RESUMEN
BACKGROUND: Sequential synchronized atrioventricular (AV) pacing provides enhanced electrophysiologic parameters which contribute to improved hemodynamic parameters and increased cardiac performance to subsequently confer a clinical advantage over traditional ventricular pacing. Current temporary transvenous pacemaker catheters are limited to only one electrode which paces solely the right ventricle, thus lacking the capability to provide the optimal pacing mode. A new multilead pacemaker device was developed in response to the need for improved temporary pacing through the utilization of sequential synchronized atrioventricular pacing (TAVSP). It consists of seven preformed, preshaped nitinol wires electrodes, of which four are for intra-atrial and three for intraventricular positioning and endocardial contact, respectively. Each wire carries a ball tip designed to minimize tissue trauma and provide a high current density for adequate myocardial capture. The device is not yet Food and Drug Administration approved. OBJECTIVE: To present the unique structural components and mechanical properties of a novel sequential synchronized AV pacing device for temporary insertion and to report its first-in-human application with an analysis of the early clinical experience. METHODS: Following a process of development and proof of concept of the novel pacing modality in an animal model which demonstrated feasibility and safety, a series of patients who were candidates for the device application was identified. During left and right heart catheterization, the novel temporary pacing catheter was inserted transvenously and delivered in most patients under fluoroscopy or echocardiography. The catheter was deployed to its target right heart anatomic sites and then activated in an AV sequential mode. The technical aspects, the corresponding clinical utilization, and device performance were documented and analyzed. RESULTS: The series included 10 enrolled subjects. During planned left and right heart catheterization, the novel TAVSP device was inserted transvenously and then delivered and deployed successfully in a timely fashion in all patients. The pacing catheter achieved proper threshold and impedance in all (100%) patients. The performance of all ventricular leads was adequate; however, in 1 (10%) patient poor performance of the atrial leads was detected. The device was successfully retrieved in all patients. No adverse arrhythmia, impaired hemodynamics, or clinical adverse events occurred. No technical difficulties, component failure, or wires thrombosis were detected. All patients sustained the device application without sequala and were discharged home. CONCLUSION: Initial clinical experience with the utilization of a novel TAVSP demonstrates feasibility and safety in humans. The TAVSP modality potentially offers improved pacing capability and subsequent hemodynamic benefits over the current temporary pacing catheters. Further experience with the clinical application of this pacing catheter is warranted.
Asunto(s)
Estimulación Cardíaca Artificial , Marcapaso Artificial , Animales , Arritmias Cardíacas/terapia , Catéteres , Ventrículos Cardíacos , HumanosRESUMEN
The COVID-19 pandemic has had far-reaching consequences beyond the disease itself, including economic, social, political, religious, and psychological implications. This novel coronavirus has been shown to have cardiovascular manifestations in the form of arrhythmias, conduction disturbances, myocarditis, stress cardiomyopathy, myocardial injury and myocardial ischemia or infarction from increased microvascular and/or macrovascular coagulopathy. However, in addition to these direct effects, we are now starting to recognize indirect cardiovascular effects of COVID-19 in the form of increased incidence of Takutsobo cardiomyopathy in patients without any evidence of coronavirus infection presumably due to the increased psychological stress of social isolation and societal turbulence. In this case series, we present two post-menopausal women, presenting with chest pain and acute coronary syndrome, who are finally diagnosed with stress cardiomyopathy, triggered by increased emotional stress-related to the pandemic. There is data from a retrospective cohort analysis showing a fourfold increase in the incidence of acute coronary syndrome resulting from stress cardiomyopathy during the pandemic period compared to similar times periods before the pandemic. Hence, health care providers need to be cognizant of the emotional ramifications of the ongoing pandemic in the form of increased risk of Takotsubo cardiomyopathy. Moreover, urgent measures need to be taken to help the at-risk population cope with the ongoing stressors to help decrease the incidence of this cardiomyopathy.
Asunto(s)
COVID-19/complicaciones , Electrocardiografía , Distrés Psicológico , Estrés Psicológico/complicaciones , Cardiomiopatía de Takotsubo/etiología , Anciano , Anciano de 80 o más Años , COVID-19/epidemiología , Femenino , Humanos , Pandemias , SARS-CoV-2 , Estrés Psicológico/psicología , Cardiomiopatía de Takotsubo/diagnóstico , Cardiomiopatía de Takotsubo/psicologíaAsunto(s)
COVID-19/terapia , Síndrome de Dificultad Respiratoria/terapia , Síndrome de Dificultad Respiratoria/virología , Células Madre Adultas/trasplante , Enzima Convertidora de Angiotensina 2/uso terapéutico , Azitromicina/uso terapéutico , Transfusión de Componentes Sanguíneos , COVID-19/complicaciones , Oxigenación por Membrana Extracorpórea/métodos , Humanos , Hidroxicloroquina/uso terapéutico , Ivermectina/uso terapéutico , Plasma , Proteínas Recombinantes/uso terapéutico , SARS-CoV-2RESUMEN
BACKGROUND AND AIM OF STUDY: The treatment of inoperable patients with concomitant complex coronary artery disease and severe aortic stenosis unsuitable for conventional transcatheter aortic valve replacement (TAVR) poses a significant challenge. Effective treatment is even more difficult in those patients with complex coronary anatomy unamenable to percutaneous revascularization. Our manuscript aims to enlighten clinicians on the management of this complex patient. METHODS: We conducted a contemporary review of the literature of combined off-pump coronary artery bypass grafting and transaortic TAVR in this patient population and describe our own successful experience in an inoperable patient with a porcelain aorta. RESULTS: Including our report, 17 cases have been described in the literature. All patients had multiple comorbidities with elevated STS (range, 2.6-25; 6%) and EuroScore I (range, 13.7-83; 7%) and were not considered candidates for conventional CABG and SAVR. Most had severe, complex, multivessel CAD deemed unsuitable for PCI and structural findings precluding them from other standard percutaneous or alternative TAVR approaches (transfemoral/subclavian/transcaval/transapical). Out of the 17 cases, 5 (29%) had porcelain aortas. Most reports specify the decision-making process is driven by a multidisciplinary team. CONCLUSION: This report demonstrates that hybrid off-pump CABG surgery and transaortic TAVR can be successfully performed in high-risk patients with porcelain aortas who are not candidates for percutaneous methods, on-pump revascularization, transfemoral, subclavian, or transcaval valve implantations. It also highlights that careful study of the CTA scan could predict adequate access for a transaortic approach even in the presence of porcelain aorta in selected patients.
Asunto(s)
Variación Anatómica , Estenosis de la Válvula Aórtica/cirugía , Puente de Arteria Coronaria Off-Pump/métodos , Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/anatomía & histología , Arteria Femoral/patología , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Aorta Abdominal/patología , Calcinosis , Humanos , Masculino , Intervención Coronaria Percutánea/métodos , Riesgo , Índice de Severidad de la EnfermedadRESUMEN
Although fractured coronary wires are a rare occurrence, failure to retrieve them successfully puts patients at undue risk. We offer a technique that can be used when traditional retrieval with a Microsnare system is unsuccessful.
Asunto(s)
Enfermedad Coronaria/cirugía , Remoción de Dispositivos/métodos , Arterias Mamarias , Intervención Coronaria Percutánea , Anciano de 80 o más Años , Angiografía Coronaria/métodos , Enfermedad Coronaria/diagnóstico , Enfermedad Coronaria/fisiopatología , Falla de Equipo , Humanos , Masculino , Arterias Mamarias/diagnóstico por imagen , Arterias Mamarias/patología , Arterias Mamarias/cirugía , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/métodosRESUMEN
OBJECTIVE: Evaluate the use of mechanical circulatory support (MCS) devices in high-risk patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: The use of MCS devices in elderly patients with multiple comorbidities undergoing TAVR is underexplored. METHODS: All patients undergoing TAVR at a single tertiary academic center who required MCS during index procedure between 2008 and 2015 were included in a prospective database. RESULTS: MCS was used in 9.4% (54/577) of all TAVRs (n = 52 Edwards Sapien and n = 2 CoreValves) of which 68.5% (n = 37) were used as part of a planned strategy, and 31.5% (n = 17) were used in emergency "bail-out" situations. IABP was the most commonly used device (87%) followed by Impella and ECMO (6% each). Among the MCS group, 22% required cardiopulmonary resuscitation during the procedure (n = 4 elective [11%] vs. n = 8 emergent [47%]) and 15% upgrade to a second device (Impella or CPB after IABP; n = 5 elective [14%] vs. n = 3 emergent [18%]). Median duration of support was 1-day. Device related complications were low (4%). In-hospital mortality in this extremely high-risk population was 24% (13/54) (11% [4/37] for elective cases and 53% [9/17] for emergency cases). Cardiogenic shock (50%) was the most common cause of in-hospital death. Cumulative all-cause 1-year mortality was 35% (19/54) (19% 97/370 for elective and 71% [12/17] for emergency cases). CONCLUSION: Emergent use of MCS during TAVR in extremely high-risk population is associated with high short and long-term mortality rates. Early identification of patients at risk for hemodynamic compromise may rationalize elective utilization of MCS during TAVR.
Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Circulación Asistida , Puente Cardiopulmonar , Procedimientos Quirúrgicos Electivos/estadística & datos numéricos , Servicios Médicos de Urgencia/estadística & datos numéricos , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Circulación Asistida/instrumentación , Circulación Asistida/métodos , Circulación Asistida/mortalidad , Puente Cardiopulmonar/instrumentación , Puente Cardiopulmonar/métodos , Puente Cardiopulmonar/mortalidad , Procedimientos Quirúrgicos Electivos/métodos , Servicios Médicos de Urgencia/métodos , Femenino , Mortalidad Hospitalaria , Humanos , Masculino , Evaluación de Procesos y Resultados en Atención de Salud , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Análisis de Supervivencia , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estados Unidos/epidemiologíaRESUMEN
Cumulative evidence suggests that lipoprotein(a) [Lp(a)] exerts an independent effect on the initiation and progression of atherosclerotic cardiovascular disease. The genetically mediated expression of apolipoprotein(a), which is the key structural and functional component of Lp(a), occurs in hepatocytes with subsequent extracellular Lp(a) assembly at the hepatic cell surface. Here, we describe a case of elevated Lp(a) concentrations identified after (and likely acquired by) orthotopic liver transplantation that contributed to accelerated atherosclerotic cardiovascular disease despite intensive therapeutic interventions. This case study represents an important example to include Lp(a) screening in routine lipid panel testing for all liver transplant donors and recipients; to reduce unanticipated and debilitating cardiovascular morbidity and mortality.
Asunto(s)
Aterosclerosis/sangre , Progresión de la Enfermedad , Lipoproteína(a)/sangre , Trasplante de Hígado/efectos adversos , Aterosclerosis/patología , Humanos , Masculino , Persona de Mediana Edad , RecurrenciaRESUMEN
Transcatheter aortic valve implantation for aortic stenosis has evolved as an alternative treatment for patients who are at high or excessive surgical risk. We report the case of an 84-year-old man with a degenerated surgically implanted valve in a subaortic position (9 mm below the native annulus) who underwent "valve-in-valve" transcatheter aortic valve implantation with use of a Medtronic CoreValve system. We planned to deploy the CoreValve at a conventional depth in the left ventricular outflow tract; we realized that this might result in paravalvular regurgitation, but it would also afford a "deep" landing site for a second valve, if necessary. Ultimately, we implanted a second CoreValve deep in the left ventricular outflow tract to seal a paravalvular leak. The frame of the first valve--positioned at the conventional depth--enabled secure anchoring of the second valve in a deeper position, which in turn effected successful treatment of the failing subaortic surgical prosthesis without paravalvular regurgitation.
Asunto(s)
Insuficiencia de la Válvula Aórtica/terapia , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis , Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Falla de Prótesis , Anciano de 80 o más Años , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/etiología , Ecocardiografía Transesofágica , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Tomografía Computarizada Multidetector , Diseño de Prótesis , Radiografía Intervencional , Resultado del TratamientoRESUMEN
At our institutions, increasing numbers of aortic stenosis patients were not candidates for surgical aortic valve replacement. Accordingly, we initiated the Cali Colombian Transcatheter Aortic Valve Implantation (TAVI) program. From March 2008 through January 2011, 53 consecutive patients (mean age, 79 ± 6 yr; men, 58%) underwent TAVI with the Medtronic CoreValve System, and data were prospectively collected. Our study's endpoints conformed with Valve Academic Research Consortium recommendations. We report our clinical results.Predicted mortality rates were 25% (interquartile range, 17%-34%) according to logistic EuroSCORE and 6% (interquartile range, 3%-8%) according to the Society of Thoracic Surgeons score. The 30-day mortality rate was 9% (3 intraprocedural deaths, 5 total). The combined 30-day safety endpoint was 30% (major vascular sequelae, 23%; life-threatening bleeding, 12%; myocardial infarction, 4%; major stroke, 4%; and acute kidney injury [stage 3], 2%). Eight patients (15%) required post-implantation balloon dilation and 2 (4%) required valve-in-valve implantation, for a technical device success rate of 77%. Mean peak transvalvular gradient decreased from 74 ± 29 to 17 ± 8 mmHg and mean transvalvular gradient from 40 ± 17 to 8 ± 4 mmHg (both P=0.001). Moderate or severe aortic regurgitation decreased from 32% to 18% (P=0.12) and mitral regurgitation from 32% to 13% (P=0.002). The 1-year survival rate was 81%.We found that TAVI with the CoreValve prosthesis was safe and feasible, with sustained long-term results, for treating aortic stenosis in patients at excessive surgical risk; nonetheless, serious adverse events occurred in 30% of the patients.