1.
J Patient Rep Outcomes ; 8(1): 3, 2024 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-38175456

RESUMEN

PURPOSE: The FitMáx© was developed as a questionnaire-based instrument to estimate Cardiorespiratory Fitness (CRF) expressed as oxygen uptake at peak exercise (VO2peak). Test-retest reliability is a clinometric measurement property, which defines stability over time if multiple measurements are performed (i.e. reliability). The present study aimed to assess the test-retest reliability of the FitMáx©-questionnaire in different patient groups. PATIENTS AND METHODS: A total of 127 cardiac, pulmonary and oncology patients and healthy subjects aged 19-84 years who completed the questionnaire twice within an average of 18 days were included for analysis. Participants were in a stable clinical situation (no acute disease or participating in a training program). To determine the test-retest reliability, the Intraclass Correlation Coefficient (ICC) and Standard Error of the Measurement (SEM) was calculated between the first (T0) and second (T1) administration of the questionnaires. RESULTS: An excellent agreement was found between the FitMáx©-questionnaire scores at T0 and T1, with an ICC of 0.97 (SEM 1.91) in the total study population and an ICC ranging from 0.93 to 0.98 (SEM 1.52-2.27) in the individual patient groups. CONCLUSION: The FitMáx©-questionnaire proves to be reliable and stable over time to estimate CRF of patients and healthy subjects. Trial registration NTR (Netherlands Trial Register), NL8846. Registered 25 August 2020, https://trialsearch.who.int/Trial2.aspx?TrialID=NL8846.


Asunto(s)
Capacidad Cardiovascular , Estado de Salud , Humanos , Ejercicio Físico , Voluntarios Sanos , Reproducibilidad de los Resultados , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Encuestas y Cuestionarios
3.
J Patient Rep Outcomes ; 7(1): 73, 2023 07 19.
Artículo en Inglés | MEDLINE | ID: mdl-37466784

RESUMEN

BACKGROUND: Evaluating the criterion validity and responsiveness of the self-reported FitMáx©-questionnaire, Duke Activity Status Index (DASI) and Veterans Specific Activity Questionnaire (VSAQ) to monitor aerobic capacity in cancer survivors. METHODS: Cancer survivors participating in a 10-week supervised exercise program were included. The FitMáx©-questionnaire, DASI, VSAQ and a cardiopulmonary exercise test (CPET) were completed before (T0) and after (T1) the program. Intraclass correlation coefficients (ICC) were calculated between VO2peak estimated by the questionnaires (questionnaire-VO2peak) and VO2peak measured during CPET (CPET-VO2peak), at T0 to examine criterion validity, and between changes in questionnaire-VO2peak and CPET-VO2peak (ΔT0-T1) to determine responsiveness. Receiver operating characteristic (ROC) analyses were performed to examine the ability of the questionnaires to detect true improvements (≥ 6%) in CPET-VO2peak. RESULTS: Seventy participants were included. Outcomes at T1 were available for 58 participants (83%). Mean CPET-VO2peak significantly improved at T1 (Δ1.6 mL·kg- 1·min- 1 or 8%). Agreement between questionnaire-VO2peak and CPET-VO2peak at T0 was moderate for the FitMáx©-questionnaire (ICC = 0.69) and VSAQ (ICC = 0.53), and poor for DASI (ICC = 0.36). Poor agreement was found between ΔCPET-VO2peak and Δquestionnaire-VO2peak for all questionnaires (ICC 0.43, 0.19 and 0.18 for the FitMáx©-questionnaire, VSAQ and DASI, respectively). ROC analysis showed that the FitMáx©-questionnaire was able to detect improvements in CPET-VO2peak (area under the curve, AUC = 0.77), when using a cut-off value of 1.0 mL·kg- 1·min- 1, while VSAQ (AUC = 0.66) and DASI (AUC = 0.64) could not. CONCLUSION: The self-reported FitMáx©-questionnaire has sufficient validity to estimate aerobic capacity in cancer survivors at group level. The responsiveness of the FitMáx©-questionnaire for absolute change is limited, but the questionnaire is able to detect whether aerobic capacity improved. The FitMáx©-questionnaire showed substantial better values of validity and responsiveness compared to DASI and VSAQ.


Asunto(s)
Supervivientes de Cáncer , Neoplasias , Humanos , Autoinforme , Consumo de Oxígeno , Prueba de Esfuerzo , Encuestas y Cuestionarios , Neoplasias/terapia
4.
J Vasc Surg ; 78(2): 514-524.e2, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37060932

RESUMEN

OBJECTIVE: Endurance athletes such as cyclists may develop intermittent claudication owing to iliac artery endofibrosis after long-lasting extreme hemodynamic challenges. This study investigated short-term (<1.5 years) and long-term (>5 years) satisfaction and safety after a surgical endarterectomy and autologous patching. METHODS: Data of endurance athletes who underwent an endarterectomy for flow limitation of the iliac artery owing to endofibrosis between 1997 and 2015 in one center were studied. Maximal cycling exercise tests, ankle-brachial index with flexed hips, echo-Doppler examination (peak systolic velocity), and contrast-enhanced magnetic resonance angiography were performed before and 6 to 18 months after surgery. Short-term and long-term satisfaction were evaluated using questionnaires. Potential patch dilatation was assessed using echo-Doppler. RESULTS: Analysis of 68 patients (79 legs; 55.7% males, median age at the time of surgery, 34 years; interquartile range, 26-41 years) demonstrated that cycling workload at symptom onset improved from 226 ± 97 to 333 ± 101 (P < .001) Watts. Peak workload increased from 326 ± 111 to 352 ± 93 Watts (P < .001). Ankle-brachial index with flexed hips increased from 0.34 (interquartile range [IQR], 0.00-0.47) to 0.59 (IQR, 0.51-0.69; P < .001). Peak systolic velocity with extended and flexed hip decreased from 2.04 m·sec-1 (IQR, 1.52-2.56 m·3sec-1) to 1.25 m·sec-1 (IQR, 0.92-1.62 m·sec-1; P < .001) and 2.40 m·sec-1 (IQR, 1.81-2.81 m·sec-1) to 1.15 m·sec-1 (IQR, 0.97-1.60 m·sec-1; P < .001), respectively. Thirty-day major complication rate was 5.1% (hematoma requiring evacuation nLegs = 2, septic bleeding from deep infection nLegs = 1, and iliac occlusion requiring thrombectomy nLegs = 1). In the short term, 91.2% of patients reported symptom reduction with a 93.7% overall satisfaction rate. After a median of 11.1 years (IQR, 7.8-17.6 years), the overall satisfaction was 91.7%; 94.5% of patients reported persistent symptom reduction. Patch dilatation of >20 mm was observed in two patients. Linear mixed model analysis revealed no alarming patch dilatation in the long term. CONCLUSIONS: Endarterectomy with an autologous patch for intermittent claudication owing to iliac artery endofibrosis in endurance athletes shows high rates of patient satisfaction and symptom reduction in both the short and long term. The risk of surgical complications or patch dilatation is mild. A surgical intervention for flow limitation of the iliac artery owing to endofibrosis is safe and successful.


Asunto(s)
Arteria Ilíaca , Claudicación Intermitente , Masculino , Humanos , Adulto , Femenino , Claudicación Intermitente/diagnóstico por imagen , Claudicación Intermitente/etiología , Claudicación Intermitente/cirugía , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/cirugía , Arteria Ilíaca/patología , Fibrosis , Atletas , Endarterectomía/efectos adversos
5.
J Vasc Surg ; 77(2): 588-598.e3, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36334847

RESUMEN

OBJECTIVE: Endurance athletes are prone to develop flow limitations in iliac arteries (FLIA). Especially in cyclists and ice speed skaters, excessive hemodynamic loading coupled with hip hyperflexion may cause kinking in lengthened iliac arteries necessitating surgical correction. This study investigated the short-term (≤1.5 years) and long-term (≥5 years) satisfaction of operative shortening of the iliac artery in endurance athletes. METHODS: All patients who were diagnosed and operated for FLIA owing to lengthened and kinked iliac arteries between 1997 and 2015 in one center were analyzed. Short-term follow-up consisted of an incremental maximal cycling test, ankle-brachial index with flexed hips, echo-Doppler examination with peak systolic velocity measurements and contrast-enhanced magnetic resonance angiography before and 6 to 18 months after surgery. Both short- and long-term satisfaction were assessed using questionnaires. RESULTS: A total of 83 patients (90 operated legs; 96.7% males; median age of 34 years at the time of surgery; interquartile range [IQR], 29-47) were analyzed. In the short-term, 87.5% reported symptom reduction with an 86.4% overall satisfaction rate. Symptom-free cycling improved from 272 ± 84 W to 384 ± 101 W (P < .001), whereas the maximal workload increased from 419 ± 72 W to 428 ± 67 W (P = .01). The ankle-brachial index with flexed hips increased from 0.55 (IQR, 0.45-0.65) to 0.62 (IQR, 0.52-0.74; P = .008), and the peak systolic velocity measured with hips flexed decreased from 2.50 m/s (IQR, 1.77-3.13 m/s) to 1.57 m/s (IQR, 1.20-2.04 m/s; P < .001). After a median of 12 years (IQR, 9.0-15.4 years), symptoms were still decreased in 84.1% of patients with an 81.2% overall satisfaction rate (79.5% response rate). Three patients needed a reintervention (recurrent FLIA, n = 2; failure, n = 1). CONCLUSIONS: Operative shortening of a lengthened and kinked iliac artery causing FLIA is successful both in the short- and long-term.


Asunto(s)
Atletas , Arteria Ilíaca , Masculino , Humanos , Adulto , Femenino , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/cirugía , Arteria Ilíaca/patología , Angiografía por Resonancia Magnética , Pierna/irrigación sanguínea , Ciclismo
6.
J Clin Med ; 11(24)2022 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-36556078

RESUMEN

Background: A flow limitation in the iliac arteries (FLIA) in endurance athletes is notoriously difficult to diagnose with the currently available diagnostic tools. At present, a commonly used diagnostic measure is a decrease in ankle brachial index with flex hips (ABIFlexed) following a maximal effort exercise test. Near-infrared spectroscopy (NIRS) is a non-invasive technique that measures skeletal muscle oxygenation as reflected by the balance of O2 delivery from microvascular blood flow and O2 uptake by metabolic activity. Therefore, NIRS potentially serves as a novel technique for diagnosing FLIA. The purpose of this study is to compare the diagnostic accuracy of NIRS-derived absolute, amplitude, and kinetic variables in legs during and after a maximal exercise test with ABIFlexed. Methods: ABIFlexed and NIRS were studied in 33 healthy subjects and 201 patients with FLIA diagnosed with echo-Doppler. Results: After maximal exercise, NIRS kinetic variables, such as the half value time and mean response time, resulted in a range of 0.921 to 0.939 AUC for the diagnosis of FLIA when combined with ABIFlexed. Conversely, ABIFlexed measurements alone conferred significantly worse test characteristics (AUC 0.717, p < 0.001). Conclusions: NIRS may serve as a diagnostic adjunct in patients with possible FLIA.

7.
Int J Gen Med ; 15: 3727-3737, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35411174

RESUMEN

Purpose: Cardiorespiratory fitness (CRF) plays an essential role in health outcomes and quality of life. However, it is often not assessed nor estimated. Objective CRF assessment is costly, labour intensive and not widely available. Patient-reported outcome measures estimate CRF more cost-efficiently, but current questionnaires lack accuracy. The aim of this study is to develop a new self-reported questionnaire to estimate CRF. Materials and Methods: The FitMáx©-questionnaire, consisting of only three questions assessing walking, stair climbing, and cycling capacity, was compared with the commonly used Duke Activity Status Index (DASI) and Veterans Specific Activity Questionnaire (VSAQ). These questionnaires were compared to peak oxygen uptake (VO2peak) as measured with cardiopulmonary exercise testing. This study included 759 cardiac, pulmonary and oncologic patients and healthy persons aged 18‒90. Results: FitMáx© strongly correlated (r = 0.94 (0.92‒0.95) SEE = 4.14 mL∙kg-1∙min-1) with measured VO2peak. Bias between predicted and measured VO2peak was -0.24 (-9.23‒8.75; 95% limits of agreement) mL·kg-1·min-1. The FitMáx© scored superiorly on correlation and SEE compared with the DASI and VSAQ, r = 0.75 (0.68‒0.80) SEE = 4.62 mL∙kg-1∙min-1 and r = 0.87 (0.83‒0.90) SEE = 6.75 mL∙kg-1∙min-1, respectively. Conclusion: FitMáx© is a valid and accessible questionnaire to estimate CRF expressed as VO2peak in clinical practice and shows substantial improvement compared to currently used questionnaires.

8.
J Vasc Surg ; 75(6): 1993-2001.e3, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35085748

RESUMEN

OBJECTIVE: Endurance athletes can develop intermittent claudication due to sports-related flow limitations of the iliac artery (FLIA) caused by arterial kinking. In the present study, we investigated the short- and long-term efficacy of an operative release for iliac artery kinking. METHODS: Between 1996 and 2015, all patients with a diagnosis of FLIA due to iliac artery kinking without substantial arterial stenosis (<15%) or an excessive arterial length (vessel length to straight ratio, <1.25) who had undergone surgery were included. The short-term follow-up protocol consisted of cycling tests, the ankle brachial index with a flexed hip, and Doppler echography examinations to determine the peak systolic velocity before and 6 to 18 months after surgery. Additionally, the short- and long-term efficacy were evaluated using questionnaires. RESULTS: A total of 142 endurance athletes (155 legs; 88.4% male; median age, 26 years; interquartile range [IQR], 22-31 years) were available for analysis. In the short term, the symptoms had decreased in 83.9% of the patients, with an overall 80.3% satisfaction rate. Power during a maximal cycling test had improved from 420 W (IQR, 378-465 W) to 437 W (IQR, 392-485 W; P < .001). The symptom-free workload had increased from 300 W (IQR, 240-340 W) to 400 W (IQR, 330-448 W; P < .001). The postexercise ankle brachial index with a flexed hip had increased from 0.53 (IQR, 0.40-0.61) to 0.57 (IQR, 0.47-0.64; P = .002), and the peak systolic velocity with a flexed hip had decreased from 1.88 m/s (IQR, 1.45-2.50 m/s) to 1.52 m/s (IQR, 1.19-2.07 m/s; P < .001). Postoperative imaging studies revealed some degree kinking in 33.9%, mostly asymptomatic. The long-term results were evaluated after a median of 15.2 years (IQR, 10.9-19.5 years). The athletes had cycled an additional 125.500 km (IQR, 72.00-227.500 km), which was approximately equal to the 131.000 km (IQR, 98.250-220.000 km) cycled before the diagnosis of FLIA. On the long term, 63.9% of the athletes reported persistent reduction of complaints, with an overall 59.1% satisfaction rate. Eight patients had required reintervention, six because of treatment failure and two because of newly developed FLIA. CONCLUSIONS: Operative iliac artery release for sports-related functional kinking in the absence of stenosis or an excessive vessel length was effective for most athletes in the short and long term.


Asunto(s)
Arteria Ilíaca , Resistencia Física , Adulto , Atletas , Constricción Patológica/complicaciones , Femenino , Humanos , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/cirugía , Claudicación Intermitente/diagnóstico por imagen , Claudicación Intermitente/etiología , Claudicación Intermitente/cirugía , Masculino , Resultado del Tratamiento , Adulto Joven
9.
Clin Physiol Funct Imaging ; 42(2): 114-126, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35075811

RESUMEN

The ankle-brachial index is an accurate tool for detecting claudication in atherosclerotic patients. However, this technique fails to identify subtle flow limitations of the iliac arteries (FLIA) in endurance athletes. Near-infrared spectroscopy (NIRS) is a noninvasive technique that measures skeletal muscle tissue oxygenation status. The aim of the present study is to examine the absolute and relative test-retest reliability of NIRS and evaluate its potential as a diagnostic tool in FLIA. NIRS-derived exercise variables were analyzed during exercise and recovery in FLIA 17 patients and 19 healthy controls. The relative reliability of absolute variables (such as the maximal value) were slight to yet predominantly substantial (intraclass correlation coefficient [ICC], ICC range: 0.06-0.76) with good to excellent absolute reliability (absolute limits of agreement [ALoA], ALoA range: 0.8 ± 10.2 to 0.7 ± 13.1; coefficient of variation [CV], CV range: 5%-11%). Absolute values encompassing signal amplitudes showed moderate to almost perfect relative reliability (ICC range: 0.51-0.89) and poor to good absolute reliability (ALoA range: -1.3 ± 7.0 to -2.5 ± 15.7; CV range: 15%-32%). Kinetic variables showed moderate to almost perfect relative reliability for most recovery kinetics variables (ICC range: 0.54-0.86) with fair to good absolute reliability (ALoA range: 0.4 ± 12.2 to 3.9 ± 37.9; CV range: 18%-27%). Particularly, kinetic variables showed significant differences between patients and healthy subjects. NIRS is found to be a reliable method for examining muscle tissue oxygenation variables. Given the significant differences in especially recovery kinetics between normal subjects and patients, NIRS may contribute to diagnosing FLIA in endurance athletes.


Asunto(s)
Arteria Ilíaca , Espectroscopía Infrarroja Corta , Ejercicio Físico , Prueba de Esfuerzo , Humanos , Arteria Ilíaca/diagnóstico por imagen , Músculo Esquelético , Reproducibilidad de los Resultados
10.
Phys Sportsmed ; 49(2): 241-244, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-32713244

RESUMEN

OBJECTIVES: Approximately one in five professional cycling athletes will eventually develop a sport-related vascular problem. However, detecting such flow limitation is a diagnostic challenge as the sensitivity of the currently available standard diagnostic tools is limited. METHODS: Here we present an athlete with exercise-induced pain and weakness of the left leg. During the physical examination, pulsations of the femoral artery were palpable but less prominent. He was analyzed in an ongoing research project aimed at improving methods detecting sport-related leg flow limitations. RESULTS: During functional testing, the ankle-brachial index of the left leg was moderately lowered. However, results of near-infrared spectroscopy and pedal power measurements were largely abnormal suggesting a severe flow limitation. CONCLUSION: Combining post-exercise ankle-brachial index, near-infrared spectroscopy, and pedal power measurements as routine diagnostic functional testing suggested a severe arterial flow inflow limitation. Conventional diagnostics encompassing duplex-Doppler echography and magnetic resonance angiography confirmed a femoral artery occlusion. CLINICAL TRIAL REGISTRATION: https://www.trialregister.nl/ identifier is Trial NL8557.Abbreviations: NIRS: Near-Infrared Spectroscopy; PPM: Pedal Power Measurements; ABI: Ankle Brachial Index; PSV: Peak Systolic Velocity.


Asunto(s)
Enfermedad Arterial Periférica , Espectroscopía Infrarroja Corta , Índice Tobillo Braquial , Arteria Femoral/diagnóstico por imagen , Pie , Humanos , Masculino
11.
JMIR Mhealth Uhealth ; 7(12): e15045, 2019 12 19.
Artículo en Inglés | MEDLINE | ID: mdl-31855191

RESUMEN

BACKGROUND: Improving physical activity (PA) is a core component of secondary prevention and cardiac (tele)rehabilitation. Commercially available activity trackers are frequently used to monitor and promote PA in cardiac patients. However, studies on the validity of these devices in cardiac patients are scarce. As cardiac patients are being advised and treated based on PA parameters measured by these devices, it is highly important to evaluate the accuracy of these parameters in this specific population. OBJECTIVE: The aim of this study was to determine the accuracy and responsiveness of 2 wrist-worn activity trackers, Fitbit Charge 2 (FC2) and Mio Slice (MS), for the assessment of energy expenditure (EE) in cardiac patients. METHODS: EE assessed by the activity trackers was compared with indirect calorimetry (Oxycon Mobile [OM]) during a laboratory activity protocol. Two groups were assessed: patients with stable coronary artery disease (CAD) with preserved left ventricular ejection fraction (LVEF) and patients with heart failure with reduced ejection fraction (HFrEF). RESULTS: A total of 38 patients were included: 19 with CAD and 19 with HFrEF (LVEF 31.8%, SD 7.6%). The CAD group showed no significant difference in total EE between FC2 and OM (47.5 kcal, SD 112 kcal; P=.09), in contrast to a significant difference between MS and OM (88 kcal, SD 108 kcal; P=.003). The HFrEF group showed significant differences in EE between FC2 and OM (38 kcal, SD 57 kcal; P=.01), as well as between MS and OM (106 kcal, SD 167 kcal; P=.02). Agreement of the activity trackers was low in both groups (CAD: intraclass correlation coefficient [ICC] FC2=0.10, ICC MS=0.12; HFrEF: ICC FC2=0.42, ICC MS=0.11). The responsiveness of FC2 was poor, whereas MS was able to detect changes in cycling loads only. CONCLUSIONS: Both activity trackers demonstrated low accuracy in estimating EE in cardiac patients and poor performance to detect within-patient changes in the low-to-moderate exercise intensity domain. Although the use of activity trackers in cardiac patients is promising and could enhance daily exercise behavior, these findings highlight the need for population-specific devices and algorithms.


Asunto(s)
Ejercicio Físico/fisiología , Monitores de Ejercicio/estadística & datos numéricos , Cardiopatías/fisiopatología , Monitoreo Fisiológico/instrumentación , Anciano , Calorimetría Indirecta/estadística & datos numéricos , Estudios de Casos y Controles , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/fisiopatología , Metabolismo Energético/fisiología , Femenino , Monitores de Ejercicio/provisión & distribución , Cardiopatías/diagnóstico , Cardiopatías/epidemiología , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Volumen Sistólico , Estudios de Validación como Asunto , Función Ventricular Izquierda/fisiología , Dispositivos Electrónicos Vestibles/estadística & datos numéricos , Dispositivos Electrónicos Vestibles/tendencias
12.
Clin Biomech (Bristol, Avon) ; 61: 211-216, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30597482

RESUMEN

BACKGROUND: Cyclists with flow limitations in the iliac arteries complain of pain and loss of power. To investigate whether pedal power measurement has added value in diagnosing the underlying cause of flow limitations in the iliac arteries, we explored the sensitivity and specificity of various pedal power measurement variables. Moreover, it was assessed what the added value of pedal power measurement is compared to diagnosis based on the conventional ankle-brachial blood pressure index. METHODS: 25 healthy participants and 45 patients with unilateral arterial flow limitations were recruited. Participants received Echo-Doppler examination to determine the condition of the iliac arteries. Subsequently, participants performed a maximal cycle ergometer test. During the cycling test the exerted left and right pedal power was measured. From these measurements several variables were derived to diagnose arterial flow limitations. A receiver operating characteristics curve based on a predicted cross-validated model was used to select the variable with the highest predictive value and its cut-off value. FINDINGS: The mean power difference between both legs relative to the exerted power at 95% of the maximal power showed the best predictive value with a sensitivity of 0.76 and a specificity of 0.88. Combining the pedal power measurement and ankle-brachial blood pressure index resulted in a sensitivity of 0.91 and a specificity of 0.88. INTERPRETATION: Pedal power measurement improves sensitivity of diagnosis of iliac artery flow limitations, without increasing the burden of clinical investigation to the patients.


Asunto(s)
Ciclismo/lesiones , Prueba de Esfuerzo , Arteria Ilíaca/fisiopatología , Enfermedades Vasculares/diagnóstico , Adulto , Anciano , Índice Tobillo Braquial , Estudios de Casos y Controles , Femenino , Pie/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Curva ROC , Reología , Sensibilidad y Especificidad , Enfermedades Vasculares/fisiopatología , Adulto Joven
13.
J Sports Med (Hindawi Publ Corp) ; 2018: 8965858, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30671480

RESUMEN

Endurance cyclists have a substantial risk to develop flow limitations in the iliac arteries during their career. These flow limitations are due to extreme hemodynamic stress which may result in functional arterial kinking and/or intravascular lesions. Early diagnosis may improve outcome and could prevent the necessity for surgical vascular repair. However, current diagnostic techniques have unsatisfactory sensitivity and cannot be applied during exercise. Near-infrared spectroscopy (NIRS) has shown great diagnostic potential in peripheral vascular disease and might bring a solution since it measures tissue oxygenation in real time during and after exercise. This report describes the first experiences of the application of NIRS in the vastus lateralis muscle during and after maximal graded cycling exercise in ten healthy participants and in three patients with flow limitations due to (1) subtle functional kinking, (2) an intravascular lesion, and (3) severe functional kinking. The results are put into perspective based on an empirically fitted model. Delayed recovery, showing clearly different types of patterns of tissue reoxygenation after exercise, was found in the affected athletes compared with the healthy participants. In the patients that had kinking of the arteries, tissue reoxygenation was clearly more delayed if NIRS was measured in provocative position with flexed hip. In this pilot experiment, clearly distinctive reoxygenation patterns are observed during recovery consistent with severity of flow limitation, indicating that NIRS is a promising diagnostic tool to detect and grade arterial flow limitations in athletes. Our findings may guide research and optimization of NIRS for future clinical application.

SELECCIÓN DE REFERENCIAS