Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Ann Lab Med ; 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38639011

RESUMEN

Pseudothrombocytopenia caused by platelet clumping (PC) can lead to unnecessary platelet transfusions or underdiagnosis of hematologic neoplasms. To overcome these limitations, we assessed the capacity of the Sysmex DI-60 digital morphology analyzer (Sysmex, Kobe, Japan) for detecting PC and determining an accurate platelet count in the presence of PC. For this purpose, 135 samples with or without PC (groups Y and N, respectively) were processed by an examiner (a hematologic specialist) using both the Sysmex XN-9000 and DI-60 analyzers. Although the platelet aggregate (PA) and giant platelet (GP) counts reported by the DI-60 and the examiner exhibited strong correlations, they proved inadequate as effective indicators for screening samples containing PC. Between the PA and GP counts and four platelet indices (the platelet distribution width [PDW], mean platelet volume [MPV], platelet large cell ratio [P_LCR], and plateletcrit [PCT]) reported by the XN-9000, we observed statistically significant correlations (both overall and with group Y), but they were relatively weak. The platelet counts determined using the DI-60 and light microscopy in group Y showed substantial variations. Although the performance of the DI-60 was reliable for detecting PA and GP in smear images, such fixed areas are not representative of whole samples. Further, in the presence of PC, the resulting platelet counts determined using the DI-60 were not sufficiently accurate to be accepted as the final count.

2.
Genes (Basel) ; 14(10)2023 09 26.
Artículo en Inglés | MEDLINE | ID: mdl-37895222

RESUMEN

Although Genome Reference Consortium Human Build 38 (GRCh38) was released with improvement over GRCh37, it has not been widely adopted. Several liftover tools have been developed as a convenient approach for GRCh38 implementation. This study aimed to investigate the accuracy of liftover tools for genome conversion. Two Variant Call Format (VCF) files aligned to GRCh37 and GRCh38 were downloaded from ClinVar (clinvar_20221217.vcf.gz). Liftover tools such as CrossMap, NCBI Remap, and UCSC liftOver were used to convert genome coordinates from GRCh37 to GRCh38. The accuracy of CrossMap, NCBI Remap, and UCSC liftOver were 99.81% (1,567,838/1,570,748), 99.69% (1,565,953/1,570,748), and 99.99% (1,570,550/1,570,748), respectively. Variants that failed conversion via all three liftover tools were all indels/duplications: a pathogenic/likely pathogenic variant (n = 1) and benign/likely benign variants (n = 7). The eight variants that failed conversion were identified in the ALMS, TTN, CFTR, SLCO, LDLR, PCNT, MID1, and GRIA3 genes, and all the variants were not in the VCF files aligned to GRCh37. This study demonstrated that three liftover tools could successfully convert reference genomes from GRCh37 to GRCh38 in more than 99% of ClinVar variants. This study takes the first step to clinically implement GRCh38 using liftover tools. Further clinical studies are warranted to compare the performance of liftover tools and to validate re-alignment approaches in routine clinical settings.


Asunto(s)
Genoma Humano , Humanos
3.
Exp Clin Endocrinol Diabetes ; 131(4): 216-221, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36854385

RESUMEN

BACKGROUND: Newborn screening for congenital adrenal hyperplasia (CAH) has benefits with a high adoption rate worldwide. It also has problems of high false positives, which can cause stress to the patient's family with economic losses and unnecessary visits of newborns to hospitals. Therefore, we investigated the influence of birth weight (BW), gestational age (GA), and GA with sampling time on 17-hydroxyprogesterone (17-OHP) concentration and attempted to establish the 17-OHP cutoff values in preterm, low birth weight (LBW), and sick newborns. METHODS: Newborns (n=1,071) born between October 2020 and January 2022 were screened for CAH. Samples from neonates were collected on filter paper with the heel prick method. 17-OHP concentration was measured by time-resolved immunofluorescence with an AutoDELFIA Neonatal 17-hydroxyprogesteron kit and grouped in relation to BW, GA, and GA with sampling time. RESULTS: The median age of newborns at neonatal sample collection was 6 days. 17-OHP concentration showed a statistically significant negative correlation with BW (r=-0.488, p<0.001) and GA (r=-0.560, p<0.001). Full-term and preterm subgroups had a similar decreasing tendency of 17-OHP concentration with increasing sampling time. Application of newly establishing cutoff criteria significantly reduced recall rates to 1.16%, 0.9%, and 1.75% according to each criterion of BW, GA, and GA with sampling time, respectively. CONCLUSIONS: This study presents new 17-OHP cutoff values for preterm, LBW, and sick newborns. These data in our laboratory can be used as a reference by other laboratories for establishing new cutoff criteria to help lower the high recall rate and reduce unnecessary follow-up tests.


Asunto(s)
Hiperplasia Suprarrenal Congénita , Humanos , Recién Nacido , Hiperplasia Suprarrenal Congénita/diagnóstico , 17-alfa-Hidroxiprogesterona , Peso al Nacer , Tamizaje Neonatal/métodos , Recién Nacido de Bajo Peso
4.
Ann Lab Med ; 43(2): 187-195, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36281513

RESUMEN

Background: The selective leukoreduction protocol (SLP) is limited in that patients who require it can be overlooked. We estimated SLP compliance (SLPC) using the Observational Medical Outcomes Partnership common data model (CDM). Methods: Patients were classified into eight groups: pre- and post-hematology disease (A and B), pre- and post-solid organ transplantation (C and D), solid cancer (E), immunodeficiency (F), anticancer therapy (G), and cardiovascular surgery (H). We examined the red blood cell (RBC) transfusion history from three hospital datasets comprising approximately three million patients over 20 years using CDM-based analysis. SLPC was calculated as the percentage of patients who received only leukoreduced RBCs in total patients transfused RBCs. Results: In total, 166,641 patients from three hospitals were enrolled in this study. From 2001 to 2021, SLPC in all groups, except H, tended to increase, although there were differences among the hospitals. Based on the most recent values (2017-2021), the SLPC in groups A, B, D, and G was maintained at ≥75% until 1,095 days before or after diagnosis or treatment. Groups E, F, and H had < 50% SLPC one day after diagnosis and treatment. Conclusions: CDM analysis supports the review of large datasets for SLPC evaluation. Although SLPC tended to improve in most patient groups, additional education and monitoring are needed for groups that continue to show low SLPC.


Asunto(s)
Transfusión de Eritrocitos , Adhesión a Directriz , Humanos , Transfusión de Eritrocitos/métodos , Eritrocitos , Hospitales
5.
Hematology ; 27(1): 1191-1195, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36314944

RESUMEN

OBJECTIVE: Various hematologic side effects of the Coronavirus Disease 2019 (COVID-19) vaccination has been reported, and most of them are thought to be related to autoimmune pathways. To the best of our knowledge, only few cases of post-COVID-19 vaccination aplastic anemia (AA) have been reported and there is no reported Korean case of COVID-19 vaccine-induced AA yet. We present a case of severe immune-mediated AA that developed after the administration of a messenger ribonucleic acid (mRNA) gene-based spike protein vaccine against COVID-19, which responded well to immunosuppressive therapy, and discuss the probable pathogenesis of AA and the implication of vaccination along with a comparison of previous cases reported. METHODS: A 53-year-old Korean man developed sudden pancytopenia three months after COVID-19 vaccination. To evaluate the cause of pancytopenia, a bone marrow study was performed. RESULTS: A diagnosis of AA was made through the bone marrow study and he received triple immunosuppressive therapy (IST). After triple IST for five months, his blood cell count was improved and maintained without transfusion and his follow-up bone marrow examination showed improved cellularity. CONCLUSION: COVID-19 vaccine might be associated with the development of immune-mediated AA. Prompt hematologic evaluation should be performed when there are symptoms or signs suggestive of cytopenia after COVID-19 vaccination. Although the clinical outcome of post-vaccination AA varies, a good prognosis can be possible for patients with COVID-19 vaccination-induced AA.


Asunto(s)
Anemia Aplásica , Vacunas contra la COVID-19 , COVID-19 , Pancitopenia , Humanos , Masculino , Persona de Mediana Edad , Anemia Aplásica/tratamiento farmacológico , COVID-19/prevención & control , Vacunas contra la COVID-19/efectos adversos , Terapia de Inmunosupresión/efectos adversos , Inmunosupresores/efectos adversos , Pancitopenia/inducido químicamente , ARN Mensajero , Vacunación/efectos adversos
6.
Clin Appl Thromb Hemost ; 28: 10760296221127276, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36172745

RESUMEN

Background: We investigated the importance of lupus anticoagulant (LA) in patients with SARS-CoV-2. Methods: Medical records of 41 SARS-CoV-2 infected patients were reviewed. Patients were classified into two groups according to the frequency of positive LA test results: "LA (-)" and "LA (+) ≥1" (LA positive at least once). Statistical analysis was performed to determine the association between LA presence and change in LA test results and disease course according to both hospital days (HD) and days after diagnosis (DD). Results: The prevalence of LA was 51.2%. Averagely, the first change in LA test result occurred during DD 12-13 and between HD 9-10. The second change occurred on DD 15-16 and HD 13-14. The presence of LA was associated with severe disease (P = .004) but was not associated with thrombotic complications or mortality. The change of results from negative to positive or vice versa or the frequency of the changes was not associated with disease severity, thrombotic complications, or mortality. Conclusions: LA positivity can be regarded as one of the findings suggesting more serious SARS-CoV-2 infection.


Asunto(s)
Síndrome Antifosfolípido , COVID-19 , Trombosis , Síndrome Antifosfolípido/complicaciones , COVID-19/complicaciones , Humanos , Inhibidor de Coagulación del Lupus , SARS-CoV-2 , Trombosis/complicaciones
7.
Anal Chem ; 94(28): 10127-10134, 2022 07 19.
Artículo en Inglés | MEDLINE | ID: mdl-35802862

RESUMEN

To achieve the measurement reliability of amino acids used as diagnostic markers in clinical fields, establishing a reference measurement system is required, in which certified reference materials (CRMs) are an essential step in the hierarchy of measurement traceability. This study describes the development of dried blood spot (DBS) CRMs for amino acid analysis with complete measurement traceability to the International System of Units (SI). Six essential amino acids─proline, valine, isoleucine, leucine, phenylalanine, and tyrosine─were analyzed using isotope-dilution liquid chromatography-mass spectrometry (ID-MS). For minimizing measurement bias and uncertainty overestimation, whole spots with 50 µL of whole blood were adopted in the certification. The between-spot homogeneities by whole spot sampling were lower than 2.1%. The relative expanded uncertainties of the six amino acids in the developed DBS CRMs were lower than 5.7% at 95% confidence. The certified values are traceable to SI through both gravimetric preparation and the primary method in certification, ID-MS. Comparison among DBS testing laboratories revealed discrepancies between the whole spot and disc sampling methods. The actual sampling volume was accurately estimated by weighing, which revealed the possibility of underestimation in routine DBS testing. The candidate CRMs can support the standardization of DBS testing for amino acids through the qualification and validation of many kinds of measurement procedures to compensate the measurement bias caused by matrix-specific sampling error.


Asunto(s)
Aminoácidos , Pruebas con Sangre Seca , Aminoácidos/análisis , Certificación , Cromatografía Liquida/métodos , Estándares de Referencia , Reproducibilidad de los Resultados
8.
J Clin Lab Anal ; 36(7): e24521, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35622611

RESUMEN

BACKGROUND: The standardization of measurement aims to achieve comparability of results regardless of the analytical methods and the laboratory where analyses are carried out. In this paper, a comparison of results from several immunoassay-based insulin analysis kits is described, and the steps necessary to improve comparability are discussed. METHODS: Four manual enzyme-linked immunosorbent assay (ELISA) kits produced by Mercodia, Alpco, Epitope Diagnostics, and Abcam, and three automated chemiluminescent (CLIA) insulin assay kits (Siemens Centaur XP, Unicel Dxl800, Cobas e801) were compared by analyzing human serum samples and certified reference materials for human insulin. RESULTS: The seven evaluated assay kits showed substantial discrepancies in the results, with relative standard deviation ranges between 1.7% and 23.2%. We find that the traceability chains and the unit conversion factors are not yet harmonized, and current reference materials for insulin are not applicable for immunoassay-based method validation due to the use of different matrices. CONCLUSIONS: The findings suggest the need to fine tune insulin analysis methods, measurement traceability, and any conversion factor used in post-analysis steps in accordance with the necessity for standardization.


Asunto(s)
Pruebas Inmunológicas , Insulina , Ensayo de Inmunoadsorción Enzimática/métodos , Humanos , Inmunoensayo/métodos , Estándares de Referencia
10.
Ann Lab Med ; 41(4): 366-371, 2021 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-33536354

RESUMEN

BACKGROUND: Total cholesterol concentration measurement is important in the diagnosis of dyslipidemia and evaluation of cardiovascular disease risk factors. Measurement reliability for obtaining an accurate total cholesterol concentration requires procedure standardization. We evaluated the standardization status for total cholesterol concentration measurement through Korean external quality assessment (EQA) data analysis. METHODS: This study involved 1,670 laboratories that participated in the EQA of total cholesterol concentration measurements in 2019 for 32 products from different manufacturers. The target concentrations of three quality control (QC) materials (samples A, B, and C) were measured using the reference method and compared with EQA data. The performance criteria for total cholesterol concentration measurement were based on the National Cholesterol Education Program guidelines, with ±3% inaccuracy. RESULTS: The target values and inaccuracies of the QC material based on the reference method measurements were 254.65±7.64, 108.30±3.25, and 256.29±7.69 mg/dL (6.59±0.20, 2.80±0.08, and 6.63±0.20 mmol/L) for samples A, B, and C, respectively. The performance criteria were not met in 42.7% laboratories for sample A, 68.4% of laboratories for sample B, and 38.0% laboratories for sample C. CONCLUSIONS: Despite significant efforts to accurately measure total cholesterol concentrations, further actions are needed for measurement standardization. Manufacturers reporting values that differ from target values should check calibrator traceability; additional efforts to accurately measure total cholesterol concentrations are required for laboratories that use products from these manufacturers.


Asunto(s)
Colesterol/análisis , Humanos , Laboratorios , Estándares de Referencia , Reproducibilidad de los Resultados , República de Corea
13.
Arch Virol ; 163(4): 969-976, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29327232

RESUMEN

Human papillomavirus (HPV) is a major cause of cervical neoplasia development. HPV screening is very important because early treatment can prevent cervical cancer. Omniplex-HPV is a polymerase chain reaction followed by Luminex xMAP bead microarray technology that is designed for detecting 40 HPV genotypes. The aim of this study is to evaluate the analytical and clinical performance of the Omniplex-HPV in comparison with that of the commercially available RFMP (restriction fragment mass polymorphism) HPV PapilloTyper. A total of 2,808 cervical swab specimens were obtained. Of these, only 1799 specimens had a cytology result. A type-specific direct sequencing test was performed using the reference method in case of discrepancies between the two test results. The overall percent agreement (OPA) between Omniplex-HPV and RFMP HPV PapilloTyper was 97.9% (κ=0.84; 95% CI: 0.81-0.88). The positive percent agreement (PPA) and the negative percent agreement (NPA) were 98.0% and 96.2%, respectively. The Omniplex-HPV and RFMP HPV PapilloTyper showed comparable sensitivities (90.2% and 91.9%, respectively) and specificities (91.3% each), while the Omniplex-HPV produced more accurate results and required less turnaround time and labor. The agreement between these two methods was excellent for HPV genotyping (P>0.05; McNemar's test), and clinical sensitivity, specificity, and odds ratio of the two assays were comparable to the result of cytology tests in identifying high risk HPV. In conclusion, Omniplex-HPV and RFMP HPV PapilloTyper were highly comparable with regard to detection and genotyping analysis of HPV.


Asunto(s)
ADN Viral/genética , Papillomaviridae/clasificación , Infecciones por Papillomavirus/diagnóstico , Reacción en Cadena de la Polimerasa/métodos , Polimorfismo de Longitud del Fragmento de Restricción , Displasia del Cuello del Útero/diagnóstico , Adulto , Cuello del Útero/patología , Cuello del Útero/virología , Femenino , Genotipo , Histocitoquímica/métodos , Humanos , Tamizaje Masivo , Persona de Mediana Edad , Papillomaviridae/genética , Papillomaviridae/aislamiento & purificación , Infecciones por Papillomavirus/patología , Infecciones por Papillomavirus/virología , Juego de Reactivos para Diagnóstico/normas , Sensibilidad y Especificidad , Displasia del Cuello del Útero/patología , Displasia del Cuello del Útero/virología
15.
Ann Lab Med ; 37(3): 213-222, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28224767

RESUMEN

BACKGROUND: Medical laboratories play a central role in health care. Many laboratories are taking a more focused and stringent approach to quality system management. In Korea, laboratory standardization efforts undertaken by the Korean Laboratory Accreditation Program (KLAP) and the Korean External Quality Assessment Scheme (KEQAS) may have facilitated an improvement in laboratory performance, but there are no fundamental studies demonstrating that laboratory standardization is effective. We analyzed the results of the KEQAS to identify significant differences between laboratories with or without KLAP and to determine the impact of laboratory standardization on the accuracy of diagnostic tests. METHODS: We analyzed KEQAS participant data on clinical chemistry tests such as albumin, ALT, AST, and glucose from 2010 to 2013. As a statistical parameter to assess performance bias between laboratories, we compared 4-yr variance index score (VIS) between the two groups with or without KLAP. RESULTS: Compared with the group without KLAP, the group with KLAP exhibited significantly lower geometric means of 4-yr VIS for all clinical chemistry tests (P<0.0001); this difference justified a high level of confidence in standardized services provided by accredited laboratories. Confidence intervals for the mean of each test in the two groups (accredited and non-accredited) did not overlap, suggesting that the means of the groups are significantly different. CONCLUSIONS: These results confirmed that practice standardization is strongly associated with the accuracy of test results. Our study emphasizes the necessity of establishing a system for standardization of diagnostic testing.


Asunto(s)
Pruebas Diagnósticas de Rutina/normas , Laboratorios de Hospital/normas , Acreditación , Alanina Transaminasa/sangre , Aspartato Aminotransferasas/sangre , Pruebas de Química Clínica , Control de Calidad , República de Corea , Albúmina Sérica/análisis
16.
Ann Lab Med ; 32(6): 438-41, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23130345

RESUMEN

We report a case of subcutaneous infection in a 55-yr-old Korean diabetic patient who presented with a cystic mass of the ankle. Black fungal colonies were observed after culturing on blood and Sabouraud dextrose agar. On microscopic observation, septated ellipsoidal or cylindrical conidia accumulating on an annellide were visualized after staining with lactophenol cotton blue. The organism was identified as Exophiala salmonis by sequencing of the ribosomal DNA internal transcribed spacer region. Phaeohyphomycosis is a heterogeneous group of mycotic infections caused by dematiaceous fungi and is commonly associated with immunocompromised patients. The most common clinical manifestations of subcutaneous lesions are abscesses or cystic masses. To the best of our knowledge, this is the first reported case in Korea of subcutaneous phaeohyphomycosis caused by E. salmonis that was confirmed by molecular analysis and identification of morphological characteristics. This case suggests that E. salmonis infections are no longer restricted to fish.


Asunto(s)
Exophiala/aislamiento & purificación , Feohifomicosis/diagnóstico , ADN Espaciador Ribosómico/genética , Bases de Datos Genéticas , Diabetes Mellitus Tipo 2/patología , Exophiala/genética , Humanos , Masculino , Persona de Mediana Edad , Feohifomicosis/microbiología , Análisis de Secuencia de ADN
17.
Ann Clin Lab Sci ; 42(4): 424-8, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23090741

RESUMEN

Systemic primary carnitine deficiency (CDSP) is a rare autosomal recessive disorder that presents episodic periods of hypoketotic hypoglycemia. The main symptoms of CDSP are skeletal and cardiac myopathy. CDSP is caused by a defect in plasma membrane uptake of carnitine, ultimately caused by the SLC22A5 gene. We report the case of a Korean patient with CDSP. He had an abnormal free carnitine level of 5.56 µmol/L (reference range, RR 10.4~87.1 µmol/L) and a palmitoylcarnitine level of 0.27 µmol/L (RR 0.5~9.7 µmol/L) in a newborn screening test. The patient showed an ammonia level of 129.4 ug/dL (RR, 25~65 ug/dL), a lactate level of 4.5 mmol/L (RR, 0.5-2.2 mmol/L), and a free carnitine level of 10.3 µmol/L (RR, 36-74 µmol/L) in blood. After PCR-sequencing analysis of the SLC22A5 gene, the patient was found to be a compound heterozygote for c.506G>A (p.R169Q) and c.1400C>G (p.S467C) mutations. These missense mutations are reported previously. The patient was started on L-carnitine supplement after CDSP diagnosis. The patient was treated with L-carnitine to reach a normal free carnitine level and has remained asymptomatic up to the current age of 21 months. The plasma free carnitine level normalized to 66.6 µmol/L at 4 weeks after treatment. To the best of our knowledge, this is the first report of a CDSP patient confirmed by molecular genetic investigation.


Asunto(s)
Cardiomiopatías/genética , Hiperamonemia/genética , Enfermedades Musculares/genética , Mutación Missense/genética , Proteínas de Transporte de Catión Orgánico/genética , Amoníaco/sangre , Secuencia de Bases , Cardiomiopatías/sangre , Cardiomiopatías/tratamiento farmacológico , Carnitina/sangre , Carnitina/deficiencia , Carnitina/genética , Carnitina/uso terapéutico , Humanos , Hiperamonemia/sangre , Hiperamonemia/tratamiento farmacológico , Recién Nacido , Ácido Láctico/sangre , Masculino , Datos de Secuencia Molecular , Enfermedades Musculares/sangre , Enfermedades Musculares/tratamiento farmacológico , Reacción en Cadena de la Polimerasa , República de Corea , Análisis de Secuencia de ADN , Miembro 5 de la Familia 22 de Transportadores de Solutos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...