Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Chem Res Toxicol ; 36(1): 94-103, 2023 01 16.
Artículo en Inglés | MEDLINE | ID: mdl-36602460

RESUMEN

This study used standard linear smoking machines and puffing protocols to generate data on carbonyl yields in mainstream smoke from 11 unfiltered sheet-wrapped cigars (SWC), seven leaf-wrapped cigars (LWC), and two Kentucky reference cigarettes (3R4F, 1R6F). Carbonyl yields in cigar and cigarette products were determined using three different smoking regimens: International Organization for Standardization (ISO), Canadian Intense (CI), and Cooperation Centre for Scientific Research Relative to Tobacco (CORESTA) Recommended Method (CRM) No. 64 (CRM64, Routine Analytical Cigar-Smoking Machine─Specifications, Definitions and Standard Conditions). Mainstream tobacco smoke was collected using a smoking machine fitted with an impinger containing 2,4-dinitrophenylhydrazine (DNPH) and carbonyl compounds quantified using liquid chromatography with an ultraviolet detector. Commercial SWC and LWC generated comparable formaldehyde yields (SWC, 9.4-28 µg/cigar [ISO], 8.2-43 µg/cigar [CI], 8.6-13 µg/cigar [CRM64]; LWC, 11-13 µg/cigar [ISO], 11-22 µg/cigar [CI], 16-21 µg/cigar [CRM64]) and acrolein yields; however, LWC generated higher acetaldehyde yields compared to SWC, using CI and CRM64 regimens. Reference cigarettes using standard puffing regimens generated carbonyl yields within reported ranges and 5-10% RSDs, whereas the CRM64 regimen generated lower carbonyl yields and 12-14% RSDs. Reference cigarettes generated higher formaldehyde yields using cigarette smoking regimens (21-28 µg/cigarette under ISO, 76-96 µg/cigarette under CI) but comparable formaldehyde yields under CRM64 (12-14 µg/cigarette). In addition, this study evaluated physical parameters (e.g., tobacco weight, length, diameter, circumference, tobacco rod density) that show the correlation between tobacco weight, tobacco rod density, and acetaldehyde yields under the three smoking regimens. Carbonyl yields in the mainstream smoke of cigar products using the three smoking regimens were highly variable; however, the CI smoking regimen may provide meaningful analytical information regarding cigar smoke constituents, with lower likelihood of self-extinguishment due to the short puffing intervals.


Asunto(s)
Fumar Cigarrillos , Productos de Tabaco , Canadá , Productos de Tabaco/análisis , Nicotiana/química , Formaldehído , Acetaldehído
2.
J Pharm Sci ; 111(6): 1700-1708, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34861248

RESUMEN

Portioned moist snuff and snus, two subcategories of smokeless tobacco products (STP) were dissolution tested as a quality control test. A USP Apparatus 4 was employed to develop and validate the method. The method was assessed based on time to reach nicotine dissolution plateau, percentage difference between two profiles at each time point, relative standard deviation (RSD), and f1 (similarity) and f2 (dissimilarity) values. Based on these criteria, 200 ml volume and 8 ml/min flow were found be discriminatory. The amount of nicotine dissolved from the nine products varied widely (2.0-3.4, 2.1-4.1, 3.3-4.6, 5.5-6.6, 6.9-9.1, 11.5-14.2, 12.5-14.6, 14.0-15.5, and 15.5-19.6 mg/pouch at 60 min). RSDs of the dissolution ranges were more than 20% at earlier time points and less than 20% at later timepoints. The developed method produced distinct profiles for all the tested products, which was further confirmed by f1>15 and f2<50 values. In conclusion, the developed method was discriminatory and can be employed as a quality control test and to differentiate among moist snuff and snus products.


Asunto(s)
Tabaco sin Humo , Nicotina , Solubilidad
3.
Forensic Chem ; 212020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34820592

RESUMEN

Canine training aids based on vapor capture-and-release into a flexible polymer, polydimethylsiloxane (PDMS), have been used for in canine detection of explosives that have volatile or semi-volatile odorants. To enhance the rate of odor capture for less volatile targets, two temperatures are used for aid preparation. By using an elevated temperature for the target explosive, the amount of vapor is enhanced, increasing the production of the characteristic odor profile. The polymeric adsorbent is maintained at a cool temperature, favoring vapor capture. The success of this two-temperature approach is demonstrated for training aids targeting the low volatility explosive TNT using SPME (solid-phase microextraction) headspace analysis. In addition, the effect of using two temperatures on preparing training aids based on TNT and its more volatile impurities 2,4-DNT and 2,6-DNT are evaluated in canine trials. A thermal pretreatment to minimize the non-target odors in the PDMS polymer is presented.

4.
Nicotine Tob Res ; 19(7): 865-870, 2017 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-28339569

RESUMEN

INTRODUCTION: Many carbonyls are produced from the combustion of tobacco products and many of these carbonyls are harmful or potentially harmful constituents of mainstream cigarette smoke. One carbonyl of particular interest is acrolein, which is formed from the incomplete combustion of organic matter and the most significant contributor to non-cancer respiratory effects from cigarette smoke. Sheet-wrapped cigars, also known as "little cigars," are a type of tobacco products that have not been extensively investigated in literature. METHODS: This study uses standard cigarette testing protocols to determine the acrolein yields from sheet-wrapped cigars. Sheet-wrapped cigar and cigarette products were tested by derivatizing the mainstream smoke with 2,4-dinitrophenylhydrazine (DNPH) solution and then quantifying the derivatives using conventional analytical systems. RESULTS: The results demonstrate that sheet-wrapped cigars can be tested for acrolein yields in mainstream smoke using the same methods used for the evaluation of cigarettes. The variability in the sheet-wrapped cigars and cigarettes under the International Organization for Standardization smoking regimen is statistically similar at the 95% confidence interval; however, increased variability is observed for sheet-wrapped cigar products under the Health Canada Intense (CI) smoking regimen. CONCLUSION: The amount of acrolein released by smoking sheet-wrapped cigars can be measured using standard smoking regimen currently used for cigarettes. The sheet-wrapped cigars were determined to yield similar quantity of acrolein from commercial cigarette products using two standard smoking regimens. IMPLICATIONS: This article reports on the measured quantity of acrolein from 15 commercial sheet-wrapped cigars using a validated standard smoking test method that derivatizes acrolein in the mainstream smoke with DNPH solution, and uses Liquid Chromatography/Ultra-Violet Detection (LC/UV) for separation and detection. These acrolein yields were similar to the levels found in the smoke from 35 commercial cigarette products measured in the same manner. Although sheet-wrapped cigar data were slightly more variable than those found for the cigarette data, this article reports that the production of acrolein is similar to cigarettes. The results demonstrate that sheet-wrapped cigars can be tested for acrolein yields in mainstream smoke using the same methods used for the evaluation of cigarettes.


Asunto(s)
Acroleína/análisis , Contaminantes Atmosféricos/análisis , Exposición a Riesgos Ambientales/análisis , Humo/análisis , Fumar , Productos de Tabaco/análisis , Canadá , Humanos
5.
J Chromatogr A ; 1455: 1-8, 2016 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-27286650

RESUMEN

A modified approach for characterization of the vapor-time profile of the headspace odors of explosives was developed using solid-phase microextraction (SPME) incorporating introduction of an externally-sampled internal standard (ESIS) followed by gas chromatography/mass spectrometry (GC/MS) analysis. With this new method, reproducibility of the measurements of 2-ethyl-1-hexanol and cyclohexanone were improved compared to previous work (Hoffman et al., 2009; Arthur and Pawliszyn, 1990) through the use of stable-isotope-labeled internal standards. Exposing the SPME fiber to the ESIS after sampling the target analyte proved to be advantageous, while still correcting for fiber variability and detector drift. For the analysis of high volatility compounds, incorporation of the ESIS using the SPME fiber in the retracted position minimized the subsequent competitive loss of the target analyte, allowing for much longer sampling times.


Asunto(s)
Cromatografía de Gases y Espectrometría de Masas , Gases/química , Odorantes/análisis , Ciclohexanonas/análisis , Ciclohexanonas/aislamiento & purificación , Ciclohexanonas/normas , Cromatografía de Gases y Espectrometría de Masas/normas , Hexanoles/análisis , Hexanoles/aislamiento & purificación , Hexanoles/normas , Marcaje Isotópico , Estándares de Referencia , Reproducibilidad de los Resultados , Microextracción en Fase Sólida
6.
Anal Bioanal Chem ; 403(2): 401-8, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22382857

RESUMEN

Triacetone triperoxide (TATP) is a high explosive synthesized from easily available reactants making it accessible for illicit uses. In this study, fast detection of TATP is achieved using a novel planar solid-phase microextraction (PSPME) as a preconcentration and sampling device for headspace analysis offering improved sensitivity and reduced sampling time over the conventional fiber-based solid-phase microextraction (SPME) when followed by ion mobility spectrometer (IMS) detection. Quantitation and comparison of the retention capabilities of PSPME as compared to the commercially available SPME were determined using TATP standards and analyzed using gas chromatography-mass spectrometry for SPME analysis and a commercial IMS with no instrumental modification for PSPME. Static and dynamic headspace extractions were used and compared for PSPME extractions, in which low milligram quantities of TATP were detected within 30 s of static mode sampling and less than 5 s in the dynamic mode sampling for PSPME-IMS.


Asunto(s)
Sustancias Explosivas/análisis , Sustancias Explosivas/aislamiento & purificación , Compuestos Heterocíclicos con 1 Anillo/análisis , Compuestos Heterocíclicos con 1 Anillo/aislamiento & purificación , Peróxidos/análisis , Peróxidos/aislamiento & purificación , Microextracción en Fase Sólida/métodos , Espectrometría de Masas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...