Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
BMJ Open ; 14(5): e081561, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38729756

RESUMEN

INTRODUCTION: Twin pregnancies have a high risk of extreme preterm birth (PTB) at less than 28 weeks of gestation, which is associated with increased risk of neonatal morbidity and mortality. Currently there is a lack of effective treatments for women with a twin pregnancy and a short cervix or cervical dilatation. A possible effective surgical method to reduce extreme PTB in twin pregnancies with an asymptomatic short cervix or dilatation at midpregnancy is the placement of a vaginal cerclage. METHODS AND ANALYSIS: We designed two multicentre randomised trials involving eight hospitals in the Netherlands (sites in other countries may be added at a later date). Women older than 16 years with a twin pregnancy at <24 weeks of gestation and an asymptomatic short cervix of ≤25 mm or cervical dilatation will be randomly allocated (1:1) to both trials on vaginal cerclage and standard treatment according to the current Dutch Society of Obstetrics and Gynaecology guideline (no cerclage). Permuted blocks sized 2 and 4 will be used to minimise the risk of disbalance. The primary outcome measure is PTB of <28 weeks. Analyses will be by intention to treat. The first trial is to demonstrate a risk reduction from 25% to 10% in the short cervix group, for which 194 patients need to be recruited. The second trial is to demonstrate a risk reduction from 80% to 35% in the dilatation group and will recruit 44 women. A cost-effectiveness analysis will be performed from a societal perspective. ETHICS AND DISSEMINATION: This study has been approved by the Research Ethics Committees in the Netherlands on 3/30/2023. Participants will be required to sign an informed consent form. The results will be presented at conferences and published in a peer-reviewed journal. Participants will be informed about the results. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov, NCT05968794.


Asunto(s)
Cerclaje Cervical , Mortalidad Perinatal , Embarazo Gemelar , Nacimiento Prematuro , Ensayos Clínicos Controlados Aleatorios como Asunto , Humanos , Femenino , Embarazo , Cerclaje Cervical/métodos , Nacimiento Prematuro/prevención & control , Países Bajos , Recién Nacido , Estudios Multicéntricos como Asunto , Cuello del Útero/cirugía , Adulto
2.
PLoS One ; 19(4): e0302123, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38630708

RESUMEN

BACKGROUND: Fetal two-dimensional speckle tracking echocardiography (2D-STE) is an emerging technique for assessing fetal cardiac function by measuring global longitudinal strain. Alterations in global longitudinal strain may serve as early indicator of pregnancy complications, making 2D-STE a potentially valuable tool for early detection. Early detection can facilitate timely interventions to reduce fetal and maternal morbidity and mortality. Therefore, the aim of this study was to investigate the feasibility of performing 2D-STE at 16 weeks gestational age. METHODS: This pilot study utilized 50 ultrasound clips of the fetal four-chamber view recorded between 15+5 and 16+2 weeks gestational age from a prospective cohort study. A strict protocol assessed three parameters essential for 2D-STE analysis: fetal four-chamber view ultrasound clip quality, region of interest, and frame rates. Two independent researchers measured global longitudinal strain in all adequate fetal four-chamber view ultrasound clips to determine inter- and intra-operator reliability. RESULTS: Out of the 50 ultrasound clips, 37 (74%) were feasible for 2D-STE analysis. The inter-operator reliability for global longitudinal strain measurements of the left and right ventricles was moderate (ICC of 0.64 and 0.74, respectively), while the intra-operator reliability was good (ICC of 0.76 and 0.79, respectively). CONCLUSIONS: Our findings demonstrate that fetal 2D-STE analysis at 16 weeks gestational age is feasible when adhering to a strict protocol. However, further improvements are necessary to enhance the inter- and intra-operator reliability of 2D-STE at this gestational age.


Asunto(s)
Ecocardiografía Tridimensional , Ecocardiografía , Embarazo , Femenino , Humanos , Edad Gestacional , Proyectos Piloto , Reproducibilidad de los Resultados , Estudios de Factibilidad , Estudios Prospectivos , Ecocardiografía/métodos , Ventrículos Cardíacos , Ecocardiografía Tridimensional/métodos
3.
J Clin Med ; 13(8)2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38673715

RESUMEN

Background: Owing to the association between dysfunctional maternal autonomic regulation and pregnancy complications, assessing non-invasive features reflecting autonomic activity-e.g., heart rate variability (HRV) and the morphology of the photoplethysmography (PPG) pulse wave-may aid in tracking maternal health. However, women with early pregnancy complications typically receive medication, such as corticosteroids, and the effect of corticosteroids on maternal HRV and PPG pulse wave morphology is not well-researched. Methods: We performed a prospective, observational study assessing the effect of betamethasone (a commonly used corticosteroid) on non-invasively assessed features of autonomic regulation. Sixty-one women with an indication for betamethasone were enrolled and wore a wrist-worn PPG device for at least four days, from which five-minute measurements were selected for analysis. A baseline measurement was selected either before betamethasone administration or sufficiently thereafter (i.e., three days after the last injection). Furthermore, measurements were selected 24, 48, and 72 h after betamethasone administration. HRV features in the time domain and frequency domain and describing heart rate (HR) complexity were calculated, along with PPG morphology features. These features were compared between the different days. Results: Maternal HR was significantly higher and HRV features linked to parasympathetic activity were significantly lower 24 h after betamethasone administration. Features linked to sympathetic activity remained stable. Furthermore, based on the PPG morphology features, betamethasone appears to have a vasoconstrictive effect. Conclusions: Our results suggest that administering betamethasone affects maternal autonomic regulation and cardiovasculature. Researchers assessing maternal HRV in complicated pregnancies should schedule measurements before or sufficiently after corticosteroid administration.

4.
Front Pediatr ; 12: 1360111, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38425664

RESUMEN

To improve care for extremely premature infants, the development of an extrauterine environment for newborn development is being researched, known as Artificial Placenta and Artificial Womb (APAW) technology. APAW facilitates extended development in a liquid-filled incubator with oxygen and nutrient supply through an oxygenator connected to the umbilical vessels. This setup is intended to provide the optimal environment for further development, allowing further lung maturation by delaying gas exposure to oxygen. This innovative treatment necessitates interventions in obstetric procedures to transfer an infant from the native to an artificial womb, while preventing fetal-to-neonatal transition. In this narrative review we analyze relevant fetal physiology literature, provide an overview of insights from APAW studies, and identify considerations for the obstetric procedure from the native uterus to an APAW system. Lastly, this review provides suggestions to improve sterility, fetal and maternal well-being, and the prevention of neonatal transition.

5.
Acta Obstet Gynecol Scand ; 102(11): 1511-1520, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37563851

RESUMEN

INTRODUCTION: This study aims to investigate non-invasive electrocardiography as a method for the detection of congenital heart disease (CHD) with the help of artificial intelligence. MATERIAL AND METHODS: An artificial neural network was trained for the identification of CHD using non-invasively obtained fetal electrocardiograms. With the help of a Bayesian updating rule, multiple electrocardiographs were used to increase the algorithm's performance. RESULTS: Using 122 measurements containing 65 healthy and 57 CHD cases, the accuracy, sensitivity, and specificity were found to be 71%, 63%, and 77%, respectively. The sensitivity was however 75% and 69% for CHD cases requiring an intervention in the neonatal period and first year of life, respectively. Furthermore, a positive effect of measurement length on the detection performance was observed, reaching optimal performance when using 14 electrocardiography segments (37.5 min) or more. A small negative trend between gestational age and accuracy was found. CONCLUSIONS: The proposed method combining recent advances in obtaining non-invasive fetal electrocardiography with artificial intelligence for the automatic detection of CHD achieved a detection rate of 63% for all CHD and 75% for critical CHD. This feasibility study shows that detection rates of CHD might improve by using electrocardiography-based screening complementary to the standard ultrasound-based screening. More research is required to improve performance and determine the benefits to clinical practice.


Asunto(s)
Inteligencia Artificial , Cardiopatías Congénitas , Embarazo , Femenino , Recién Nacido , Humanos , Teorema de Bayes , Ultrasonografía Prenatal/métodos , Cardiopatías Congénitas/diagnóstico por imagen , Electrocardiografía , Corazón Fetal/diagnóstico por imagen
6.
PLoS One ; 18(7): e0287245, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37437012

RESUMEN

BACKGROUND: Researchers have long suspected a mutual interaction between maternal and fetal heart rhythms, referred to as maternal-fetal cardiac coupling (MFCC). While several studies have been published on this phenomenon, they vary in terms of methodologies, populations assessed, and definitions of coupling. Moreover, a clear discussion of the potential clinical implications is often lacking. Subsequently, we perform a scoping review to map the current state of the research in this field and, by doing so, form a foundation for future clinically oriented research on this topic. METHODS: A literature search was performed in PubMed, Embase, and Cochrane. Filters were only set for language (English, Dutch, and German literature were included) and not for year of publication. After screening for the title and the abstract, a full-text evaluation of eligibility followed. All studies on MFCC were included which described coupling between heart rate measurements in both the mother and fetus, regardless of the coupling method used, gestational age, or the maternal or fetal health condition. RESULTS: 23 studies remained after a systematic evaluation of 6,672 studies. Of these, 21 studies found at least occasional instances of MFCC. Methods used to capture MFCC are synchrograms and corresponding phase coherence indices, cross-correlation, joint symbolic dynamics, transfer entropy, bivariate phase rectified signal averaging, and deep coherence. Physiological pathways regulating MFCC are suggested to exist either via the autonomic nervous system or due to the vibroacoustic effect, though neither of these suggested pathways has been verified. The strength and direction of MFCC are found to change with gestational age and with the rate of maternal breathing, while also being further altered in fetuses with cardiac abnormalities and during labor. CONCLUSION: From the synthesis of the available literature on MFCC presented in this scoping review, it seems evident that MFCC does indeed exist and may have clinical relevance in tracking fetal well-being and development during pregnancy.


Asunto(s)
Relevancia Clínica , Feto , Femenino , Embarazo , Humanos , Atención Prenatal , Corazón , Edad Gestacional
7.
PLoS One ; 18(7): e0287003, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37437044

RESUMEN

OBJECTIVES: Two-dimensional speckle tracking echocardiography has been considered an angle-independent modality. However, current literature is limited and inconclusive on the actual impact of angle of insonation on strain values. Therefore, the primary objective of this study was to assess the impact of angles of insonation on the estimation of fetal left ventricular and right ventricular global longitudinal strain. Secondarily, the impact of different definitions for angles of insonation was investigated in a sensitivity analysis. METHODS: This is a retrospective analysis of a prospective longitudinal cohort study with 124 healthy subjects. The analyses were based on the four-chamber view ultrasound clips taken between 18+0 and 21+6 weeks of gestation. Angles of insonation were categorized into three groups: up/down, oblique and perpendicular. The mean fetal left and right ventricular and global longitudinal strain values corresponding to these three groups were compared by an ANOVA test corrected for heteroscedasticity. RESULTS: Fetal left and right ventricular global longitudinal strain values were not statistically different between the three angles of insonation (p-value >0.062 and >0.149, respectively). When applying another definition for angles of insonation in the sensitivity analysis, the mean left ventricular global longitudinal strain value was significantly decreased for the oblique compared to the up/down angle of insonation (p-value 0.041). CONCLUSIONS: There is no evidence of a difference in fetal left and right ventricular global longitudinal strain between the different angles of insonation in fetal two-dimensional speckle tracking echocardiography.


Asunto(s)
Ecocardiografía , Tensión Longitudinal Global , Humanos , Estudios Longitudinales , Estudios Prospectivos , Estudios Retrospectivos
8.
Acta Obstet Gynecol Scand ; 102(7): 865-872, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37170633

RESUMEN

INTRODUCTION: Fetal electrocardiography (NI-fECG) and electrohysterography (EHG) have been proven more accurate and reliable than conventional non-invasive methods (doppler ultrasound and tocodynamometry) and are less affected by maternal obesity. It is still unknown whether NI-fECG and EHG will eliminate the need for invasive methods, such as the intrauterine pressure catheter and fetal scalp electrode. We studied whether NI-fECG and EHG can be successfully used during labor. MATERIAL AND METHODS: A prospective clinical pilot study was performed in a tertiary care teaching hospital. A total of 50 women were included with a singleton pregnancy with a gestational age between 36+0 and 42+0 weeks and had an indication for continuous intrapartum monitoring. The primary study outcome was the percentage of women with NI-fECG and EHG monitoring throughout the whole delivery. Secondary study outcomes were reason and timing of a switch to conventional monitoring methods (i.e., tocodynamometry and fetal scalp electrode or doppler ultrasound), repositioning of the abdominal electrode patch, success rates (i.e., the percentage of time with signal output), and obstetric and neonatal outcomes. CLINICAL TRIAL REGISTRATION: Dutch trial register (NL8024). RESULTS: In 45 women (90%), NI-fECG and EHG monitoring was used throughout the whole delivery. In the other five women (10%), there was a switch to conventional methods: in two women because of insufficient registration quality of uterine contractions and in three women because of insufficient registration quality of the fetal heart rate. In three out of five cases, the switch was after full dilation was reached. Repositioning of the abdominal electrode patch occurred in two women. The overall success rate was 94.5%. In 16% (n = 8) of women, a cesarean delivery was performed due to non-progressing dilation (n = 7) and due to suspicion of fetal distress (n = 1). Neonatal metabolic acidosis did not occur. Two neonates (4%) were admitted to the neonatal intensive care unit for complications not related to intrapartum monitoring. CONCLUSIONS: NI-fECG and EHG can be successfully used during labor in 90% of women. Future research is needed to conclude whether implementation of electrophysiological monitoring can improve obstetric and neonatal outcomes.


Asunto(s)
Trabajo de Parto , Femenino , Humanos , Recién Nacido , Embarazo , Electrocardiografía , Trabajo de Parto/fisiología , Proyectos Piloto , Estudios Prospectivos , Contracción Uterina
9.
Eur J Obstet Gynecol Reprod Biol ; 283: 59-67, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36796129

RESUMEN

OBJECTIVE: To develop and internally validate a prognostic prediction model for development of a niche in the uterine scar after a first caesarean section (CS). STUDY DESIGN: Secondary analyses on data of a randomized controlled trial, performed in 32 hospitals in the Netherlands among women undergoing a first caesarean section. We used multivariable backward logistic regression. Missing data were handled using multiple imputation. Model performance was assessed by calibration and discrimination. Internal validation using bootstrapping techniques took place. The outcome was 'development of a niche in the uterus', defined as an indentation of ≥ 2 mm in the myometrium. RESULTS: We developed two models to predict niche development: in the total population and after elective CS. Patient related risk factors were: gestational age, twin pregnancy and smoking, and surgery related risk factors were double-layer closure and less surgical experience. Multiparity and Vicryl suture material were protective factors. The prediction model in women undergoing elective CS revealed similar results. After internal validation, Nagelkerke R2 ranged from 0.01 to 0.05 and was considered low; median area under the curve (AUC) ranged from 0.56 to 0.62, indicating failed to poor discriminative ability. CONCLUSIONS: The model cannot be used to accurately predict the development of a niche after a first CS. However, several factors seem to influence scar healing which indicates possibilities for future prevention such as surgical experience and suture material. The search for additional risk factors that play a role in development of a niche should be continued to improve the discriminative ability.


Asunto(s)
Cesárea , Cicatriz , Femenino , Embarazo , Humanos , Cesárea/efectos adversos , Cesárea/métodos , Cicatriz/etiología , Pronóstico , Útero/cirugía , Miometrio/patología
10.
J Clin Med ; 12(2)2023 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-36675517

RESUMEN

While the effect of antenatally administered corticosteroids on fetal heart rate (HR) and heart rate variability (HRV) is well established, little information is available on how these drugs affect maternal physiology. In this secondary analysis of a prospective, observational cohort study, we quantify how corticosteroids affect maternal HR and HRV, which serve as a proxy measure for autonomic regulation. Abdominal ECG measurements were recorded before and in the five days following the administration of betamethasone­a corticosteroid commonly used for fetal maturation­in 46 women with singleton pregnancies. Maternal HR and HRV were determined from these recordings and compared between these days. HRV was assessed with time- and frequency-domain features, as well as non-linear and complexity features. In the 24 h after betamethasone administration, maternal HR was significantly increased (p < 0.01) by approximately 10 beats per minute, while HRV features linked to parasympathetic activity and HR complexity were significantly decreased (p < 0.01 and p < 0.001, respectively). Within four days after the initial administration of betamethasone, HR decreases and HRV features increase again, indicating a diminishing effect of betamethasone a few days after administration. We conclude that betamethasone administration results in changes in maternal HR and HRV, despite the heterogeneity of the studied population. Therefore, its recent administration should be considered when evaluating these cardiovascular metrics.

11.
Eur J Obstet Gynecol Reprod Biol ; 278: 159-165, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36208521

RESUMEN

INTRODUCTION: Worldwide, cardiotocography is used for continuous monitoring of fetal heart rate (FHR) and uterine contractions during labour. Different methods for FHR registration and registration of contractions are available. Literature about the frequency of use of different fetal monitoring methods is lacking. OBJECTIVE: To evaluate the use of and preferences for fetal monitoring methods for intrapartum fetal monitoring among Dutch obstetric care providers. STUDY DESIGN: Between October and November 2020 the Dutch Society of Obstetrics and Gynaecology sent an email invitation to all secondary care midwives and gynaecologists (in training) in the Netherlands to complete an online survey regarding the use and personal experience with fetal monitoring methods. The survey mainly consisted of multiple choice questions. Descriptive statistics are reported. Continuous variables were presented as median with interquartile ranges (IQR). Categorical variables were expressed as numbers with percentages. RESULTS: The response rate was 29 % (n/N = 510/1748). All Dutch hospitals were represented. The respondents estimated the use of fetal scalp electrode (FSE) at 71 % (IQR 58-85 %) of deliveries. The most common indication for use of the FSE was inadequate external FHR registration (94 %). More than half (54 %) of the respondents reported to use intrauterine pressure catheter with an estimated use of 5 % (IQR 2-8 %) of deliveries. The most common indication for use of intrauterine pressure catheter was inadequate external contraction registration (75 %). The use of ST-analysis was reported in 25 % of the respondents with an estimated use of 60 % (IQR 30-72 %) of deliveries. Almost all respondents (99 %) reported to use fetal blood sampling with an estimated use of 15 % (IQR 10-23 %) of deliveries. Ninety percent of respondents would prefer a valid and reliable external monitoring technique during labour. Thirty-one percent of respondents assume that external fetal monitoring with non-invasive fetal electrocardiography and electrohysterography will become standard care within the next 5 years. CONCLUSIONS: Currently, the FSE is the most used technique for FHR monitoring during labour in the Netherlands. The most common indication for use of FSE is inadequate external FHR registration. Obstetric care providers would prefer a non-invasive external registration method that provides reliable data.


Asunto(s)
Cardiotocografía , Trabajo de Parto , Embarazo , Femenino , Humanos , Países Bajos , Cardiotocografía/métodos , Frecuencia Cardíaca Fetal/fisiología , Monitoreo Fetal/métodos , Trabajo de Parto/fisiología , Encuestas y Cuestionarios
12.
J Matern Fetal Neonatal Med ; 35(25): 10055-10063, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35726837

RESUMEN

OBJECTIVE: To determine the prevalence of depression, anxiety, and posttraumatic stress disorder (PTSD) years after hyperemesis gravidarum (HG) and its association with HG severity. MATERIAL AND METHODS: This prospective cohort study consisted of a follow-up of 215 women admitted for HG, who were eligible to participate in a randomized controlled trial and either declined or agreed to be randomized between 2013 and 2016 in 19 hospitals in the Netherlands. Participants completed the Hospital Anxiety and Depression Scale (HADS) six weeks postpartum and during follow-up and the PTSD checklist for DSM-5 (PCL-5) during follow-up. An anxiety or depression score ≥8 is indicative of an anxiety or depression disorder and a PCL-5 ≥ 31 indicative of PTSD. Measures of HG severity were symptom severity (PUQE-24: Pregnancy Unique Quantification of Emesis), weight change, duration of admissions, readmissions, and admissions after the first trimester. RESULTS: About 54/215 participants completed the HADS six weeks postpartum and 73/215 participants completed the follow-up questionnaire, on average 4.5 years later. Six weeks postpartum, 13 participants (24.1%) had an anxiety score ≥8 and 11 participants (20.4%) a depression score ≥8. During follow-up, 29 participants (39.7%) had an anxiety score ≥8, 20 participants (27.4%) a depression score ≥8, and 16 participants (21.9%) a PCL-5 ≥ 31.Multivariable logistic regression analysis showed that for every additional point of the mean PUQE-24 three weeks after inclusion, the likelihood of having an anxiety score ≥8 and PCL-5 ≥ 31 at follow-up increased with OR 1.41 (95% CI: 1.10;1.79) and OR 1.49 (95% CI: 1.06;2.10) respectively. CONCLUSION: Depression, anxiety, and PTSD symptoms are common years after HG occurred.


Asunto(s)
Hiperemesis Gravídica , Trastornos por Estrés Postraumático , Embarazo , Femenino , Humanos , Hiperemesis Gravídica/complicaciones , Hiperemesis Gravídica/epidemiología , Trastornos por Estrés Postraumático/epidemiología , Trastornos por Estrés Postraumático/etiología , Depresión/etiología , Depresión/complicaciones , Estudios Prospectivos , Ansiedad/etiología , Ansiedad/complicaciones
13.
Front Physiol ; 13: 874684, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35615673

RESUMEN

Changes in the maternal autonomic nervous system are essential in facilitating the physiological changes that pregnancy necessitates. Insufficient autonomic adaptation is linked to complications such as hypertensive diseases of pregnancy. Consequently, tracking autonomic modulation during progressing pregnancy could allow for the early detection of emerging deteriorations in maternal health. Autonomic modulation can be longitudinally and unobtrusively monitored by assessing heart rate variability (HRV). Yet, changes in maternal HRV (mHRV) throughout pregnancy remain poorly understood. In previous studies, mHRV is typically assessed only once per trimester with standard HRV features. However, since gestational changes are complex and dynamic, assessing mHRV comprehensively and more frequently may better showcase the changing autonomic modulation over pregnancy. Subsequently, we longitudinally (median sessions = 8) assess mHRV in 29 healthy pregnancies with features that assess sympathetic and parasympathetic activity, as well as heart rate (HR) complexity, HR responsiveness and HR fragmentation. We find that vagal activity, HR complexity, HR responsiveness, and HR fragmentation significantly decrease. Their associated effect sizes are small, suggesting that the increasing demands of advancing gestation are well tolerated. Furthermore, we find a notable change in autonomic activity during the transition from the second to third trimester, highlighting the dynamic nature of changes in pregnancy. Lastly, while we saw the expected rise in mean HR with gestational age, we also observed increased autonomic deceleration activity, seemingly to counter this rising mean HR. These results are an important step towards gaining insights into gestational physiology as well as tracking maternal health via mHRV.

15.
Br J Nutr ; 128(12): 2421-2431, 2022 12 28.
Artículo en Inglés | MEDLINE | ID: mdl-35197140

RESUMEN

This study aimed to investigate the association between hyperemesis gravidarum (HG) severity and early enteral tube feeding on cardiometabolic markers in offspring cord blood. We included women admitted for HG, who participated in the MOTHER randomised controlled trial (RCT) and observational cohort. The MOTHER RCT showed that early enteral tube feeding in addition to standard care did not affect symptoms/birth outcomes. Among RCT and cohort participants, we assessed how HG severity affected lipid, c-peptide, glucose and free thyroxine cord blood levels. HG severity measures were severity of vomiting at inclusion and 3 weeks after inclusion, pregnancy weight gain and 24-h energy intake at inclusion, readmissions and duration of hospital admissions. Cord blood measures were also compared between RCT participants allocated to enteral tube feeding and those receiving standard care. Between 2013-2016, 215 women were included: 115 RCT and 100 cohort participants. Eighty-one cord blood samples were available. Univariable not multivariable regression analysis showed that lower maternal weight gain was associated with higher cord blood glucose levels (ß: -0·08, 95% CI -0·16, -0·00). Lower maternal weight gain was associated with higher Apo-B cord blood levels in multivariable regression analysis (ß: -0·01, 95% CI -0·02, -0·01). No associations were found between other HG severity measures or allocation to enteral tube feeding and cord blood cardiometabolic markers. In conclusion, while lower maternal weight gain was associated with higher Apo-B cord blood levels, no other HG severity measures were linked with cord blood cardiometabolic markers, nor were these markers affected by enteral tube feeding.


Asunto(s)
Enfermedades Cardiovasculares , Ganancia de Peso Gestacional , Hiperemesis Gravídica , Embarazo , Femenino , Humanos , Nutrición Enteral , Sangre Fetal
16.
PLoS Med ; 19(2): e1003892, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-35104279

RESUMEN

BACKGROUND: Preterm birth is the leading cause of neonatal morbidity and mortality. The recurrence rate of spontaneous preterm birth is high, and additional preventive measures are required. Our objective was to assess the effectiveness of low-dose aspirin compared to placebo in the prevention of preterm birth in women with a previous spontaneous preterm birth. METHODS AND FINDINGS: We performed a parallel multicentre, randomised, double-blinded, placebo-controlled trial (the APRIL study). The study was performed in 8 tertiary and 26 secondary care hospitals in the Netherlands. We included women with a singleton pregnancy and a history of spontaneous preterm birth of a singleton between 22 and 37 weeks. Participants were randomly assigned to aspirin 80 mg daily or placebo initiated between 8 and 16 weeks of gestation and continued until 36 weeks or delivery. Randomisation was computer generated, with allocation concealment by using sequentially numbered medication containers. Participants, their healthcare providers, and researchers were blinded for treatment allocation. The primary outcome was preterm birth <37 weeks of gestation. Secondary outcomes included a composite of poor neonatal outcome (bronchopulmonary dysplasia, periventricular leukomalacia > grade 1, intraventricular hemorrhage > grade 2, necrotising enterocolitis > stage 1, retinopathy of prematurity, culture proven sepsis, or perinatal death). Analyses were performed by intention to treat. From May 31, 2016 to June 13, 2019, 406 women were randomised to aspirin (n = 204) or placebo (n = 202). A total of 387 women (81.1% of white ethnic origin, mean age 32.5 ± SD 3.8) were included in the final analysis: 194 women were allocated to aspirin and 193 to placebo. Preterm birth <37 weeks occurred in 41 (21.2%) women in the aspirin group and 49 (25.4%) in the placebo group (relative risk (RR) 0.83, 95% confidence interval (CI) 0.58 to 1.20, p = 0.32). In women with ≥80% medication adherence, preterm birth occurred in 24 (19.2%) versus 30 (24.8%) women (RR 0.77, 95% CI 0.48 to 1.25, p = 0.29). The rate of the composite of poor neonatal outcome was 4.6% (n = 9) versus 2.6% (n = 5) (RR 1.79, 95% CI 0.61 to 5.25, p = 0.29). Among all randomised women, serious adverse events occurred in 11 out of 204 (5.4%) women allocated to aspirin and 11 out of 202 (5.4%) women allocated to placebo. None of these serious adverse events was considered to be associated with treatment allocation. The main study limitation is the underpowered sample size due to the lower than expected preterm birth rates. CONCLUSIONS: In this study, we observed that low-dose aspirin did not significantly reduce the preterm birth rate in women with a previous spontaneous preterm birth. However, a modest reduction of preterm birth with aspirin cannot be ruled out. Further research is required to determine a possible beneficial effect of low-dose aspirin for women with a previous spontaneous preterm birth. TRIAL REGISTRATION: Dutch Trial Register (NL5553, NTR5675) https://www.trialregister.nl/trial/5553.


Asunto(s)
Aspirina/administración & dosificación , Trabajo de Parto Prematuro/prevención & control , Adulto , Relación Dosis-Respuesta a Droga , Método Doble Ciego , Femenino , Humanos , Países Bajos , Embarazo , Nacimiento Prematuro/prevención & control
17.
J Matern Fetal Neonatal Med ; 35(25): 7375-7380, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34304667

RESUMEN

BACKGROUND: The value of ST analysis of the fetal electrocardiogram during labor to lower asphyxia and cesarean section rates is uncertain. Physiological variation of the electrical heart axis between fetuses may explain false alarms in conventional ST analysis (absolute ST analysis). ST events (alarms) based on relative T/QRS rises (relative ST analysis) correct for this variation and may improve diagnostic accuracy of ST analysis. AIMS: To compare the diagnostic accuracy of absolute and relative ST analysis with regard to fetal acidemia. STUDY DESIGN: Retrospective case-control study. SUBJECTS: 20 healthy women with an uncomplicated pregnancy monitored with ST analysis during labor: 10 cases (umbilical cord artery pH < 7.05) and 10 controls (pH > 7.20). OUTCOME MEASURES: Sensitivity, specificity, positive and negative likelihood ratio. RESULTS: In 16 of the 20 patients a total of 54 absolute ST events were reported. Two reviewers classified the cardiotocograms; in cases 29% of the absolute ST events were significant, in the controls it was 19%. Relative ST analysis versus absolute ST analysis showed a sensitivity of 90% (55-100%) vs. 70% (35-93%), a specificity of 100% (69-100%) vs. 70% (35-93%), a positive likelihood ratio of infinity vs. 2.3 (0.8-6.5), a negative likelihood ratio of 0.1 (0.0-0.6) vs. 0.4 (0.2-1.2), and diagnostic odds ratio of infinity vs. 5.4 (0.8-36.9). McNemar showed no statistical significant difference between the sensitivity and specificity of the methods. CONCLUSIONS: We observed higher positive and lower negative likelihood ratios for relative ST analysis in comparison to absolute ST analysis. In this small study we found no statistical difference. Relative ST analysis should be studied in a larger study.


Asunto(s)
Cesárea , Trabajo de Parto , Humanos , Femenino , Embarazo , Estudios de Casos y Controles , Estudios Retrospectivos , Cardiotocografía/métodos , Electrocardiografía/métodos , Frecuencia Cardíaca Fetal , Monitoreo Fetal/métodos
18.
Front Pediatr ; 9: 793308, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34956991

RESUMEN

In this paper we present an initial roadmap for the ethical development and eventual implementation of artificial amniotic sac and placenta technology in clinical practice. We consider four elements of attention: (1) framing and societal dialogue; (2) value sensitive design, (3) research ethics and (4) ethical and legal research resulting in the development of an adequate moral and legal framework. Attention to all elements is a necessary requirement for ethically responsible development of this technology. The first element concerns the importance of framing and societal dialogue. This should involve all relevant stakeholders as well as the general public. We also identify the need to consider carefully the use of terminology and how this influences the understanding of the technology. Second, we elaborate on value sensitive design: the technology should be designed based upon the principles and values that emerge in the first step: societal dialogue. Third, research ethics deserves attention: for proceeding with first-in-human research with the technology, the process of recruiting and counseling eventual study participants and assuring their informed consent deserves careful attention. Fourth, ethical and legal research should concern the status of the subject in the AAPT. An eventual robust moral and legal framework for developing and implementing the technology in a research setting should combine all previous elements. With this roadmap, we emphasize the importance of stakeholder engagement throughout the process of developing and implementing the technology; this will contribute to ethically and responsibly innovating health care.

19.
PLoS One ; 16(12): e0256115, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34914710

RESUMEN

INTRODUCTION: A fetal anomaly scan in mid-pregnancy is performed, to check for the presence of congenital anomalies, including congenital heart disease (CHD). Unfortunately, 40% of CHD is still missed. The combined use of ultrasound and electrocardiography might boost detection rates. The electrical heart axis is one of the characteristics which can be deduced from an electrocardiogram (ECG). The aim of this study was to determine reference values for the electrical heart axis in healthy fetuses around 20 weeks of gestation. MATERIAL AND METHODS: Non-invasive fetal electrocardiography was performed subsequent to the fetal anomaly scan in pregnant women carrying a healthy singleton fetus between 18 and 24 weeks of gestation. Eight adhesive electrodes were applied on the maternal abdomen including one ground and one reference electrode, yielding six channels of bipolar electrophysiological measurements. After removal of interferences, a fetal vectorcardiogram was calculated and then corrected for fetal orientation. The orientation of the electrical heart axis was determined from this normalized fetal vectorcardiogram. Descriptive statistics were used on normalized cartesian coordinates to determine the average electrical heart axis in the frontal plane. Furthermore, 90% prediction intervals (PI) for abnormality were calculated. RESULTS: Of the 328 fetal ECGs performed, 281 were included in the analysis. The average electrical heart axis in the frontal plane was determined at 122.7° (90% PI: -25.6°; 270.9°). DISCUSSION: The average electrical heart axis of healthy fetuses around mid-gestation is oriented to the right, which is, due to the unique fetal circulation, in line with muscle distribution in the fetal heart.


Asunto(s)
Electrocardiografía , Corazón Fetal , Feto , Diagnóstico Prenatal , Adolescente , Adulto , Estudios de Cohortes , Femenino , Humanos , Embarazo
20.
Ned Tijdschr Geneeskd ; 1652021 08 05.
Artículo en Holandés | MEDLINE | ID: mdl-34351715

RESUMEN

Electrohysterography monitors the electrical activity of the uterine muscle through electrodes on the maternal abdominal wall. It is a non-invasive method for uterine contraction monitoring and has a strong correlation with the invasive intra-uterine pressure catheter. A prospective validation study showed a significant higher sensitivity of electrohysterography compared to external tocodynamometry for uterine contraction detection (p-value < 0.001). Moreover, the sensitivity of electrohysterography appears to be less affected by maternal obesity compared to external tocodynamometry. A clinical pilotstudy comparing electrohysterography and external tocodynamometry during labor, showed no negative effect of electrohysterography on labor outcomes. Recently, technical improvements have been made and electrohysterography has become available in an adhesive electrode patch together with fetal and maternal electrocardiography. Therefore, we expect a successful implementation of electrohysterography in the near future.


Asunto(s)
Trabajo de Parto , Monitoreo Uterino , Adolescente , Electromiografía , Femenino , Humanos , Monitoreo Fisiológico , Embarazo , Contracción Uterina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA