Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Swiss Surg ; 9(5): 247-52, 2003.
Artículo en Alemán | MEDLINE | ID: mdl-14601329

RESUMEN

BACKGROUND: The Sorin Pericarbon Freedom Stentless aortic valve has the potential to provide superior hemodynamic function and durability. In this study we assessed the hemodynamic performance of this valve and its impact on LV-mass regression after aortic valve replacement. METHODS: 31 consecutive patients who received a Sorin Pericarbon Freedom Stentless aortic valve were analysed. Mean age of the patients (16 female and 15 male) was 64 +/- 17 years. Five patients had isolated aortic stenosis, three isolated aortic regurgitation and one combined aortic valve disease. Three patients had combined aortic and mitral valve disease, 14 patients concomitant coronary artery disease, one congenital aortic coarctation. Three patients had an acute aortic valve endocarditis. 18 patients were classified as high-risk patients (mean EuroSCORE 9 +/- 2). Mean left ventricular ejection fraction was 52.5 +/- 15.0%. RESULTS: Valve sizes from 21 mm to 29 mm were implanted. The valves were oversized by 2 mm compared to measurement. 16 patients received isolated aortic valve replacement, Three patients aortic valve replacement and mitral valve reconstruction. 12 patients had concomitant CABG. Three procedures were reoperations. Hospital mortality was 6.4% (two patients). Both deaths occurred in high-risk patients and were not valve-related. Four patients had perioperative low-output-syndrome and needed IABP. After six months a follow up echocardiography was performed. Mean and peak gradients were 9.6 +/- 4.4 and 20.6 +/- 5.9 mmHg, respectively. Significant reduction of left ventricular hypertrophy (LV mass index 126.5 +/- 27.3 vs. 189.6 +/- 45.3 g/m2, p = 0.0313) and improvement of the ejection fraction (58 +/- 9.8 vs. 52.5 +/- 15.0%, p = 0.9749) as compared with preoperative valve. CONCLUSIONS: The hemodynamic performance of the Sorin Pericarbon Freedom Stentless aortic valve is excellent and the patient outcome is satisfying. However the implantation technique requires longer ischemic time, the prosthesis offers very satisfying hemodynamic function and accelerates probably the LV-mass regression in the mid term follow-up. Late performance and durability of the valve have to be assessed.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Hemodinámica/fisiología , Complicaciones Posoperatorias/fisiopatología , Anciano , Anciano de 80 o más Años , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Comorbilidad , Endocarditis Bacteriana/mortalidad , Endocarditis Bacteriana/fisiopatología , Endocarditis Bacteriana/cirugía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/mortalidad , Diseño de Prótesis , Factores de Riesgo , Stents , Tasa de Supervivencia , Suiza , Remodelación Ventricular/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...