1.
Br J Haematol ; 204(5): 2103-2111, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38494337

RESUMEN

Red blood cell autoimmunity and alloimmunity are potentially linked. Quantification of this association can tailor extensively matched red blood cell transfusions in patients with autoimmunity. Using an incident new-user cohort comprising 47 285 previously non-transfused, non-alloimmunised patients, we compared transfusion-induced red blood cell alloimmunisation incidences in direct antiglobulin test (DAT)-positive and control patients. Additionally, we performed case-control analyses to handle potential confounding by clinical immunomodulators. Among (IgG and/or C3d) DAT-positive patients (N = 380), cumulative red blood cell alloimmunisation incidences after 10 units transfused reached 4.5% (95% confidence interval [CI] 2.5-8.2) versus 4.2% (CI 3.9-4.5, p = 0.88) in controls. In case-control analyses, alloimmunisation relative risks among DAT-positive patients increased to 1.7 (CI 1.1-2.8). Additional adjustments for pre-DAT transfusion exposure or the extent of Rh/K mismatching did not impact results. In conclusion, while patients with DAT positivity show an intrinsically increased alloimmune red blood cell response, their absolute risk is comparable to control patients due to counteracting co-existing immunosuppressive conditions. Consequently, isolated DAT positivity in patients lacking overt haemolysis or complicated alloantibody testing does not seem to warrant extended matching strategies.


Asunto(s)
Autoinmunidad , Transfusión de Eritrocitos , Eritrocitos , Humanos , Femenino , Masculino , Persona de Mediana Edad , Eritrocitos/inmunología , Factores de Riesgo , Adulto , Anciano , Transfusión de Eritrocitos/efectos adversos , Prueba de Coombs , Estudios de Casos y Controles , Isoanticuerpos/sangre , Isoanticuerpos/inmunología , Incompatibilidad de Grupos Sanguíneos/inmunología , Reacción a la Transfusión/inmunología , Reacción a la Transfusión/sangre , Reacción a la Transfusión/etiología
2.
Haematologica ; 2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38385259

RESUMEN

Previous studies found exposure to red blood cell transfusions from female donors who have been pregnant reduces survival in male patients compared to exposure to male donor products, but evidence is not consistent. We postulate the previously observed association is modified by offspring sex, with an expected increased mortality risk for male patients receiving units from female donors with sons. Here, marginal structural models were used to assess the association between exposure to units from ever-pregnant donors, ever-pregnant donors with sons and ever-pregnant donors with daughters, and mortality. Clinical data were collected on first-ever transfusion recipients in the Netherlands and donor data were supplemented with information about offspring sex and date of birth. In this analysis, 56,825 patients were included, of whom 8,288 died during follow-up. Exposure to red blood cell units from everpregnant donors with sons was not associated with increased all-cause mortality risk among male transfusion recipients (hazard ratio [HR] 0.91, 95% confidence interval 0.83-1.01). Exposure to ever-pregnant donors, irrespective of offspring sex, was associated with mortality in male patients aged between 18 and 50 years (ever-pregnant donors: HR 1.81, 95% CI 1.31-2.51) compared to male donor units, but was protective in female patients. This study suggests that the observed increased mortality risk for exposure to red blood cell units from parous female donors does not depend on offspring sex. The increased risk of mortality seen in younger adult male patients is consistent with previous observations, but the underlying biological mechanism could not be identified in this study.

3.
Lung Cancer ; 189: 107477, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38271919

RESUMEN

OBJECTIVES: Timely diagnosis of lung cancer (LC) is crucial to achieve optimal patient care and outcome. Moreover, the number of procedures required to obtain a definitive diagnosis can have a large influence on the life expectancy of a patient. Here, adherence with existing Dutch guidelines for timeliness and type and number of invasive and imaging procedures was assessed. MATERIALS AND METHODS: 1096 patients with suspected LC were enrolled in this multicenter prospective study (NL9146). The overall survival, time from referral to the first appointment with the pulmonologist, time to diagnosis and treatment, and the number of imaging and invasive procedures were evaluated. Patients were divided into different diagnostic groupsearly- and advanced stage non-small-cell lung cancer (NSCLC), small-cell lung cancer (SCLC), large cell neuroendocrine carcinoma of the lung (LCNEC), patients without LC and patients without a definitive diagnosis. RESULTS: The majority of patients (66 %) received a definitive diagnosis within 5 weeks, although the time to diagnosis of early-stage LC patients and patients without LC was significantly longer comparted to advanced stage LC. An increase in invasive procedures was seen for early-stage LC compared to advanced stage LC and for 13 % of the advanced stage non-squamous NSCLC patients up to three additional invasive procedures were performed solely to obtain sufficient material for NGS. For patients without a definitive diagnosis, 50 % did undergo at least one invasive procedure, while 11 % did not wish to undergo any invasive procedures. CONCLUSION: These insights could aid in improved LC diagnostics and efficient implementation of new techniques like liquid biopsy and artificial intelligence. This may lead to more timely LC care, a decreased number of invasive procedures, less variability between the diagnostic trajectory of different patients and aid in obtaining a definitive diagnosis for all patients.


Asunto(s)
Carcinoma Neuroendocrino , Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/terapia , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico , Carcinoma de Pulmón de Células no Pequeñas/terapia , Inteligencia Artificial , Estudios Prospectivos , Hospitales , Pulmón
4.
Clin Chem Lab Med ; 62(6): 1118-1125, 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38253354

RESUMEN

OBJECTIVES: Urea and creatinine concentrations in plasma are used to guide hemodialysis (HD) in patients with end-stage renal disease (ESRD). To support individualized HD treatment in a home situation, there is a clinical need for a non-invasive and continuous alternative to plasma for biomarker monitoring during and between cycles of HD. In this observational study, we therefore established the correlation of urea and creatinine concentrations between sweat, saliva and plasma in a cohort of ESRD patients on HD. METHODS: Forty HD patients were recruited at the Dialysis Department of the Catharina Hospital Eindhoven. Sweat and salivary urea and creatinine concentrations were analyzed at the start and at the end of one HD cycle and compared to the corresponding plasma concentrations. RESULTS: A decrease of urea concentrations during HD was observed in sweat, from 27.86 mmol/L to 12.60 mmol/L, and saliva, from 24.70 mmol/L to 5.64 mmol/L. Urea concentrations in sweat and saliva strongly correlated with the concentrations in plasma (ρ 0.92 [p<0.001] and 0.94 [p<0.001], respectively). Creatinine concentrations also decreased in sweat from 43.39 µmol/L to 19.69 µmol/L, and saliva, from 59.00 µmol/L to 13.70 µmol/L. However, for creatinine, correlation coefficients were lower than for urea for both sweat and saliva compared to plasma (ρ: 0.58 [p<0.001] and 0.77 [p<0.001], respectively). CONCLUSIONS: The results illustrate a proof of principle of urea measurements in sweat and saliva to monitor HD adequacy in a non-invasive and continuous manner. Biosensors enabling urea monitoring in sweat or saliva could fill in a clinical need to enable at-home HD for more patients and thereby decrease patient burden.


Asunto(s)
Creatinina , Diálisis Renal , Saliva , Sudor , Urea , Humanos , Urea/análisis , Urea/sangre , Saliva/química , Creatinina/sangre , Creatinina/análisis , Sudor/química , Femenino , Masculino , Estudios de Cohortes , Persona de Mediana Edad , Anciano , Fallo Renal Crónico/terapia , Fallo Renal Crónico/sangre , Adulto , Biomarcadores/análisis , Biomarcadores/sangre
5.
Hemodial Int ; 28(1): 72-76, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37962053

RESUMEN

PURPOSE: Apixaban is a factor Xa inhibitor used in patients undergoing hemodialysis treatment. The objective of this study is to investigate the effect of hemodialysis on apixaban plasma concentrations. METHODS: This observational study is on patients treated with apixaban 2.5 mg twice daily on conventional hemodialysis with standard low-molecular-weight heparin (LMWH) anticoagulation (nadroparin 3800-7600 IU). Plasma blood samples were collected before starting dialysis (t1), 2 h after starting dialysis (t2), and directly after dialysis (t3). Apixaban concentration was measured before and after dialysis. Anti-Xa activity was measured for all three samples. RESULTS: A significant difference was observed between the apixaban concentration before and after dialysis (mean before dialysis 141.03 ng/mL; mean after dialysis 102.71 ng/mL; p = 0.003). Nonetheless, both apixaban plasma concentrations and anti-Xa levels remained within the reference range. Anti-Xa levels had a strong correlation with the apixaban concentrations (r = 0.935, p = 0.000). Thus, anti-Xa activity might be used as a surrogate for apixaban plasma concentration. CONCLUSION: There seems to be no need for dose adjustments of apixaban; co-administration of LMWH next to apixaban might also be unnecessary.


Asunto(s)
Anticoagulantes , Heparina de Bajo-Peso-Molecular , Pirazoles , Piridonas , Humanos , Anticoagulantes/uso terapéutico , Diálisis Renal/efectos adversos , Coagulación Sanguínea
6.
Vox Sang ; 119(1): 43-52, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37920882

RESUMEN

BACKGROUND AND OBJECTIVES: Donor characteristics have been implicated in transfusion-related adverse events. Uncertainty remains about whether sex, and specifically pregnancy history of the blood donor, could affect patient outcomes. Whether storage duration of the blood product could be important for patient outcomes has also been investigated, and a small detrimental effect of fresh products remains a possibility. Here, we hypothesize that fresh red blood cell products donated by ever-pregnant donors are associated with mortality in male patients. MATERIALS AND METHODS: We used data from a cohort study of adult patients receiving a first transfusion between 2005 and 2015 in the Netherlands. The risk of death after receiving a transfusion from one of five exposure categories (female never-pregnant stored ≤10 days, female never-pregnant stored >10 days, female ever-pregnant stored ≤10 days, female ever-pregnant stored >10 days and male stored for ≤10 days), compared to receiving a unit donated by a male donor, which was stored for >10 days (reference), was calculated using a Cox proportional hazards model. RESULTS: The study included 42,456 patients who contributed 88,538 person-years in total, of whom 13,948 died during the follow-up of the study (33%). Fresh units (stored for ≤10 days) from ever-pregnant donors were associated with mortality in male patients, but the association was not statistically significant (hazard ratio 1.39, 95% confidence interval 0.97-1.99). Sensitivity analyses did not corroborate this finding. CONCLUSION: These findings do not consistently support the notion that the observed association between ever-pregnant donor units and mortality is mediated by blood product storage.


Asunto(s)
Transfusión de Eritrocitos , Eritrocitos , Adulto , Embarazo , Humanos , Masculino , Femenino , Estudios de Cohortes , Transfusión de Eritrocitos/efectos adversos , Modelos de Riesgos Proporcionales , Donantes de Sangre , Conservación de la Sangre/efectos adversos
7.
Clin Chem Lab Med ; 62(4): 720-728, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-37886827

RESUMEN

OBJECTIVES: Numerous studies have proven the potential of cytokeratin 19 fragment 21-1 (CYFRA 21-1) detection in the (early) diagnosis and treatment monitoring of non-small cell lung cancer (NSCLC). Conventional immunoassays for CYFRA 21-1 quantification are however prone to interferences and lack diagnostic sensitivity and standardization. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is an emerging approach based on a different, often superior, detection principle, which may improve the clinical applicability of CYFRA 21-1 in cancer diagnostics. Therefore, we developed and validated a protein precipitation, immunoaffinity (IA) LC-MS/MS assay for quantitative analysis of serum CYFRA 21-1. METHODS: Selective sample preparation was performed using ammonium sulfate (AS) precipitation, IA purification, tryptic digestion and LC-MS/MS quantification using a signature peptide and isotopically labeled internal standard. The workflow was optimized and validated according to EMA guidelines and results were compared to a conventional immunoassay. RESULTS: Significant interference effects were seen during IA purification, which were sufficiently solved by performing AS precipitation prior to IA purification. A linear calibration curve was obtained in the range of 1.0-100 ng/mL (R2=0.98). Accuracy and precision were well within acceptance criteria. In sera of patients suspected of lung cancer, the method showed good correlation with the immunoassay. CONCLUSIONS: A robust AS precipitation-IA LC-MS/MS assay for the quantification of serum CYFRA 21-1 was developed. With this assay, the clinically added value of LC-MS/MS-based detection over immunoassays can be further explored.


Asunto(s)
Antígenos de Neoplasias , Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Humanos , Cromatografía Liquida/métodos , Queratina-19 , Espectrometría de Masas en Tándem/métodos , Neoplasias Pulmonares/diagnóstico , Biomarcadores de Tumor , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico , Cromatografía Líquida con Espectrometría de Masas
8.
Artículo en Inglés | MEDLINE | ID: mdl-37086508

RESUMEN

Neuron-specific enolase (NSE) is a promising small-cell lung cancer (SCLC) biomarker composed of αγ and γγ isozyme dimers. As the conventional immunoassays are prone to interferences and cannot differentiate between the isozymes, we developed a multiplex immunoaffinity (IA) liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for the quantification of NSEα and NSEγ in human serum. A calibrator was prepared by performing cold denaturation of recombinantly expressed αα and γγ enolase dimers to induce a new dimer equilibrium that was determined to be approximately 1αγ:1γγ:1αα. Selective sample purification was achieved by performing IA extraction using an antibody specific towards NSEγ. The isolated αγ and γγ dimers were denatured and trypsin digested to allow quantification of the selected signature peptides and their corresponding isotopically labelled peptide internal standard. The obtained linear dynamic ranges were determined to be 1.5-56 ng/mL and 0.64-167 ng/mL for NSEα and NSEγ (R2 = 0.88 and 0.97 respectively). Validation of the assay showed acceptable accuracy and precision for NSEα and NSEγ. The method was successfully applied to patient serum in which both isozymes were detected. Compared to the conventional immunoassay, substantially lower total NSE concentrations were measured in IA LC-MS/MS. With this multiplex IA LC-MS/MS assay, the clinical value of quantifying the individual isozymes can be explored. In addition, together with the calibrator described here, it may be applied to standardize NSE immunoassays across different platforms.


Asunto(s)
Isoenzimas , Espectrometría de Masas en Tándem , Humanos , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Péptidos , Fosfopiruvato Hidratasa , Reproducibilidad de los Resultados
9.
Lung Cancer ; 178: 28-36, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36773458

RESUMEN

OBJECTIVES: Pathologic subtyping of tissue biopsies is the gold standard for the diagnosis of lung cancer (LC), which could be complicated in cases of e.g. inconclusive tissue biopsies or unreachable tumors. The diagnosis of LC could be supported in a minimally invasive manner using protein tumor markers (TMs) and circulating tumor DNA (ctDNA) measured in liquid biopsies (LBx). This study evaluates the performance of LBx-based decision-support algorithms for the diagnosis of LC and subtyping into small- and non-small-cell lung cancer (SCLC and NSCLC) aiming to directly impact clinical practice. MATERIALS AND METHODS: In this multicenter prospective study (NL9146), eight protein TMs (CA125, CA15.3, CEA, CYFRA 21-1, HE4, NSE, proGRP and SCCA) and ctDNA mutations in EGFR, KRAS and BRAF were analyzed in blood of 1096 patients suspected of LC. The performance of individual and combined TMs to identify LC, NSCLC or SCLC was established by evaluating logistic regression models at pre-specified positive predictive values (PPV) of ≥95% or ≥98%. The most informative protein TMs included in the multi-parametric models were selected by recursive feature elimination. RESULTS: Single TMs could identify LC, NSCLC and SCLC patients with 46%, 25% and 40% sensitivity, respectively, at pre-specified PPVs. Multi-parametric models combining TMs and ctDNA significantly improved sensitivities to 65%, 67% and 50%, respectively. CONCLUSION: In patients suspected of LC, the LBx-based decision-support algorithms allowed identification of about two-thirds of all LC and NSCLC patients and half of SCLC patients. These models therefore show clinical value and may support LC diagnostics, especially in patients for whom pathologic subtyping is impossible or incomplete.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/genética , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico , Carcinoma de Pulmón de Células no Pequeñas/genética , Carcinoma de Pulmón de Células no Pequeñas/patología , Estudios Prospectivos , Biomarcadores de Tumor , Fosfopiruvato Hidratasa , Biopsia Líquida
10.
Res Pract Thromb Haemost ; 7(1): 100017, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36785755

RESUMEN

Background: We present the case of a 15-year-old adolescent with suspected pulmonary embolism and repeatedly elevated D-dimer levels. Key Clinical Question: We aim to determine the cause for elevated D-dimer levels in a patient without venous thromboembolism. Clinical Approach: When the D-dimer measurement was repeated with different assays, D-dimer levels were within the normal reference interval. Dilution series with assay diluent or low-affinity antibody blocking reagents either did not or only partially decreased the D-dimer value using the original reagent kit. Conclusion: Analyses suggested the presence of interfering heterophilic antibodies in patient plasma, a known phenomenon with immunoturbidimetric D-dimer assays, which is rarely described. Prior to drawing this conclusion, the patient underwent extensive diagnostic testing, which led to uncertainty and discomfort for the health care providers, the patient, and their family.

11.
J Pharm Biomed Anal ; 221: 115027, 2022 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-36099723

RESUMEN

Establishing dihydropyrimidine dehydrogenase (DPD) activity is highly important in determining the correct starting dose of fluoropyrimidines such as 5-fluorouracil and capecitabine. The concentration ratio of endogenous uracil with its metabolite dihydrouracil (DHU) is a well-known parameter that is linked to DPD activity. Concentration ratios such as thymine over its DPD-converted metabolite dihydrothymine (DHT) is less described and may serve as an alternative diagnostic biomarker for DPD activity. In this study, we describe the development and validation of an ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) assay for the quantification of uracil, DHU, thymine, and DHT in human plasma. In addition, stability experiments were performed. Uracil and thymine were quantified up to 80.0 ng/mL and DHU and DHT up to 800 ng/mL. Intra- and inter-assay precision were maximum 8.0 % and 7.6 %. respectively. Also, recovery was adequate and significant matrix-effects and carry-over were excluded. Stability experiments showed that uracil concentrations increased with 27-52 % when stored for 1 or 2 h at ambient temperatures compared to cold storage. Thymine, DHU, and DHT concentrations remained stable, thymine after 1 h in plasma excluded, showing the DHT:T ratio might be a more robust marker for DPD activity than DHU:U. In conclusion, we present here a novel assay capable of quantifying uracil, thymine, DHU and DHT in a single analytical run. We provide additional data showing increased stability for DHU, thymine and DHT compared to uracil. This assay may be used as a diagnostic test in future studies, establishing the association of these endogenous biomarker concentrations with DPD activity and safety to treatment with fluoropyrimidines. In addition, future research should also be focused on reducing pre-analytical instability. Standardization in this field is essential to set proper reference values and to allow inter-study comparison on clinical outcomes.


Asunto(s)
Dihidrouracilo Deshidrogenasa (NADP) , Timina , Biomarcadores , Capecitabina , Cromatografía Liquida , Dihidrouracilo Deshidrogenasa (NADP)/metabolismo , Fluorouracilo , Humanos , Espectrometría de Masas en Tándem , Uracilo/análogos & derivados
13.
Br J Haematol ; 195(4): 604-611, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34346067

RESUMEN

Maternal alloantibodies directed against fetal red blood cell (RBC) antigens may cause potentially life-threatening haemolytic disease of the fetus and newborn (HDFN). Dutch transfusion guidelines therefore prescribe preventive cEK matching for all (pre-)fertile females. To quantify the impact of cEK matching, we compared overall and antigen-specific cumulative RBC alloimmunisation incidences in females and males aged <45 years. Among a multicentre cohort comprised of patients who received their first and subsequent RBC unit between 2005 and 2019, first-formed RBC alloantibodies were detected in 47 of 2998 (1·6%) females and 49 of 2507 (2·0%) males. Comparing females and males, overall alloimmunisation incidences were comparable (3·1% [95% confidence interval (CI) 2·1-4·4] versus 3·5% (95% CI 2·4-4·9, P = 0·853) after 10 units transfused). However, cEK alloimmunisation incidences were significantly lower among females (0·6% (95% CI 0·3-1.5) versus 2·2% (95% CI 1·5-3·4, P = 0·001) after 10 units transfused). Yet, despite cEK-matching guidelines being in effect, 6·5%, 3·6% and 0·2% of all RBC units remained mismatched for c, E or K antigens respectively. Most of these mismatches were almost always due to emergency settings. Even though cEK alloimmunisation was not prevented completely, implementation of cEK matching resulted in an alloantigen-exposure risk reduction of up to 98%.


Asunto(s)
Incompatibilidad de Grupos Sanguíneos/genética , Tipificación y Pruebas Cruzadas Sanguíneas , Eritroblastosis Fetal/etiología , Eritrocitos/inmunología , Isoanticuerpos/biosíntesis , Sistema del Grupo Sanguíneo de Kell/inmunología , Sistema del Grupo Sanguíneo Rh-Hr/inmunología , Reacción a la Transfusión/epidemiología , Adulto , Eritroblastosis Fetal/genética , Eritroblastosis Fetal/inmunología , Femenino , Humanos , Incidencia , Isoanticuerpos/inmunología , Sistema del Grupo Sanguíneo de Kell/genética , Masculino , Sistema del Grupo Sanguíneo Rh-Hr/genética , Adulto Joven
14.
Urol Oncol ; 39(3): 161-170, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33376063

RESUMEN

Non-muscle-invasive bladder cancer (NMIBC) is accompanied with high incidence and recurrence rates. The extensive need for cystoscopic follow up causes substantial patient discomfort and leads to a high economic burden. Cytology of exfoliated tumor cells in urine is not able to safely reduce or replace the amount of cystoscopies. Here, we give a short overview of established urinary biomarkers and review 2 novel urinary biomarkers, ADXBLADDER and Bladder EpiCheck, for their clinical utility in NMIBC. A Pubmed literature search was performed on the subject of urinary biomarkers for NMIBC. The performance of urinary cytology and established biomarkers Nuclear matrix proteins (NMP22), BTA, UroVysion, and ImmunoCyt was evaluated. The performance of novel biomarkers ADXBLADDER and Bladder EpiCheck was critically reviewed. Based on available clinical studies, established urinary biomarkers have no clear role in the diagnosis or follow-up of NMIBC. Three available prospective studies of ADXBLADDER (2 studying initial diagnosis and 1 follow-up study) reported overall sensitivity (45%-73%) and negative predictive values (NPV) (74%-100%) superior to cytology, with reasonable specificity (70%-73%). Four follow-up Bladder EpiCheck studies reported overall sensitivity (62%-90%) and NPV (79%-97%) superior to cytology, with a high specificity (82%-88%). For detection of high grade recurrences, sensitivity, and NPV of both novel biomarkers were even higher, with a sensitivity and NPV of 76% to 88% and 99% respectively for ADXBLADDER and 79% to 95% and 99% respectively for Bladder EpiCheck - Novel urinary biomarkers ADXBLADDER and Bladder EpiCheck have better sensitivity and NPV, but worse specificity than cytology in the follow-up of NMIBC. In the future, these biomarkers might reduce the amount of follow-up cystoscopies, for instance via an intermittent follow-up scheme alternating between cystoscopy and biomarker testing. The main biomarker objective should be to rule out high grade tumor recurrence without the need for any invasive procedures. Nevertheless, the clinical implementation of these biomarkers in the follow up of NMIBC has to be further investigated in prospective randomized trials for low as well as high grade tumors.


Asunto(s)
Biomarcadores de Tumor/orina , Neoplasias de la Vejiga Urinaria/orina , Humanos , Invasividad Neoplásica , Urinálisis/métodos , Neoplasias de la Vejiga Urinaria/patología
15.
Transfusion ; 61(1): 35-41, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33295653

RESUMEN

BACKGROUND: Renal failure and renal replacement therapy (RRT) affect the immune system and could therefore modulate red blood cell (RBC) alloimmunization after transfusion. STUDY DESIGN AND METHODS: We performed a nationwide multicenter case-control study within a source population of newly transfused patients between 2005 and 2015. Using conditional multivariate logistic regression, we compared first-time transfusion-induced RBC alloantibody formers (N = 505) with two nonalloimmunized recipients with similar transfusion burden (N = 1010). RESULTS: Renal failure was observed in 17% of the control and 13% of the case patients. A total of 41% of the control patients and 34% of case patients underwent acute RRT. Renal failure without RRT was associated with lower alloimmunization risks after blood transfusion (moderate renal failure: adjusted relative rate [RR], 0.82 [95% confidence interval (CI), 0.67-1.01]); severe renal failure, adjusted RR, 0.76 [95% CI, 0.55-1.05]). With severe renal failure patients mainly receiving RRT, the lowest alloimmunization risk was found in particularly these patients [adjusted RR 0.48 (95% CI 0.39-0.58)]. This was similar for patients receiving RRT for acute or chronic renal failure (adjusted RR, 0.59 [95% CI, 0.46-0.75]); and adjusted RR, 0.62 [95% CI 0.45-0.88], respectively). CONCLUSION: These findings are indicative of a weakened humoral response in acute as well as chronic renal failure, which appeared to be most pronounced when treated with RRT. Future research should focus on how renal failure and RRT mechanistically modulate RBC alloimmunization.


Asunto(s)
Transfusión de Eritrocitos/efectos adversos , Eritrocitos/inmunología , Insuficiencia Renal/etiología , Anciano , Transfusión Sanguínea , Estudios de Casos y Controles , Correlación de Datos , Femenino , Humanos , Fallo Renal Crónico/etiología , Modelos Logísticos , Masculino , Persona de Mediana Edad , Insuficiencia Renal/complicaciones , Insuficiencia Renal/inmunología , Insuficiencia Renal Crónica/etiología , Terapia de Reemplazo Renal , Factores de Riesgo , Reacción a la Transfusión/complicaciones
16.
Clin Chem Lab Med ; 59(2): 315-323, 2020 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-33001847

RESUMEN

Objectives: Hepcidin measurement advances insights in pathophysiology, diagnosis, and treatment of iron disorders, but requires analytically sound and standardized measurement procedures (MPs). Recent development of a two-level secondary reference material (sRM) for hepcidin assays allows worldwide standardization. However, no proficiency testing (PT) schemes to ensure external quality assurance (EQA) exist and the absence of a high calibrator in the sRM set precludes optimal standardization. Methods: We developed a pilot PT together with the Dutch EQA organization Stichting Kwaliteitsbewaking Medische Laboratoriumdiagnostiek (SKML) that included 16 international hepcidin MPs. The design included 12 human serum samples that allowed us to evaluate accuracy, linearity, precision and standardization potential. We manufactured, value-assigned, and validated a high-level calibrator in a similar manner to the existing low- and middle-level sRM. Results: The pilot PT confirmed logistical feasibility of an annual scheme. Most MPs demonstrated linearity (R2>0.99) and precision (duplicate CV>12.2%), although the need for EQA was shown by large variability in accuracy. The high-level calibrator proved effective, reducing the inter-assay CV from 42.0% (unstandardized) to 14.0%, compared to 17.6% with the two-leveled set. The calibrator passed international homogeneity criteria and was assigned a value of 9.07±0.24 nmol/L. Conclusions: We established a framework for future PT to enable laboratory accreditation, which is essential to ensure quality of hepcidin measurement and its use in patient care. Additionally, we showed optimized standardization is possible by extending the current sRM with a third high calibrator, although international implementation of the sRM is a prerequisite for its success.


Asunto(s)
Hepcidinas/sangre , Acreditación , Recolección de Muestras de Sangre , Calibración , Cromatografía Líquida de Alta Presión , Ensayo de Inmunoadsorción Enzimática , Humanos , Laboratorios/normas , Garantía de la Calidad de Atención de Salud/normas , Control de Calidad , Estándares de Referencia , Espectrometría de Masas en Tándem
17.
Oncotarget ; 11(27): 2660-2668, 2020 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-32676167

RESUMEN

Neuron-specific enolase (NSE) is a well-known biomarker for the diagnosis, prognosis and treatment monitoring of small-cell lung cancer (SCLC). Nevertheless, its clinical applicability is limited since serum NSE levels are influenced by hemolysis, leading to falsely elevated results. Therefore, this study aimed to develop a hemolysis correction equation and evaluate its role in SCLC diagnostics. Two serum pools were spiked with increasing amounts of hemolysate obtained from multiple individuals. A hemolysis correction equation was obtained by analyzing the relationship between the measured NSE concentration and the degree of hemolysis. The equation was validated using intentionally hemolyzed serum samples, which showed that the correction was accurate for samples with an H-index up to 30 µmol/L. Correction of the measured NSE concentration in patients suspected of lung cancer caused an increase in AUC and a significantly lower cut-off value for SCLC detection when compared to uncorrected results. Therefore, a hemolysis correction equation should be used to correct falsely elevated NSE concentrations. Results of samples with an H-index above 30 µmol/L should not be reported to clinicians. Application of the equation illustrates the importance of hemolysis correction in SCLC diagnostics and questions the correctness of the currently used diagnostic cut-off value.

18.
Eur Heart J Cardiovasc Pharmacother ; 5(2): 91-99, 2019 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-30608563

RESUMEN

AIMS: Effective anticoagulation in patients undergoing electrical cardioversion (ECV) for symptomatic atrial fibrillation is important to prevent adverse events. High medication adherence is a requirement. In patients with newly diagnosed atrial fibrillation (n = 169) who were intended to undergo ECV, the aim of this study was to measure self-reported short- and long-term adherence, evaluate whether dabigatran plasma concentrations reflect adherence, measure treatment satisfaction and assess whether adherence and treatment satisfaction are correlated. METHODS AND RESULTS: Plasma concentrations (liquid-chromatography tandem mass spectrometry), the 8-point Morisky Medication Adherence Scale (MMAS-8) and the Anti-Clot Treatment Scale (ACTS) were measured after 3 weeks and 7 weeks of treatment. Combined mean peak (1-3 h after intake) and trough (10-16 h after intake) plasma concentrations were 175 (SD 109) ng/mL and 75 (SD 45) ng/mL, respectively. There was no relationship between short-term adherence (last 3 days) or long-term adherence (last 3-4 weeks) and plasma concentrations, unless the last intake was more than 48 h ago. After 7 weeks high, moderate, and low adherence, according to the MMAS-8, was seen in 74%, 21%, and 5% of patients, respectively. Treatment satisfaction was high (median ACTS score 68.5, range 46-75 points). Treatment satisfaction and adherence were not correlated. CONCLUSION: The percentage of patients in the high adherence group (74%) was lower than expected, which is a matter of concern. Dabigatran plasma concentrations could not detect short- or long-term non-adherence, unless the drug was last taken more than 48 h ago. Treatment satisfaction did not correlate with adherence.


Asunto(s)
Antitrombinas/administración & dosificación , Fibrilación Atrial/terapia , Dabigatrán/administración & dosificación , Cardioversión Eléctrica , Cumplimiento de la Medicación , Anciano , Antitrombinas/sangre , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Cromatografía Liquida , Dabigatrán/sangre , Monitoreo de Drogas/métodos , Femenino , Humanos , Masculino , Satisfacción del Paciente , Estudios Prospectivos , Autoinforme , Espectrometría de Masas en Tándem , Factores de Tiempo , Resultado del Tratamiento
19.
Clin Chem Lab Med ; 56(9): 1490-1497, 2018 08 28.
Artículo en Inglés | MEDLINE | ID: mdl-29777607

RESUMEN

BACKGROUND: Targeted quantification of protein biomarkers with liquid chromatography-tandem mass spectrometry (LC-MS/MS) has great potential, but is still in its infancy. Therefore, we elucidated the influence of charge state distribution and matrix effects on accurate quantification, illustrated by the peptide hormone hepcidin. METHODS: An LC-MS/MS assay for hepcidin, developed based on existing literature, was improved by using 5 mM ammonium formate buffer as mobile phase A and as an elution solution for solid phase extraction (SPE) to optimize the charge state distribution. After extensive analytical validation, focusing on interference and matrix effects, the clinical consequence of this method adjustment was studied by performing receiving operating characteristic (ROC)-curve analysis in patients with iron deficiency anemia (IDA, n=44), anemia of chronic disease (ACD, n=42) and non-anemic patients (n=93). RESULTS: By using a buffered solution during sample preparation and chromatography, the most abundant charge state was shifted from 4+ to 3+ and the charge state distribution was strongly stabilized. The matrix effects which occurred in the 4+ state were therefore avoided, eliminating bias in the low concentration range of hepcidin. Consequently, sensitivity, specificity and positive predictive value (PPV) for detection of IDA patients with the optimized assay (96%, 97%, 91%, respectively) were much better than for the original assay (73%, 70%, 44%, respectively). CONCLUSIONS: Fundamental improvements in LC-MS/MS assays greatly impact the accuracy of protein quantification. This is urgently required for improved diagnostic accuracy and clinical value, as illustrated by the validation of our hepcidin assay.


Asunto(s)
Biomarcadores/análisis , Cromatografía Líquida de Alta Presión/métodos , Hepcidinas/análisis , Espectrometría de Masas en Tándem/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Anemia/patología , Anemia Ferropénica/patología , Área Bajo la Curva , Proteína C-Reactiva/análisis , Enfermedad Crónica , Femenino , Hepcidinas/aislamiento & purificación , Humanos , Masculino , Persona de Mediana Edad , Curva ROC , Extracción en Fase Sólida , Adulto Joven
20.
Thromb Res ; 164: 32-39, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29475179

RESUMEN

BACKGROUND: Issues with laboratory measurement of dabigatran include: 1. Do coagulation assays reflect dabigatran plasma concentrations? 2. Do samples from patients treated with dabigatran have the same coagulability as dabigatran-spiked samples from healthy volunteers? 3. What is the long-term stability of dabigatran after storage at -80 °C? This study aims to evaluate these questions. MATERIALS AND METHODS: Ecarin chromogenic assay (ECA), a laboratory-developed diluted thrombin time (LD-dTT), prothrombin time (PT) and activated partial thromboplastin time (APTT) and ROTEM® were used to measure dabigatran anticoagulant activity and liquid chromatography-tandem mass spectrometry (LC-MS/MS) to measure dabigatran plasma concentrations. ROTEM® (EXTEM, INTEM, FIBTEM) was performed in whole blood and the other assays in platelet poor plasma (PPP), both in samples spiked with dabigatran (0, 25, 50, 100, 250, 500 and 1000 ng/mL) from healthy donors and in ex vivo samples from patients treated with dabigatran etexilate. Citrated PPP samples were frozen and stored at -80 °C, 1, 3, 6 and 12 months until analysis. RESULTS: EXTEM and FIBTEM clotting time (CT), ECA and LD-dTT correlate well with dabigatran plasma concentrations. With the exception of few ROTEM® parameters, there were no differences between spiked and patient samples. Samples were stable for at least 12 months at -80 °C. CONCLUSIONS: EXTEM and FIBTEM CT, ECA and LD-dTT are suitable for measuring the effect of dabigatran in treated patients. In general, results from spiked plasma samples are similar to those of patient samples. Storage of dabigatran plasma samples for up to 12 months does not influence measured levels.


Asunto(s)
Coagulación Sanguínea/efectos de los fármacos , Adolescente , Adulto , Anciano , Anticoagulantes/farmacología , Anticoagulantes/uso terapéutico , Dabigatrán/farmacología , Dabigatrán/uso terapéutico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven