1.
Appl Radiat Isot ; 163: 109216, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32561054

RESUMEN

Re-entrant ionization chambers (ICs) are essential to radionuclide metrology and nuclear medicine for maintaining standards and measuring half-lives. The requirements of top-level metrology demand that systems must be precise and stable to 0.1 % over many years, and linear from 10-14 A to 10-8 A. Thus, laboratories depend on bespoke current measurement systems and often rely on sealed sources to generate reference currents. To maintain and improve present capabilities, metrologists need to overcome two looming challenges: ageing electronics and decreasing availability of sealed sources. Possible solutions using Ultrastable Low-Noise Current Amplifiers (ULCAs), resistive-feedback electrometers, and (quantum) single-electron pumps are reviewed. Broader discussions of IC design and methodology are discussed. ULCAs show promise and resistive-feedback systems which take advantage of standard resistor calibrations offer an alternative.

2.
Br J Anaesth ; 120(5): 1110-1116, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29661388

RESUMEN

BACKGROUND: The role of obesity as a risk factor for difficult intubation remains controversial. We primarily assessed the association between body mass index (BMI) and difficult tracheal intubation. METHODS: We analysed electronic records of more than 67 000 adults having elective non-cardiac surgery requiring tracheal intubation at the Cleveland Clinic between 2011 and 2015. The association between BMI and difficult intubation, defined as more than one intubation attempt, was assessed using multivariable logistic regression adjusting for pre-specified confounders. RESULTS: Amongst 40 183 patients with BMI <30 kg m-2 and 27 519 with BMI ≥30 kg m-2, 9% required more than one intubation attempt. Increasing BMI up to 30 kg m-2 was significantly associated with increased odds of more than one intubation attempt [odds ratio (OR): 1.03; 97.5% confidence interval (CI): 1.02, 1.04] per unit increase in BMI, P < 0.001. However, the odds of difficult intubation remained unchanged once BMI exceeded 30 kg m-2 (P = 0.08). The results were similar when analysis was restricted to patients without history of airway abnormalities in whom intubation was attempted using a standard direct laryngoscope (OR: 1.03; 99.4% CI: 1.01, 1.04) per kg m-2 increase in BMI <30 kg m-2). CONCLUSIONS: Increasing BMI was associated with increasing odds of difficult intubation in the lean range. At higher BMI, the odds of difficult intubation remain elevated, but there is no additional increase in odds with further increase in BMI. Obese patients were thus harder to intubate than lean ones, but difficult intubation was no more likely in morbidly obese patients than in those who were only slightly obese.


Asunto(s)
Índice de Masa Corporal , Intubación Intratraqueal/estadística & datos numéricos , Obesidad/complicaciones , Adulto , Anciano , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
3.
Br J Anaesth ; 119(4): 803-811, 2017 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-29121296

RESUMEN

BACKGROUND: The anti-inflammatory effects of statins have been suggested to relieve postoperative pain. This retrospective study tested the association between the perioperative routine use of statins in therapeutic doses, and opioid requirements and pain scores, after hip replacement surgery. METHODS: With IRB approval, data was obtained for adult patients who had elective hip replacement surgery under spinal anaesthesia at Cleveland Clinic between 2005 and 2015. Patients were compared using a joint hypothesis framework. We used the inverse probability of treatment weighting method to control for observed confounding factors (a total of 26). RESULTS: We included 611 statin users and 780 non-statin users. Pain score during the initial 72 h after surgery was 0.07 higher (95% CI: -0.02, 0.17) in statin users (noninferiority test in both directions P<0.001). The estimated ratio of geometric means in the cumulative i.v. morphine equivalent opioid consumption was 1.01 (95% CI: 0.93, 1.10) for statin vs non-statin users (noninferiority test P=0.001 in the hypothesized direction and<0.001 in the other direction) during the initial 72 h after surgery. The statin and non-statin patients were deemed equivalent on postoperative opioid consumption and pain score. CONCLUSIONS: This is the first large retrospective clinical study that investigates the effects of statin use on postoperative pain and opioid consumption. We observed no difference between statin users and non-users during the initial 72 h after hip surgery. Our findings do not support the routine use of statins as part of an analgesic regimen.


Asunto(s)
Analgésicos Opioides/uso terapéutico , Anestesia Raquidea/métodos , Artroplastia de Reemplazo de Cadera , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Dolor Postoperatorio/tratamiento farmacológico , Atención Perioperativa/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/administración & dosificación , Masculino , Persona de Mediana Edad , Estudios Retrospectivos