Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Neuroimage ; 270: 119940, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36787828

RESUMEN

Glutamate is the major excitatory transmitter in the brain and malfunction of the related metabolism is associated with various neurological diseases and disorders. The observation of labeling changes in the spectra after the administration of a 13C labelled tracer is a common tool to gain better insights into the function of the metabolic system. But so far, only a very few studies presenting the labeling effects in more than two voxels to show the spatial dependence of metabolism. In the present work, the labeling effects were measured in a transversal plane in the human brain using ultra-short TE and TR 1H FID-MRSI. The measurement set-up was most simple: The [1-13C]Glc was administered orally instead of intravenous and the spectra were measured with a pure 1H technique without the need of a 13C channel (as Boumezbeur et al. demonstrated in 2004). Thus, metabolic maps and enrichment curves could be obtained for more metabolites and in more voxels than ever before in human brain. Labeling changes could be observed in [4-13C]glutamate, [3-13C]glutamate+glutamine, [2-13C]glutamate+glutamine, [4-13C]glutamine, and [3-13C]aspartate with a high temporal (3.6 min) and spatial resolution (32 × 32 grid with nominal voxel size of 0.33 µL) in five volunteers.


Asunto(s)
Ácido Glutámico , Glutamina , Humanos , Glutamina/metabolismo , Isótopos de Carbono/metabolismo , Espectroscopía de Resonancia Magnética/métodos , Ácido Glutámico/metabolismo , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Administración Oral , Glucosa/metabolismo
2.
Magn Reson Med ; 89(1): 11-28, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36128885

RESUMEN

PURPOSE: This study analyzes the effects of retrospective lipid suppression, a simulated macromolecular prior knowledge and different spline baseline stiffness values on 9.4T multi-slice proton FID-MRSI data spanning the whole cerebrum of human brain and the reproducibility of respective metabolite ratio to total creatine (/tCr) maps for 10 brain metabolites. METHODS: Measurements were performed twice on 5 volunteers using a short TR and TE FID MRSI 2D sequence at 9.4T. The effects of retrospective lipid L2-regularization, macromolecular spectrum and different LCModel baseline flexibilities on SNR, FWHM, fitting residual, Cramér-Rao lower bound, and metabolite ratio maps were investigated. Intra-subject, inter-session coefficient of variation and the test-retest reproducibility of the mean metabolite ratios (/tCr) of each slice was calculated. RESULTS: Transversal, sagittal, and coronal slices of many metabolite ratio maps correspond to the anatomically expected concentration relations in gray and white matter for the majority of the cerebrum when using a flexible baseline in LCModel fit. Results from the second measurements of the same subjects show that slice positioning and data quality correlate significantly to the first measurement. L2-regularization provided effective suppression of lipid-artifacts, but should be avoided if no artifacts are detected. CONCLUSION: Reproducible concentration ratio maps (/tCr) for 4 metabolites (total choline, N-acetylaspartate, glutamate, and myoinositol) spanning the majority of the cerebrum and 6 metabolites (N-acetylaspartylglutamate, γ-aminobutyric acid, glutathione, taurine, glutamine, and aspartate) covering 32 mm in the upper part of the brain were acquired at 9.4T using multi-slice FID MRSI with retrospective lipid suppression, a macromolecular spectrum and a flexible LCModel baseline.


Asunto(s)
Encéfalo , Protones , Humanos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Sustancias Macromoleculares/metabolismo , Lípidos , Receptores de Antígenos de Linfocitos T/metabolismo
3.
Magn Reson Med ; 88(4): 1500-1515, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35657035

RESUMEN

PURPOSE: To further develop MultiNet GRAPPA, a neural-network-based reconstruction, for lower SNR proton MRSI (1 H MRSI) data using adapted undersampling schemes and improved training sets. METHODS: 1 H FID-MRSI data and an anatomical image for GRAPPA reconstruction were acquired in two slices in the human brain (n = 6) at 7T. MRSI data were retrospectively undersampled for a 4×, 6×, and 7× acceleration rate. Signal-to-noise, relative error (RE) between accelerated and fully sampled metabolic maps, RMS of the lipid artifacts, and fitting reliability were compared across acceleration rates, to the fully sampled data, and with different kinds and amounts of training images. RESULTS: Training with semi-synthetic images resulted in higher SNR and lower lipid RMS relative to training with acquired images from one or several subjects. SNR increased with the number of semi-synthetic training images and the 4× accelerated data retains ∼30% more SNR than other accelerated data. Spectra reconstructed with 20 semi-synthetic averages retained ∼100% more SNR and had ∼5% lower lipid RMS than those reconstructed with the center k-space points of one image as was originally proposed for very high SNR MRSI data and had higher fitting reliability. The metabolite RE was lowest when training with 20-semi-synthetic training images and highest when training with the center k-space points of one image. CONCLUSION: MultiNet GRAPPA is feasible with lower SNR 1 H MRSI data if 20-semi-synthetic training images are used at a 4× acceleration rate. This acceleration rate provided the best trade-off between scan time and spectral SNR.


Asunto(s)
Encéfalo , Protones , Algoritmos , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Calibración , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Lípidos , Imagen por Resonancia Magnética , Reproducibilidad de los Resultados , Estudios Retrospectivos , Relación Señal-Ruido
4.
J Cereb Blood Flow Metab ; 42(10): 1890-1904, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35632989

RESUMEN

For the first time, labeling effects after oral intake of [1-13C]glucose are observed in the human brain with pure 1H detection at 9.4 T. Spectral time series were acquired using a short-TE 1H MRS MC-semiLASER (Metabolite Cycling semi Localization by Adiabatic SElective Refocusing) sequence in two voxels of 5.4 mL in the frontal cortex and the occipital lobe. High-quality time-courses of [4-13C]glutamate, [4-13C]glutamine, [3-13C]glutamate + glutamine, [2-13C] glutamate+glutamine and [3-13C]aspartate for individual volunteers and additionally, group-averaged time-courses of labeled and non-labeled brain glucose could be obtained. Using a one-compartment model, mean metabolic rates were calculated for each voxel position: The mean rate of the TCA-cycle (Vtca) value was determined to be 1.36 and 0.93 µmol min-1 g-1, the mean rate of glutamine synthesis (Vgln) was calculated to be 0.23 and 0.45 µmol min-1 g-1, the mean exchange rate between cytosolic amino acids and mitochondrial Krebs cycle intermediates (Vx) rate was found to be 0.57 and 1.21 µmol min-1 g-1 for the occipital lobe and the frontal cortex, respectively. These values were in agreement with previously reported data. Altogether, it can be shown that this most simple technique combining oral administration of [1-13C]Glc with pure 1H MRS acquisition is suitable to measure metabolic rates.


Asunto(s)
Glucosa , Glutamina , Administración Oral , Aminoácidos , Ácido Aspártico/metabolismo , Encéfalo/metabolismo , Isótopos de Carbono/metabolismo , Lóbulo Frontal/diagnóstico por imagen , Lóbulo Frontal/metabolismo , Glucosa/metabolismo , Ácido Glutámico/metabolismo , Glutamina/metabolismo , Humanos , Espectroscopía de Resonancia Magnética/métodos , Lóbulo Occipital/diagnóstico por imagen , Lóbulo Occipital/metabolismo
5.
Neuroimage ; 244: 118639, 2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-34637905

RESUMEN

PURPOSE: To present first highly spatially resolved deuterium metabolic imaging (DMI) measurements of the human brain acquired with a dedicated coil design and a fast chemical shift imaging (CSI) sequence at an ultrahigh field strength of B0 = 9.4 T. 2H metabolic measurements with a temporal resolution of 10 min enabled the investigation of the glucose metabolism in healthy human subjects. METHODS: The study was performed with a double-tuned coil with 10 TxRx channels for 1H and 8TxRx/2Rx channels for 2H and an Ernst angle 3D CSI sequence with a nominal spatial resolution of 2.97 ml and a temporal resolution of 10 min. RESULTS: The metabolism of [6,6'-2H2]-labeled glucose due to the TCA cycle could be made visible in high resolution metabolite images of deuterated water, glucose and Glx over the entire human brain. CONCLUSION: X-nuclei MRSI as DMI can highly benefit from ultrahigh field strength enabling higher temporal and spatial resolutions.


Asunto(s)
Encéfalo/diagnóstico por imagen , Deuterio/metabolismo , Imagen por Resonancia Magnética/métodos , Glucosa/metabolismo , Sustancia Gris/diagnóstico por imagen , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...