Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
J Magn Reson Imaging ; 59(3): 1034-1042, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37272790

RESUMEN

BACKGROUND: The assessment of resectability after neoadjuvant chemotherapy of hepatoblastoma is dependent on Post-Treatment EXTENT of Disease (POSTTEXT) staging and its annotation factors P (portal venous involvement) and V (hepatic venous/inferior vena cava [IVC] involvement), but MR performance in assessing them remains unclear. PURPOSE: To assess the diagnostic performance of contrast-enhanced MR imaging for preoperative POSTTEXT staging and diagnosing vascular involvement in terms of annotation factors P and V in pediatric hepatoblastoma following neoadjuvant chemotherapy. STUDY TYPE: Retrospective. SUBJECTS: Thirty-five consecutive patients (17 males, median age, 24 months; age range, 6-98 months) with proven hepatoblastoma underwent preoperative MR imaging following neoadjuvant chemotherapy. FIELD STRENGTH/SEQUENCE: 3.0 T; T2-weighted imaging (T2WI), T2WI with fat suppression, diffusion weighted imaging, radial stack-of-the-star/Cartesian 3D Dixon T1-weighted gradient echo imaging. ASSESSMENT: Three radiologists independently assessed the POSTTEXT stages and annotation factors P and V based on the 2017 PRE/POSTTEXT system. The sensitivities and specificities were calculated for 1) diagnosing each POSTTEXT stage; 2) discrimination of stages III and IV (advanced) from those stages I and II (non-advanced) hepatoblastomas; and 3) annotation factors P and V. The combination of pathologic findings and surgical records served as the reference standard. STATISTICAL TESTS: Sensitivity, specificity, Fleiss kappa test. RESULTS: The sensitivity and specificity ranges for discriminating advanced from non-advanced hepatoblastomas were 73.3%-80.0% and 80.0%-90.0%, respectively. For annotation factor P, they were 66.7%-100.0% and 90.6%, respectively. For factor V, they were 75.0% and 67.7%-83.9%, respectively. There was excellent, substantial, and moderate agreement on POSTTEXT staging (Fleiss kappa = 0.82), factors P (Fleiss kappa = 0.64), and factors V (Fleiss kappa = 0.60), respectively. DATA CONCLUSION: MR POSTTEXT provides reliable discrimination between advanced and non-advanced tumors, and MR has moderate to excellent specificity at identifying portal venous and hepatic venous/IVC involvement. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 3.


Asunto(s)
Hepatoblastoma , Neoplasias Hepáticas , Masculino , Niño , Humanos , Preescolar , Lactante , Hepatoblastoma/tratamiento farmacológico , Hepatoblastoma/patología , Hepatoblastoma/cirugía , Terapia Neoadyuvante , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Venas Hepáticas , Sensibilidad y Especificidad , Neoplasias Hepáticas/patología , Estadificación de Neoplasias
2.
Abdom Radiol (NY) ; 42(9): 2233-2242, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28401282

RESUMEN

PURPOSE: To determine reliable CT features to distinguish cancerous from inflammatory colorectal perforations. MATERIALS AND METHODS: A total of 43 patients with surgically and pathologically confirmed colorectal perforation caused by either colorectal cancer (n =27) or an inflammatory conditions (n = 16) were identified. Two radiologists independently assessed the contrast-enhanced CT features for locations of perforation, mural configurations, soft-tissue alterations, lymphadenopathy, and metastases. Intergroup comparisons for univariate analysis were performed using Fisher's exact test or chi-square test for categorical data and Mann-Whitney test for numeric data. Stepwise logistic regression analysis was conducted with features that were found significant under the univariate analysis. Interobserver agreement was assessed using intraclass correlation coefficient (ICC) and kappa test. RESULTS: Maximal mural thickness >1.39 cm (sensitivity, 100%; specificity, 68.75%), luminal mass or shoulder formation (sensitivity, 88.89%; specificity, 68.75%), absence of diverticula (sensitivity, 96.30%; specificity, 50.00%), irregular mural thickening (sensitivity, 92.59%; specificity, 81.25%), lymphadenopathy (sensitivity, 40.74%; specificity, 93.75%), and metastases (sensitivity, 25.93%; specificity, 100%) were significantly frequent in cancerous perforations. The maximal mural thickness (P = 0.0493, odds ratio = 439.83) and irregular mural thickening (P = 0.0343, odds ratio = 4.69) were identified as the highly distinguished identifiers. CONCLUSIONS: The CT manifestations of cancerous and inflammatory colorectal perforations overlap. Definitive diagnosis is not always possible with imaging alone. The maximal mural thickness >1.39 cm and irregular configuration of the thickened bowel wall were the two highly statistically significant CT features that may help order the difference between the two entities.


Asunto(s)
Neoplasias Colorrectales/complicaciones , Neoplasias Colorrectales/diagnóstico por imagen , Enfermedades Inflamatorias del Intestino/complicaciones , Enfermedades Inflamatorias del Intestino/diagnóstico por imagen , Perforación Intestinal/diagnóstico por imagen , Perforación Intestinal/etiología , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Diagnóstico Diferencial , Femenino , Humanos , Yopamidol , Metástasis Linfática/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad
3.
J Zhejiang Univ Sci B ; 18(3): 272-276, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28271663

RESUMEN

The increasing incidence of morbidly adherent placenta (MAP) is placing women at a higher risk of life-threatening massive hemorrhage. The involvement of interventional radiology to manage this complex condition by performing prophylactic iliac artery balloon occlusion has been reported recently. However, the effectiveness and safety of this technique have not been fully determined. Here we report the case of a 25-year-old woman with placenta increta with preemptive bilateral internal iliac artery balloons who had external iliac artery thrombosis detected by computed tomography angiography (CTA) 72 h post cesarean section. A digital subtraction angiogram (DSA) and intra-arterial thrombolysis were instantly performed followed by supplementary conservative treatments, leading to a desirable resolution of thrombus without sequela. This is the first report of vascular complications with successful interventional thrombolysis in this setting. Our experience suggests that prophylactic iliac artery balloon occlusion should be used cautiously in cases of MAP and consideration given to minimizing vascular complications given the hypercoagulable state of pregnancy.


Asunto(s)
Oclusión con Balón/efectos adversos , Arteria Ilíaca/cirugía , Placenta Accreta/cirugía , Terapia Trombolítica/métodos , Adulto , Angiografía de Substracción Digital , Coagulación Sanguínea , Pérdida de Sangre Quirúrgica/prevención & control , Cateterismo , Cesárea , Femenino , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Tomografía Computarizada Multidetector , Placenta/cirugía , Embarazo , Enfermedades Vasculares
4.
Hepatobiliary Pancreat Dis Int ; 15(4): 391-8, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27498579

RESUMEN

BACKGROUND: Pyogenic hepatic abscess may mimic primary or secondary carcinoma of the liver on contrast-enhanced computed tomography (CECT). The present study was to explore the usefulness of the analysis of multislice-based texture acquired from CECT in the differentiation between pyogenic hepatic abscesses and malignant mimickers. METHODS: This retrospective study included 25 abscesses in 20 patients and 33 tumors in 26 subjects who underwent CECT. To make comparison, we also enrolled 19 patients with hepatic single simple cyst. The images from CECT were analyzed using a Laplacian of Gaussian band-pass filter (5 filter levels with sigma weighting ranging from 1.0 to 2.5). We also quantified the uniformity, entropy, kurtosis and skewness of the multislice-based texture at different sigma weightings. Statistical significance for these parameters was tested with one-way ANOVA followed by Tukey honestly significant difference (HSD) test. Diagnostic performance was evaluated using the receiver operating characteristic (ROC) curve analysis. RESULTS: There were significant differences in entropy and uniformity at all sigma weightings (P<0.001) among hepatic abscesses, malignant mimickers and simple cysts. The significant difference in kurtosis and skewness was shown at sigma 1.8 and 2.0 weightings (P=0.002-0.006). Tukey HSD test showed that the abscesses had a significantly higher entropy and lower uniformity compared with malignant mimickers (P=0.000-0.004). Entropy (at a sigma 2.0 weighting) had the largest area under the ROC curve (0.888) in differentiating abscesses from malignant mimickers, with a sensitivity of 81.8% and a specificity of 88.0% when the cutoff value was set to 3.64. CONCLUSION: Multislice-based texture analysis may be useful for differentiating pyogenic hepatic abscesses from malignant mimickers.


Asunto(s)
Medios de Contraste/administración & dosificación , Yohexol/análogos & derivados , Absceso Piógeno Hepático/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Tomografía Computarizada Multidetector/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Anciano , Anciano de 80 o más Años , Área Bajo la Curva , Diagnóstico Diferencial , Femenino , Humanos , Yohexol/administración & dosificación , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Curva ROC , Reproducibilidad de los Resultados , Estudios Retrospectivos
5.
Abdom Radiol (NY) ; 41(3): 545-52, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27039326

RESUMEN

PURPOSE: The aim of this study was to develop a quantitative measurement of perfusion reduction using color-coded digital subtraction angiography (ccDSA) to monitor intra-procedural arterial stasis during TACE. MATERIALS AND METHODS: A total number of 35 patients with hepatocellular carcinoma who had undergone TACE were enrolled into the study. Pre- and post-two-dimensional digital subtraction angiography scans were conducted with same protocol and post-processed with ccDSA prototype software. Time-contrast-intensity (CI[t]) curve was obtained by region-of-interest (ROI) measurement on the generated ccDSA image. Quantitative 2D perfusion parameters time to peak, area under the curve (AUC), maximum upslope, and contrast intensity peak (CI-Peak) derived from the ROI-based CI[t] curve for pre- and post-TACE were evaluated to assess the reduction of antegrade blood flow and tumor blush. Relationships between 2D perfusion parameters, subjective angiographic chemoembolization endpoint (SACE) scale, and clinical outcomes were analyzed. RESULTS: Area normalized AUC and CI-Peak revealed significant reduction after the TACE (P < 0.0001). AUCnorm decreased from pre-procedure of 0.867 ± 0.242 to 0.421 ± 0.171 (P < 0.001) after completion of TACE. CI-Peaknorm was 0.739 ± 0.221 before TACE and 0.421 ± 0.174 (P < 0.001) after TACE. Tumor blood supply time slowed down obviously after embolization. A perfusion reduction either from AUCnorm or CI-Peaknorm ranging from 30% to 40% was associated with SACE level III and a reduction ranging from 60% to 70% was equivalent to SACE level IV. For intermediate reduction (SACE level III), better tumor response was found after TACE rather than a higher reduction (SACE level IV). CONCLUSION: ccDSA application provides an objective approach to quantify the perfusion reduction and subjectively evaluate the arterial stasis of antegrade blood flow and tumor blush caused by TACE.


Asunto(s)
Angiografía de Substracción Digital/métodos , Carcinoma Hepatocelular/terapia , Quimioembolización Terapéutica/métodos , Neoplasias Hepáticas/terapia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos
6.
Br J Radiol ; 89(1062): 20140448, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27009758

RESUMEN

OBJECTIVE: To introduce a method in which a long sheath is used instead of the traditional short sheath, to reduce the radiation exposure of operators in uterine artery embolization (UAE). METHODS: 52 patients undergoing UAE were randomly divided into two groups before the procedure: an 11-cm short sheath was used in Group A (n = 25), and a 45-cm-long sheath was used in Group B (n = 27); the 45-cm-long sheath was only partly inserted such that the hub of the sheath was approximately 34 cm caudal to the groin puncture site. All the procedures were standard bilateral UAE operations through unilateral approach. The other parameters of the two groups were kept the same, including the fluoroscopy conditions and the pelvic radiation field size. The thermoluminescent personal dosemeters were attached to the left wrist and left outer side of the thyroid collar of the operator during each operation. The radiation exposure of the operator, procedure duration and fluoroscopy time of each procedure were recorded. Statistical analysis was performed using independent samples t-test. RESULTS: The radiation exposure of both the left hand and thyroid of the operator was significantly reduced with the long sheath compared with the short sheath (89.5 ± 7.2 µGy vs 186.7 ± 12.6 µGy, p < 0.001, and 54.1 ± 5.5 µGy vs 63.9 ± 7.4 µGy, p < 0.001, respectively). No significant differences were found in the procedure duration and fluoroscopy time between the two groups (p > 0.1). CONCLUSION: Using a long sheath in UAE could significantly reduce the radiation exposure to the interventionists without extending the procedure duration or fluoroscopy time. ADVANCES IN KNOWLEDGE: For the first time, we introduce a simple and convenient method to reduce the radiation exposure of the operator in the UAE procedure.


Asunto(s)
Cateterismo Periférico/instrumentación , Arteria Femoral/diagnóstico por imagen , Exposición a la Radiación/prevención & control , Protección Radiológica/instrumentación , Radiografía Intervencional/métodos , Embolización de la Arteria Uterina/instrumentación , Adulto , Cateterismo Periférico/métodos , Diseño de Equipo , Femenino , Humanos , Dosis de Radiación , Exposición a la Radiación/análisis , Protección Radiológica/métodos , Radiografía Intervencional/instrumentación , Dosimetría Termoluminiscente , Resultado del Tratamiento , Embolización de la Arteria Uterina/métodos , Adulto Joven
7.
Acta Radiol ; 56(5): 552-6, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-24917607

RESUMEN

BACKGROUND: The H7N9 strain of bird flu is a new type of avian flu that was identified at the end of March 2013. The disease is concerning because most patients have become severely ill. PURPOSE: To study the X-ray and computed tomography (CT) findings of early H7N9 avian influenza cases. MATERIAL AND METHODS: Chest radiography and CT were performed in six patients with H7N9 avian influenza within 1-20 days after onset. The CT examinations included conventional spiral CT and high-resolution CT. The findings on the radiography and CT images were analyzed. RESULTS: Abnormal X-ray and CT findings were present in all of the patients. All of the cases had acute onset. In the early stage, the right lung was more commonly affected (particularly in the right upper and middle lobes). The lesions rapidly expanded to the entire lungs and were characterized primarily by ground-glass opacities (GGOs) combined with consolidation. Diffuse GGO was observed in all six cases (1 was symmetric, and 5 were non-symmetric). Local consolidation was found in four cases, and lobar consolidation was found in two cases. Normal lung tissue was observed between the lesions. Pleural thickening was common and was combined with pleural/pericardial effusion or mediastinal lymph node enlargement. Reticular changes, centrilobular nodules, and the tree-in-bud sign were observed in some cases, but reticular changes, bronchial wall thickening, and hyperinflation were not found. CONCLUSION: Radiological changes associated with both acute pneumonia and acute interstitial inflammation were observed in early H7N9 avian influenza cases. Serial chest X-rays were useful for the diagnosis and severity assessment of the disease. CT may provide a more accurate assessment of the lung pathology.


Asunto(s)
Subtipo H7N9 del Virus de la Influenza A , Gripe Humana/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Radiografía Torácica/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada Espiral/métodos
8.
Behav Brain Funct ; 10: 20, 2014 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-24885073

RESUMEN

BACKGROUND: Recent studies suggest that Internet gaming addiction (IGA) is an impulse disorder, or is at least related to impulse control disorders. In the present study, we hypothesized that different facets of trait impulsivity may be specifically linked to the brain regions with impaired impulse inhibition function in IGA adolescents. METHODS: Seventeen adolescents with IGA and seventeen healthy controls were scanned during performance of a response-inhibition Go/No-Go task using a 3.0 T MRI scanner. The Barratt Impulsiveness Scale (BIS)-11 was used to assess impulsivity. RESULTS: There were no differences in the behavioral performance on the Go/No-Go task between the groups. However, the IGA group was significantly hyperactive during No-Go trials in the left superior medial frontal gyrus, right anterior cingulate cortex, right superior/middle frontal gyrus, left inferior parietal lobule, left precentral gyrus, and left precuneus and cuneus. Further, the bilateral middle temporal gyrus, bilateral inferior temporal gyrus, and right superior parietal lobule were significantly hypoactive during No-Go trials. Activation of the left superior medial frontal gyrus was positively associated with BIS-11 and Chen Internet Addiction Scale (CIAS) total score across IGA participants. CONCLUSIONS: Our data suggest that the prefrontal cortex may be involved in the circuit modulating impulsivity, while its impaired function may relate to high impulsivity in adolescents with IGA, which may contribute directly to the Internet addiction process.


Asunto(s)
Conducta Adictiva/fisiopatología , Conducta Impulsiva/fisiopatología , Personalidad/fisiología , Corteza Prefrontal/fisiopatología , Juegos de Video , Adolescente , Conducta Adictiva/psicología , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Conducta Impulsiva/psicología , Internet , Imagen por Resonancia Magnética , Masculino , Pruebas Neuropsicológicas , Encuestas y Cuestionarios , Adulto Joven
9.
J Vasc Interv Radiol ; 25(5): 739-46, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24745904

RESUMEN

PURPOSE: To prospectively determine the feasibility of flat-detector (FD) computed tomography (CT) perfusion to measure hepatic blood volume (BV) in the angiography suite in patients with hepatocellular carcinoma (HCC). MATERIALS AND METHODS: Twenty patients with HCC were investigated with conventional multislice and FD CT perfusion. CT perfusion was carried out on a multislice CT scanner, and FD CT perfusion was performed on a C-arm angiographic system, before transarterial chemoembolization procedures. BV values of conventional and FD CT perfusion were measured within tumors and liver parenchyma. The arterial perfusion portion of CT perfusion BV was extracted from CT perfusion BV by multiplying it by a hepatic perfusion index. Relative values (RVs) for CT perfusion arterial BV and FD CT perfusion BV (FD BV) were defined by dividing BV of tumor by BV of parenchyma. Relationships between BV and RV values of these two techniques were analyzed. RESULTS: In all patients, both perfusion procedures were technically successful, and all 33 HCCs larger than 10 mm were identified with both imaging methods. There were strong correlations between the absolute values of FD BV and CT perfusion arterial BV (tumor, r = 0.903; parenchyma, r = 0.920; both P < .001). Bland-Altman analysis showed a mean difference of -0.15 ± 0.24 between RVs for CT perfusion arterial BV and FD BV. CONCLUSIONS: The feasibility of FD CT perfusion to assess BV values of liver tumor and surrounding parenchyma in the angiographic suite was demonstrated.


Asunto(s)
Angiografía/métodos , Volumen Sanguíneo , Carcinoma Hepatocelular/fisiopatología , Neoplasias Hepáticas/fisiopatología , Neovascularización Patológica/fisiopatología , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Angiografía/instrumentación , Velocidad del Flujo Sanguíneo , Determinación del Volumen Sanguíneo/instrumentación , Determinación del Volumen Sanguíneo/métodos , Carcinoma Hepatocelular/diagnóstico por imagen , Estudios de Factibilidad , Femenino , Humanos , Circulación Hepática , Neoplasias Hepáticas/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Neovascularización Patológica/diagnóstico por imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/instrumentación , Adulto Joven
10.
Acad Radiol ; 21(4): 437-44, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24594413

RESUMEN

RATIONALE AND OBJECTIVES: To determine the potential value of entropy of T2-weighted imaging combined with apparent diffusion coefficient (ADC) before uterine artery embolization (UAE) for prediction of uterine leiomyoma volume reduction (VR) after UAE. MATERIALS AND METHODS: In this prospective study, 11 patients with uterine leiomyomas who underwent pelvic magnetic resonance imaging including diffusion-weighted imaging before and 6 months after UAE were included. A total number of 16 leiomyomas larger than 2 cm in diameter were evaluated. The volume of each leiomyoma before and after UAE was determined, and the percentage change in volume was calculated. Entropy of T2-weighted imaging and ADC before UAE were assessed. Pearson correction coefficients were calculated between leiomyoma VR after UAE and age, leiomyoma volume, ADC, and entropy, respectively. Multiple regression analysis was performed to investigate the parameters that determine the VR after UAE. Receiver operating characteristic curve analysis was used to determine the sensitivity and specificity of ADC, entropy and the combination of ADC and entropy for predicting volume response. RESULTS: The mean leiomyoma VR was 58.9% (range 25.8%-95.0%) in the 6-month follow-up. The mean ADC of leiomyomas was 1.37 × 10(-3) mm(2)/s (range 1.05 × 10(-3)-2.32 × 10(-3) mm(2)/s) and the mean entropy of T2-weighted imaging was 5.36 (range 4.62-5.91) before UAE. ADC and entropy were significantly correlated with leiomyoma VR, respectively (r = 0.61, P = .012; r = 0.73, P = .001). On multiple regression analysis, a combination of ADC and entropy constituted the best model for determining leiomyoma VR using Akaike information criterion. For predicting ≥50% VR, the optimal cutoff value of ADC was 1.39 × 10(-3) mm(2)/s (sensitivity 45.5%, specificity 80.0%) and the optimal cutoff value of entropy was 5.15 (sensitivity 90.9%, specificity 60.0%). The combination of ADC and entropy (area under the curve [AUC] 0.86) provided better classification accuracy than ADC or entropy alone (AUC 0.69 and 0.82, respectively). CONCLUSIONS: Pre-UAE entropy of T2-weighted imaging and ADC of leiomyomas were significantly correlated with the leiomyoma VR 6 months after embolization. Higher entropy and higher ADC may be related to greater leiomyoma VR after UAE. A combination of entropy and ADC may have predictive value for leiomyoma VR after UAE.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Interpretación de Imagen Asistida por Computador/métodos , Leiomioma/patología , Leiomioma/terapia , Embolización de la Arteria Uterina/métodos , Neoplasias Uterinas/patología , Neoplasias Uterinas/terapia , Adulto , Algoritmos , Entropía , Femenino , Humanos , Aumento de la Imagen/métodos , Persona de Mediana Edad , Imagen Multimodal/métodos , Pronóstico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento , Carga Tumoral
11.
Radiographics ; 33(5): 1419-33, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24025933

RESUMEN

A multilocular cystic hepatic lesion detected at computed tomography (CT) and magnetic resonance (MR) imaging is a common but nonspecific radiologic finding that can cause potential challenges for differential diagnosis. This imaging pattern may be observed in a wide spectrum of common and uncommon neoplastic or nonneoplastic entities. Neoplastic lesions include cystadenoma, cystadenocarcinoma, hepatocellular carcinoma (HCC), metastases, mesenchymal hamartoma, and inflammatory myofibroblastic tumor. Nonneoplastic lesions include hepatic abscess, echinococcal cyst, intrahepatic hematoma, and biloma. The multiple coalescent cysts seen in polycystic liver disease may exhibit an imaging pattern similar to that of a multilocular cystic lesion. Mural nodularity, irregular thickness of the septa, ragged inner surface, and typical enhancement pattern in the solid portion of the lesion are often indicative of malignancy, although multilocular primary or secondary malignant tumors are uncommon. Recognition of the more common necrosis or cystic change of HCC and metastases induced by locoregional or systemic treatment also is important. The nonenhanced cystic component may be composed of different types of fluids (eg, serous, mucinous, proteinaceous, hemorrhagic, bilious, or mixed) or spontaneous or treatment-related necrosis, whereas the septa may be formed by a wide range of tissues depending on the lesion type. An understanding of the CT and MR imaging findings of these lesions and their respective pathologic correlation aids in accurate diagnosis.


Asunto(s)
Quistes/diagnóstico , Hepatitis/diagnóstico , Hepatopatías/diagnóstico , Neoplasias Hepáticas/diagnóstico , Hígado/diagnóstico por imagen , Hígado/patología , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estadística como Asunto
12.
J Vasc Interv Radiol ; 24(5): 667-71, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23489772

RESUMEN

PURPOSE: To explore the significance of quantitative digital subtraction angiography (DSA; Q-DSA) in the assessment of chemoembolization endpoints. MATERIALS AND METHODS: Twenty patients with hepatocellular carcinoma treated with chemoembolization were included in the study. All DSA series before and after chemoembolization were postprocessed with Q-DSA. The maximal enhancement and time to peak (TTP) were measured for several homologous anatomic landmarks, including the origin and embolized site of the tumor-feeding artery, parenchyma of the tumor, and ostia of the pre- and postprocedure catheter. The TTP, tumor blood supply time, and maximal enhancement of the time density curve (TDC) were analyzed. RESULTS: Of the 20 DSA series collected, 18 were successfully postprocessed. The TTPs of the landmarks before and after treatment were 3.60 seconds±1.02 and 3.57 seconds±0.78 at the ostia of the catheter, 3.91 seconds±1.01 and 4.09 seconds±1.14 at the origin site of the tumor-feeding artery, and 4.07 seconds±1.02 and 5.60 seconds±1.56 s the embolized site of the main tumor-feeding artery, respectively. Statistical differences were detected between pre- and postprocedural TTP of the embolized site of the feeding artery (P<.01), as well as between pre- and postprocedural tumor blood supply time (P<.01). The mean maximal TDC enhancements of selected tumor spots were 3.01 units±1.04 and 0.81 units±0.35 before and after the procedure (P<.01), respectively. CONCLUSIONS: Q-DSA may provide a feasible quantitative measurement in the assessment of chemoembolization endpoints.


Asunto(s)
Angiografía de Substracción Digital/métodos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/terapia , Quimioembolización Terapéutica/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Mitomicina/administración & dosificación , Adulto , Anciano , Antibióticos Antineoplásicos/administración & dosificación , Determinación de Punto Final/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
13.
Eur Radiol ; 22(10): 2178-85, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22622347

RESUMEN

OBJECTIVES: To assess the feasibility and value of dual-energy spectral computed tomography (DESCT) imaging for differentiating neoplastic from bland macroscopic portal vein (PV) thrombi. METHODS: Computed tomography (CT) images of 44 patients with macroscopic PV thrombus (bland group, n = 16; neoplastic group, n = 28) were reviewed. Iodine-based material decomposition images in the portal venous phase were reconstructed to compare the iodine indices between groups, including thrombus iodine density (I (T)), thrombus-aorta iodine density ratio (I (T)/I (A)), and thrombus-PV iodine density ratio (I (T)/I (P)). Differential diagnostic performances of DESCT were calculated in the subgroup of 21 patients with histopathological evidence (bland group, n = 12; neoplastic group, n = 9). RESULTS: The iodine indices of the neoplastic group were significantly higher than those in the bland group (P < 0.001). A threshold I (T) of 1.14 mg/mL, I (T)/I (A) of 0.17, and I (T)/I (P) of 0.17 in the portal venous phase yielded 100 %, 88.9 %, and 100 % sensitivity, and 91.7 %, 91.7 %, and 83.3 % specificity, respectively, in differentiating neoplastic from bland PV thrombi. CONCLUSIONS: DESCT imaging with quantification of thrombus iodine density in the portal venous phase appears to be a promising new method for distinguishing neoplastic from bland macroscopic PV thrombi. KEY POINTS: • Differentiating the nature of portal vein thrombus is of great clinical significance. • Iodine-based material decomposition imaging reflects iodine distribution after contrast media administration. • Dual-energy CT with iodine quantification can distinguish bland from neoplastic PV thrombi.


Asunto(s)
Células Neoplásicas Circulantes , Vena Porta , Trombosis/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Diagnóstico Diferencial , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Tomografía Computarizada por Rayos X/métodos , Adulto Joven
14.
Hepatobiliary Pancreat Dis Int ; 11(1): 74-80, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22251473

RESUMEN

BACKGROUND: Portal hyperperfusion in the small-for-size (SFS) liver can threaten survival of rabbits. Therefore, it is important to understand the hemodynamic changes in the SFS liver. METHODS: Twenty rabbits were divided into two groups: a control group and a modulation group. The control group underwent an extended hepatectomy. The modulation group underwent the same procedure plus splenectomy to reduce portal blood flow. CT perfusion examinations were performed on all rabbits before and after operation. Perfusion parameter values, especially portal vein perfusion (PVP), were analyzed. RESULTS: PVP in the modulation group was lower than in the control group after operation (P=0.002). In the control group, postoperative PVP increased by 193.7+/-55.1% compared with preoperative PVP. A weak correlation was found between the increased percentage of PVP and resected liver-to-body weight ratio (RLBWR) (r=0.465, P=0.033). In the modulation group, postoperative PVP increased by 101.4+/-32.5%. No correlation was found between the increased percentage of PVP and RLBWR (r=0.167, P=0.644). Correlations were found between PVP and serum alanine aminotransferase, aspartate aminotransferase, and total bilirubin after surgery (P<0.05). CONCLUSION: We successfully evaluated the characteristics of hemodynamic changes as well as the effects of splenectomy in the SFS liver in rabbits by the CT technique.


Asunto(s)
Hemodinámica , Hepatectomía/efectos adversos , Circulación Hepática , Imagen de Perfusión/métodos , Vena Porta/diagnóstico por imagen , Vena Porta/fisiopatología , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/fisiopatología , Tomografía Computarizada por Rayos X , Alanina Transaminasa/sangre , Animales , Aspartato Aminotransferasas/sangre , Bilirrubina/sangre , Biomarcadores/sangre , Pruebas de Función Hepática , Masculino , Complicaciones Posoperatorias/sangre , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control , Conejos , Esplenectomía
15.
Abdom Imaging ; 35(5): 522-7, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19669829

RESUMEN

BACKGROUND: To identify hemodynamic alterations in anterior segment of liver graft after living-donor liver transplantation (LDLT) using CT perfusion imaging. METHODS: Perfusion images of 19 recipients 4 weeks after LDLT without reconstruction of the middle hepatic vein (MHV) tributaries were retrospectively identified. According to major MHV tributaries diameter in the right lobe graft, recipients were divided into large (≥ 5 mm) and small size groups (<5 mm). Blood flow (BF), blood volume (BV), and mean transit time (MTT) of anterior and posterior segments were calculated. RESULTS: In large size group, significantly decreased BF (66.98 ± 15.79 mL/min/100 g, corresponded to 37.08%), BV (8.27 ± 2.29 mL/100 g, 41.71%), and increased MTT (11.79 ± 2.10 s, 23.71%) were detected in the anterior segment compared to the posterior segment. In small size group, compared to the posterior segment, BF, BV in the anterior segment decreased 19.12%, 18.48%, respectively, and MTT increased 6.78%, where decreased BF (86.40 ± 21.39 mL/min/100 g) and BV (11.50 ± 2.59 mL/min/100 g) reached statistical significance. Perfusion imbalance in large size group was more remarkable than those in small size group. CONCLUSIONS: CT liver perfusion imaging enabled quantification of hemodynamic alterations in right-lobe liver graft after LDLT. Compared to small ones, ligation of large MHV tributaries could bring about more marked perfusion imbalance between anterior and posterior segments.


Asunto(s)
Trasplante de Hígado/métodos , Hígado/irrigación sanguínea , Hígado/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Análisis de Varianza , Velocidad del Flujo Sanguíneo , Volumen Sanguíneo , Estudios de Casos y Controles , Medios de Contraste/administración & dosificación , Femenino , Humanos , Yohexol/administración & dosificación , Yohexol/análogos & derivados , Hígado/cirugía , Donadores Vivos , Masculino , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador , Estudios Retrospectivos , Estadísticas no Paramétricas
16.
Clin Transplant ; 23(5): 692-9, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19473203

RESUMEN

Hepatic hemodynamic changes in grafts after living donor liver transplantation (LDLT) are complicated. In this study, computed tomography (CT) perfusion parameter values, especially portal vein perfusion (PVP), was retrospectively analyzed in recipients both with and without small-for-size syndrome (SFSS). PVP was significantly higher in non-SFSS recipients on post-operative day (POD) 14 or 28 than in normal donors before donation (p < 0.001 and p = 0.008, respectively), but it significantly decreased between 14 and 28 days post-operatively (p = 0.007). There was a significant inverse correlation between graft-to-recipient spleen size ratio and PVP on POD 14 in non-SFSS group (r = -0.545, p = 0.002). Furthermore, PVP in the SFSS group was significantly greater than in the non-SFSS group on POD 14 (p = 0.042). In conclusion, we successfully evaluated normal hemodynamic changes in grafts without SFSS by CT perfusion examination. To our knowledge, this is the first study on hemodynamic changes of living donor liver grafts using CT technique.


Asunto(s)
Trasplante de Hígado , Hígado/irrigación sanguínea , Hígado/diagnóstico por imagen , Donadores Vivos , Tomografía Computarizada por Rayos X , Adulto , Anciano , Ensayo de Inmunoadsorción Enzimática , Femenino , Supervivencia de Injerto , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Perfusión , Reacción en Cadena de la Polimerasa , Pronóstico , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
17.
J Neurol Sci ; 268(1-2): 60-4, 2008 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-18068726

RESUMEN

BACKGROUND: Studies were carried out to detect brain tissue damage in patients with vascular cognitive impairment (VCI) using diffusion tensor imaging (DTI) histogram analysis, and to determine the correlations between DTI histogram-derived measures and Mini-Mental State Examination (MMSE) scores. METHODS: Conventional MRI and DTI scans were performed on 19 patients with VCI, 19 age- and sex-matched post-stroke patients without cognitive impairment (stroke group) and 19 cognitively normal subjects (CN group). Histograms of the apparent diffusion coefficient (ADC) and fractional anisotropy (FA) of the whole brain were analyzed. RESULTS: Analysis showed that the patterns of the whole brain ADC and FA histograms of the VCI group differed from those of the stroke and CN groups. Compared with those of the two control groups, the mean FA value was significantly lower and the FA histogram peak height was higher in the VCI group. However, the patterns of the whole brain ADC and FA histograms in the stroke group were similar to those of the CN group, and there were no significant differences in any of the DTI histogram-derived measures between these two groups. The mean FA value, the FA histogram peak height, and the FA histogram peak location in VCI patients correlated with the MMSE scores. CONCLUSIONS: Our findings suggest that VCI leads to abnormal diffusion in brain tissue, and that DTI histogram-derived measures might be used to monitor the severity of cognitive impairment in this disease.


Asunto(s)
Mapeo Encefálico , Encéfalo/patología , Trastornos del Conocimiento/metabolismo , Trastornos del Conocimiento/patología , Imagen de Difusión por Resonancia Magnética/métodos , Anciano , Análisis de Varianza , Trastornos del Conocimiento/etiología , Femenino , Humanos , Masculino , Estudios Prospectivos , Estudios Retrospectivos , Enfermedades Vasculares/complicaciones , Enfermedades Vasculares/metabolismo , Enfermedades Vasculares/patología
18.
Zhongguo Yi Liao Qi Xie Za Zhi ; 30(4): 291-2, 260, 2006 Jul.
Artículo en Chino | MEDLINE | ID: mdl-17039942

RESUMEN

In order to evaluate the diagnostic value of the PACS, the PACS has been applied to Dept.of Radiology in Renji Hospital in Shanghai for nearly two and a half years. Clinical practice shows that the doctors can work more efficiently and accurately by using the diagnostic workstation of PACS. PACS is an inevitable development trend of image diagnosis and is playing a more and more important role in clinical applications.


Asunto(s)
Diagnóstico por Imagen/métodos , Sistemas de Información en Hospital , Sistemas de Información Radiológica , Sistemas de Administración de Bases de Datos , Hospitales Generales , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Almacenamiento y Recuperación de la Información/métodos , Servicio de Radiología en Hospital/organización & administración , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...