Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Neuroimage ; 233: 117969, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33744453

RESUMEN

During continuous speech listening, brain activity tracks speech rhythmicity at frequencies matching with the repetition rate of phrases (0.2-1.5 Hz), words (2-4 Hz) and syllables (4-8 Hz). Here, we evaluated the applicability of wearable MEG based on optically-pumped magnetometers (OPMs) to measure such cortical tracking of speech (CTS). Measuring CTS with OPMs is a priori challenging given the complications associated with OPM measurements at frequencies below 4 Hz, due to increased intrinsic interference and head movement artifacts. Still, this represents an important development as OPM-MEG provides lifespan compliance and substantially improved spatial resolution compared with classical MEG. In this study, four healthy right-handed adults listened to continuous speech for 9 min. The radial component of the magnetic field was recorded simultaneously with 45-46 OPMs evenly covering the scalp surface and fixed to an additively manufactured helmet which fitted all 4 participants. We estimated CTS with reconstruction accuracy and coherence, and determined the number of dominant principal components (PCs) to remove from the data (as a preprocessing step) for optimal estimation. We also identified the dominant source of CTS using a minimum norm estimate. CTS estimated with reconstruction accuracy and coherence was significant in all 4 participants at phrasal and word rates, and in 3 participants (reconstruction accuracy) or 2 (coherence) at syllabic rate. Overall, close-to-optimal CTS estimation was obtained when the 3 (reconstruction accuracy) or 10 (coherence) first PCs were removed from the data. Importantly, values of reconstruction accuracy (~0.4 for 0.2-1.5-Hz CTS and ~0.1 for 2-8-Hz CTS) were remarkably close to those previously reported in classical MEG studies. Finally, source reconstruction localized the main sources of CTS to bilateral auditory cortices. In conclusion, t his study demonstrates that OPMs can be used for the purpose of CTS assessment. This finding opens new research avenues to unravel the neural network involved in CTS across the lifespan and potential alterations in, e.g., language developmental disorders. Data also suggest that OPMs are generally suitable for recording neural activity at frequencies below 4 Hz provided PCA is used as a preprocessing step; 0.2-1.5-Hz being the lowest frequency range successfully investigated here.


Asunto(s)
Estimulación Acústica/métodos , Corteza Auditiva/fisiología , Magnetoencefalografía/métodos , Percepción del Habla/fisiología , Habla/fisiología , Adulto , Corteza Auditiva/diagnóstico por imagen , Femenino , Humanos , Masculino , Adulto Joven
2.
Int J Comput Assist Radiol Surg ; 6(1): 83-92, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20495882

RESUMEN

PURPOSE: Electrophysiological mapping is effective in realizing a precise minimally invasive arrhythmia surgery. Recently, an epicardial electrophysiological mapping system for minimally invasive arrhythmia surgery was reported. The system requires a small electrode array, a tracking system and a global mapping algorithm. The optical tracking system employed in the research requires line of sight and complicated configuration. This paper proposes a new tracking method for locating an electrode array. METHODS: We developed a small electrode array and optical markers. Center points of respective optical markers and the electrode array are tracked via an endoscopic stream and calculated in image space. The orientation of the electrode array is calculated using the dot product between the vector joining two center points of two upper optical markers and the vector joining two end points of the longest edge of the electrode array. RESULTS: Mean tracking errors of position and orientation of the electrode array were 0.51 mm and 0.64°, respectively. And the processing time was constant at 46 ms per frame. Our method could successfully track the electrode array on the epicardium during in vivo experiment and a global epicardial electrophysiological map was reconstructed from separately measured epicardial electrograms by the small electrode array. CONCLUSIONS: An image-based tracking method for locating an electrode array was proposed. Tracking accuracy, processing time and applicability to surgical environment of our method proved to be acceptable. Consequently, our method enables the electrode array tracking system to be simplified with no separate tracking system.


Asunto(s)
Arritmias Cardíacas/fisiopatología , Procedimientos Quirúrgicos Cardíacos/métodos , Electrodos , Mapeo Epicárdico/instrumentación , Interpretación de Imagen Asistida por Computador/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos , Animales , Arritmias Cardíacas/cirugía , Modelos Animales de Enfermedad , Reproducibilidad de los Resultados , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...