Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Eur J Ophthalmol ; 31(2): NP33-NP38, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32141311

RESUMEN

INTRODUCTION: Mooren's ulcer is a painful, inflammatory chronic keratitis that affects corneal periphery, progressing centripetally, ultimately ending in perforation. The first line of treatment includes systemic immunomodulators, with surgery being the last option. We present a case of bilateral Boston keratoprosthesis implantation for severe Mooren's ulcer that responded differently in each eye. CLINICAL CASE: A 32-year-old male with corneal opacification, anterior staphylomas, vision of hand movement, was started on systemic immunosuppression with cyclosporine. After two failed penetrating keratoplasties in each eye, high intraocular pressure despite diode cyclophotocoagulation, and cystic macular edema, we performed Boston keratoprosthesis type 1 in both eyes. The right eye responded initially well, with a best-corrected visual acuity of 20/80 and normal intraocular pressure. The left eye presented high intraocular pressure, which required cyclophotocoagulation, ultimately resulting in hypotony. Boston keratoprosthesis was performed but had peripheral corneal necrosis that progressed despite amniotic membrane transplantation and aggressive intensive treatment with medroxyprogesterone, autologous platelet-rich-in-growth-factors eye drops, and oral doxycycline. Thus, replacement of the semi-exposed Boston keratoprosthesis with tectonic penetrating keratoplasty was necessary. However, both eyes developed phthisis bulbi with final visual acuity of perception of light with poor localization. CONCLUSION: Mainstay treatment of Mooren's ulcer is systemic immunomodulation. Surgical treatment must be considered only when risk of perforation, preferably with inflammation under control. Penetrating keratoplasty frequently fails, and Boston keratoprosthesis may be a viable option. However, postoperative complications, especially uncontrolled high intraocular pressure, corneal necrosis, and recurrence of Mooren's ulcer may jeopardize the outcomes and need to be addressed promptly with intensive topical and systemic treatment.


Asunto(s)
Órganos Artificiales , Córnea , Úlcera de la Córnea/cirugía , Prótesis e Implantes , Adulto , Antibacterianos/uso terapéutico , Terapia Combinada , Anticonceptivos Hormonales Orales/uso terapéutico , Doxiciclina/uso terapéutico , Estudios de Seguimiento , Humanos , Queratoplastia Penetrante , Masculino , Medroxiprogesterona/uso terapéutico , Soluciones Oftálmicas/uso terapéutico , Plasma Rico en Plaquetas/fisiología , Recurrencia , Úlcera , Agudeza Visual
2.
Curr Eye Res ; 45(12): 1497-1503, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32578462

RESUMEN

PURPOSE: To investigate the feasibility of using Optisol-GS as a convenient, xenogeneic-free alternative for storage of cultured human limbal epithelial cells (HLECS) for use in treatment of limbal stem cell deficiency (LSCD). In the present study, we compared storage of cultured HLEC using the conventional hypothermic Optisol-GS storage method at 4°C versus storage at 23°C (room temperature). MATERIALS AND METHODS: HLECs were cultured for three weeks on amniotic membrane (AM), transferred to polypropylene containers and stored in Optisol-GS for 4 days at 23°C and 4°C. A calcein-acetoxymethyl ester/ethidium homodimer-1 assay was used to assess viability. Morphology and phenotype were analyzed by light microscopy and immunohistochemistry, respectively. RESULTS: Expression of stem cell and proliferation markers p63, ∆Np63α, ABCG2, K19, K3, Cx43, Ki67, and PCNA was maintained at pre-storage control levels during storage at 23°C. ABCG2 and PCNA expression were both significantly altered during storage at 4°C. HLEC cell sheet viability also significantly declined following storage at 4°C. HLEC sheets stored at 4°C demonstrated extensive detachment of basal cells from the AM in sharp contrast to storage at 23°C, where attachment to the AM was maintained throughout the storage period. CONCLUSIONS: The present study demonstrates the feasibility of short-term storage of cultured HLECs in Optisol-GS, which offers a convenient standardized xenogeneic-free storage method. Storage temperature highly affected the results. Maintenance of cell viability, morphology and undifferentiated proliferative phenotype of cultured HLEC sheets favored storage at 23°C.


Asunto(s)
Sulfatos de Condroitina , Criopreservación , Dextranos , Células Epiteliales/citología , Gentamicinas , Limbo de la Córnea/citología , Preservación de Órganos/métodos , Temperatura , Biomarcadores/metabolismo , Supervivencia Celular/fisiología , Células Cultivadas , Mezclas Complejas , Medio de Cultivo Libre de Suero , Células Epiteliales/metabolismo , Estudios de Factibilidad , Humanos , Inmunohistoquímica , Fenotipo
4.
Cornea ; 31(9): 1000-8, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22475641

RESUMEN

PURPOSE: To evaluate the efficacy of commonly used biomarkers in dry eye disease management in a longitudinal observational case series study followed by an interventional study in a subset of subjects treated with cyclosporine A (0.05%). METHODS: Bilateral tear osmolarity, Schirmer, tear film breakup time (TBUT), staining, meibomian grading, and Ocular Surface Disease Index were measured for a period of 3 consecutive months in participants recruited from a clinic-based population at 2 study sites. Fifty-two subjects completed the study (n = 16 mild/moderate, n = 36 severe; age, 47.1 ± 16.1 years). After the 3-month observation period, severe dry eye patients were prescribed topical cyclosporine A and evaluated for an additional 3 months. RESULTS: Tear osmolarity (8.7 ± 6.3%) exhibited significantly less variability over a 3-month period than corneal staining (12.2 ± 8.8%, P = 0.040), conjunctival staining (14.8 ± 8.9%, P = 0.002), and meibomian grading (14.3 ± 8.8%, P < 0.0001) across the entire patient population. Osmolarity also demonstrated less variation than TBUT (11.7 ± 9.0%, P = 0.059), Schirmer tests (10.7 ± 9.2%, P = 0.67), and Ocular Surface Disease Index (9.3 ± 7.8%, P = 0.94), although the differences were not significant. Variation in osmolarity was less for mild dry eye patients (5.9 ± 3.1%) than severe dry eye patients (10.0 ± 6.9%, P = 0.038). After treatment, average osmolarity and variability were lowered from 341 ± 18 mOsm/L to 307 ± 8 mOsm/L (P < 0.0001, n = 10). A downward trend in symptoms followed changes in osmolarity, declining from 44 ± 17 mOsm/L to 38 ± 18 mOsm/L (P = 0.35). None of the other signs demonstrated a change after treatment. CONCLUSIONS: Over a 3-month period, tear film osmolarity was found to have the lowest variability among commonly used signs of dry eye disease. Reductions in osmolarity preceded changes in symptoms during therapy.


Asunto(s)
Ciclosporina/uso terapéutico , Técnicas de Diagnóstico Oftalmológico , Síndromes de Ojo Seco/diagnóstico , Síndromes de Ojo Seco/tratamiento farmacológico , Inmunosupresores/uso terapéutico , Lágrimas/química , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores , Ensayos Clínicos como Asunto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Concentración Osmolar , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
5.
Acta Ophthalmol ; 90(6): 519-25, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21595859

RESUMEN

PURPOSE: To determine the value of electroretinography (ERG) and visual evoked potential (VEP) in predicting visual outcome in patients undergoing osteo-keratoprosthesis (OKP) or osteo-odonto-keratoprosthesis (OOKP) surgery. METHODS: We performed a retrospective cohort study of 143 eyes in 101 patients who underwent OKP or OOKP surgery. The subjects underwent ERG, VEP testing or both up to 6 months prior to surgery. The ERG and VEP results were classified into four categories based on wave amplitude, latency and configuration. The main outcome was the maximum best-corrected visual acuity (maxBCVA) reached at any time postoperatively. RESULTS: One hundred thirty-four cases had undergone preoperative ERG, 82 VEP and 73 both examinations. The sensitivities of ERG and VEP to detect maxBCVA≥0.05 were 68.5% and 87%, respectively, while the specificity was 63.2% for ERG and 47.4% for VEP. The maxBCVA was significantly better in patients with normal ERG (p=0.033) and those with normal VEP (p=0.048), once having defined appropriate normal and abnormal cut-off levels. When comparing fellow eyes in patients who underwent surgery in both eyes, maxBCVA was better in the eyes that had better VEP results (p=0.013). CONCLUSION: Eyes demonstrating normal ERG or VEP achieved better visual outcome than those with abnormal results. In addition, VEP proved instrumental in determining the eye with the best prognosis when comparing both eyes of a given patient.


Asunto(s)
Órganos Artificiales , Córnea , Enfermedades de la Córnea/cirugía , Electrorretinografía , Potenciales Evocados Visuales/fisiología , Prótesis e Implantes , Agudeza Visual/fisiología , Adulto , Femenino , Humanos , Masculino , Periodo Preoperatorio , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA