Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Biofabrication ; 11(2): 025014, 2019 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-30786263

RESUMEN

Physicochemical and biological gradients are desirable features for hydrogels to enhance their relevance to biological environments for three-dimensional (3D) cell culture. Therefore, simple and efficient techniques to generate chemical, physical and biological gradients within hydrogels are highly desirable. This work demonstrates a technique to generate biomolecular and mechanical gradients in photocrosslinkable hydrogels by stacking and crosslinking prehydrogel solution in a layer by layer manner. Partial crosslinking of the hydrogel allows mixing of prehydrogel solution with the previous hydrogel layer, which makes a smooth gradient profile, rather than discrete layers. This technique enables the generation of concentration gradients of bovine serum albumin in both gelatin methacryloyl (GelMA) and poly(ethylene glycol) diacrylate hydrogels, as well as mechanical gradients across a hydrogel containing varying gel concentrations. Fluorescence microscopy, mechanical testing, and scanning electron microscopy show that the gradient profiles can be controlled by changing both the volume and concentration of each layer as well as intensity of UV exposure. GelMA hydrogel gradients with different Young's moduli were successfully used to culture human fibroblasts. The fibroblasts migrated along the gradient axis and showed different morphologies. In general, the proposed technique provides a rapid and simple approach to design and fabricate 3D hydrogel gradients for in vitro biological studies and potentially for in vivo tissue engineering applications.


Asunto(s)
Reactivos de Enlaces Cruzados/química , Hidrogeles/química , Luz , Fenómenos Mecánicos , Animales , Humanos , Metacrilatos/química , Ratones , Células 3T3 NIH , Polímeros/química , Albúmina Sérica Bovina/metabolismo , Porcinos , Rayos Ultravioleta
2.
J Pharm Biomed Anal ; 134: 36-42, 2017 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-27871055

RESUMEN

This paper introduces an integrated microfluidic chip as a promising tool to measure the concentration of bladder cancer cells (BCC) in urine samples. Silicon microchannels were used as trapping gates for both floated BCC and leukocytes which are found in the urine of patients. By the assistance of the gold electrodes patterned at the bottom of the micro gates, the capacitance of captured cancerous and blood cells were measured. Different membrane capacitance between BCC and leukocyte was the indicative signal for diagnosing the nature of captured cells in a urine like solution. The concentration range of the target that could be detected was about 10 BCCs per one chip. Such response has been achieved without applying any biochemical or florescent markers. Thus, it could be a simple and cheap approach to support cytological and immune-fluorescent assays. The limit of detection was approximately 1 cancerous cell/11 leukocytes in 1ml of the urine like solution. The entire measurement time was less than an hour. Consequently, this electrical microfluidic device promises significant potential in urinalysis.


Asunto(s)
Leucocitos/química , Leucocitos/metabolismo , Técnicas Analíticas Microfluídicas/métodos , Silicio/química , Neoplasias de la Vejiga Urinaria/sangre , Neoplasias de la Vejiga Urinaria/orina , Células Sanguíneas/química , Células Sanguíneas/metabolismo , Humanos , Dispositivos Laboratorio en un Chip , Urinálisis/métodos , Neoplasias de la Vejiga Urinaria/diagnóstico
3.
Mater Sci Eng C Mater Biol Appl ; 70(Pt 1): 681-688, 2017 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-27770942

RESUMEN

A highly sensitive impedimetric bio-chip based on vertically aligned multiwall carbon nanotubes (VAMWCNTs), was applied in direct interaction with lung cancer cells. Our tool provided both inducing and monitoring the bioelectrical changes in the cells initiated by electromagnetic (EM) wave stimulation. EM wave of 940MHz frequency with different intensities was used. Here, wave ablation might accumulate electrical charge on the tips of nanotubes penetrated into cell's membrane. The charge might induce ionic exchanges into the cell and cause alterations in electrical states of the membrane. Transmembrane electrostatic/dynamic states would be strongly affected due to such exchanges. Our novel modality was that, the cells' vitality changes caused by charge inductions were electrically detected with the same nanotubes in the architecture of electrodes for impedance measurement. The responses of the sensor were confirmed by electron and florescent microscopy images as well as biological assays. In summation, our method provided an effective biochip for enhancing and detecting external EM stimulation on the cells useful for future diagnostic and therapeutic applications, such as wave-guided drug-resistance breakage.


Asunto(s)
Electricidad , Fenómenos Electromagnéticos , Nanotubos de Carbono/química , Línea Celular , Línea Celular Tumoral , Supervivencia Celular , Espectroscopía Dieléctrica , Electrodos , Fluorescencia , Humanos , Nanotubos de Carbono/ultraestructura
4.
Anal Chim Acta ; 938: 72-81, 2016 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-27619088

RESUMEN

One of the most interested molecular research in the field of cancer detection is the mechanism of drug effect on cancer cells. Translating molecular evidence into electrochemical profiles would open new opportunities in cancer research. In this manner, applying nanostructures with anomalous physical and chemical properties as well as biocompatibility would be a suitable choice for the cell based electrochemical sensing. Silicon based nanostructure are the most interested nanomaterials used in electrochemical biosensors because of their compatibility with electronic fabrication process and well engineering in size and electrical properties. Here we apply silicon nanograss (SiNG) probing electrodes produced by reactive ion etching (RIE) on silicon wafer to electrochemically diagnose the effect of anticancer drugs on breast tumor cells. Paclitaxel (PTX) and mebendazole (MBZ) drugs have been used as polymerizing and depolymerizing agents of microtubules. PTX would perturb the anodic/cathodic responses of the cell-covered biosensor by binding phosphate groups to deformed proteins due to extracellular signal-regulated kinase (ERK(1/2)) pathway. MBZ induces accumulation of Cytochrome C in cytoplasm. Reduction of the mentioned agents in cytosol would change the ionic state of the cells monitored by silicon nanograss working electrodes (SiNGWEs). By extending the contacts with cancer cells, SiNGWEs can detect minor signal transduction and bio recognition events, resulting in precise biosensing. Effects of MBZ and PTX drugs, (with the concentrations of 2 nM and 0.1 nM, respectively) on electrochemical activity of MCF-7 cells are successfully recorded which are corroborated by confocal and flow cytometry assays.


Asunto(s)
Neoplasias de la Mama/tratamiento farmacológico , Electrodos , Mebendazol/farmacología , Nanotecnología , Paclitaxel/farmacología , Silicio/química , Tubulina (Proteína)/efectos de los fármacos , Neoplasias de la Mama/patología , Femenino , Humanos , Células MCF-7
5.
Small ; 12(7): 883-91, 2016 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-26727927

RESUMEN

An integrated nano-electromechanical chip (NELMEC) has been developed for the label-free distinguishing of both epithelial and mesenchymal circulating tumor cells (ECTCs and MCTCs, respectively) from white blood cells (WBCs). This nanoelectronic microfluidic chip fabricated by silicon micromachining can trap large single cells (>12 µm) at the opening of the analysis microchannel arrays. The nature of the captured cells is detected using silicon nanograss (SiNG) electrodes patterned at the entrance of the channels. There is an observable difference between the membrane capacitance of the ECTCs and MCTCs and that of WBCs (measured using SiNG electrodes), which is the key indication for our diagnosis. The NELMEC chip not only solves the problem of the size overlap between CTCs and WBCs but also detects MCTCs without the need for any markers or tagging processes, which has been an important problem in previously reported CTC detection systems. The great conductivity of the gold-coated SiNG nanocontacts as well as their safe penetration into the membrane of captured cells, facilitate a precise and direct signal extraction to distinguish the type of captured cell. The results achieved from epithelial (MCF-7) and mesenchymal (MDA-MB231) breast cancer cells circulated in unprocessed blood suggest the significant applications for these diagnostic abilities of NELMEC.


Asunto(s)
Separación Celular/métodos , Electrónica/métodos , Células Epiteliales/patología , Leucocitos/patología , Mesodermo/patología , Técnicas Analíticas Microfluídicas/métodos , Nanotecnología/métodos , Células Neoplásicas Circulantes/patología , Línea Celular Tumoral , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...