Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
JACC Cardiovasc Interv ; 13(10): 1251-1261, 2020 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-32360260

RESUMEN

OBJECTIVES: The aim of this study was to assess the value of echocardiographic right ventricular (RV) and systolic pulmonary artery pressure (sPAP) assessment in predicting transcatheter tricuspid edge-to-edge valve repair (TTVR) outcome. BACKGROUND: RV dysfunction and pulmonary hypertension are associated with poor prognosis and are systematically sought during tricuspid regurgitation evaluation. The value of echocardiographic assessment in predicting TTVR outcome is unknown. METHODS: Data were taken from the TriValve (Transcatheter Tricuspid Valve Therapies) registry, which includes patients undergoing TTVR at 14 European and North American centers. The primary outcome was 1-year survival free from hospitalization for heart failure, and secondary outcomes were 1-year survival and absence of hospital admission for heart failure at 1 year. RESULTS: Overall, 249 patients underwent TTVR between June 2015 and 2018 (mean tricuspid annular plane systolic excursion [TAPSE] 15.8 ± 15.3 mm, mean sPAP 43.6 ± 16.0 mm Hg). Tricuspid regurgitation grade ≥3+ was found in 96.8% of patients at baseline and 29.4% at final follow-up; 95.6% were in New York Heart Association functional class III or IV initially, compared with 34.3% at follow-up (p < 0.05). Final New York Heart Association functional class did not differ among TAPSE and sPAP quartiles, even when both low TAPSE and high sPAP were present. Rates of 1-year survival and survival free from hospitalization for heart failure were 83.9% and 78.7%, respectively, without significant differences according to baseline echocardiographic RV characteristics (TAPSE, fractional area change, and end-diastolic area) and sPAP (p > 0.05 for all). CONCLUSIONS: TTVR provides clinical improvement, with 1-year survival free from hospital readmission >75% in patients with severe tricuspid regurgitation. Conventional echocardiographic parameters used to assess RV function and sPAP did not predict clinical outcome after TTVR.


Asunto(s)
Presión Arterial , Cateterismo Cardíaco , Ecocardiografía , Arteria Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/terapia , Función Ventricular Derecha , Presión Ventricular , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Progresión de la Enfermedad , Europa (Continente) , Femenino , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , América del Norte , Valor Predictivo de las Pruebas , Estudios Prospectivos , Arteria Pulmonar/fisiopatología , Recuperación de la Función , Sistema de Registros , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/complicaciones , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/fisiopatología
2.
JACC Cardiovasc Interv ; 12(15): 1451-1461, 2019 08 12.
Artículo en Inglés | MEDLINE | ID: mdl-31395215

RESUMEN

OBJECTIVES: The purpose of this study was to evaluate procedural and 1-year clinical and echocardiographic outcomes of patients treated with tricuspid edge-to-edge repair. BACKGROUND: Transcatheter edge-to-edge repair has been successfully performed in selected patients with symptomatic tricuspid regurgitation (TR) and high risk for surgery, but outcome data are sparse. METHODS: This analysis of the multicenter international TriValve (Transcatheter Tricuspid Valve Therapies) registry included 249 patients with severe TR treated with edge-to-edge repair in compassionate and/or off-label use. Clinical and echocardiographic outcomes were prospectively collected and retrospectively analyzed. RESULTS: In 249 patients (mean age 77 ± 9 years; European System for Cardiac Operative Risk Evaluation II score 6.4% [interquartile range: 3.9% to 13.9%]), a successful procedure with TR reduction to grade ≤2+ was achieved in 77% by placement of 2 ± 1 tricuspid clips. Concomitant treatment of severe TR and mitral regurgitation was performed in 52% of patients. At 1-year follow-up, significant and durable improvements in TR severity (TR ≤2+ in 72% of patients) and New York Heart Association functional class (≤II in 69% of patients) were observed. All-cause mortality was 20%, and the combined rate of mortality and unplanned hospitalization for heart failure was 35%. Predictors of procedural failure included effective regurgitant orifice area, tricuspid coaptation gap, tricuspid tenting area, and absence of central or anteroseptal TR jet location. Predictors of 1-year mortality were procedural failure, worsening kidney function, and absence of sinus rhythm. CONCLUSIONS: Transcatheter tricuspid edge-to-edge repair can achieve TR reduction at 1 year, resulting in significant clinical improvement. Predictors of procedural failure and 1-year mortality identified here may help select patients who will benefit most from this therapy.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Ensayos de Uso Compasivo , Europa (Continente) , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica , Humanos , Masculino , América del Norte , Recuperación de la Función , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/mortalidad , Insuficiencia de la Válvula Tricúspide/fisiopatología
3.
Eur Heart J ; 40(5): 441-451, 2019 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-30357365

RESUMEN

Aims: We sought to evaluate the outcomes of transcatheter mitral valve replacement (TMVR) for patients with degenerated bioprostheses [valve-in-valve (ViV)], failed annuloplasty rings [valve-in-ring (ViR)], and severe mitral annular calcification [valve-in-mitral annular calcification (ViMAC)]. Methods and results: From the TMVR multicentre registry, procedural and clinical outcomes of ViV, ViR, and ViMAC were compared according to Mitral Valve Academic Research Consortium (MVARC) criteria. A total of 521 patients with mean Society of Thoracic Surgeons score of 9.0 ± 7.0% underwent TMVR (322 patients with ViV, 141 with ViR, and 58 with ViMAC). Trans-septal access and the Sapien valves were used in 39.5% and 90.0%, respectively. Overall technical success was excellent at 87.1%. However, left ventricular outflow tract obstruction occurred more frequently after ViMAC compared with ViR and ViV (39.7% vs. 5.0% vs. 2.2%; P < 0.001), whereas second valve implantation was more frequent in ViR compared with ViMAC and ViV (12.1% vs. 5.2% vs. 2.5%; P < 0.001). Accordingly, technical success rate was higher after ViV compared with ViR and ViMAC (94.4% vs. 80.9% vs. 62.1%; P < 0.001). Compared with ViMAC and ViV groups, ViR group had more frequent post-procedural mitral regurgitation ≥moderate (18.4% vs. 13.8% vs. 5.6%; P < 0.001) and subsequent paravalvular leak closure (7.8% vs. 0.0% vs. 2.2%; P = 0.006). All-cause mortality was higher after ViMAC compared with ViR and ViV at 30 days (34.5% vs. 9.9% vs. 6.2%; log-rank P < 0.001) and 1 year (62.8% vs. 30.6% vs. 14.0%; log-rank P < 0.001). On multivariable analysis, patients with failed annuloplasty rings and severe MAC were at increased risk of mortality after TMVR [ViR vs. ViV, hazard ratio (HR) 1.99, 95% confidence interval (CI) 1.27-3.12; P = 0.003; ViMAC vs. ViV, HR 5.29, 95% CI 3.29-8.51; P < 0.001]. Conclusion: The TMVR provided excellent outcomes for patients with degenerated bioprostheses despite high surgical risk. However, ViR and ViMAC were associated with higher rates of adverse events and mid-term mortality compared with ViV.


Asunto(s)
Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Anuloplastia de la Válvula Mitral , Válvula Mitral/cirugía , Falla de Prótesis , Anciano , Anciano de 80 o más Años , Calcinosis/cirugía , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/patología , Anuloplastia de la Válvula Mitral/efectos adversos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/mortalidad , Diseño de Prótesis , Accidente Cerebrovascular/etiología , Resultado del Tratamiento
4.
J Am Coll Cardiol ; 70(22): 2752-2763, 2017 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-29191323

RESUMEN

BACKGROUND: Limited data exist about safety and efficacy of transcatheter aortic valve replacement (TAVR) in patients with pure native aortic regurgitation (AR). OBJECTIVES: This study sought to compare the outcomes of TAVR with early- and new-generation devices in symptomatic patients with pure native AR. METHODS: From the pure native AR TAVR multicenter registry, procedural and clinical outcomes were assessed according to VARC-2 criteria and compared between early- and new-generation devices. RESULTS: A total of 331 patients with a mean STS score of 6.7 ± 6.7 underwent TAVR. The early- and new-generation devices were used in 119 patients (36.0%) and 212 patients (64.0%), respectively. STS score tended to be lower in the new-generation device group (6.2 ± 6.7 vs. 7.6 ± 6.7; p = 0.08), but transfemoral access was more frequently used in the early-generation device group (87.4% vs. 60.8%; p < 0.001). Compared with the early-generation devices, the new-generation devices were associated with a significantly higher device success rate (81.1% vs. 61.3%; p < 0.001) due to lower rates of second valve implantation (12.7% vs. 24.4%; p = 0.007) and post-procedural AR ≥ moderate (4.2% vs. 18.8%; p < 0.001). There were no significant differences in major 30-day endpoints between the 2 groups. The cumulative rates of all-cause and cardiovascular death at 1-year follow-up were 24.1% and 15.6%, respectively. The 1-year all-cause mortality rate was significantly higher in the patients with post-procedural AR ≥ moderate compared with those with post-procedural AR ≤ mild (46.1% vs. 21.8%; log-rank p = 0.001). On multivariable analysis, post-procedural AR ≥ moderate was independently associated with 1-year all-cause mortality (hazard ratio: 2.85; 95% confidence interval: 1.52 to 5.35; p = 0.001). CONCLUSIONS: Compared with the early-generation devices, TAVR using the new-generation devices was associated with improved procedural outcomes in treating patients with pure native AR. In patients with pure native AR, significant post-procedural AR was independently associated with increased mortality.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Aórtica/cirugía , Arteria Femoral/cirugía , Prótesis Valvulares Cardíacas , Complicaciones Posoperatorias , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/cirugía , Cateterismo Periférico/métodos , Cateterismo Periférico/estadística & datos numéricos , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/normas , Humanos , Cooperación Internacional , Masculino , Mortalidad , Evaluación de Procesos y Resultados en Atención de Salud , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Diseño de Prótesis/tendencias , Mejoramiento de la Calidad , Sistema de Registros/estadística & datos numéricos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/estadística & datos numéricos
5.
JACC Cardiovasc Interv ; 10(19): 1982-1990, 2017 10 09.
Artículo en Inglés | MEDLINE | ID: mdl-28982563

RESUMEN

OBJECTIVES: This study sought to develop a large, international registry to evaluate the diffusion of these approaches and investigate patient characteristics and initial clinical results. BACKGROUND: Several transcatheter tricuspid valve therapies are emerging as therapeutic options for patients with severe symptomatic tricuspid regurgitation (TR), generally a high-risk surgical population. METHODS: The TriValve (Transcatheter Tricuspid Valve Therapies) registry included 106 high-risk patients (76 ± 9 years of age; 60.4% women; European System for Cardiac Operative Risk Evaluation II 7.6 ± 5.7%) from 11 cardiac centers, with severe TR. RESULTS: A total of 35% of the patients had prior left heart valve intervention (surgical in 29 of 106 and transcatheter in 8 of 106 patients). Right ventricular (RV) dysfunction (tricuspid annular plane systolic excursion <17 mm) was present in 56.3% of the patients; 95% of the patients were in New York Heart Association functional class III to IV. The etiology of TR was functional in 95.2%, and the mean tricuspid annulus was 45.4 ± 11 mm. In 76.9% of the patients, the main location of the regurgitant jet was central; pre-procedural systolic pulmonary artery pressure was 39.7 ± 13.8 mm Hg; and the inferior vena cava was severely dilated in most of the patients (27.4 ± 6.8 mm). Implanted devices included MitraClip (n = 58), Trialign (n = 17), TriCinch (n = 15), FORMA (n = 7), Cardioband (n = 5), and caval valve implantation (n = 3). One case had combined Trialign + MitraClip. Patients treated with the different techniques were similar in terms of European System for Cardiac Operative Risk Evaluation II and degree of RV dysfunction. In 68% of the cases the tricuspid intervention was performed as an isolated procedure. Procedural success was achieved in 62% of cases. At 30-day follow-up, all-cause mortality was 3.7%, with an overall incidence of major adverse cardiac and cerebrovascular events of 26%; 58% of the patients were New York Heart Association functional class I or II at 30 days. CONCLUSIONS: Patients currently undergoing transcatheter tricuspid valve therapy are mostly high risk, with a functional etiology and very severe central regurgitation, and do not have severely impaired RV function. Initial results suggest that transcatheter tricuspid valve therapy is feasible with different techniques, but clinical efficacy requires further investigation.


Asunto(s)
Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Toma de Decisiones Clínicas , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica , Humanos , Masculino , Selección de Paciente , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/mortalidad , Insuficiencia de la Válvula Tricúspide/fisiopatología , Función Ventricular Derecha
6.
J Am Coll Cardiol ; 70(9): 1121-1131, 2017 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-28838360

RESUMEN

BACKGROUND: Limited data exist regarding transcatheter mitral valve replacement (TMVR) for patients with failed mitral valve replacement and repair. OBJECTIVES: This study sought to evaluate the outcomes of TMVR in patients with failed mitral bioprosthetic valves (valve-in-valve [ViV]) and annuloplasty rings (valve-in-ring [ViR]). METHODS: From the TMVR multicenter registry, procedural and clinical outcomes of mitral ViV and ViR were compared according to Mitral Valve Academic Research Consortium criteria. RESULTS: A total of 248 patients with mean Society of Thoracic Surgeons score of 8.9 ± 6.8% underwent TMVR. Transseptal access and the balloon-expandable valve were used in 33.1% and 89.9%, respectively. Compared with 176 patients undergoing ViV, 72 patients undergoing ViR had lower left ventricular ejection fraction (45.6 ± 17.4% vs. 55.3 ± 11.1%; p < 0.001). Overall technical and device success rates were acceptable, at 92.3% and 85.5%, respectively. However, compared with the ViV group, the ViR group had lower technical success (83.3% vs. 96.0%; p = 0.001) due to more frequent second valve implantation (11.1% vs. 2.8%; p = 0.008), and lower device success (76.4% vs. 89.2%; p = 0.009) due to more frequent reintervention (16.7% vs. 7.4%; p = 0.03). Mean mitral valve gradients were similar between groups (6.4 ± 2.3 mm Hg vs. 5.8 ± 2.7 mm Hg; p = 0.17), whereas the ViR group had more frequent post-procedural mitral regurgitation moderate or higher (19.4% vs. 6.8%; p = 0.003). Furthermore, the ViR group had more frequent life-threatening bleeding (8.3% vs. 2.3%; p = 0.03), acute kidney injury (11.1% vs. 4.0%; p = 0.03), and subsequent lower procedural success (58.3% vs. 79.5%; p = 0.001). The 1-year all-cause mortality rate was significantly higher in the ViR group compared with the ViV group (28.7% vs. 12.6%; log-rank test, p = 0.01). On multivariable analysis, failed annuloplasty ring was independently associated with all-cause mortality (hazard ratio: 2.70; 95% confidence interval: 1.34 to 5.43; p = 0.005). CONCLUSIONS: The TMVR procedure provided acceptable outcomes in high-risk patients with degenerated bioprostheses or failed annuloplasty rings, but mitral ViR was associated with higher rates of procedural complications and mid-term mortality compared with mitral ViV.


Asunto(s)
Bioprótesis/efectos adversos , Cateterismo Cardíaco/métodos , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anuloplastia de la Válvula Mitral/efectos adversos , Válvula Mitral/cirugía , Anciano , Europa (Continente)/epidemiología , Femenino , Humanos , Masculino , América del Norte/epidemiología , Diseño de Prótesis , Falla de Prótesis , Reoperación , Estudios Retrospectivos , Tasa de Supervivencia/tendencias , Resultado del Tratamiento
7.
Circulation ; 135(19): 1802-1814, 2017 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-28336788

RESUMEN

BACKGROUND: Current surgical and medical treatment options for severe tricuspid regurgitation (TR) are limited, and additional interventional approaches are required. In the present observational study, the safety and feasibility of transcatheter repair of chronic severe TR with the MitraClip system were evaluated. In addition, the effects on clinical symptoms were assessed. METHODS: Patients with heart failure symptoms and severe TR on optimal medical treatment were treated with the MitraClip system. Safety, defined as periprocedural adverse events such as death, myocardial infarction, stroke, or cardiac tamponade, and feasibility, defined as successful implantation of 1 or more MitraClip devices and reduction of TR by at least 1 grade, were evaluated before discharge and after 30 days. In addition, functional outcome, defined as changes in New York Heart Assocation class and 6-minute walking distance, were assessed. RESULTS: We included 64 consecutive patients (mean age 76.6±10 years) deemed unsuitable for surgery who underwent MitraClip treatment for chronic, severe TR for compassionate use. Functional TR was present in 88%; in addition, 22 patients were also treated with the MitraClip system for mitral regurgitation as a combined procedure. The degree of TR was severe or massive in 88% of patients before the procedure. The MitraClip device was successfully implanted in the tricuspid valve in 97% of the cases. After the procedure, TR was reduced by at least 1 grade in 91% of the patients, thereof 4% that were reduced from massive to severe. In 13% of patients, TR remained severe after the procedure. Significant reductions in effective regurgitant orifice area (0.9±0.3cm2 versus 0.4±0.2cm2; P<0.001), vena contracta width (1.1±0.5 cm versus 0.6±0.3 cm; P=0.001), and regurgitant volume (57.2±12.8 mL/beat versus 30.8±6.9 mL/beat; P<0.001) were observed. No intraprocedural deaths, cardiac tamponade, emergency surgery, stroke, myocardial infarction, or major vascular complications occurred. Three (5%) in-hospital deaths occurred. New York Heart Association class was significantly improved (P<0.001), and 6-minute walking distance increased significantly (165.9±102.5 m versus 193.5±115.9 m; P=0.007). CONCLUSIONS: Transcatheter treatment of TR with the MitraClip system seems to be safe and feasible in this cohort of preselected patients. Initial efficacy analysis showed encouraging reduction of TR, which may potentially result in improved clinical outcomes.


Asunto(s)
Cateterismo Cardíaco/métodos , Índice de Severidad de la Enfermedad , Instrumentos Quirúrgicos , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/terapia , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Ecocardiografía Transesofágica/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Instrumentos Quirúrgicos/estadística & datos numéricos , Resultado del Tratamiento
8.
EuroIntervention ; 12(15): e1817-e1824, 2017 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-28117278

RESUMEN

AIMS: The aim of this study was to determine the impact of tricuspid regurgitation (TR) on mortality after edge-to-edge percutaneous mitral valve repair (PMVR), and also to analyse whether there is a difference in outcome between patients with improvement of TR after PMVR compared to patients without. METHODS AND RESULTS: Out of 197 consecutive patients who underwent PMVR, 139 patients with available follow-up (mean 428±386 days) were included in the study. Concomitant moderate/severe TR was present in 58.3% of patients. Kaplan-Meier analysis showed significantly reduced overall survival for patients with moderate/severe TR, compared to patients with none/mild TR (p=0.003). Cox multivariate regression analysis revealed severe TR at baseline as the strongest independent predictor of mortality (HR 4.367, p=0.003). An improvement of the baseline moderate/severe TR was observed in 45.5% of patients at 30-day follow-up. Patients with no improvement of TR after PMVR had a higher midterm mortality compared to patients in whom TR improved (40.5% versus 11.4%, p=0.005). CONCLUSIONS: More than half of patients undergoing PMVR have concomitant moderate/severe TR, which is associated with a worse outcome. Among predictors of mortality after edge-to-edge PMVR, severe TR at baseline is the most important. Patients with no improvement of TR at 30 days after PMVR have a significantly higher mortality at follow-up.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Anciano , Anciano de 80 o más Años , Procedimientos Quirúrgicos Cardíacos/métodos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
9.
Ann Thorac Surg ; 101(3): 881-8; Dissicussion 888, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26603025

RESUMEN

BACKGROUND: Concerns still exist regarding long-term results and freedom from valve-related adverse events in transcatheter aortic valve implantation (TAVI). The aim of this single-center retrospective study was to assess intermediate-term (up to 5-year) clinical and hemodynamic outcomes in patients undergoing TAVI. METHODS: From 2007 through 2013, 338 consecutive patients underwent TAVI at our institution. Preoperative variables were defined according to the European System for Cardiac Operative Risk Evaluation (EuroSCORE) definitions, and outcomes were reported according to the Valve Academic Research Consortium (VARC)-2 definitions. Multivariate logistic regression analysis was performed to identify independent predictors of mortality at follow-up. RESULTS: transfemoral (TF) and transapical (TA) TAVI were performed in 233 (69%) and 105 (31%) patients, respectively. All-cause 30-day mortality was 4.4%, with no differences between TA and TF procedures. Thirty-day cardiovascular death, stroke, and myocardial infarction were not different between groups. The acute kidney injury (AKI) rate was higher in the TA group (30.5% versus 11.2%; p < 0.001). Access-related complications were more frequent in the TF group (36.1% versus 11.4%; p < 0.001). Mean follow-up was 22.3 ± 17.8 months (range, 1-74 months). Overall survival rates at 1, 3, and 5 years were 85.5% ± 2.1%, 69.9% ± 3.2%, and 61% ± 4.3%, respectively. Independent predictors of all-cause mortality at follow-up were previous myocardial infarction (odds ratio [OR], 2.7), any grade of paravalvular leak (PVL) (OR, 2.5), and AKI (OR, 3.1). Mean gradient and effective orifice area at follow-up were 10.7 ± 12.0 mm Hg and 1.1 ± 0.9 cm(2)/m(2), respectively. CONCLUSIONS: Our data show that TAVI has good early and intermediate-term clinical and hemodynamic outcomes in high-risk or inoperable patients with severe symptomatic aortic valve stenosis. PVL of any grade has a significant impact on survival.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Hemodinámica/fisiología , Complicaciones Posoperatorias/epidemiología , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Estudios de Seguimiento , Mortalidad Hospitalaria/tendencias , Humanos , Italia/epidemiología , Masculino , Estudios Retrospectivos , Tasa de Supervivencia/tendencias , Factores de Tiempo , Resultado del Tratamiento
10.
Catheter Cardiovasc Interv ; 81(2): 376-83, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22461314

RESUMEN

OBJECTIVES: We assessed the safety and effectiveness of a selective percutaneous revascularization strategy before TAVI in a single-center prospective registry. BACKGROUND: Management of Coronary Artery Disease (CAD) before Transcatheter Aortic Valve Implantation (TAVI) is not yet established. METHODS: Percutaneous Coronary Intervention (PCI) was scheduled in proximal-to-mid coronary segment lesions on major coronary branches. TAVI was performed by percutaneous trans-femoral, trans-subclavian or trans-apical approach, using either the self-expandable III generation CoreValve (Medtronic, Minneapolis, Minnesota USA) or the Edwards SAPIEN(™) /SAPIEN XT balloon-expandable prosthesis (Edwards Lifesciences Irvine, CA). Clinical and echocardiographic follow-up was collected at 30-day, 3,6,12-month and yearly thereafter. RESULTS: Out of 191 patients who underwent TAVI, 113 (59.2%) had CAD. Mean age was 80.5 ± 6.9 years (57.6% female), logistic EuroSCORE was 21.4% ± 13.4. Twenty-seven (14.1%) patients had previous percutaneous and 29 (15.2%) surgical revascularization. PCI was performed as scheduled before TAVI in 39 (20.4%) patients, without adverse events. Complete anatomical revascularization was obtained in 38 of 113 CAD patients (33.6%). After TAVI, 30-day mortality was 4.2%, and was comparable between CAD and no-CAD patients (P = ns), while 30-day myocardial infarction incidence was 2.6% and occurred only in the CAD group (4.4%, P = 0.06). Overall mortality at follow-up (12.9 ± 9.5 months) was 14.8%, without difference between groups (P = 0.88). At follow-up, five patients underwent coronary revascularization. CONCLUSIONS: In this study, the incidence of CAD is high in patients referred for TAVI. A selective, clinical based, coronary revascularization before TAVI seemed to be safe, and was associated with an outcome similar to those observed in no-CAD TAVI patients.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Cateterismo Cardíaco , Estenosis Coronaria/terapia , Implantación de Prótesis de Válvulas Cardíacas/métodos , Intervención Coronaria Percutánea , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Distribución de Chi-Cuadrado , Estenosis Coronaria/complicaciones , Estenosis Coronaria/mortalidad , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Italia , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Oportunidad Relativa , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
11.
Catheter Cardiovasc Interv ; 78(7): 996-1003, 2011 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-22114036

RESUMEN

OBJECTIVES: This study reports on mid-term safety and performance of valve-in-valve implantation as rescue strategy to overcome acute PPL after TAVI. BACKGROUND: Moderate to severe para-prosthetic leaks (PPL) after transcatheter aortic valve implantation (TAVI) have been described with both self-expandable and balloon-expandable device. METHODS: We analyzed data regarding patients who underwent valve-in-valve implantation, enrolled in the ongoing single-center prospective registry of TAVI, the Padova University REVALVing experience Registry. All procedures were performed by a totally percutaneous approach, using the self-expanding Medtronic CoreValve (Medtronic, Minneapolis, MN). RESULTS: Out of 87 patients who underwent TAVI, six received valve-in-valve implantation because of persisting severe PPL, due to prosthesis malposition. In all patients, the second device was successfully deployed, with a significant reduction in aortic regurgitation: PPL was no longer appreciable in two of six patients, and it decreased from severe to mild or trivial in four patients. Four patients developed atrio-ventricular block requiring pace-maker implantation. At follow-up (6-24 months) two patients died, whereas no prosthesis-related death occurred. Transprosthesis pressure gradient, effective orifice area, and aortic regurgitation did not change at serial echocardiograms throughout the follow-up. CONCLUSIONS: Valve-in-valve implantation using self-expandable bioprosthesis seems safe and highly effective to overcome severe PPL due to prosthesis malposition early after TAVI. Moreover, the implantation of two valves does not affect the performance of prosthesis at follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Bioprótesis , Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Falla de Prótesis , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Estudios de Factibilidad , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica , Humanos , Italia , Masculino , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Retratamiento , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...