Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Acad Radiol ; 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39112295

RESUMEN

RATIONALE AND OBJECTIVES: To validate the image quality of low-dose ultra-high-resolution (UHR) scanning mode of photon-counting detector CT (PCD-CT) for visceral artery computed tomography angiography (CTA). MATERIAL AND METHODS: We prospectively enrolled 57 patients each in the full dose (FD) and low-dose (LD) protocols, respectively, to undergo abdominal CT scans using the UHR mode on a PCD-CT system (NAEOTOM Alpha), between April 2023 and September 2023. Both the FD data and LD data were then reconstructed into two series of images: (a) 0.2 mm slice thickness, reconstruction kernel Bv48, quantum iterative reconstruction (QIR) 4; (b)1 mm slice thickness, Bv40, QIR 3. The signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) of seven arteries were objectively measured. The image noise, vessel sharpness, overall quality, and visibility of nine arteries were subjectively assessed by three radiologists. RESULTS: The SNRs and CNRs of 0.2 mm reconstruction set was inferior to that of 1 mm reconstruction set (p < 0.001 for all the arteries and noise), however, the image quality of 0.2 mm reconstruction set was higher than that of 1 mm reconstruction set in qualitative evaluation especially for tiny arteries in Volume-rendered (VR) image (p < 0.001). The SNRs and CNRs were not significantly higher for FD group than LD group on the same slice thickness except for SNRs of common hepatic artery, splenic artery and bilateral renal arteries in 0.2 mm reconstruction set. In the comparison on image quality between normal weight and overweight patients within the same reconstruction set, the results showed that low-dose scan did not significantly impact the image quality in overweight patients. The ratings of visibility of nine visceral arteries were not significantly different among FD and LD at the same thickness reconstruction set except for superior mesenteric artery (p = 0.002 and 0.007 for 0.2 mm and 1 mm reconstruction set in axial image; p = 0.002 and 0.007 for 0.2 mm and 1 mm reconstruction set in coronal image, respectively) and left gastric artery (p = 0.002 and p < 0.001 for 0.2 mm and 1 mm reconstruction set in VR image, respectively). CONCLUSION: The low-dose UHR scanning mode of PCD-CT has proven to be adequate for the clinical evaluation of visceral arteries. Utilizing a reconstruction with a slice thickness of 0.2 mm could enhance arterial depiction, particularly for small vessels.

2.
Insights Imaging ; 15(1): 186, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39090273

RESUMEN

OBJECTIVE: To evaluate whether and how the radiological journals present their policies on the use of large language models (LLMs), and identify the journal characteristic variables that are associated with the presence. METHODS: In this meta-research study, we screened Journals from the Radiology, Nuclear Medicine and Medical Imaging Category, 2022 Journal Citation Reports, excluding journals in non-English languages and relevant documents unavailable. We assessed their LLM use policies: (1) whether the policy is present; (2) whether the policy for the authors, the reviewers, and the editors is present; and (3) whether the policy asks the author to report the usage of LLMs, the name of LLMs, the section that used LLMs, the role of LLMs, the verification of LLMs, and the potential influence of LLMs. The association between the presence of policies and journal characteristic variables was evaluated. RESULTS: The LLM use policies were presented in 43.9% (83/189) of journals, and those for the authors, the reviewers, and the editor were presented in 43.4% (82/189), 29.6% (56/189) and 25.9% (49/189) of journals, respectively. Many journals mentioned the aspects of the usage (43.4%, 82/189), the name (34.9%, 66/189), the verification (33.3%, 63/189), and the role (31.7%, 60/189) of LLMs, while the potential influence of LLMs (4.2%, 8/189), and the section that used LLMs (1.6%, 3/189) were seldomly touched. The publisher is related to the presence of LLM use policies (p < 0.001). CONCLUSION: The presence of LLM use policies is suboptimal in radiological journals. A reporting guideline is encouraged to facilitate reporting quality and transparency. CRITICAL RELEVANCE STATEMENT: It may facilitate the quality and transparency of the use of LLMs in scientific writing if a shared complete reporting guideline is developed by stakeholders and then endorsed by journals. KEY POINTS: The policies on LLM use in radiological journals are unexplored. Some of the radiological journals presented policies on LLM use. A shared complete reporting guideline for LLM use is desired.

3.
Eur Radiol ; 2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-39048741

RESUMEN

OBJECTIVES: To evaluate the robustness of radiomics features among photon-counting detector CT (PCD-CT) and dual-energy CT (DECT) systems. METHODS: A texture phantom consisting of twenty-eight materials was scanned with one PCD-CT and four DECT systems (dual-source, rapid kV-switching, dual-layer, and sequential scanning) at three dose levels twice. Thirty sets of virtual monochromatic images at 70 keV were reconstructed. Regions of interest were delineated for each material with a rigid registration. Ninety-three radiomics were extracted per PyRadiomics. The test-retest repeatability between repeated scans was assessed by Bland-Altman analysis. The intra-system reproducibility between dose levels, and inter-system reproducibility within the same dose level, were evaluated by intraclass correlation coefficient (ICC) and concordance correlation coefficient (CCC). Inter-system variability among five scanners was assessed by coefficient of variation (CV) and quartile coefficient of dispersion (QCD). RESULTS: The test-retest repeatability analysis presented that 97.1% of features were repeatable between scan-rescans. The mean ± standard deviation ICC and CCC were 0.945 ± 0.079 and 0.945 ± 0.079 for intra-system reproducibility, respectively, and 86.0% and 85.7% of features were with ICC > 0.90 and CCC > 0.90, respectively, between different dose levels. The mean ± standard deviation ICC and CCC were 0.157 ± 0.174 and 0.157 ± 0.174 for inter-system reproducibility, respectively, and none of the features were with ICC > 0.90 or CCC > 0.90 within the same dose level. The inter-system variability suggested that 6.5% and 12.8% of features were with CV < 10% and QCD < 10%, respectively, among five CT systems. CONCLUSION: The radiomics features were non-reproducible with significant variability in values among different CT techniques. CLINICAL RELEVANCE STATEMENT: Radiomics features are non-reproducible with significant variability in values among photon-counting detector CT and dual-energy CT systems, necessitating careful attention to improve the cross-system generalizability of radiomic features before implementation of radiomics analysis in clinical routine. KEY POINTS: CT radiomics stability should be guaranteed before the implementation in the clinical routine. Radiomics robustness was on a low level among photon-counting detectors and dual-energy CT techniques. Limited inter-system robustness of radiomic features may impact the generalizability of models.

4.
Acta Radiol ; 65(9): 1133-1146, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39033390

RESUMEN

BACKGROUND: The best settings of deep learning image reconstruction (DLIR) algorithm for abdominal low-kiloelectron volt (keV) virtual monoenergetic imaging (VMI) have not been determined. PURPOSE: To determine the optimal settings of the DLIR algorithm for abdominal low-keV VMI. MATERIAL AND METHODS: The portal-venous phase computed tomography (CT) scans of 109 participants with 152 lesions were reconstructed into four image series: VMI at 50 keV using adaptive statistical iterative reconstruction (Asir-V) at 50% blending (AV-50); and VMI at 40 keV using AV-50 and DLIR at medium (DLIR-M) and high strength (DLIR-H). The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of nine anatomical sites were calculated. Noise power spectrum (NPS) using homogenous region of liver, and edge rise slope (ERS) at five edges were measured. Five radiologists rated image quality and diagnostic acceptability, and evaluated the lesion conspicuity. RESULTS: The SNR and CNR values, and noise and noise peak in NPS measurements, were significantly lower in DLIR images than AV-50 images in all anatomical sites (all P < 0.001). The ERS values were significantly higher in 40-keV images than 50-keV images at all edges (all P < 0.001). The differences of the peak and average spatial frequency among the four reconstruction algorithms were significant but relatively small. The 40-keV images were rated higher with DLIR-M than DLIR-H for diagnostic acceptance (P < 0.001) and lesion conspicuity (P = 0.010). CONCLUSION: DLIR provides lower noise, higher sharpness, and more natural texture to allow 40 keV to be a new standard for routine VMI reconstruction for the abdomen and DLIR-M gains higher diagnostic acceptance and lesion conspicuity rating than DLIR-H.


Asunto(s)
Aprendizaje Profundo , Interpretación de Imagen Radiográfica Asistida por Computador , Radiografía Abdominal , Imagen Radiográfica por Emisión de Doble Fotón , Relación Señal-Ruido , Tomografía Computarizada por Rayos X , Humanos , Femenino , Masculino , Tomografía Computarizada por Rayos X/métodos , Persona de Mediana Edad , Anciano , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Abdominal/métodos , Adulto , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Algoritmos , Anciano de 80 o más Años , Procesamiento de Imagen Asistido por Computador/métodos , Estudios Retrospectivos
5.
Chemosphere ; 362: 142667, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38906190

RESUMEN

This study presents the successful synthesis of Magnesium-aluminum layered double hydroxide composite phosphate-modified hydrothermal biochar for efficient removal of U(VI) from aqueous solutions. A novel synthesis approach involving phosphate thermal polymerization-hydrothermal method was employed, deviating from conventional pyrolysis methods, to produce hydrothermal biochar. The combination of solvent thermal polymerization technique with hydrothermal process facilitated efficient loading of layered double hydroxide (LDH) components onto the biochar surface, ensuring simplicity, low energy consumption and enhanced modifiability. Bamboo waste was utilized as the precursor for biochar, highlighting its superior green and sustainable characteristics. Additionally, this study elucidated the interactions between phosphate-modified hydrothermal biochar and LDH components with U(VI). Physicochemical analysis demonstrated that the composite biochar possessed a high surface area and abundant oxygen-containing functional groups. XPS and FTIR analyses confirmed the efficient adsorption of U(VI), attributed to chelation interactions between phosphate groups, magnesium hydroxyl groups, hydroxyl groups and U(VI), as well as the co-precipitation of U(VI) with multi-hydroxyl aluminum cations captured by LDH. The composite biochar reached adsorption equilibrium with U(VI) within 80 min and exhibited excellent fitting to the pseudo-second-order kinetic model and Langmuir model. Under conditions of pH = 4 and 298 K, it displayed significantly high maximum adsorption capacity of approximately 388.81 mg g⁻1, surpassing untreated biochar by 17-fold. The adsorption process was found to be endothermic and spontaneous and even after five consecutive adsorption-desorption cycles, the removal efficiency of U(VI) remained stable at 75.46%. These findings underscore the promising application prospects of Magnesium-aluminum layered double hydroxide composite phosphate-modified hydrothermal biochar in efficiently separating U(VI) from uranium-containing wastewater, emphasizing its environmental and economic value.


Asunto(s)
Carbón Orgánico , Hidróxidos , Magnesio , Fosfatos , Uranio , Carbón Orgánico/química , Adsorción , Uranio/química , Fosfatos/química , Magnesio/química , Hidróxidos/química , Aluminio/química , Cinética , Contaminantes Químicos del Agua/química , Contaminantes Químicos del Agua/análisis , Hidróxido de Aluminio/química
6.
BMC Med Imaging ; 24(1): 159, 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38926711

RESUMEN

BACKGROUND: To assess the improvement of image quality and diagnostic acceptance of thinner slice iodine maps enabled by deep learning image reconstruction (DLIR) in abdominal dual-energy CT (DECT). METHODS: This study prospectively included 104 participants with 136 lesions. Four series of iodine maps were generated based on portal-venous scans of contrast-enhanced abdominal DECT: 5-mm and 1.25-mm using adaptive statistical iterative reconstruction-V (Asir-V) with 50% blending (AV-50), and 1.25-mm using DLIR with medium (DLIR-M), and high strength (DLIR-H). The iodine concentrations (IC) and their standard deviations of nine anatomical sites were measured, and the corresponding coefficient of variations (CV) were calculated. Noise-power-spectrum (NPS) and edge-rise-slope (ERS) were measured. Five radiologists rated image quality in terms of image noise, contrast, sharpness, texture, and small structure visibility, and evaluated overall diagnostic acceptability of images and lesion conspicuity. RESULTS: The four reconstructions maintained the IC values unchanged in nine anatomical sites (all p > 0.999). Compared to 1.25-mm AV-50, 1.25-mm DLIR-M and DLIR-H significantly reduced CV values (all p < 0.001) and presented lower noise and noise peak (both p < 0.001). Compared to 5-mm AV-50, 1.25-mm images had higher ERS (all p < 0.001). The difference of the peak and average spatial frequency among the four reconstructions was relatively small but statistically significant (both p < 0.001). The 1.25-mm DLIR-M images were rated higher than the 5-mm and 1.25-mm AV-50 images for diagnostic acceptability and lesion conspicuity (all P < 0.001). CONCLUSIONS: DLIR may facilitate the thinner slice thickness iodine maps in abdominal DECT for improvement of image quality, diagnostic acceptability, and lesion conspicuity.


Asunto(s)
Medios de Contraste , Aprendizaje Profundo , Interpretación de Imagen Radiográfica Asistida por Computador , Radiografía Abdominal , Imagen Radiográfica por Emisión de Doble Fotón , Tomografía Computarizada por Rayos X , Humanos , Estudios Prospectivos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Tomografía Computarizada por Rayos X/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Abdominal/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Adulto , Yodo , Anciano de 80 o más Años
7.
Quant Imaging Med Surg ; 14(5): 3275-3288, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38720842

RESUMEN

Background: Anterior knee pain (AKP) is a common symptom of patellofemoral osteoarthritis (PFOA). There is limited prospective evidence supporting the relationships between patellofemoral maltracking parameters, AKP, and PFOA. Thus, this prospective cross-sectional study aimed to determine the association between quadriceps fat pad (QFP) edema and patellofemoral maltracking in patients with chronic AKP and to evaluate the feasibility and diagnostic performance of a PFOA assessment using fat fraction (FF) and T2* based on Q-Dixon. Methods: This was a cross-sectional study with prospective data collection. Patients with chronic AKP were recruited from an orthopedic outpatient magnetic resonance imaging (MRI) waiting room at Shanghai Tongren Hospital between November 1, 2022, and April, 30, 2023. Exclusion criteria included age of <18 years, knee trauma, major internal derangement, prior surgery/arthroscopy, pre-existing joint diseases, and contraindications to MRI. MRI was performed using a 3.0-T instrument, and patellofemoral maltracking parameters were measured. Patellofemoral feature-relevant items, including patellar cartilage defects, patellar bone marrow lesions (BMLs), patellar osteophytes, anterior femoral osteophytes, Hoffa synovitis, and synovitis-effusion, from the semi-quantitative MRI Osteoarthritis Knee Score (MOAKS) were measured. The Anterior Knee Pain Scale (AKPS) was used to assess pain and function. FF/T2* measurement differences between groups and their associations with maltracking metrics, osteoarthritis grading based on the Iwano grading system, MOAKS, and AKPS, were investigated. Based on Iwano grading, the participants were categorized as having no-PFOA (n=40), mild PFOA (n=40), and advanced PFOA (n=40). Chi-squared and one-way analysis of variance were used to assess potential differences between the groups. Spearman's correlation test was used to analyze the correlation between the morphological parameters, AKPS, Iwano grade, MOAKS, and MRI quantitative values. Receiver operating characteristic (ROC) curves assessed the area under the curve (AUC), sensitivity, and specificity of quantitative values for distinguishing PFOA from no-PFOA. Results: Among the 120 included patients, those in the mild (86.2±8.5) and advanced (83.9±9.5) PFOA groups had significantly lower AKPS scores than those in the no-PFOA group (88.8±7.3) (P=0.03). The mean FF and T2* values of the QFP were significantly higher in the no-PFOA group than those in the mild and advanced PFOA groups (P<0.001 for FF and P=0.02 for T2*). Quantitative data on the QFP and patellofemoral maltracking parameters showed no association. FF (r=-0.686, P<0.001) and T2* (r=-0.314, P=0.008) showed a negative correlation with the Iwano grade. The AUCs for PFOA diagnosis were 0.906 [95% confidence interval (CI), 0.853-0.960] (FF) and 0.744 (95% CI, 0.657-0.831) (T2*). Conclusions: QFP FF and T2* were not associated with patellofemoral maltracking parameters but with increased PFOA in patients with AKP, suggesting that QFP abnormalities play a role in PFOA. Therefore, a quantitative QFP assessment (FF and T2*) based on Q-Dixon technology could be a convenient and reliable new imaging biomarker for PFOA severity during clinical diagnosis, treatment, and follow-up.

8.
Artículo en Inglés | MEDLINE | ID: mdl-38656846

RESUMEN

Multilabel feature selection solves the dimension distress of high-dimensional multilabel data by selecting the optimal subset of features. Noisy and incomplete labels of raw multilabel data hinder the acquisition of label-guided information. In existing approaches, mapping the label space to a low-dimensional latent space by semantic decomposition to mitigate label noise is considered an effective strategy. However, the decomposed latent label space contains redundant label information, which misleads the capture of potential label relevance. To eliminate the effect of redundant information on the extraction of latent label correlations, a novel method named SLOFS via shared latent sublabel structure and simultaneous orthogonal basis clustering for multilabel feature selection is proposed. First, a latent orthogonal base structure shared (LOBSS) term is engineered to guide the construction of a redundancy-free latent sublabel space via the separated latent clustering center structure. The LOBSS term simultaneously retains latent sublabel information and latent clustering center structure. Moreover, the structure and relevance information of nonredundant latent sublabels are fully explored. The introduction of graph regularization ensures structural consistency in the data space and latent sublabels, thus helping the feature selection process. SLOFS employs a dynamic sublabel graph to obtain a high-quality sublabel space and uses regularization to constrain label correlations on dynamic sublabel projections. Finally, an effective convergence provable optimization scheme is proposed to solve the SLOFS method. The experimental studies on the 18 datasets demonstrate that the presented method performs consistently better than previous feature selection methods.

9.
Ann Surg ; 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38501245

RESUMEN

OBJECTIVE: This study aimed to investigate the clinical significance and risk factors of postoperative pancreatic fistula (POPF) after post-pancreatectomy acute pancreatitis (PPAP) in patients who underwent pancreaticoduodenectomy (PD). SUMMARY BACKGROUND DATA: PPAP has been recognized as a critical factor in the pathophysiology of POPF after PD. METHODS: A total of 817 consecutive patients who underwent elective PD between January 2020 and June 2022 were included. PPAP and POPF were defined in accordance with the International Study Group for Pancreatic Surgery (ISGPS) definitions. Multivariate logistic analyses were performed to investigate the risk factors for POPF. Comparisons between PPAP-associated POPF and non-PPAP-associated POPF were made to further characterize this intriguing complication. RESULTS: Overall, 159 (19.5%) patients developed POPF after PD, of which 73 (45.9%) occurred following PPAP, and the remaining 86 (54.1%) had non-PPAP-associated POPF. Patients with PPAP-associated POPF experienced significantly higher morbidity than patients without POPF. Multivariate analyses revealed distinct risk factors for each POPF type. For PPAP-associated POPF, independent risk factors included estimated blood loss >200 mL (OR 1.93), MPD ≤3 cm (OR 2.88), and soft pancreatic texture (OR 2.01), largely overlapping with FRS (Fistula Risk Score) elements. On the other hand, non-PPAP-associated POPF was associated with age >65 years (OR 1.95), male (OR 2.10), and MPD ≤3 cm (OR 2.57). Notably, among patients with PPAP, the incidence of POPF consistently hovered around 50% regardless of the FRS stratification. CONCLUSIONS: PPAP-associated POPF presents as a distinct pathophysiology in the development of POPF after PD, potentially opening doors for future prevention strategies targeting the early postoperative period.

10.
Insights Imaging ; 15(1): 77, 2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38499879

RESUMEN

OBJECTIVE: To appraise the quality of guidelines on intravenous iodinated contrast media (ICM) use in patients with kidney disease, and to compare the recommendations among them. METHODS: We searched four literature databases, eight guideline libraries, and ten homepages of radiological societies to identify English and Chinese guidelines on intravenous ICM use in patients with kidney disease published between January 2018 and June 2023. The quality of the guidelines was assessed with the Scientific, Transparent, and Applicable Rankings (STAR) tool. RESULTS: Ten guidelines were included, with a median STAR score of 46.0 (range 28.5-61.5). The guidelines performed well in "Recommendations" domain (31/40, 78%), while poor in "Registry" (0/20, 0%) and "Protocol" domains (0/20, 0%). Nine guidelines recommended estimated glomerular filtration rate (eGFR) < 30 mL/min/1.73 m2 as the cutoff for referring patients to discuss the risk-benefit balance of ICM administration. Three guidelines further suggested that patients with an eGFR < 45 mL/min/1.73 m2 and high-risk factors also need referring. Variable recommendations were seen in the acceptable time interval between renal function test and ICM administration, and that between scan and repeated scan. Nine guidelines recommended to use iso-osmolar or low-osmolar ICM, while no consensus has been reached for the dosing of ICM. Nine guidelines supported hydration after ICM use, but their protocols varied. Drugs or blood purification therapy were not recommended as preventative means. CONCLUSION: Guidelines on intravenous ICM use in patients with kidney disease have heterogeneous quality. The scientific societies may consider joint statements on controversial recommendations for variable timing and protocols. CRITICAL RELEVANCE STATEMENT: The heterogeneous quality of guidelines, and their controversial recommendations, leave gaps in workflow timing, dosing, and post-administration hydration protocols of contrast-enhanced CT scans for patients with kidney diseases, calling for more evidence to establish a safer and more practicable workflow. KEY POINTS: • Guidelines concerning iodinated contrast media use in kidney disease patients vary. • Controversy remains in workflow timing, contrast dosing, and post-administration hydration protocols. • Investigations are encouraged to establish a safer iodinated contrast media use workflow.

11.
J Imaging Inform Med ; 37(1): 123-133, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38343265

RESUMEN

This study aims to investigate the influence of adaptive statistical iterative reconstruction-V (ASIR-V) and deep learning image reconstruction (DLIR) on CT radiomics feature robustness. A standardized phantom was scanned under single-energy CT (SECT) and dual-energy CT (DECT) modes at standard and low (20 and 10 mGy) dose levels. Images of SECT 120 kVp and corresponding DECT 120 kVp-like virtual monochromatic images were generated with filtered back-projection (FBP), ASIR-V at 40% (AV-40) and 100% (AV-100) blending levels, and DLIR algorithm at low (DLIR-L), medium (DLIR-M), and high (DLIR-H) strength levels. Ninety-four features were extracted via Pyradiomics. Reproducibility of features was calculated between standard and low dose levels, between reconstruction algorithms in reference to FBP images, and within scan mode, using intraclass correlation coefficient (ICC) and concordance correlation coefficient (CCC). The average percentage of features with ICC > 0.90 and CCC > 0.90 between the two dose levels was 21.28% and 20.75% in AV-40 images, and 39.90% and 35.11% in AV-100 images, respectively, and increased from 15.43 to 45.22% and from 15.43 to 44.15% with an increasing strength level of DLIR. The average percentage of features with ICC > 0.90 and CCC > 0.90 in reference to FBP images was 26.07% and 25.80% in AV-40 images, and 18.88% and 18.62% in AV-100 images, respectively, and decreased from 27.93 to 17.82% and from 27.66 to 17.29% with an increasing strength level of DLIR. DLIR and ASIR-V algorithms showed low reproducibility in reference to FBP images, while the high-strength DLIR algorithm provides an opportunity for minimizing radiomics variability due to dose reduction.

12.
Curr Cancer Drug Targets ; 24(6): 654-667, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38419344

RESUMEN

BACKGROUND: Lung adenocarcinoma (LUAD) is a major health challenge worldwide with an undesirable prognosis. LINC00982 has been implicated as a tumor suppressor in diverse human cancers; however, its role in LUAD has not been fully characterized. METHODS: Expression level and prognostic value of LINC00982 were investigated in pan-cancer and lung cancer from The Cancer Genome Atlas (TCGA) project. Differential expression analysis based on the LINC00982 expression level was performed in LUAD followed by gene set enrichment analysis (GSEA) and functional enrichment analyses. The association between LINC00982 expression and tumor immune microenvironment characteristics was evaluated. A potential ceRNA regulatory axis was identified and experimentally validated. RESULTS: We found that LINC00982 expression was downregulated and correlated with poor prognosis in LUAD. Enrichment analyses revealed that LINC00982 could inhibit DNA damage repair and cell proliferation, but enhance tumor metabolic reprogramming. We identified a competing endogenous RNA network involving LINC00982, miR-183-5p, and ATP-binding cassette subfamily A member 8 (ABCA8). Luciferase assays confirmed that miR-183-5p can interact with LINC00982 and ABCA8. Forced miR-183-5p expression reduced LINC00982 transcript levels and suppressed ABCA8 expression. CONCLUSIONS: Our findings revealed the LINC00982/miR-183-5p/ABCA8 axis as a potential therapeutic target in LUAD.


Asunto(s)
Transportadoras de Casetes de Unión a ATP , Adenocarcinoma del Pulmón , Proliferación Celular , Biología Computacional , Regulación Neoplásica de la Expresión Génica , Neoplasias Pulmonares , MicroARNs , ARN Largo no Codificante , Humanos , MicroARNs/genética , ARN Largo no Codificante/genética , Adenocarcinoma del Pulmón/genética , Adenocarcinoma del Pulmón/patología , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/metabolismo , Transportadoras de Casetes de Unión a ATP/genética , Transportadoras de Casetes de Unión a ATP/metabolismo , Pronóstico , Animales , Ratones , Progresión de la Enfermedad , Microambiente Tumoral , Línea Celular Tumoral , Ratones Desnudos
14.
Eur Radiol ; 34(1): 6-15, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37505246

RESUMEN

OBJECTIVES: To assess the association between the enhancement pattern of the pancreatic parenchyma on preoperative multiphasic contrast-enhanced computed tomography (CECT) and the occurrence of postpancreatectomy acute pancreatitis (PPAP) after pancreaticoduodenectomy (PD). METHODS: A total of 513 patients who underwent PD were retrospective enrolled. The CT attenuation values of the nonenhanced (N), arterial (A), portal venous (P), and late (L) phases in the pancreatic parenchyma were measured on preoperative multiphasic CECT. The enhancement pattern was quantized by the CT attenuation value ratios in each phase. Receiver operating characteristic (ROC) curve analyses were computed to evaluate predictive performance. Regression analyses were used to identify independent risk factors for PPAP. RESULTS: PPAP developed in 102 patients (19.9%) and was associated with increased morbidity and a worse postoperative course. The A/P ratio, P/L ratio, and A/L ratio were significantly higher in the PPAP group. On the ROC analysis, the A/L ratio and A/P ratio both performed well in predicting PPAP (A/L: AUC = 0.7579; A/P: AUC = 0.7497). On multivariate analyses, the A/L ratio > 1.29 (OR 4.30 95% CI: 2.62-7.06, p < 0.001) and A/P ratio > 1.13 (OR 5.02 95% CI: 2.98-8.45, p < 0.001) were both independent risk factors of PPAP in each model. CONCLUSIONS: The enhancement pattern of the pancreatic parenchyma on multiphasic preoperative CECT is a good predictor of the occurrence of PPAP after PD, which could help clinicians identify high-risk patients or enable selective enhance recovery protocols. CLINICAL RELEVANCE STATEMENT: Preoperative identification of patients at high risk for postpancreatectomy acute pancreatitis by enhancement patterns of the pancreatic parenchyma allows surgeons to tailor their perioperative management and take precautions. KEY POINTS: PPAP is associated with increased risk of postoperative complications and a worse postoperative course. A rapid-decrease enhancement pattern of the pancreatic parenchyma is related to the occurrence of PPAP. The A/L and A/P ratios were both independent risk factors of PPAP in each multivariate model.


Asunto(s)
Pancreatitis , Propilaminas , Humanos , Pancreatitis/diagnóstico por imagen , Pancreatitis/etiología , Pancreaticoduodenectomía/efectos adversos , Estudios Retrospectivos , Enfermedad Aguda , Fístula Pancreática/etiología , Factores de Riesgo , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/etiología
15.
BMC Med Res Methodol ; 23(1): 292, 2023 12 13.
Artículo en Inglés | MEDLINE | ID: mdl-38093215

RESUMEN

BACKGROUND: Complete reporting is essential for clinical research. However, the endorsement of reporting guidelines in radiological journals is still unclear. Further, as a field extensively utilizing artificial intelligence (AI), the adoption of both general and AI reporting guidelines would be necessary for enhancing quality and transparency of radiological research. This study aims to investigate the endorsement of general reporting guidelines and those for AI applications in medical imaging in radiological journals, and explore associated journal characteristic variables. METHODS: This meta-research study screened journals from the Radiology, Nuclear Medicine & Medical Imaging category, Science Citation Index Expanded of the 2022 Journal Citation Reports, and excluded journals not publishing original research, in non-English languages, and instructions for authors unavailable. The endorsement of fifteen general reporting guidelines and ten AI reporting guidelines was rated using a five-level tool: "active strong", "active weak", "passive moderate", "passive weak", and "none". The association between endorsement and journal characteristic variables was evaluated by logistic regression analysis. RESULTS: We included 117 journals. The top-five endorsed reporting guidelines were CONSORT (Consolidated Standards of Reporting Trials, 58.1%, 68/117), PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses, 54.7%, 64/117), STROBE (STrengthening the Reporting of Observational Studies in Epidemiology, 51.3%, 60/117), STARD (Standards for Reporting of Diagnostic Accuracy, 50.4%, 59/117), and ARRIVE (Animal Research Reporting of In Vivo Experiments, 35.9%, 42/117). The most implemented AI reporting guideline was CLAIM (Checklist for Artificial Intelligence in Medical Imaging, 1.7%, 2/117), while other nine AI reporting guidelines were not mentioned. The Journal Impact Factor quartile and publisher were associated with endorsement of reporting guidelines in radiological journals. CONCLUSIONS: The general reporting guideline endorsement was suboptimal in radiological journals. The implementation of reporting guidelines for AI applications in medical imaging was extremely low. Their adoption should be strengthened to facilitate quality and transparency of radiological study reporting.


Asunto(s)
Inteligencia Artificial , Publicaciones Periódicas como Asunto , Humanos , Lista de Verificación , Edición , Estándares de Referencia
16.
J Magn Reson Imaging ; 2023 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-38112305

RESUMEN

BACKGROUND: Quantitative diffusion metrics provide additional microstructural information of diseases. The robustness of quantitative diffusion metrics should be established before clinical application. PURPOSE: To evaluate the variability and reproducibility of quantitative diffusion MRI metrics. STUDY TYPE: Prospective. POPULATION: 14 volunteers (7 men; median age, range, 28, 26-59 years). FIELD STRENGTH/SEQUENCE: 3.0-T/Diffusion spectrum imaging. ASSESSMENT: Brain MRI studies were performed four times per subject: involving different combinations of coil types and voxel sizes. Regions of interest of 13 brain anatomical sites were drawn by one observer twice and another observer once to allow interobserver and intraobserver reproducibility assessment. Twenty-five quantitative metrics were calculated using four diffusion models. STATISTICAL TESTS: The variability was evaluated with coefficients of variation (CV), and quartile coefficient of dispersion (QCD). The reproducibility was assessed with intraclass correlation coefficient (ICC), and concordance correlation coefficient (CCC). Wilcoxon signed rank test was used to compare the influence of factors on robustness of quantitative diffusion metrics. A two-tailed P < 0.05 was considered statistically significant. RESULTS: The variability of quantitative diffusion metrics showed CV of 2.4%-68.2%, and QCD of 0.6%-48.2%, respectively. The reproducibility of scans using 20-channel coils with voxels of 2 × 2 × 2 mm3 and 3 × 3 × 3 mm3 , respectively (ICC 0.03-0.84, CCC 0.03-0.84) was significantly worse than that of repeated scans using a 20-channel coil with a voxel size of 2 × 2 × 2 mm3 (ICC of 0.74-0.97, CCC 0.74-0.97) and that of scans using 20- and 64-channel coils, respectively, with a voxel size of 2 × 2 × 2 mm3 (ICC 0.59-0.95, CCC 0.59-0.95). The intraobserver reproducibility (ICC 0.49-0.94, CCC 0.49-0.94) was significantly better than the interobserver reproducibility (ICC 0.28-0.91, CCC 0.28-0.91). DATA CONCLUSION: Our study indicated that the voxel size has a greater influence on the reproducibility of quantitative diffusion metrics than scan-rescans and coils. The reproducibility within one observer was higher than that between two observers. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 1.

17.
BMC Musculoskelet Disord ; 24(1): 678, 2023 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-37626375

RESUMEN

BACKGROUND: The peripatellar fat pads are critical for protective cushioning during movement, and their endocrine function has been shown to affect osteoarthritis. Magnetic resonance imaging (MRI) is frequently used to visualize edema of the peripatellar fat pads due to injury. In this study, we aimed to assess the relationship between peripatellar fat pad edema and patellofemoral maltracking MRI parameters and investigate the association among cases of peripatellar fat pad edema. METHODS: Age- and sex-matched peripatellar fat pad edema cases were identified and divided into superolateral Hoffa, quadriceps, and prefemoral groups. Images were assessed according to tibial tuberosity lateralization, trochlear dysplasia, patellar alta, patellar tilt, and bisect offset. McNemar's test or paired t-tests and Spearman's correlation were used for statistical analysis. Interobserver agreement was assessed with the intraclass correlation coefficient. RESULTS: Of 1210 MRI scans, 50, 68, and 42 cases were in the superolateral Hoffa, quadriceps, and prefemoral groups, respectively. Subjects with superolateral Hoffa fat pad edema had a lower lateral trochlear inclination (p = 0.028), higher Insall-Salvati (p < 0.001) and modified Insall-Salvati (p = 0.021) ratios, and lower patellotrochlear index (p < 0.001) than controls. The prefemoral group had a lower lateral trochlear inclination (p = 0.014) and higher Insall-Salvati (p < 0.001) and modified Insall-Salvati (p = 0.004) ratios compared with the control group. In contrast, the patellotrochlear index (p = 0.001) was lower. Mean patellar tilt angle (p = 0.019) and mean bisect offset (p = 0.005) were significantly different between cases and controls. The quadriceps group showed no association. Superolateral Hoffa was positively correlated with prefemoral (p < 0.001, r = 0.408) and negatively correlated with quadriceps (p < 0.001, r = -0.500) fat pad edema. CONCLUSIONS: Superolateral Hoffa and prefemoral fat pad edemas were associated with patellar maltracking parameters. Quadriceps fat pad edema and maltracking parameters were not associated. Superolateral Hoffa fat pad edema was positively correlated with prefemoral and negatively correlated with quadriceps fat pad edema.


Asunto(s)
Enfermedades Óseas , Artropatías , Humanos , Tejido Adiposo/diagnóstico por imagen , Estudios de Casos y Controles , Edema/diagnóstico por imagen , Imagen por Resonancia Magnética
18.
J Orthop Surg Res ; 18(1): 414, 2023 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-37287036

RESUMEN

PURPOSE: To systematically assess the quality of radiomics research in giant cell tumor of bone (GCTB) and to test the feasibility of analysis at the level of radiomics feature. METHODS: We searched PubMed, Embase, Web of Science, China National Knowledge Infrastructure, and Wanfang Data to identify articles of GCTB radiomics until 31 July 2022. The studies were assessed by radiomics quality score (RQS), transparent reporting of a multivariable prediction model for individual prognosis or diagnosis (TRIPOD) statement, checklist for artificial intelligence in medical imaging (CLAIM), and modified quality assessment of diagnostic accuracy studies (QUADAS-2) tool. The radiomic features selected for model development were documented. RESULTS: Nine articles were included. The average of the ideal percentage of RQS, the TRIPOD adherence rate and the CLAIM adherence rate were 26%, 56%, and 57%, respectively. The risk of bias and applicability concerns were mainly related to the index test. The shortness in external validation and open science were repeatedly emphasized. In GCTB radiomics models, the gray level co-occurrence matrix features (40%), first order features (28%), and gray-level run-length matrix features (18%) were most selected features out of all reported features. However, none of the individual feature has appeared repeatably in multiple studies. It is not possible to meta-analyze radiomics features at present. CONCLUSION: The quality of GCTB radiomics studies is suboptimal. The reporting of individual radiomics feature data is encouraged. The analysis at the level of radiomics feature has potential to generate more practicable evidence for translating radiomics into clinical application.


Asunto(s)
Neoplasias Óseas , Tumor Óseo de Células Gigantes , Humanos , Inteligencia Artificial , Tumor Óseo de Células Gigantes/diagnóstico por imagen , Diagnóstico por Imagen , Biomarcadores , Neoplasias Óseas/diagnóstico por imagen
19.
Eur Radiol ; 33(11): 8214-8225, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37328640

RESUMEN

OBJECTIVE: To assess the prognostic value of myocardial salvage index (MSI) by cardiac magnetic resonance (CMR) in ST-segment elevation myocardial infarction (STEMI) patients. METHODS: We systematically searched PubMed, Embase, Web of Science, Cochrane Central, China National Knowledge Infrastructure, and Wanfang Data to identify primary studies reporting MSI in STEMI patients with major adverse cardiovascular events (MACE) comprised of death, myocardial reinfarction, and congestive heart failure. The MSI and MACE rates were pooled. The bias of risk was assessed using the Quality In Prognosis Studies tool. The evidence level was rated based on the meta-analysis of hazard ratio (HR) and 95% confidence interval (CI) of MSI for predicting MACE. RESULTS: Eighteen studies were included covering twelve unique cohorts. Eleven cohorts measured MSI using T2-weighted imaging and T1-weighted late gadolinium enhancement, while one cohort applied T2-mapping and T1-mapping. The pooled MSI (95% CI) was 44% (39 to 49%; 11 studies, 2946 patients), and the pooled MACE rate (95% CI) was 10% (7 to 14%; 12 studies, 311/3011 events/patients). Seven prognostic studies overall showed low risk of bias. The HR (95% CI) per 1% increase of MSI for MACE was 0.95 (0.92 to 0.98; 5 studies, 150/885 events/patients), and HR (95% CI) of MSI < median versus MSI > median for MACE was 5.62 (3.74 to 8.43; 6 studies, 166/1570 events/patients), both rated as weak evidence. CONCLUSIONS: MSI presents potential in predicting MACE in STEMI patients. The prognostic value of MSI using advanced CMR techniques for adverse cardiovascular events needs further investigation. CLINICAL RELEVANCE STATEMENT: Seven studies supported the MSI to serve as a predictor for MACE in STEMI patients, indicating its potential as a risk stratification tool to help manage expectations for these patients in clinical practice. KEY POINTS: • The pooled infarct size (95% CI) and area at risk (95% CI) were 21% (18 to 23%; 11 studies, 2783 patients) and 38% (34 to 43%; 10 studies, 2022 patients), respectively. • The pooled rates (95% CI) of cardiac mortality, myocardial reinfarction, and congestive heart failure were 2% (1 to 3%; 11 studies, 86/2907 events/patients), 4% (3 to 6%; 12 studies, 127/3011 events/patients), and 3% (1 to 5%; 12 studies, 94/3011 events/patients), respectively. • The HRs (95% CI) per 1% increase of MSI for cardiac mortality and congestive heart failure were 0.93 (0.91 to 0.96; 1 study, 14/202 events/patients) and 0.96 (0.93 to 0.99; 1 study, 11/104 events/patients), respectively, but the prognostic value of MSI for myocardial re-infraction has not been measured.


Asunto(s)
Insuficiencia Cardíaca , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , Pronóstico , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Medios de Contraste , Gadolinio/farmacología , Insuficiencia Cardíaca/etiología , Espectroscopía de Resonancia Magnética , Imagen por Resonancia Cinemagnética/métodos , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas
20.
Insights Imaging ; 14(1): 111, 2023 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-37336830

RESUMEN

OBJECTIVE: To conduct an overview of meta-analyses of radiomics studies assessing their study quality and evidence level. METHODS: A systematical search was updated via peer-reviewed electronic databases, preprint servers, and systematic review protocol registers until 15 November 2022. Systematic reviews with meta-analysis of primary radiomics studies were included. Their reporting transparency, methodological quality, and risk of bias were assessed by PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) 2020 checklist, AMSTAR-2 (A MeaSurement Tool to Assess systematic Reviews, version 2) tool, and ROBIS (Risk Of Bias In Systematic reviews) tool, respectively. The evidence level supporting the radiomics for clinical use was rated. RESULTS: We identified 44 systematic reviews with meta-analyses on radiomics research. The mean ± standard deviation of PRISMA adherence rate was 65 ± 9%. The AMSTAR-2 tool rated 5 and 39 systematic reviews as low and critically low confidence, respectively. The ROBIS assessment resulted low, unclear and high risk in 5, 11, and 28 systematic reviews, respectively. We reperformed 53 meta-analyses in 38 included systematic reviews. There were 3, 7, and 43 meta-analyses rated as convincing, highly suggestive, and weak levels of evidence, respectively. The convincing level of evidence was rated in (1) T2-FLAIR radiomics for IDH-mutant vs IDH-wide type differentiation in low-grade glioma, (2) CT radiomics for COVID-19 vs other viral pneumonia differentiation, and (3) MRI radiomics for high-grade glioma vs brain metastasis differentiation. CONCLUSIONS: The systematic reviews on radiomics were with suboptimal quality. A limited number of radiomics approaches were supported by convincing level of evidence. CLINICAL RELEVANCE STATEMENT: The evidence supporting the clinical application of radiomics are insufficient, calling for researches translating radiomics from an academic tool to a practicable adjunct towards clinical deployment.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...