1.
BMJ Case Rep ; 12(9)2019 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-31511269

RESUMEN

A 2.5-year-old boy with a history of (transient) congenital hyperinsulinism was admitted to the paediatric ward with recurrent hypoglycaemia. Diazoxide 5 mg/kg/day and hydrochlorothiazide 2 mg/kg/day were initiated. After increasing the dose of diazoxide to 10 mg/kg/day, the child developed mild rectal bleeding, petechiae, epistaxis and haematemesis. Blood screening showed severe thrombocytopaenia. Diazoxide and hydrochlorothiazide were stopped, and his platelet count normalised. Drug rechallenge was positive. Drug-induced immune thrombocytopaenia was diagnosed.


Asunto(s)
Antihipertensivos/efectos adversos , Diazóxido/efectos adversos , Hidroclorotiazida/efectos adversos , Trombocitopenia/inducido químicamente , Preescolar , Quimioterapia Combinada/efectos adversos , Epistaxis/inducido químicamente , Hematemesis/inducido químicamente , Humanos , Hiperinsulinismo/congénito , Hiperinsulinismo/tratamiento farmacológico , Masculino , Enfermedades del Recto/inducido químicamente
2.
J Clin Monit Comput ; 32(3): 457-464, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28861669

RESUMEN

The aim was to assess the reproducibility of the Pleth Variability Index (PVI), developed for non-invasive monitoring of peripheral perfusion, in preterm neonates below 32 weeks of gestational age. Three PVI measurements were consecutively performed in stable, comfortable preterm neonates in the first 48 h of life. On each occasion, pulse oximeter sensors were attached to two different limbs for 5 min. Reproducibility was assessed with the intra-class correlation coefficient (ICC) and Bland-Altman analysis. A total of 25 preterm neonates were included. Inter-limb comparison showed fair to moderate ICC's with 95%-confidence intervals (95%-CI). Left hand-right hand ICC = 0.498, 95%-CI (0.119-0.753); right foot-right hand ICC = 0.314 (-0.088-0.644); right foot-left foot ICC = 0.315 (-0.089-0.628). Intra-limb comparison showed fair to moderate ICC for right foot-right foot ICC = 0.380 (-0.014-0.677); and good ICC for right hand-right hand ICC = 0.646 (0.194-0.852). Bland-Altman plots showed moderate reproducibility of measurements between different limbs and of the same limb in consecutive time periods, with large biases and wide limits of agreement. The findings from this study indicate that PVI measurement is poorly reproducible when measured on different limbs and on the same limb in stable and comfortable preterm neonates.


Asunto(s)
Oximetría/métodos , Oximetría/normas , Presión Sanguínea , Extremidades/patología , Femenino , Edad Gestacional , Humanos , Recién Nacido , Recien Nacido Prematuro , Cuidado Intensivo Neonatal/normas , Masculino , Reproducibilidad de los Resultados