Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Anal Biochem ; 396(2): 325-7, 2010 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-19819218

RESUMEN

A liquid chromatographic method was developed to determine the modification degree of PEGylated proteins. This method effectively separated free polyethylene glycol (PEG) from other species in conjugation mixtures on a C4 reversed-phase column using water-acetonitrile gradient elution. Then the concentrations of free PEG were determined according to the integrated area under the curve of its evaporative light scattering detector (ELSD) signal, which was normalized by the PEG standard with similar molecular weights. The actual numbers of PEG attached to proteins, not those of lysines modified, were calculated. This method was performed with PEGylated arginase mixtures as an example and showed clear advantages over 2,4,6-trinitrobenzenesulfonic acid (TNBS) assays.


Asunto(s)
Arginasa/análisis , Cromatografía Líquida de Alta Presión/métodos , Polietilenglicoles/química , Arginasa/química , Proteínas Recombinantes/análisis , Proteínas Recombinantes/química , Ácido Trinitrobencenosulfónico/química
2.
Artículo en Inglés | MEDLINE | ID: mdl-19526439

RESUMEN

A solid phase conjugation process was developed for attachment of polyethylene glycol to hemoglobin molecule. Bovine hemoglobin was loaded onto an ion exchange chromatography column and adsorbed by the solid medium. Succinimidyl carbonate mPEG was introduced in the mobile phase after the adsorption. Pegylation took place between the hemoglobin on the solid phase, and the pegylation reagent in the liquid phase. A further elution was carried out to separate the pegylated and the unpegylated protein. Analysis by HPSEC, SDS-PAGE, and MALLS demonstrated that the fractions eluted from the solid phase contained well-defined components. Pegylated hemoglobin with one PEG chain was obtained with the yield of 75%, in comparison to the yield of 30% in the liquid phase pegylation. The P(50) values of the mono-pegylated hemoglobin, prepared with SC-mPEG 5 kDa, 10 kDa and 20 kDa, were 19.97, 20.23 and 20.54 mmHg, which were much closer to the value of red blood cells than that of pegylated hemoglobin prepared with the conventional method.


Asunto(s)
Hemoglobinas/química , Polietilenglicoles/química , Adsorción , Animales , Bovinos , Cromatografía Líquida de Alta Presión , Cromatografía por Intercambio Iónico , Electroforesis en Gel de Poliacrilamida , Hemoglobinas/análisis , Hemoglobinas/aislamiento & purificación , Hemoglobinas/metabolismo , Indicadores y Reactivos/química , Rayos Láser , Peso Molecular , Dispersión de Radiación
3.
Bioorg Med Chem Lett ; 17(20): 5605-9, 2007 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-17822896

RESUMEN

A clear and powerful chromatographic approach to purify polyethylene glycol derivatives at a preparative scale was reported, which was based on the polystyrene-divinylbenzene beads with ethanol/water as eluants. The validity of this method was verified with the reaction mixture of mPEG-Glu and mPEG propionaldehyde diethylacetal (ALD-PEG) as the model. The target products were one-step achieved with the purity of >99% on the polymer resins column at gram scale. The method developed was free from such disadvantages as utility of toxic solvent and narrow application scope, which was combined with conventional approaches. The method developed provided an appealing and attractive alternative methods for purification of PEG derivatives at a preparative scale.


Asunto(s)
Polietilenglicoles/química , Polietilenglicoles/aislamiento & purificación , Poliestirenos/química , Estirenos/química , Cromatografía Líquida de Alta Presión , Estructura Molecular , Polietilenglicoles/síntesis química
4.
Bioorg Med Chem ; 15(16): 5396-405, 2007 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-17561403

RESUMEN

Although PEGylation is a potential approach to prolong the half-lives and reduce the dosing frequency of therapeutic proteins, conjugation behaviors of polymer have pivotal effects on the remaining bioactivities of the derivatives. In this study, the PEGylation strategy of recombinant human interleukin-1 receptor antagonist was investigated. The random conjugation of polyethylene glycol to amino groups on the protein resulted in a severe loss of activity and only retained 9.8% of the activity. In contrast, the PEGylation at the thiol groups had moderate effects on the bioactivity of protein and 40% of activity was conserved. The results suggested that the thiol-target PEGylation was more beneficial for IL-1ra.


Asunto(s)
Proteína Antagonista del Receptor de Interleucina 1/antagonistas & inhibidores , Polietilenglicoles/química , Línea Celular , Fenómenos Químicos , Química Física , Cromatografía Líquida de Alta Presión , Cristalografía por Rayos X , Ésteres/química , Humanos , Proteína Antagonista del Receptor de Interleucina 1/química , Proteína Antagonista del Receptor de Interleucina 1/genética , Proteína Antagonista del Receptor de Interleucina 1/metabolismo , Maleimidas/química , Modelos Moleculares , Estructura Molecular , Estructura Terciaria de Proteína , Proteínas Recombinantes/antagonistas & inhibidores , Proteínas Recombinantes/genética , Proteínas Recombinantes/metabolismo , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción
5.
Artículo en Inglés | MEDLINE | ID: mdl-15960074

RESUMEN

Conjugate of bovine hemoglobin (bHb) and human serum albumin (HSA) was prepared. The product was simply composed of 89.7% one-to-one Hb-HSA conjugate, 6.0% oligomer of Hb and HSA, 3.5% unconjugated HSA and 0.8% unconjugated Hb, with an average molecular weight of 157 kD. The physicochemical characteristics were determined. Effects of single replacement on blood pressure and long-term survival of rats with 30% and 60% acute blood loss were studied, in comparison with Ringer-lactate solution, stroma-free hemoglobin (SFHb), 5% HSA in Ringer-lactate, whole blood and no resuscitation fluid. Results showed that Hb-HSA conjugate maintained the mean arterial pressure of rats to initial level with no pressor effect. Long-term effects of the replacement fluids on 30% bleeding rats showed that, for the group infused with Hb-HSA conjugate, histology of five major organs, heart, kidney, liver, spleen and lung, were essentially normal, similar to that of whole blood, while obviously renal side-effects appeared in other groups. The efficacy of the conjugate was further demonstrated by the resuscitation of lethal hemorrhagic shock rats (60% acute blood loss) with 100% survival rate (followed for 14 days), the same result as whole blood. The Hb-HSA conjugate can thus be another candidate for blood substitute in emergency.


Asunto(s)
Sustitutos Sanguíneos/síntesis química , Hemoglobinas/uso terapéutico , Polímeros/uso terapéutico , Albúmina Sérica/uso terapéutico , Animales , Presión Sanguínea/efectos de los fármacos , Sustitutos Sanguíneos/uso terapéutico , Bovinos , Dimerización , Hemoglobinas/química , Hemorragia/tratamiento farmacológico , Humanos , Polímeros/síntesis química , Ratas , Ratas Sprague-Dawley , Albúmina Sérica/química , Choque Hemorrágico/tratamiento farmacológico , Tasa de Supervivencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...