Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
2.
Zhonghua Yi Xue Za Zhi ; 88(39): 2792-4, 2008 Oct 28.
Artículo en Chino | MEDLINE | ID: mdl-19080459

RESUMEN

OBJECTIVE: To investigate the clinical effects of total knee arthroplasty in treatment of ankylosed knee caused by various reasons. METHODS: Four patients with 7 ankylosed knees, caused by ankylosing spondylitis in 1 case, septic arthritis with bony ankylosis in 1 case, and rheumatoid arthritis in 2 cases, underwent artificial knee replacement. Before the operation joint activity was 0 degrees , Knee Society score (KSS) was 42 (11 - 63), and the function score was 17. Follow-up was conducted for 5 - 27 months. RESULTS: Follow-up showed that the average joint activity was raised to 83 degrees (60 degrees - 110 degrees ), KSS score to 83 (64 - 91) points, and function score to 77 points. No infectious case was found. CONCLUSION: Total knee arthroplasty has a satisfactory effect in treatment of ankylosed knee. Computer assisted navigation system is helpful in femoro-tibial osteotomy and soft tissue balance. Individualized and directed rehabilitation is a pivotal factor.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Articulación de la Rodilla , Osteoartritis de la Rodilla/cirugía , Adulto , Anciano , Anquilosis/cirugía , Femenino , Estudios de Seguimiento , Humanos , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad
3.
Zhonghua Yi Xue Za Zhi ; 87(43): 3035-7, 2007 Nov 20.
Artículo en Chino | MEDLINE | ID: mdl-18261345

RESUMEN

OBJECTIVE: To compare the effects of Computer-assisted navigation (CAS) and conventional location technique in total knee arthroplasty (TKA). METHODS: Eight patients (11 knees) underwent CAS and 9 patients (11 knees) underwent conventional location technique for TKA. Follow-up was conducted for 5 - 12 months. The outcomes were compared. RESULTS: The mechanical axe error of the CAS group was (2.14 +/- 0.25) degrees, significantly less than that of the conventional group [(5.12 +/- 2.13) degrees, P = 0.005]. The soft tissue balance angle variable of the CAS group was (1.04 +/- 0.18) degrees, significantly less than that of the conventional group [(4.12 +/- 1.72) degrees, P = 0.005]. The soft tissue separation variable of the CAS group was (3.4 +/- 1.2) mm, significantly less than that of the conventional group [(6.1 +/- 2.4) mm, P = 0.005]. No fat embolism occurred in these 2 groups. The operating time of the CAS group was (82 +/- 18) min, significantly longer than that of the conventional group [(59 +/- 11) min, P = 0.005]. CONCLUSION: CAS causes more reliable artificial joint implantation and better soft-tissues balance, however, needs more operating time.


Asunto(s)
Anquilosis/cirugía , Artroplastia de Reemplazo de Rodilla/métodos , Neuronavegación/métodos , Adulto , Anciano , Anquilosis/diagnóstico , Femenino , Estudios de Seguimiento , Humanos , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...