 mg groups. No serious ADRs were observed in any patient. CONCLUSION: Both DA-8010 2.5 mg and 5 mg showed therapeutic efficacy for OAB without serious ADRs. Therefore, both dosages of DA-8010 can advance to a subsequent large-scale phase 3 trial.

7.
World J Urol ; 40(8): 2071-2076, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35704106

RESUMEN

PURPOSE: In Hunner-type interstitial cystitis/bladder pain syndrome (IC/BPS), it is unclear whether suburothelial afferents underlying normal-appearing background areas contribute to symptom development. We examined whether adding hydrodistension (HD) to transurethral fulguration (TUF) of Hunner lesions, for the purpose of treating the background areas, is superior to TUF alone. METHODS: This randomized controlled trial included 52 patients with Hunner-type IC/BPS allocated at a 1:1 (TUF:TUF+HD) ratio. HD was performed at 80 cmH2O for 8 min before TUF in the TUF+HD group. Thirty-three patients remained until the end of the 6-month observational period. The primary endpoint was the visual analogue scale (VAS) pain score at 1 month. Major secondary endpoints were the treatment-failure rate, VAS pain scores at ≥ 2 months, and frequency-volume chart parameters. RESULTS: Both TUF and TUF+HD showed significant improvement in VAS pain score at 1 month (95% confidence interval [CI]: - 1.62 to 0.16, P = 0.106). VAS pain scores were significantly lower in TUF+HD than TUF at 2 (95% CI: - 1.97 to - 0.28, P = 0.011), 4 (95% CI: - 2.83 to - 0.72, P = 0.002), and 6 (95% CI: - 3.11 to - 0.07, P = 0.040) months. Treatment-failure rate was higher in TUF (36.4%) than TUF+HD (17.4%), without significance (odds ratio: 2.714, 95% CI: 0.68 to 10.84, P = 0.189). Functional capacity and urgency were not significantly different between groups. CONCLUSION: The addition of HD to TUF tended to be superior to TUF monotherapy for controlling pain in Hunner-type IC/BPS. This indicates that not only Hunner lesions but also normal-appearing background areas may have a role in the pain of IC/BPS. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT03987594, date of registration: 2019-06-17 (retrospectively registered).


Asunto(s)
Cistitis Intersticial , Cistitis Intersticial/complicaciones , Humanos , Dolor , Estudios Prospectivos , Insuficiencia del Tratamiento
8.
Int Neurourol J ; 26(Suppl 1): S1-7, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35236047

RESUMEN

PURPOSE: Overactive bladder (OAB) is observed in women with functional bladder outlet obstruction (FBOO), as are lower urinary tract symptoms (LUTS). Therefore, we evaluated the urodynamic characteristics of women with storage LUTS and FBOO diagnosed by urodynamic studies (UDS). METHODS: Women (n=108) with storage LUTS and FBOO diagnosed by UDS were included in this study. The urodynamic characteristics of women with FBOO were compared with those of women with OAB (n=34) and stress urinary incontinence (SUI, n=78). FBOO was defined as a maximum flow rate (Qmax) < 15 mL/sec, combined with detrusor pressure at a Qmax (PdetQmax) > 20 cm H2O in a pressure-flow study. The UDS included uroflowmetry, postvoid residual volume determination, a cystometrogram, and a pressure-flow study. RESULTS: Women with FBOO who had storage symptoms showed a higher PdetQmax and maximum urethral closing pressure (MUCP) than women with OAB and SUI. Interstitial cystitis/bladder pain syndrome (IC/BPS) was observed in 17.6% of women with FBOO. MUCP was significantly higher in women with BOO than in women with BOO and IC/BPS (115.6±27.4 and 96.6±14.1 cm H2O, P=0.00). The receiver operating characteristic curve analysis showed that the cutoff values of MUCP in women with FBOO compared to women with OAB and SUI were 87 cm H2O (sensitivity=81.5%, specificity=73.5%) and 36 cm H2O (sensitivity=92.6%, specificity=84.4%), respectively. The cutoff value of MUCP in women with FBOO compared to women with FBOO and IC/BPS was 92 cm H2O (sensitivity=85.4%, specificity=78.9%). CONCLUSION: MUCP could have predictive value for identifying FBOO in women with complex LUTS.

9.
Nano Lett ; 22(4): 1726-1733, 2022 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-35133170

RESUMEN

A rechargeable aluminum-ion battery based on chloroaluminate electrolytes has received intense attention due to the high abundance and chemical stability of aluminum. However, the fundamental intercalation processes and dynamics in these battery systems remain unresolved. Here, the energetics and dynamics of chloroaluminate ion intercalation in atomically thin single crystal graphite are investigated by fabricating mesoscopic devices for charge transport and operando optical microscopy. These mesoscopic measurements are compared to the high-performance rechargeable Al-based battery consisting of a few-layer graphene-multiwall carbon nanotube composite cathode. These composites exhibit a 60% capacity enhancement over pyrolytic graphite, while an ∼3-fold improvement in overall ion diffusivity is also obtained exhibiting ∼1% of those in atomically thin single crystals. Our results thus establish the distinction between intrinsic and ensemble electrochemical behavior in Al-based batteries and show that engineering ion transport in these devices can yet lead to vast improvements in battery performance.

10.
Adv Mater ; 34(14): e2109767, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35133699

RESUMEN

Sodium-metal batteries (SMBs) are considered as a compliment to lithium-metal batteries for next-generation high-energy batteries because of their low cost and the abundance of sodium (Na). Herein, a 3D nanostructured porous carbon particle containing carbon-shell-coated Fe nanoparticles (PC-CFe) is employed as a highly reversible Na-metal host. PC-CFe has a unique 3D hierarchy based on sub-micrometer-sized carbon particles, ordered open channels, and evenly distributed carbon-coated Fe nanoparticles (CFe) on the surface. PC-CFe achieves high reversibility of Na plating/stripping processes over 500 cycles with a Coulombic efficiency of 99.6% at 10 mA cm-2 with 10 mAh cm-2 in Na//Cu asymmetric cells, as well as over 14 400 cycles at 60 mA cm-2 in Na//Na symmetric cells. Density functional theory calculations reveal that the superior cycling performance of PC-CFe stems from the stronger adsorption of Na on the surface of the CFe, providing initial nucleation sites more favorable to Na deposition. Moreover, the full cell with a PC-CFe host without Na metal and a high-loading Na3 V2 (PO4 )3 cathode (10 mg cm-2 ) maintains a high capacity of 103 mAh g-1 at 1 mA cm-2 even after 100 cycles, demonstrating the operation of anode-free SMBs.

11.
Sci Rep ; 11(1): 19830, 2021 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-34615962

RESUMEN

Endosomal trafficking of cell surface receptors is essential to their function. Integrins are transmembrane receptors that integrate adhesion to the extracellular matrix with engagement of the cytoskeleton. Ligated integrins mediate diverse signals that regulate matrix assembly, cell survival, cell morphology, and cell motility. Endosomal trafficking of integrins modulates these signals and contributes to cell motility and is required for cancer cell invasion. The phosphoprotein PEA-15 modulates integrin activation and ERK MAP Kinase signaling. To elucidate novel PEA-15 functions we utilized an unbiased proteomics approach. We identified several binding partners for PEA-15 in the endosome including clathrin and AP-2 as well as integrin ß1 and other focal adhesion complex proteins. We confirmed these interactions using proximity ligation analysis, immunofluorescence imaging, pull-down and co-immunoprecipitation. We further found that PEA-15 is enriched in endosomes and was required for efficient endosomal internalization of α5ß1 integrin and cellular migration. Importantly, PEA-15 promotion of migration was dependent on PEA-15 phosphorylation at serines 104 and 116. These data support a novel endosomal role for PEA-15 in control of endosomal trafficking of integrins through an association with the ß1 integrin and clathrin complexes, and thereby regulation of cell motility.


Asunto(s)
Proteínas Reguladoras de la Apoptosis/metabolismo , Endocitosis/fisiología , Endosomas/metabolismo , Integrina alfa5beta1/metabolismo , Fosfoproteínas/metabolismo , Proteínas Reguladoras de la Apoptosis/genética , Adhesión Celular , Línea Celular Tumoral , Humanos , Espectrometría de Masas , Proteómica/métodos
12.
Materials (Basel) ; 14(16)2021 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-34443205

RESUMEN

Graphite is used as a state-of-the-art anode in commercial lithium-ion batteries (LIBs) due to its highly reversible lithium-ion storage capability and low electrode potential. However, graphite anodes exhibit sluggish diffusion kinetics for lithium-ion intercalation/deintercalation, thus limiting the rate capability of commercial LIBs. In order to determine the lithium-ion diffusion coefficient of commercial graphite anodes, we employed a galvanostatic intermittent titration technique (GITT) to quantify the quasi-equilibrium open circuit potential and diffusion coefficient as a function of lithium-ion concentration and potential for a commercial graphite electrode. Three plateaus are observed in the quasi-equilibrium open circuit potential curves, which are indicative of a mixed phase upon lithium-ion intercalation/deintercalation. The obtained diffusion coefficients tend to increase with increasing lithium concentration and exhibit an insignificant difference between charge and discharge conditions. This study reveals that the diffusion coefficient of graphite obtained with the GITT (1 × 10-11 cm2/s to 4 × 10-10 cm2/s) is in reasonable agreement with literature values obtained from electrochemical impedance spectroscopy. The GITT is comparatively simple and direct and therefore enables systematic measurements of ion intercalation/deintercalation diffusion coefficients for secondary ion battery materials.

14.
Diagnostics (Basel) ; 10(4)2020 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-32325682

RESUMEN

Urinary cell-free DNA (cfDNA) is an attractive body fluid for liquid biopsy. In this study, we compared the efficiencies of four commercial kits for urinary cell-free DNA (cfDNA) isolation and of various sample storage conditions. Urinary cfDNA was isolated from 10 healthy individuals using four commercial kits: QIAamp Circulating Nucleic Acid Kit (QC; Qiagen), MagMAX™ Cell-Free DNA Isolation Kit (MM; Applied Biosystems), Urine Cell-Free Circulating DNA Purification Midi Kit (NU; Norgen Biotek), and Quick-DNA™ Urine Kit (ZQ; Zymo Research). To assess the isolation efficiency, an Agilent 2100 Bioanalyzer with High Sensitivity DNA chips was used, and cfDNA yield was defined as the amount of cfDNA obtained from 1 mL of urine. MM and QC provided the highest cfDNA yield in the 50-300 bp range, and MM and NU gave the highest cfDNA yield in the 50-100 bp range. In particular, the NU kit was efficient for isolation of more fragmented cfDNA in the range of 50-100 bp with the lowest cellular genomic DNA contamination. ZQ had the best cost-efficiency for isolating the same amount of urinary cfDNA. Samples stored at -70 °C with the addition of 10 mM EDTA resulted in the highest cfDNA yield 3 months after sample collection.

15.
Investig Clin Urol ; 61(2): 173-179, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32158968

RESUMEN

Purpose: To report an initial single-surgeon experience with single-port robot-assisted radical prostatectomy (SP-RARP) using the da Vinci SP surgical system (Intuitive Surgical, USA). Materials and Methods: Between December 2018 and October 2019, a single surgeon performed SP-RARP in 20 patients with prostate cancer. SP-RARP was performed using the conventional approach through an umbilical port with a GelPOINT access system (Applied Medical, USA) and an additional assist port. During surgery, the camera was placed in the 6- or 12-o'clock position, and a traction arm was placed in the counterpart position for upward or downward traction. Clinicopathologic data, perioperative data, and short-term surgical outcomes were analyzed. Results: Of 20 patients, 45% of patients had pT3 or greater disease and 45% had Gleason grade 4 to 5, respectively. In 11 patients that underwent lymph node dissection, the median number of lymph nodes removed was 19 (interquartile range [IQR], 14-22). Median operative time was 245 minutes (IQR, 200-255), and median console time was 190 minutes (IQR, 165-210). Median blood loss was 200 mL (IQR, 150-300 mL), and there were no intraoperative complications or open conversion. In 10 patients with a follow-up period longer than 3 months, one patient experienced biochemical recurrence, and all patients required 0 to 1 pads per day. Of seven patients that were potent before surgery, four recovered erectile function sufficient for intercourse. Conclusions: Our report shows the safety and feasibility of SP-RARP, and that the associated surgical outcomes with short-term follow-up are satisfactory.


Asunto(s)
Prostatectomía/métodos , Neoplasias de la Próstata/cirugía , Procedimientos Quirúrgicos Robotizados/instrumentación , Anciano , Diseño de Equipo , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
16.
PLoS One ; 15(3): e0229836, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32160209

RESUMEN

BACKGROUND AND PURPOSE: We hypothesized that admission insular infarcts could be associated with early neurological deterioration (END) in acute minor stroke with large vessel occlusion. METHODS: Using acute and follow-up diffusion-weighted imaging (DWI), we assessed insular involvement including the percent insular ribbon infarction (PIRI) scores and follow-up lesion patterns in acute minor stroke (NIHSS ≤5) with MCA/ICA occlusion. Follow-up lesion patterns were classified as swelling, new lesions, or infarct growth. END was defined as any increase in the NIHSS score. RESULTS: Among 166 patients (age: 66±12 y, 60.8% male), 82 (49.4%) had insular lesions on baseline DWI, and 64 (38.6%) had PIRI scores ≥2. On follow-up DWI, infarct growths, new lesions, and swelling were observed in 34.9%, 69.9%, and 29.5% of patients. Infarct growths were significantly more frequent in patients with insular infarcts (43.9%), especially those with a PIRI score of 2 (54.8%), than in patients without insular infarcts (p = 0.02). While END was not significantly different in patients with and without insular lesions, insular lesions were independently associated with infarct growths (OR 2.18, 95% CI 1.12-4.26, p = 0.02) and END due to infarct growth (OR 2.54, 95% CI 1.12-5.76, p = 0.03), particularly in those with PIRI scores ≥2. CONCLUSION: In acute minor stroke with MCA/ICA occlusion, insular lesions on admission DWI, especially in patients with PIRI scores ≥2, were more likely to exhibit infarct growth and END due to infarct growth. This finding may help identify patients with higher risks of clinical worsening following acute minor stroke with large vessel occlusion.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Infarto de la Arteria Cerebral Media/diagnóstico por imagen , Infarto de la Arteria Cerebral Media/patología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
17.
Urol J ; 17(1): 97-101, 2020 01 26.
Artículo en Inglés | MEDLINE | ID: mdl-30882160

RESUMEN

PURPOSE: We investigated treatment satisfaction with flexible-dose fesoterodine in patients with overactive bladder (OAB) who were dissatisfied with previous anticholinergic therapy. MATERIALS AND METHODS: The subjects were prescribed fesoterodine 4 mg for 4 weeks and fesoterodine 4 mg or 8 mg for another 8 weeks. The primary end point of this study was patients' satisfaction after 12 weeks of fesoterodine treatment on a five-point Likert scale. Secondary end points included a change in the number of daytime micturition, urgency incontinence episodes, urgency episodes, and nocturnal micturition in a 24-hour period from baseline to final assessment. RESULTS: Overall, 84 patients were assigned to the treatment group in this study and 63 patients completed the 12-week treatment course. A final fesoterodine dose of 4 mg and 8 mg was used by 45 (71.4%) and 18 (28.6%) patients, respectively. The satisfaction and dissatisfaction rates at 12 weeks were 69.9% and 14.2%, respectively. Mean changes in the daytime micturitions (9.73 ± 4.72 vs. 7.76 ± 2.86), urgency episodes (7.73 ± 5.68 vs. 3.71 ± 4.09), and nocturnal micturitions (2.13 ± 1.36 vs. 1.68 ± 1.12) in 24 hours improved significantly with flexible-dose fesoterodine treatment (P < .05). Most adverse events were mild and none were severe. CONCLUSION: The flexible dose fesoterodine represents an alternative treatment modality in patients with OAB who are dissatisfied with previous anticholinergic therapy in Korea.


Asunto(s)
Compuestos de Bencidrilo/administración & dosificación , Antagonistas Muscarínicos/uso terapéutico , Satisfacción del Paciente , Vejiga Urinaria Hiperactiva/tratamiento farmacológico , Agentes Urológicos/administración & dosificación , Adulto , Anciano , Anciano de 80 o más Años , Compuestos de Bencidrilo/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Nocturia/etiología , Estudios Prospectivos , Retratamiento , Vejiga Urinaria Hiperactiva/complicaciones , Incontinencia Urinaria de Urgencia/etiología , Micción , Agentes Urológicos/efectos adversos
18.
Sci Rep ; 9(1): 15914, 2019 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-31685903

RESUMEN

Metal-assisted chemical etching (MACE) has been widely explored for developing silicon (Si)-based energy and optical devices with its benefits for low-cost and large-area fabrication of Si nanostructures of high aspect ratios. Surface structures and properties of Si nanostructures fabricated through MACE are significantly affected by experimental and environmental conditions of etchings. Herein, we showed that surfaces and interfacial energy states of fabricated Si nanowires can be critically affected by oxidants of MACE etching solutions. Surfaces of fabricated Si nanowires are porous and their tips are fully covered with lots of Si nano-sized grains. Strongly increased photoluminescence (PL) intensities, compared to that of the crystalline Si substrate, are observed for MACE-fabricated Si nanowires due to interfacial energy states of Si and SiOx of Si nano-sized grains. These Si grains can be completely removed from the nanowires by an additional etching process of the anisotropic chemical etching (ACE) of Si to taper the nanowires and enhance light trapping of the nanowires. Compared with the MACE-fabricated Si nanowires, ACE-fabricated tapered Si nanowires have similar Raman and PL spectra to those of the crystalline Si substrate, indicating the successful removal of Si grains from the nanowire surfaces by the ACE process.

19.
BMC Urol ; 19(1): 47, 2019 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-31170952

RESUMEN

Interstitial cystitis/bladder pain syndrome (IC/BPS) and female sexual dysfunction (FSD) are common conditions that substantially reduce women's health. In particular, women with IC/BPS show vulvodynia, a kind of FDS that originates from consistent pain around the vulvar area. There have been many studies attempting to find the underlying mechanisms that induce the chronic pain associated with IC/BPS and vulvodynia and explain why these two conditions often coexist. Proposed theories suggest that pain hypersensitivity is being mediated by peripheral and central sensitization. However, there are still many unknown factors, such as etiologies, that can evoke pain hypersensitivity and may be linking the casual relationship between IC/BPS and vulvodynia. At present, knowledge regarding IC/BPS and vulvodynia are insufficient when considering their clinical importance. Therefore, efforts are necessary to elucidate the issues surrounding IC/BPS and vulvodynia.


Asunto(s)
Cistitis Intersticial/complicaciones , Vulvodinia/etiología , Femenino , Humanos
20.
Water Res ; 151: 252-259, 2019 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-30605773

RESUMEN

Flow-electrode-based capacitive deionization (FCDI) has attracted much attention owing to its continuous and scalable desalination process without the need for a discharging step, which is required in conventional fixed-electrode capacitive deionization. However, flow electrode slurry is poorly conductive, which restricts desalination performance, but higher carbon mass loading in the slurry could improve salt removal capacity due to enhanced connectivity. However, increased viscosity restricts higher loading of active materials. Herein, we report a significant increase in salt removal performance by introducing functionalized carbon nanotubes (FCNTs) into activated carbon (AC)-based flow electrodes, which led to the generation of conducting bridges between AC particles. The salt removal rate in the presence of 0.25 wt% FCNT with 5 wt% AC improved four-fold from that obtained with only 5 wt% AC, which is the highest value reported in the literature so far (from 1.45 to 5.72 mmol/m2s, at a saline water concentration of 35.0 g/L and applied potential of 1.2 V). Further, FCNTs with a high aspect ratio (∼50,000) can more effectively enhance salt removal than low-aspect ratio FCNTs (∼1300). Electrochemical analysis further confirms that the addition of FCNTs can efficiently form a connecting percolation network, thus enhancing the conductivity of the flow electrode slurry for the practical application of highly efficient desalination systems.


Asunto(s)
Nanotubos de Carbono , Purificación del Agua , Carbón Orgánico , Electrodos , Cloruro de Sodio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...