1.
Magn Reson Med ; 88(6): 2378-2394, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35916545

RESUMEN

PURPOSE: Very high gradient amplitudes played out over extended time intervals as required for second-order motion-compensated cardiac DTI may violate the assumption of a linear time-invariant gradient system model. The aim of this work was to characterize diffusion gradient-related system nonlinearity and propose a correction approach for echo-planar and spiral spin-echo motion-compensated cardiac DTI. METHODS: Diffusion gradient-induced eddy currents of 9 diffusion directions were characterized at b values of 150 s/mm2 and 450 s/mm2 for a 1.5 Tesla system and used to correct phantom, ex vivo, and in vivo motion-compensated cardiac DTI data acquired with echo-planar and spiral trajectories. Predicted trajectories were calculated using gradient impulse response function and diffusion gradient strength- and direction-dependent zeroth- and first-order eddy current responses. A reconstruction method was implemented using the predicted k $$ k $$ -space trajectories to additionally include off-resonances and concomitant fields. Resulting images were compared to a reference reconstruction omitting diffusion gradient-induced eddy current correction. RESULTS: Diffusion gradient-induced eddy currents exhibited nonlinear effects when scaling up the gradient amplitude and could not be described by a 3D basis alone. This indicates that a gradient impulse response function does not suffice to describe diffusion gradient-induced eddy currents. Zeroth- and first-order diffusion gradient-induced eddy current effects of up to -1.7 rad and -16 to +12 rad/m, respectively, were identified. Zeroth- and first-order diffusion gradient-induced eddy current correction yielded improved image quality upon image reconstruction. CONCLUSION: The proposed approach offers correction of diffusion gradient-induced zeroth- and first-order eddy currents, reducing image distortions to promote improvements of second-order motion-compensated spin-echo cardiac DTI.


Asunto(s)
Algoritmos , Imagen de Difusión Tensora , Artefactos , Encéfalo , Imagen de Difusión por Resonancia Magnética , Imagen de Difusión Tensora/métodos , Imagen Eco-Planar/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Movimiento (Física) , Fantasmas de Imagen
2.
Comput Med Imaging Graph ; 99: 102075, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35636378

RESUMEN

Cardiac diffusion tensor imaging (cDTI) provides invaluable information about the state of myocardial microstructure. For further clinical dissemination, free-breathing acquisitions are desired, which however require image registration prior to tensor estimation. Due to the varying contrast and the intrinsically low signal-to-noise ratio (SNR), registration is very challenging and thus can introduce additional errors in the tensor estimation. In the work at hand it is hypothesized, that by incorporating spatial information and physiologically plausible priors into the fitting algorithm, the robustness of diffusion tensor estimation can be improved. To this end, we present a parameterized pipeline to generate synthetic data, that captures the statistics including spatial correlations of diffusion tensors and motion of the heart. The synthetic data is used to train a residual convolutional neural network (CNN) to estimate diffusion tensors from unregistered in-vivo cDTI data. Using in-silico data, the synthetically trained CNN is demonstrated to yield increased tensor estimation accuracy and precision when compared to conventional registration followed by least squares fitting. The network outputs fewer outliers especially at the myocardial borders. In-vivo feasibility using data from five healthy subjects demonstrates the utility of the synthetically trained network. The in-vivo results predicted by the synthetically trained CNN are found to be consistent with the registered least-squares estimates while showing fewer outliers and reduced noise. Even in low SNR regimes, the network results in robust tensor estimation, enabling scan time reduction by reduced-average acquisition in-vivo. Finally, to investigate the network's capability of discriminating between healthy and lesioned tissue, the in-vivo data was artificially augmented showing preserved classification of tissue states based on diffusion metrics.


Asunto(s)
Imagen de Difusión Tensora , Redes Neurales de la Computación , Algoritmos , Imagen de Difusión Tensora/métodos , Corazón/diagnóstico por imagen , Humanos , Relación Señal-Ruido
3.
J Cardiovasc Magn Reson ; 23(1): 103, 2021 09 20.
Artículo en Inglés | MEDLINE | ID: mdl-34538266

RESUMEN

BACKGROUND: We examined the dynamic response of the myocardium to infarction in a longitudinal porcine study using relaxometry, functional as well as diffusion cardiovascular magnetic resonance (CMR). We sought to compare non contrast CMR methods like relaxometry and in-vivo diffusion to contrast enhanced imaging and investigate the link of microstructural and functional changes in the acute and chronically infarcted heart. METHODS: CMR was performed on five myocardial infarction pigs and four healthy controls. In the infarction group, measurements were obtained 2 weeks before 90 min occlusion of the left circumflex artery, 6 days after ischemia and at 5 as well as 9 weeks as chronic follow-up. The timing of measurements was replicated in the control cohort. Imaging consisted of functional cine imaging, 3D tagging, T2 mapping, native as well as gadolinium enhanced T1 mapping, cardiac diffusion tensor imaging, and late gadolinium enhancement imaging. RESULTS: Native T1, extracellular volume (ECV) and mean diffusivity (MD) were significantly elevated in the infarcted region while fractional anisotropy (FA) was significantly reduced. During the transition from acute to chronic stages, native T1 presented minor changes (< 3%). ECV as well as MD increased from acute to the chronic stages compared to baseline: ECV: 125 ± 24% (day 6) 157 ± 24% (week 5) 146 ± 60% (week 9), MD: 17 ± 7% (day 6) 33 ± 14% (week 5) 29 ± 15% (week 9) and FA was further reduced: - 31 ± 10% (day 6) - 38 ± 8% (week 5) - 36 ± 14% (week 9). T2 as marker for myocardial edema was significantly increased in the ischemic area only during the acute stage (83 ± 3 ms infarction vs. 58 ± 2 ms control p < 0.001 and 61 ± 2 ms in the remote area p < 0.001). The analysis of functional imaging revealed reduced left ventricular ejection fraction, global longitudinal strain and torsion in the infarct group. At the same time the transmural helix angle (HA) gradient was steeper in the chronic follow-up and a correlation between longitudinal strain and transmural HA gradient was detected (r = 0.59 with p < 0.05). Comparing non-gadolinium enhanced data T2 mapping showed the largest relative change between infarct and remote during the acute stage (+ 33 ± 4% day 6, with p = 0.013 T2 vs. MD, p = 0.009 T2 vs. FA and p = 0.01 T2 vs. T1) while FA exhibited the largest relative change between infarct and remote during the chronic follow-up (+ 31 ± 2% week 5, with p = N.S. FA vs. MD, p = 0.03 FA vs. T2 and p = 0.003 FA vs. T1). Overall, diffusion parameters provided a higher contrast (> 23% for MD and > 27% for FA) during follow-up compared to relaxometry (T1 17-18%/T2 10-20%). CONCLUSION: During chronic follow-up after myocardial infarction, cardiac diffusion tensor imaging provides a higher sensitivity for mapping microstructural alterations when compared to non-contrast enhanced relaxometry with the added benefit of providing directional tensor information to assess remodelling of myocyte aggregate orientations, which cannot be otherwise assessed.


Asunto(s)
Infarto del Miocardio , Función Ventricular Izquierda , Animales , Medios de Contraste , Imagen de Difusión Tensora , Gadolinio , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética , Infarto del Miocardio/diagnóstico por imagen , Miocardio , Valor Predictivo de las Pruebas , Volumen Sistólico , Porcinos
5.
Magn Reson Med ; 84(5): 2561-2576, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32530062

RESUMEN

PURPOSE: Cardiac diffusion tensor imaging using EPI readout is prone to image distortions in the presence of field inhomogeneities. In this work, a framework to analyze and correct image distortions in cardiac diffusion tensor imaging is presented. METHODS: A multi-coil reconstruction framework was implemented to enable field map-based off-resonance correction. Numerical simulations were used to examine reconstruction performance for EPI phase-encode directions blip up-down and down-up for different degrees of off-resonance gradients and varying field map resolution. The impact of coil encoding was analyzed using the g-factor and normalized RMSE. Finally, the proposed method was tested on free-breathing in vivo cardiac diffusion tensor imaging data acquired in healthy subjects at 3 Tesla. RESULTS: Depending on the local field map gradient strength and polarity and the selected phase-encode direction, field inhomogeneities lead to either local spatial compression or stretching with standard image reconstruction. Although spatial compression results in loss of image resolution upon field map-based reconstruction, spatial stretching can be recovered once multiple receive coils are utilized. Multi-coil reconstruction was found to reduce the normalized RMSE from 34.3% to 8.1% for image compression, and 33.6% to 1.8% for image stretching, with resulting average g-factors 14.7 ± 2.9 and 1.2 ± 0.1, respectively. In vivo, multi-coil field map-based reconstruction yielded improved alignment of angle maps with anatomical cine data. CONCLUSION: Multi-coil, field map-based image reconstruction for echo-planar cardiac diffusion tensor imaging allows accurate image reconstruction provided that the phase-encode direction and polarity is chosen to principally align with the direction and polarity of the prominent gradients of field inhomogeneities.


Asunto(s)
Artefactos , Imagen de Difusión Tensora , Algoritmos , Encéfalo , Imagen de Difusión por Resonancia Magnética , Imagen Eco-Planar , Humanos , Procesamiento de Imagen Asistido por Computador
6.
Magn Reson Med ; 84(1): 277-288, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-31868257

RESUMEN

PURPOSE: To address motion in cardiac DWI, stimulated-echo acquisition mode (STEAM) and second-order motion-compensated spin-echo (SE) sequences have been proposed. Despite applying motion-compensation strategies, residual motion can cause misleading signal attenuation. The purpose of this study is to estimate the motion-induced error in both sequences by analysis of image phase. METHODS: Diffusion-weighted motion-compensated SE sequences and STEAM imaging was applied in vivo with diffusion encoding along 3 orthogonal directions. A b-value range of 100 to 600 s/mm2 and trigger delays of 25%, 50%, and 75% of end systole and middiastole were used. Eddy-current contributions were obtained from phantom measurements. After computation of motion-induced phase maps, the amount of signal dephasing was computed from phase gradients, and the resulting errors in diffusion tensor parameters were calculated. RESULTS: Motion-induced dephasing from the STEAM sequence showed less dependency on the b-value and no dependency on the heart phase, whereas SE imaging performed best at 75% end systole followed by 50% end systole and middiastole. For a typical experimental setting, errors of 3.3%/3.0% mean diffusivity, 4.9%/4.8% fractional anisotropy, 2.9º/3.2º helix angulation, 0.8º/0.7º transverse angulation, and 9.9º/10.0º sheet angulation (SE/STEAM) were calculated. CONCLUSION: Image phase contains valuable information regarding uncompensated motion and eddy currents in cardiac DTI. Although the trigger delay window for SE is narrower compared with the STEAM-based approach, imaging in both systole and diastole is feasible and both sequences perform similarly if the trigger delays are selected carefully with SE.


Asunto(s)
Imagen de Difusión Tensora , Corazón , Anisotropía , Imagen de Difusión por Resonancia Magnética , Corazón/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador , Movimiento (Física)
7.
NMR Biomed ; 33(1): e4138, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31664745

RESUMEN

In MR elastography (MRE), zeroth moment balanced motion-encoding gradients (MEGs) are incorporated into MRI sequences to induce a phase shift proportional to the local displacement caused by external actuation. To maximize the signal-to-noise ratio (SNR), fractional encoding is employed, i.e., the MEG duration is reduced below the wave period. Here, gradients encode primarily the velocity of the motion-reducing encoding efficiency. Thus, in GRE-MRE, T2 * decay and motion sensitivity have to be balanced, imposing a lower limit on repetition times (TRs). We propose to use a single trapezoidal gradient, a "unipolar gradient", to directly encode spin displacement. Such gradients cannot be used in conventional sequences as they exhibit a large zeroth moment and dephase magnetization. By time-reversing a spoiled SSFP sequence, the spoiling gradient becomes an efficient unipolar MEG. The proposed "unipolar MRE" technique benefits from this approach in three ways: first, displacement encoding is split over multiple TRs increasing motion sensitivity; second, spoiler and MEG coincide, allowing a reduction in TR; third, motion sensitivity of a typical unipolar lobe is of an order of magnitude higher than a bipolar MEG of equal duration. In this work, motion encoding using unipolar MRE is analyzed using the extended phase graph (EPG) formalism with a periodic motion propagator. As an approximation, the two-transverse TR approximation for diffusion-weighted SSFP is extended to incorporate cyclic motion. A complex encoding efficiency metric is introduced to compare the displacement fields of unipolar and conventional GRE-MRE sequences in both magnitude and phase. The derived theoretical encoding equations are used to characterize the proposed sequence using an extensive parameter study. Unipolar MRE is validated against conventional GRE-MRE in a phantom study showing excellent agreement between measured displacement fields. In addition, unipolar MRE yields significantly increased octahedral shear strain-SNR relative to conventional GRE-MRE and allows for the recovery of high stiffness inclusions, where conventional GRE-MRE fails.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Imagen por Resonancia Magnética , Análisis Numérico Asistido por Computador , Simulación por Computador , Movimiento (Física) , Fantasmas de Imagen
8.
J Cardiovasc Magn Reson ; 21(1): 56, 2019 09 05.
Artículo en Inglés | MEDLINE | ID: mdl-31484544

RESUMEN

BACKGROUND: In-vivo cardiovascular magnetic resonance (CMR) diffusion tensor imaging (DTI) allows imaging of alterations of cardiac fiber architecture in diseased hearts. Cardiac amyloidosis (CA) causes myocardial infiltration of misfolded proteins with unknown consequences for myocardial microstructure. This study applied CMR DTI in CA to assess microstructural alterations and their consequences for myocardial function compared to healthy controls. METHODS: Ten patients with CA (8 AL, 2 ATTR) and ten healthy controls were studied using a diffusion-weighed second-order motion-compensated spin-echo sequence at 1.5 T. Additionally, left ventricular morphology, ejection fraction, strain and native T1 values were obtained in all subjects. In CA patients, T1 mapping was repeated after the administration of gadolinium for extracellular volume fraction (ECV) calculation. CMR DTI analysis was performed to yield the scalar diffusion metrics mean diffusivity (MD) and fractional anisotropy (FA) as well as the characteristics of myofiber orientation including helix, transverse and E2A sheet angle (HA, TA, E2A). RESULTS: MD and FA were found to be significantly different between CA patients and healthy controls (MD 1.77 ± 0.17 10- 3 vs 1.41 ± 0.07 10- 3 mm2/s, p <  0.001; FA 0.25 ± 0.04 vs 0.35 ± 0.03, p <  0.001). MD demonstrated an excellent correlation with native T1 (r = 0.908, p <  0.001) while FA showed a significant correlation with ECV in the CA population (r = - 0.851, p <  0.002). HA exhibited a more circumferential orientation of myofibers in CA patients, in conjunction with a higher TA standard deviation and a higher absolute E2A sheet angle. The transmural HA slope was found to be strongly correlated with the global longitudinal strain (r = 0.921, p < 0.001). CONCLUSION: CMR DTI reveals significant alterations of scalar diffusion metrics in CA patients versus healthy controls. Elevated MD and lower FA values indicate myocardial disarray with higher diffusion in CA that correlates well with native T1 and ECV measures. In CA patients, CMR DTI showed pronounced circumferential orientation of the myofibers, which may provide the rationale for the reduction of global longitudinal strain that occurs in amyloidosis patients. Accordingly, CMR DTI captures specific features of amyloid infiltration, which provides a deeper understanding of the microstructural consequences of CA.


Asunto(s)
Amiloidosis/diagnóstico por imagen , Cardiomiopatías/diagnóstico por imagen , Imagen de Difusión Tensora , Imagen por Resonancia Cinemagnética , Anciano , Amiloidosis/patología , Amiloidosis/fisiopatología , Cardiomiopatías/patología , Cardiomiopatías/fisiopatología , Estudios de Casos y Controles , Medios de Contraste/administración & dosificación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Miocardio/patología , Compuestos Organometálicos/administración & dosificación , Valor Predictivo de las Pruebas , Estudios Prospectivos , Volumen Sistólico , Función Ventricular Izquierda