Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38329507

RESUMEN

PURPOSE: The aim of this study was to investigate the biodistribution of (super-)selective trans-arterial radioembolization (TARE) with holmium-166 microspheres (166Ho-MS), when administered as adjuvant therapy after RFA of HCC 2-5 cm. The objective was to establish a treatment volume absorbed dose that results in an absorbed dose of ≥ 120 Gy on the hyperemic zone around the ablation necrosis (i.e., target volume). METHODS: In this multicenter, prospective dose-escalation study in BCLC early stage HCC patients with lesions 2-5 cm, RFA was followed by (super-)selective infusion of 166Ho-MS on day 5-10 after RFA. Dose distribution within the treatment volume was based on SPECT-CT. Cohorts of up to 10 patients were treated with an incremental dose (60 Gy, 90 Gy, 120 Gy) of 166Ho-MS to the treatment volume. The primary endpoint was to obtain a target volume dose of ≥ 120 Gy in 9/10 patients within a cohort. RESULTS: Twelve patients were treated (male 10; median age, 66.5 years (IQR, [64.3-71.7])) with a median tumor diameter of 2.7 cm (IQR, [2.1-4.0]). At a treatment volume absorbed dose of 90 Gy, the primary endpoint was met with a median absorbed target volume dose of 138 Gy (IQR, [127-145]). No local recurrences were found within 1-year follow-up. CONCLUSION: Adjuvant (super-)selective infusion of 166Ho-MS after RFA for the treatment of HCC can be administered safely at a dose of 90 Gy to the treatment volume while reaching a dose of ≥ 120 Gy to the target volume and may be a favorable adjuvant therapy for HCC lesions 2-5 cm. TRIAL REGISTRATION: Clinicaltrials.gov NCT03437382 . (registered: 19-02-2018).

2.
Lancet Oncol ; 25(1): 137-146, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38081200

RESUMEN

BACKGROUND: Guidelines are inconclusive on whether contrast-enhanced MRI using gadoxetic acid and diffusion-weighted imaging should be added routinely to CT in the investigation of patients with colorectal liver metastases who are scheduled for curative liver resection or thermal ablation, or both. Although contrast-enhanced MRI is reportedly superior than contrast-enhanced CT in the detection and characterisation of colorectal liver metastases, its effect on clinical patient management is unknown. We aimed to assess the clinical effect of an additional liver contrast-enhanced MRI on local treatment plan in patients with colorectal liver metastases amenable to local treatment, based on contrast-enhanced CT. METHODS: We did an international, multicentre, prospective, incremental diagnostic accuracy trial in 14 liver surgery centres in the Netherlands, Belgium, Norway, and Italy. Participants were aged 18 years or older with histological proof of colorectal cancer, a WHO performance status score of 0-4, and primary or recurrent colorectal liver metastases, who were scheduled for local therapy based on contrast-enhanced CT. All patients had contrast-enhanced CT and liver contrast-enhanced MRI including diffusion-weighted imaging and gadoxetic acid as a contrast agent before undergoing local therapy. The primary outcome was change in the local clinical treatment plan (decided by the individual clinics) on the basis of liver contrast-enhanced MRI findings, analysed in the intention-to-image population. The minimal clinically important difference in the proportion of patients who would have change in their local treatment plan due to an additional liver contrast-enhanced MRI was 10%. This study is closed and registered in the Netherlands Trial Register, NL8039. FINDINGS: Between Dec 17, 2019, and July 31, 2021, 325 patients with colorectal liver metastases were assessed for eligibility. 298 patients were enrolled and included in the intention-to-treat population, including 177 males (59%) and 121 females (41%) with planned local therapy based on contrast-enhanced CT. A change in the local treatment plan based on liver contrast-enhanced MRI findings was observed in 92 (31%; 95% CI 26-36) of 298 patients. Changes were made for 40 patients (13%) requiring more extensive local therapy, 11 patients (4%) requiring less extensive local therapy, and 34 patients (11%) in whom the indication for curative-intent local therapy was revoked, including 26 patients (9%) with too extensive disease and eight patients (3%) with benign lesions on liver contrast-enhanced MRI (confirmed by a median follow-up of 21·0 months [IQR 17·5-24·0]). INTERPRETATION: Liver contrast-enhanced MRI should be considered in all patients scheduled for local treatment for colorectal liver metastases on the basis of contrast-enhanced CT imaging. FUNDING: The Dutch Cancer Society and Bayer AG - Pharmaceuticals.


Asunto(s)
Neoplasias Colorrectales , Neoplasias Hepáticas , Masculino , Femenino , Humanos , Medios de Contraste , Estudios Prospectivos , Tomografía Computarizada por Rayos X/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Neoplasias Hepáticas/patología , Imagen por Resonancia Magnética/métodos , Neoplasias Colorrectales/diagnóstico por imagen , Neoplasias Colorrectales/terapia , Neoplasias Colorrectales/patología
3.
Diagn Interv Imaging ; 105(2): 57-64, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37517969

RESUMEN

PURPOSE: The primary objective of this study was to determine the feasibility of ablation margin quantification using a standardized scanning protocol during thermal ablation (TA) of hepatocellular carcinoma (HCC), and a rigid registration algorithm. Secondary objectives were to determine the inter- and intra-observer variability of tumor segmentation and quantification of the minimal ablation margin (MAM). MATERIALS AND METHODS: Twenty patients who underwent thermal ablation for HCC were included. There were thirteen men and seven women with a mean age of 67.1 ± 10.8 (standard deviation [SD]) years (age range: 49.1-81.1 years). All patients underwent contrast-enhanced computed tomography examination under general anesthesia directly before and after TA, with preoxygenated breath hold. Contrast-enhanced computed tomography examinations were analyzed by radiologists using rigid registration software. Registration was deemed feasible when accurate rigid co-registration could be obtained. Inter- and intra-observer rates of tumor segmentation and MAM quantification were calculated. MAM values were correlated with local tumor progression (LTP) after one year of follow-up. RESULTS: Co-registration of pre- and post-ablation images was feasible in 16 out of 20 patients (80%) and 26 out of 31 tumors (84%). Mean Dice similarity coefficient for inter- and intra-observer variability of tumor segmentation were 0.815 and 0.830, respectively. Mean MAM was 0.63 ± 3.589 (SD) mm (range: -6.26-6.65 mm). LTP occurred in four out of 20 patients (20%). The mean MAM value for patients who developed LTP was -4.00 mm, as compared to 0.727 mm for patients who did not develop LTP. CONCLUSION: Ablation margin quantification is feasible using a standardized contrast-enhanced computed tomography protocol. Interpretation of MAM was hampered by the occurrence of tissue shrinkage during TA. Further validation in a larger cohort should lead to meaningful cut-off values for technical success of TA.


Asunto(s)
Carcinoma Hepatocelular , Ablación por Catéter , Neoplasias Hepáticas , Masculino , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/cirugía , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/cirugía , Ablación por Catéter/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento
4.
Int J Comput Assist Radiol Surg ; 17(10): 1775-1785, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35934773

RESUMEN

PURPOSE: Navigational strategies create a scenario whereby percutaneous needle-based interventions of the liver can be guided using both pre-interventional 3D imaging datasets and dynamic interventional ultrasound (US). To score how such technologies impact the needle placement process, we performed kinematic analysis on different user groups. METHODS: Using a custom biopsy phantom, three consecutive exercises were performed by both novices and experts (n = 26). The exercise came in three options: (1) US-guidance, (2) US-guidance with pre-interventional image-registration (US + Reg) and (3) US-guidance with pre-interventional image-registration and needle-navigation (US + Reg + Nav). The traveled paths of the needle were digitized in 3D. Using custom software algorithms, kinematic metrics were extracted and related to dexterity, decision making indices to obtain overall performance scores (PS). RESULTS: Kinematic analysis helped quantifying the visual assessment of the needle trajectories. Compared to US-guidance, novices yielded most improvements using Reg (PSavg(US) = 0.43 vs. PSavg(US+Reg) = 0.57 vs. PSavg(US+Reg+Nav) = 0.51). Interestingly, the expert group yielded a reversed trend (PSavg(US) = 0.71 vs PSavg(US+Reg) = 0.58 vs PSavg(US+Reg+Nav) = 0.59). CONCLUSION: Digitizing the movement trajectory allowed us to objectively assess the impact of needle-navigation strategies on percutaneous procedures. In particular, our findings suggest that these advanced technologies have a positive impact on the kinematics derived performance of novices.


Asunto(s)
Agujas , Cirugía Asistida por Computador , Computadores , Humanos , Fantasmas de Imagen , Cirugía Asistida por Computador/métodos , Ultrasonografía , Ultrasonografía Intervencional/métodos
5.
Cardiovasc Intervent Radiol ; 45(8): 1057-1063, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35618860

RESUMEN

PURPOSE: To investigate the biodistribution of holmium-166 microspheres (166Ho-MS) when administered after radiofrequency ablation (RFA) of early-stage hepatocellular carcinoma (HCC). The aim is to establish a perfused liver administration dose that results in a tumoricidal dose of holmium-166 on the hyperaemic zone around the ablation necrosis (i.e. target volume). MATERIALS AND METHODS: This is a multicentre, prospective, dose-escalation study in HCC patients with a solitary lesion 2-5 cm, or a maximum of 3 lesions of ≤ 3 cm each. The day after RFA patients undergo angiography and cone-beam CT (CBCT) with (super)selective infusion of technetium-99 m labelled microalbumin aggregates (99mTc-MAA). The perfused liver volume is segmented from the CBCT and 166Ho-MS is administered to this treatment volume 5-10 days later. The dose of holmium-166 is escalated in a maximum of 3 patient cohorts (60 Gy, 90 Gy and 120 Gy) until the endpoint is reached. SPECT/CT is used to determine the biodistribution of holmium-166. The endpoint is met when a dose of ≥ 120 Gy has been reached on the target volume in 9/10 patients of a cohort. Secondary endpoints include toxicity, local recurrence, disease-free and overall survival. DISCUSSION: This study aims to find the optimal administration dose of adjuvant radioembolization with 166Ho-MS after RFA. Ultimately, the goal is to bring the efficacy of thermal ablation up to par with surgical resection for early-stage HCC patients. TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT03437382.


Asunto(s)
Carcinoma Hepatocelular , Ablación por Catéter , Embolización Terapéutica , Neoplasias Hepáticas , Ablación por Radiofrecuencia , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/cirugía , Embolización Terapéutica/métodos , Holmio , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/tratamiento farmacológico , Neoplasias Hepáticas/cirugía , Estudios Prospectivos , Radioisótopos , Estudios Retrospectivos , Distribución Tisular , Resultado del Tratamiento
6.
Cardiovasc Intervent Radiol ; 45(5): 606-612, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35233662

RESUMEN

PURPOSE: The primary objective is to determine the minimal ablation margin required to achieve a local recurrence rate of < 10% in patients with hepatocellular carcinoma undergoing thermal ablation. Secondary objectives are to analyze the correlation between ablation margins and local recurrence and to assess efficacy. MATERIALS AND METHODS: This study is a prospective, multicenter, non-experimental, non-comparative, open-label study. Patients > 18 years with Barcelona Clinic Liver Cancer stage 0/A hepatocellular carcinoma (or B with a maximum of two lesions < 5 cm each) are eligible. Patients will undergo dual-phase contrast-enhanced computed tomography directly before and after ablation. Ablation margins will be quantitatively assessed using co-registration software, blinding assessors (i.e. two experienced radiologists) for outcome. Presence and location of recurrence are evaluated independently on follow-up scans by two other experienced radiologists, blinded for the quantitative margin analysis. A sample size of 189 tumors (~ 145 patients) is required to show with 80% power that the risk of local recurrence is confidently below 10%. A two-sided binomial z-test will be used to test the null hypothesis that the local recurrence rate is ≥ 10% for patients with a minimal ablation margin ≥ 2 mm. Logistic regression will be used to find the relationship between minimal ablation margins and local recurrence. Kaplan-Meier estimates are used to assess local and overall recurrence, disease-free and overall survival. DISCUSSION: It is expected that this study will result in a clear understanding of the correlation between ablation margins and local recurrence. Using co-registration software in future patients undergoing ablation for hepatocellular carcinoma may improve intraprocedural evaluation of technical success. Trial registration The Netherlands Trial Register (NL9713), https://www.trialregister.nl/trial/9713 .


Asunto(s)
Carcinoma Hepatocelular , Ablación por Catéter , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/patología , Carcinoma Hepatocelular/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/cirugía , Márgenes de Escisión , Estudios Multicéntricos como Asunto , Recurrencia Local de Neoplasia/cirugía , Estudios Prospectivos , Resultado del Tratamiento
7.
PLoS One ; 17(1): e0261939, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35025911

RESUMEN

PURPOSE: Percutaneous hepatic perfusion with melphalan (M-PHP) is increasingly used in patients with liver metastases from various primary tumors, yet data on colorectal liver metastases (CRLM) are limited. The aim of this study was to prospectively evaluate the efficacy and safety of M-PHP in patients with CRLM. MATERIALS AND METHODS: Prospective, single-center, single-arm phase II study of M-PHP with hemofiltration in patients with unresectable CRLM. Proven, extrahepatic metastatic disease was one of the exclusion criteria. Primary outcomes were overall response rate (ORR) and best overall response (BOR). Secondary outcomes were overall survival (OS), progression-free survival (PFS), hepatic PFS (hPFS), and safety. RESULTS: A total of 14 M-PHP procedures were performed in eight patients between March 2014 and December 2015. All patients (median age 56 years, ranging from 46 to 68) had received (extensive) systemic chemotherapy before entering the study. The ORR was 25.0%, with two out of eight patients showing partial response as BOR. Median OS was 17.3 months (ranging from 2.6 to 30.9) with a one-year OS of 50.0%. Median PFS and hPFS were 4.4 and 4.5 months, respectively. No serious adverse events occurred. Grade 3/4 hematologic adverse events were observed in the majority of patients, though all were transient and well-manageable. CONCLUSION: M-PHP is a safe procedure with only limited efficacy in patients with unresectable CRLM who already showed progression of disease after receiving one or more systemic treatment regimens.


Asunto(s)
Neoplasias Colorrectales/tratamiento farmacológico , Neoplasias Hepáticas/tratamiento farmacológico , Melfalán/farmacología , Anciano , Circulación Extracorporea , Femenino , Hemofiltración , Humanos , Hígado , Masculino , Melfalán/uso terapéutico , Persona de Mediana Edad , Perfusión , Supervivencia sin Progresión
8.
Eur J Radiol Open ; 8: 100367, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34286051

RESUMEN

PURPOSE: The goal of our study was to determine the influence of ultrasound (US)-coupled volume navigation on the use of computed tomography (CT) during minimally-invasive radiofrequency and microwave ablation procedures of liver lesions. METHOD: Twenty-five patients with 40 liver lesions of different histological origin were retrospectively analysed. Lesions were ablated following standard protocol, using 1) conventional US-guidance, 2) manual registered volume navigation (mVNav), 3) automatic registered (aVNav) or 4) CT-guidance. In case of ultrasonographically inconspicuous lesions, conventional US-guidance was abandoned and mVNav was used. If mVNav was also unsuccessful, the procedure was either continued with aVNav or CT-guidance. The number, size and location of the lesions targeted using the different approaches were documented. RESULTS: Of the 40 lesions, sixteen (40.0 %) could be targeted with conventional US-guidance only, sixteen (40.0 %) with mVNav, three (7.5 %) with aVNav and five (12.5 %) only through the use of CT-guidance. Of the three alternatives (mVNav, aVNav and CT only) the mean size of the lesions targeted using mVNav (9.1 ± 4.6 mm) was significantly smaller from those targeted using US-guidance only (20.4 ± 9.4 mm; p < 0.001). The location of the lesions did not influence the selection of the modality used to guide the ablation. CONCLUSIONS: In our cohort, mVNav allowed the ablation procedure to become less dependent on the use of CT. mVNav supported the ablation of lesions smaller than those that could be ablated with US only and doubled the application of minimally-invasive US-guided ablations.

9.
Ann Surg Oncol ; 28(2): 1130-1141, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32761328

RESUMEN

BACKGROUND: Ocular melanoma is the most common primary intraocular malignancy and has a very poor prognosis once liver metastases occur. The aim of this study was to prospectively assess the efficacy and safety of percutaneous hepatic perfusion with melphalan (M-PHP) using the new second-generation (GEN 2) hemofiltration system in patients with ocular melanoma metastases confined to the liver. METHODS: Prospective, single-center, single-arm, phase II study including patients with unresectable ocular melanoma metastases confined to the liver. Treatment consisted of two M-PHP procedures at 6-8 weeks interval. Procedures were performed using the CHEMOSAT (GEN 2) system with 3 mg/kg melphalan. Primary endpoints were overall response rate (ORR) and best overall response (BOR). Secondary endpoints included overall survival (OS), progression-free survival (PFS), hepatic PFS (hPFS), and safety. RESULTS: Sixty-four M-PHP procedures were performed in 35 patients between February 2014 and June 2017. The ORR was 72%. BOR was as follows: complete response in 3%, partial response in 69%, stable disease in 13%, and progressive disease in 16%. There was no treatment-related mortality. Fourteen serious adverse events occurred. At a median follow-up of 19.1 months (range 5.6-69.5), median OS was 19.1 months and was significantly longer in responders than in nonresponders (27.5 vs. 11.9 months, p < 0.001). The 1- and 2-year OS was 77% and 43%, respectively. PFS and hPFS were 7.6 and 11.2 months, respectively. CONCLUSIONS: M-PHP using the GEN 2 filter can achieve a high ORR and prolonged survival in patients with liver-only ocular melanoma metastases.


Asunto(s)
Neoplasias Hepáticas , Melanoma , Antineoplásicos Alquilantes/uso terapéutico , Quimioterapia del Cáncer por Perfusión Regional , Femenino , Humanos , Hígado , Neoplasias Hepáticas/tratamiento farmacológico , Masculino , Melanoma/tratamiento farmacológico , Melfalán/uso terapéutico , Perfusión , Estudios Prospectivos
10.
Curr Urol ; 10(2): 87-91, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28785193

RESUMEN

BACKGROUND/AIMS: Double J (JJ) stents for treating obstructive ureteral pathology are generally inserted through a retrograde route with cystoscopic guidance. Antegrade percutaneous insertion using fluoroscopy can be performed alternatively but is less known. Indications, success rate and complications of antegrade ureteral stenting were evaluated. METHODS: Data of consecutive patients in which antegrade ureteral stenting was performed were retrospectively analysed using the radiology information system and patient records. Patient characteristics, details of the antegrade JJ stent insertion procedure and registered complications were collected. Furthermore, it was investigated if prior to the antegrade procedure a retrograde attempt for JJ stent insertion was performed. RESULTS: Total 130 attempts for antegrade JJ stent insertion were performed in 100 patients. A percutaneous nephrostomy catheter had already been placed in the majority of kidneys (n = 109) for initial treatment of hydronephrosis. Most prevelant indication for a JJ stent was obstructive ureteral pathology due to malignancy (n = 63). A JJ stent was successfully inserted in 125 of 130 procedures. In 21 cases, previous retrograde ureteral stenting had failed but, subsequent antegrade ureteral stenting was successful. There were 8 procedure related complications; 6 infections, 1 false tract and 1 malposition. CONCLUSION: Antegrade percutaneous insertion of a JJ stent is a good alternative for retrograde insertion.

12.
Cardiovasc Intervent Radiol ; 40(8): 1196-1205, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28451811

RESUMEN

INTRODUCTION: Percutaneous hepatic perfusion (PHP) with melphalan is an effective treatment for patients with hepatic metastases, but associated with high rates of bone marrow depression. To reduce systemic toxicity, improvements have been made to the filtration system. In pre-clinical studies, the Delcath System's GEN2 filter was superior to the first-generation filters. In this clinical study, we analysed the pharmacokinetics and toxicity of PHP using the new GEN2 filter. METHODS AND MATERIALS: Starting February 2014, two prospective phase II studies were initiated in patients with hepatic metastases from ocular melanoma or colorectal cancer. In 10 PHP procedures performed in the first 7 enrolled patients, blood samples were obtained to determine filter efficiency and systemic drug exposure. PHP was performed with melphalan 3 mg/kg with a maximum of 220 mg. Complications were assessed according to CTCAE v4.03. Response was assessed according to RECIST 1.1. RESULTS: Pharmacokinetic analysis of blood samples showed an overall filter efficiency of 86% (range 71.1-95.5%). The mean filter efficiency decreased from 95.4% 10 min after the start of melphalan infusion to 77.5% at the end of the procedure (p = 0.051). Bone marrow depression was seen after up to 80.0% of 10 procedures, but was self-limiting and mostly asymptomatic. No hypotension-related complications or procedure-related mortality occurred. CONCLUSION: The GEN2 filter has a higher melphalan filter efficiency compared to the first-generation filters and a more consistent performance. PHP with the GEN2 filter appears to have an acceptable safety profile, but this needs further validation in larger studies.


Asunto(s)
Quimioterapia del Cáncer por Perfusión Regional/métodos , Hemofiltración/instrumentación , Hemofiltración/métodos , Neoplasias Hepáticas/tratamiento farmacológico , Neoplasias Hepáticas/secundario , Melfalán/uso terapéutico , Adulto , Antineoplásicos Alquilantes/administración & dosificación , Antineoplásicos Alquilantes/uso terapéutico , Neoplasias Colorrectales/patología , Neoplasias del Ojo/patología , Femenino , Humanos , Masculino , Melanoma/secundario , Melfalán/administración & dosificación , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
13.
Cardiovasc Intervent Radiol ; 40(6): 914-923, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28204959

RESUMEN

PURPOSE: To determine the accuracy of automatic and manual co-registration methods for image fusion of three-dimensional computed tomography (CT) with real-time ultrasonography (US) for image-guided liver interventions. MATERIALS AND METHODS: CT images of a skills phantom with liver lesions were acquired and co-registered to US using GE Logiq E9 navigation software. Manual co-registration was compared to automatic and semiautomatic co-registration using an active tracker. Also, manual point registration was compared to plane registration with and without an additional translation point. Finally, comparison was made between manual and automatic selection of reference points. In each experiment, accuracy of the co-registration method was determined by measurement of the residual displacement in phantom lesions by two independent observers. RESULTS: Mean displacements for a superficial and deep liver lesion were comparable after manual and semiautomatic co-registration: 2.4 and 2.0 mm versus 2.0 and 2.5 mm, respectively. Both methods were significantly better than automatic co-registration: 5.9 and 5.2 mm residual displacement (p < 0.001; p < 0.01). The accuracy of manual point registration was higher than that of plane registration, the latter being heavily dependent on accurate matching of axial CT and US images by the operator. Automatic reference point selection resulted in significantly lower registration accuracy compared to manual point selection despite lower root-mean-square deviation (RMSD) values. CONCLUSION: The accuracy of manual and semiautomatic co-registration is better than that of automatic co-registration. For manual co-registration using a plane, choosing the correct plane orientation is an essential first step in the registration process. Automatic reference point selection based on RMSD values is error-prone.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Ultrasonografía/métodos , Humanos , Hígado , Imagen Multimodal/métodos , Reproducibilidad de los Resultados
14.
Cardiovasc Intervent Radiol ; 39(12): 1708-1715, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27671151

RESUMEN

PURPOSE: The aim of this study was to compare patient characteristics and midterm outcomes after RFA for unresectable Hepatocellular carcinoma (HCC) in Asian and European cohorts. MATERIALS AND METHODS: The study was based on retrospective analysis of 279 patients (mean 64.8 ± 12.1 years; 208 males) treated with RFA for de novo HCC in tertiary referral centers in Singapore and the Netherlands, with median follow-up of 28.2 months (quartiles: 13.1-40.5 months). Cumulative incidence of recurrence and death were analyzed using a competing risk model. RESULTS: Age was higher in the Asian group: 66.5 versus 60.1 years (p < 0.0001). The most common etiology was hepatitis B in the Asian group (48.0 %) and alcohol-induced cirrhosis in Europeans (54.4 %); p < 0.001. Asian patients had less advanced disease: 35.5, 55.0, and 3.0 %, respectively, had BCLC 0, A, and B versus 21.5, 58.2, and 15.2 % in the European group (p = 0.01). The cumulative incidences of recurrence in the Asian group at 1, 2, 3, and 5 years were 37.0, 56.4, 62.3, and 67.7 %, respectively, compared to 32.6, 47.2, 49.7, and 53.4 % in the European group (p = 0.474). At 1, 2, 3, and 5 years, the cumulative incidence rates of death in the Asian group were 2.0, 3.9, 4.9, and 4.9 %, respectively, corresponding to 7.7, 9.2, 14.1, and 21.0 % in the European group (p = 0.155). CONCLUSION: Similar short-term treatment outcomes are achieved with RFA in HCC patients in the South-East Asian and Northern-European populations. Midterm recurrence and death rates differ between the groups as a result of differences in baseline patient characteristics and patient selection. Our study provides insight relevant to the design of future international studies.


Asunto(s)
Carcinoma Hepatocelular/epidemiología , Carcinoma Hepatocelular/cirugía , Ablación por Catéter/métodos , Neoplasias Hepáticas/epidemiología , Neoplasias Hepáticas/cirugía , Factores de Edad , Anciano , Pueblo Asiatico/estadística & datos numéricos , Causalidad , Comorbilidad , Femenino , Estudios de Seguimiento , Hepatitis B/epidemiología , Humanos , Incidencia , Cirrosis Hepática Alcohólica/epidemiología , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/epidemiología , Estudios Retrospectivos , Resultado del Tratamiento , Población Blanca/estadística & datos numéricos
15.
J Vis Exp ; (113)2016 07 31.
Artículo en Inglés | MEDLINE | ID: mdl-27501370

RESUMEN

Unresectable liver metastases of colorectal cancer can be treated with systemic chemotherapy, aiming to limit the disease, extend survival or turn unresectable metastases into resectable ones. Some patients however, suffer from side effects or progression under systemic treatment. For patients with metastasized uveal melanoma there are no standard systemic therapy options. For patients without extrahepatic disease, isolated liver perfusion (IHP) may enable local disease control with limited systemic side effects. Previously, this was performed during open surgery with satisfying results, but morbidity and mortality related to the open procedure, prohibited a widespread application. Therefore, percutaneous hepatic perfusion (PHP) with simultaneous chemofiltration was developed. Besides decreasing morbidity and mortality, this procedure can be repeated, hopefully leading to a higher response rate and improved survival (by local control of disease). During PHP, catheters are placed in the proper hepatic artery, to infuse the chemotherapeutic agent, and in the inferior caval vein to aspirate the chemosaturated blood returning through the hepatic veins. The caval vein catheter is a double balloon catheter that prohibits leakage into the systemic circulation. The blood returning from the hepatic veins is aspirated through the catheter fenestrations and then perfused through an extra-corporeal filtration system. After filtration, the blood is returned to the patient by a third catheter in the right internal jugular vein. During PHP a high dose of melphalan is infused into the liver, which is toxic and would lead to life threatening complications when administered systemically. Because of the significant hemodynamic instability resulting from the combination of caval vein occlusion and chemofiltration, hemodynamic monitoring and hemodynamic support is of paramount importance during this complex procedure.


Asunto(s)
Neoplasias Hepáticas , Quimioterapia del Cáncer por Perfusión Regional , Neoplasias Colorrectales , Humanos , Neoplasias Hepáticas/tratamiento farmacológico , Melfalán
16.
Cardiovasc Intervent Radiol ; 39(6): 801-14, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26718962

RESUMEN

Liver malignancies are a major burden of disease worldwide. The long-term prognosis for patients with unresectable tumors remains poor, despite advances in systemic chemotherapy, targeted agents, and minimally invasive therapies such as ablation, chemoembolization, and radioembolization. Thus, the demand for new and better treatments for malignant liver tumors remains high. Surgical isolated hepatic perfusion (IHP) has been shown to be effective in patients with various hepatic malignancies, but is complex, associated with high complication rates and not repeatable. Percutaneous isolated liver perfusion (PHP) is a novel minimally invasive, repeatable, and safer alternative to IHP. PHP is rapidly gaining interest and the number of procedures performed in Europe now exceeds 200. This review discusses the indications, technique and patient management of PHP and provides an overview of the available data.


Asunto(s)
Quimioterapia del Cáncer por Perfusión Regional/métodos , Neoplasias Hepáticas/terapia , Antineoplásicos Alquilantes/administración & dosificación , Carcinoma Hepatocelular/tratamiento farmacológico , Humanos , Melfalán/administración & dosificación
17.
Ned Tijdschr Geneeskd ; 159: A9326, 2015.
Artículo en Holandés | MEDLINE | ID: mdl-26332819

RESUMEN

Ascites can lead to many symptoms, and often occurs in patients with an end-stage malignancy such as ovarian, pancreatic, colonic, or gastric cancer. Intermittent ascites drainage is applied in these patients as a palliative measure. As frequent drainage is necessary, a subcutaneously tunnelled permanent ascites catheter is a good alternative for intermittent drainage. The patient can open - and then re-close - the catheter when abdominal pressure increases. We inserted 35 subcutaneously permanent ascites catheters in the course of the past 3.5 years in the Leiden University Medical Centre. The success rate was 100% and the complication risk was 2.9%. A subcutaneously tunnelled ascites catheter is an effective and safe palliative treatment for patients with end-stage malignant disease and suffering from ascites.


Asunto(s)
Ascitis/cirugía , Catéteres de Permanencia , Drenaje/métodos , Ascitis/complicaciones , Catéteres de Permanencia/efectos adversos , Humanos , Autocuidado
18.
Radiology ; 276(1): 12-29, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26101919

RESUMEN

Luminescence imaging-based guidance technologies are increasingly gaining interest within surgical and radiologic disciplines. Their promise to help visualize molecular features of disease in real time and with microscopic detail is considered desirable. Integrating luminescence imaging with three-dimensional radiologic- and/or nuclear medicine-based preinterventional imaging may overcome limitations such as the limited tissue penetration of luminescence signals. At the same time, the beneficial features of luminescence imaging may be used to complement the routinely used radiologic- and nuclear medicine-based modalities. To fully exploit this integrated concept, and to relate the largely experimental luminesce-based guidance approaches into perspective with routine imaging approaches, it is essential to understand the advantages and limitations of this relatively new modality. By providing an overview of the available luminescence technologies and the various clinically evaluated exogenous luminescent tracers (fluorescent, hybrid, and theranostic tracers), this review attempts to place luminescence-based interventional molecular imaging technologies into perspective to the available radiologic- and/or nuclear medicine-based imaging technologies. At the same time, the transition from anatomic to physiologic and even molecular interventional luminescence imaging is illustrated.


Asunto(s)
Luminiscencia , Imagen Molecular/métodos , Humanos
19.
Biomed Res Int ; 2014: 890230, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25157372

RESUMEN

Prognosis of patients with pancreatic cancer is poor. Even the small minority that undergoes resection with curative intent has low 5-year survival rates. This may partly be explained by the high number of irradical resections, which results in local recurrence and impaired overall survival. Currently, ultrasonography is used during surgery for resectability assessment and frozen-section analysis is used for assessment of resection margins in order to decrease the number of irradical resections. The introduction of minimal invasive techniques in pancreatic surgery has deprived surgeons from direct tactile information. To improve intraoperative assessment of pancreatic tumor extension, enhanced or novel intraoperative imaging technologies accurately visualizing and delineating cancer cells are necessary. Emerging modalities are intraoperative near-infrared fluorescence imaging and freehand nuclear imaging using tumor-specific targeted contrast agents. In this review, we performed a meta-analysis of the literature on laparoscopic ultrasonography and we summarized and discussed current and future intraoperative imaging modalities and their potential for improved tumor demarcation during pancreatic surgery.


Asunto(s)
Diagnóstico por Imagen/métodos , Cuidados Intraoperatorios/métodos , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/cirugía , Humanos , Neoplasias Pancreáticas/diagnóstico por imagen , Cintigrafía , Ultrasonografía
20.
Radiology ; 266(3): 862-70, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23204545

RESUMEN

PURPOSE: To perform clustered analysis of fracture-free probabilities of intact nontreated vertebrae after percutaneous vertebroplasty (PVP) in painful long-standing osteoporotic vertebral compression fractures (OVCFs) to determine risk factors for new vertebral fractures and estimate fracture-free probabilities of multiple intact nontreated vertebrae given their patient- and vertebra-specific covariate status. MATERIALS AND METHODS: Informed consent and institutional review board approval were obtained. A total of 115 patients who underwent PVP for 216 painful long-standing OVCFs were prospectively followed up to detect new OVCFs during the 1st postoperative year. A total of 1031 intact vertebrae were available for clustered analysis of fracture-free probabilities by using a Cox proportional hazard frailty model. A clustered analysis takes clustering or correlation of fracture-free survival probabilities of individual intact vertebrae within one patient into account to improve estimates of fracture-free probabilities and risk factors. Relevant patient- and vertebra-specific covariates were included. Volumetric analysis of intradiskal cement leakage was performed by using a receiver operating characteristic curve (ROC). RESULTS: Three- and 12-month vertebral fracture-free probability was 97.0% and 94.5%, respectively. Strong patient-level risk factors included low bone mineral density (hazard ratio [HR], 0.53 per unit increase), high spinal deformity index (HR, 2.23 per five units increase), and low fracture age (HR, 0.52 per 2 months increase). Strong vertebra-specific risk factors were thoracolumbar localization (HR, 2.33), vicinity to the treated level (adjacent level HR, 3.53), and presence of intradiskal cement leakage (HR, 8.21). Fracture-free probabilities of individual vertebrae were clustered within a patient (ie, not independent) (P = .009). The predicted 1-year fracture-free probability of an individual vertebra could be as high as 99.8% or as low as 19.9% based on absence or presence of risk factors, respectively. Larger intradiskal cement leakage volumes were associated with a higher likelihood of occurrence of new adjacent OVCFs (area under the ROC curve, 0.70). CONCLUSION: New vertebral fractures after PVP were clustered within patients and depended heavily on the presence or absence of both patient- and vertebra-specific risk factors. Intradiskal cement leakage was a pronounced augmentation-related risk factor, for which a volumetric association was found.


Asunto(s)
Fracturas por Compresión/epidemiología , Fracturas por Compresión/terapia , Fracturas Osteoporóticas/epidemiología , Fracturas Osteoporóticas/terapia , Fracturas de la Columna Vertebral/epidemiología , Fracturas de la Columna Vertebral/terapia , Vertebroplastia/estadística & datos numéricos , Anciano , Cementos para Huesos , Análisis por Conglomerados , Comorbilidad , Extravasación de Materiales Terapéuticos y Diagnósticos/epidemiología , Extravasación de Materiales Terapéuticos y Diagnósticos/etiología , Femenino , Humanos , Disco Intervertebral/efectos de los fármacos , Masculino , Países Bajos/epidemiología , Prevalencia , Factores de Riesgo , Insuficiencia del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA