Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Opt Soc Am A Opt Image Sci Vis ; 40(8): 1612-1619, 2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37707118

RESUMEN

We discuss the effects of image scanning microscopy using doughnut beam illumination on the properties of signal strength and integrated intensity. Doughnut beam illumination can give better optical sectioning and background rejection than Airy disk illumination. The outer pixels of a detector array give a signal from defocused regions, so digital processing of these (e.g., by simple subtraction) can further improve optical sectioning and background rejection from a single in-focus scan.

2.
J Opt Soc Am A Opt Image Sci Vis ; 40(1): 138-148, 2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-36607082

RESUMEN

The properties of signal strength and integrated intensity in a scanned imaging system are reviewed. These properties are especially applied to confocal imaging systems, including image scanning microscopy. The integrated intensity, equal to the image of a uniform planar (sheet) object, rather than the peak of the point spread function, is a measure of the flux in an image. Analytic expressions are presented for the intensity in the detector plane for a uniform volume object, and for the resulting background. The variation in the integrated intensity with defocus for an offset point detector is presented. This axial fingerprint is independent of any pixel reassignment. The intensity in the detector plane is shown to contain the defocus information, and simple processing of the recorded data can improve optical sectioning and background rejection.


Asunto(s)
Microscopía Confocal , Microscopía Confocal/métodos
3.
Nat Commun ; 13(1): 7723, 2022 12 13.
Artículo en Inglés | MEDLINE | ID: mdl-36513680

RESUMEN

To date, the feasibility of super-resolution microscopy for imaging live and thick samples is still limited. Stimulated emission depletion (STED) microscopy requires high-intensity illumination to achieve sub-diffraction resolution, potentially introducing photodamage to live specimens. Moreover, the out-of-focus background may degrade the signal stemming from the focal plane. Here, we propose a new method to mitigate these limitations without drawbacks. First, we enhance a STED microscope with a detector array, enabling image scanning microscopy (ISM). Therefore, we implement STED-ISM, a method that exploits the working principle of ISM to reduce the depletion intensity and achieve a target resolution. Later, we develop Focus-ISM, a strategy to improve the optical sectioning and remove the background of any ISM-based imaging technique, with or without a STED beam. The proposed approach requires minimal architectural changes to a conventional microscope but provides substantial advantages for live and thick sample imaging.


Asunto(s)
Microscopía Fluorescente , Microscopía Fluorescente/métodos , Microscopía Confocal
4.
J Colloid Interface Sci ; 608(Pt 1): 622-633, 2022 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-34626997

RESUMEN

HYPOTHESIS: Polymeric anisotropic soft microparticles show interesting behavior in biological environments and hold promise for drug delivery and biomedical applications. However, self-assembly and substrate-based lithographic techniques are limited by low resolution, batch operation or specific particle geometry and deformability. Two-photon polymerization in microfluidic channels may offer the required resolution to continuously fabricate anisotropic micro-hydrogels in sub-10 µm size-range. EXPERIMENTS: Here, a pulsed laser source is used to perform two-photon polymerization under microfluidic flow of a poly(ethylene glycol) diacrylate (PEGDA) solution with the objective of realizing anisotropic micro-hydrogels carrying payloads of various nature, including small molecules and nanoparticles. The fabrication process is described via a reactive-convective-diffusion system of equations, whose solution under proper auxiliary conditions is used to corroborate the experimental observations and sample the configuration space. FINDINGS: By tuning the flow velocity, exposure time and pre-polymer composition, anisotropic PEGDA micro-hydrogels are obtained in the 1-10 µm size-range and exhibit an aspect ratio varying from 1 to 5. Furthermore, 200 nm curcumin-loaded poly(lactic-co-glycolic acid) (PLGA) nanoparticles and 100 nm ssRNA-encapsulating lipid nanoparticles were entrapped within square PEGDA micro-hydrogels. The proposed approach could support the fabrication of micro-hydrogels of well-defined morphology, stiffness, and surface properties for the sustained release of therapeutic agents.


Asunto(s)
Hidrogeles , Nanopartículas , Liposomas , Microfluídica , Polietilenglicoles
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...