Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Nat Commun ; 14(1): 1993, 2023 04 08.
Artículo en Inglés | MEDLINE | ID: mdl-37031188

RESUMEN

PD-1/PD-L1 blockade therapy that eliminates T-cell inhibition signals is successful, but poor benefits are often observed. Increasing T-cell infiltration and quantity of PD-1/PD-L1 inhibitors in tumor can improve efficacy but remains challenging. Here, we devise tumor-specific gene nanomedicines to mobilize tumor cells to secrete CXCL9 (T-cell chemokine) and anti-PD-L1 scFv (αPD-L1, PD-L1 blocking agent) for enhanced immunotherapy. The tyrosinase promoter-driven NPTyr-C9AP can specifically co-express CXCL9 and αPD-L1 in melanoma cells, thereby forming a CXCL9 gradient for T-cell recruitment and high intratumoral αPD-L1 concentration for enhancing T-cell activation. As a result, NPTyr-C9AP shows strong antimelanoma effects. Moreover, specific co-expression of CXCL9 and αPD-L1 in various tumor cells is achieved by replacing the tyrosinase promoter of NPTyr-C9AP with a survivin promoter, which increases T-cell infiltration and activation and therapeutic efficacy in multiple tumors in female mice. This study provides a strategy to maximize the immunotherapeutic outcome regardless of the heterogeneous tumor microenvironment.


Asunto(s)
Neoplasias , Linfocitos T , Femenino , Ratones , Animales , Receptor de Muerte Celular Programada 1 , Monofenol Monooxigenasa , Nanomedicina , Inmunoterapia , Antígeno B7-H1/genética , Microambiente Tumoral , Línea Celular Tumoral
2.
J Chromatogr A ; 1492: 41-48, 2017 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-28284764

RESUMEN

Four HD urinary metabolites including hydrolysis metabolite thiodiglycol (TDG), glutathione-derived metabolite 1,1'-sulfonylbis[2-S-(N-acetylcysteinyl)ethane] (SBSNAE), as well as the ß-lyase metabolites 1,1'-sulfonylbis[2-(methylsulfinyl)ethane] (SBMSE) and 1-methylsulfinyl-2-[2-(methylthio) ethylsulfonyl]ethane (MSMTESE) are considered as important biomarkers for short-term retrospective detection of HD exposure. In this study, a single method for simultaneous quantification of the four HD metabolites in urine samples was developed using ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). The four urinary metabolites were simultaneously extracted from urinary samples using a solid phase extraction (SPE) method with high extraction recoveries for all four metabolites varied in the range of 71.1-103% followed by UHPLC-MS/MS analysis. The SPE is simple and high effective only requiring 0.1mL of urinary samples and 0.5h time consuming. The problem of previous co-elution of TDG and SBSNAE in UHPLC was well solved, and complete separation of TDG, SBSNAE, SBMSE and MSMTESE from SPE-processed urine matrix was obtained to increase specificity and sensitivity. A full method validation was performed for each analyte in urine matrix. The linear range of calibration curves for the four analytes were respectively from 0.50-500ngmL-1 for TDG and SBSNAE, 0.05-500ngmL-1 for SBMSE and MSMTESE with coefficient of determination value (R2) ≥0.990. The limit of detection was 0.25ngmL-1 for TDG and SBSNAE, 0.01ngmL-1 for SBMSE and MSMTESE spiked in normal urine. The intra/inter-day precision for each analyte at three QC levels had relative standard deviation (%RSD) of ≤10.3%, and the intra/inter-day accuracy ranged between 88.0-108%. This developed method allows for simultaneous and trace measurement of four HD urinary metabolites within one single determination with the lowest usage amount of urine samples over all previous methods This study provides a useful tool for early diagnosis and monitoring of HD poisoning for medical treatment with high confidence, avoiding the need for application of several analysis methods.


Asunto(s)
Sustancias para la Guerra Química/metabolismo , Gas Mostaza/metabolismo , Acetatos/química , Biomarcadores/orina , Sustancias para la Guerra Química/análisis , Sustancias para la Guerra Química/aislamiento & purificación , Cromatografía Líquida de Alta Presión , Humanos , Gas Mostaza/análisis , Gas Mostaza/aislamiento & purificación , Reproducibilidad de los Resultados , Extracción en Fase Sólida , Compuestos de Sulfhidrilo/aislamiento & purificación , Compuestos de Sulfhidrilo/orina , Espectrometría de Masas en Tándem
3.
J Chromatogr B Analyt Technol Biomed Life Sci ; 1036-1037: 57-65, 2016 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-27718463

RESUMEN

This work describes a novel and sensitive non-isotope dilution method for simultaneous quantification of organophosphorus nerve agents (OPNAs) soman (GD) and VX adducts to butyrylcholinesterase (BChE), their aged methylphosphonic acid (MeP) adduct and unadducted BChE in plasma exposed to OPNA. OPNA-BChE adducts were isolated with an off-column procainamide-gel separation (PGS) from plasma, and then digested with pepsin into specific adducted FGES*AGAAS nonapeptide (NP) biomarkers. The resulting NPs were detected by UHPLC-MS/MS MRM. The off-column PGS method can capture over 90% of BChE, MeP-BChE, VX-BChE and GD-BChE from their respective plasma materials. One newly designed and easily synthesized phosphorylated BChE nonapeptide with one Gly-to-Ala mutation was successfully reported to serve as internal standard instead of traditional isotopically labeled BChE nonapeptide. The linear range of calibration curves were from 1.00-200ngmL-1 for VX-NP, 2.00-200ngmL-1 for GD-NP and MeP-NP (R2≥0.995), and 3.00-200ngmL-1 for BChE NP (R2≥0.990). The inter-day precision had relative standard deviation (%RSD) of <8.89%, and the accuracy ranged between 88.9-120%. The limit of detection was calculated to be 0.411, 0.750, 0.800 and 1.43ngmL-1 for VX-NP, GD-NP, MeP-NP and BChE NP, respectively. OPNA-exposed quality control plasma samples were characterized as part of method validation. Investigation of plasma samples unexposed to OPNA revealed no baseline values or interferences. Using the off-column PGS method combined with UHPLC-MS/MS, VX-NP and GD-NP adducts can be unambiguously detected with high confidence in 0.10ngmL-1 and 0.50ngmL-1 of exposed human plasma respectively, only requiring 0.1mL of plasma sample and taking about four hours without special sample preparation equipment. These improvements make it a simple, sensitive and robust PGS-UHPLC-MS/MS method, and this method will become an attractive alternative to immunomagnetic separation (IMS) method and a useful diagnostic tool for retrospective detection of OPNA exposure with high confidence. Furthermore, using the developed method, the adducted BChE levels from VX and GD-exposed (0.10-100ngmL-1) plasma samples were completely characterized, and the fact that VX being more active and specific to BChE than GD was re-confirmed.


Asunto(s)
Butirilcolinesterasa/sangre , Sustancias para la Guerra Química/farmacocinética , Inhibidores de la Colinesterasa/sangre , Compuestos Organofosforados/sangre , Compuestos Organotiofosforados/sangre , Soman/sangre , Espectrometría de Masas en Tándem/métodos , Butirilcolinesterasa/aislamiento & purificación , Inhibidores de la Colinesterasa/aislamiento & purificación , Cromatografía Líquida de Alta Presión/instrumentación , Cromatografía Líquida de Alta Presión/métodos , Diseño de Equipo , Geles/química , Humanos , Límite de Detección , Compuestos Organofosforados/aislamiento & purificación , Compuestos Organotiofosforados/aislamiento & purificación , Procainamida/química , Soman/aislamiento & purificación , Espectrometría de Masas en Tándem/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...