Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Metabolites ; 14(5)2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38786725

RESUMEN

Torin1, a selective kinase inhibitor targeting the mammalian target of rapamycin (mTOR), remains widely used in autophagy research due to its potent autophagy-inducing abilities, regardless of its unspecific properties. Recognizing the impact of mTOR inhibition on metabolism, our objective was to develop a reliable and thorough untargeted metabolomics workflow to study torin1-induced metabolic changes in mouse embryonic fibroblast (MEF) cells. Crucially, our quality assurance and quality control (QA/QC) protocols were designed to increase confidence in the reported findings by reducing the likelihood of false positives, including a validation experiment replicating all experimental steps from sample preparation to data analysis. This study investigated the metabolic fingerprint of torin1 exposure by using liquid chromatography-high resolution mass spectrometry (LC-HRMS)-based untargeted metabolomics platforms. Our workflow identified 67 altered metabolites after torin1 exposure, combining univariate and multivariate statistics and the implementation of a validation experiment. In particular, intracellular ceramides, diglycerides, phosphatidylcholines, phosphatidylethanolamines, glutathione, and 5'-methylthioadenosine were downregulated. Lyso-phosphatidylcholines, lyso-phosphatidylethanolamines, glycerophosphocholine, triglycerides, inosine, and hypoxanthine were upregulated. Further biochemical pathway analyses provided deeper insights into the reported changes. Ultimately, our study provides a valuable workflow that can be implemented for future investigations into the effects of other compounds, including more specific autophagy modulators.

2.
Sci Total Environ ; 929: 172483, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38631629

RESUMEN

Per- and polyfluoroalkyl substances (PFAS) remain controversial due to their high persistency and potential human toxicity. Although occupational exposure to PFAS has been widely investigated, the implications of PFAS occurrence in the general population remain to be unraveled. Considering that serum from most people contains PFAS, the aim of this study was to characterize the lipidomic profile in human serum from a general cohort (n = 40) with residual PFAS levels. The geometric means of ∑PFAS (11.8 and 4.4 ng/mL) showed significant differences (p < 0.05) for the samples with the highest (n = 20) and lowest (n = 20) concentrations from the general population respectively. Reverse-phase liquid chromatography coupled to drift tube ion mobility and high-resolution mass spectrometry using dual polarity ionization was used to characterize the lipid profile in both groups. The structural elucidation involved the integration of various parameters, such as retention time, mass-to-charge ratio, tandem mass spectra and collision cross section values. This approach yielded a total of 20 potential biomarkers linked to the perturbed glycerophospholipid metabolism, energy metabolism and sphingolipid metabolism. Among these alterations, most lipids were down-regulated and some specific lipids (PC 36:5, PC 37:4 and PI O-34:2) exhibited a relatively strong Spearman correlation and predictive capacity for PFAS contamination. This study could support further toxicological assessments and mechanistic investigations into the effects of PFAS exposure on the lipidome.


Asunto(s)
Contaminantes Ambientales , Fluorocarburos , Lipidómica , Humanos , Fluorocarburos/sangre , Contaminantes Ambientales/sangre , Cromatografía Liquida , China , Espectrometría de Masas , Estudios de Cohortes , Adulto , Masculino , Exposición a Riesgos Ambientales/estadística & datos numéricos , Femenino , Persona de Mediana Edad , Espectrometría de Movilidad Iónica/métodos , Lípidos/sangre , Monitoreo del Ambiente/métodos , Pueblos del Este de Asia
3.
Anal Bioanal Chem ; 415(23): 5589-5604, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37468753

RESUMEN

Lipidomics investigates the composition and function of lipids, typically employing blood or tissue samples as the primary study matrices. Hair has recently emerged as a potential complementary sample type to identify biomarkers in early disease stages and retrospectively document an individual's metabolic status due to its long detection window of up to several months prior to the time of sampling. However, the limited coverage of lipid profiling presented in previous studies has hindered its exploitation. This study aimed to evaluate the lipid coverage of hair using an untargeted liquid chromatography-high-resolution mass spectrometry lipidomics platform. Two distinct three-step exhaustive extraction experiments were performed using a hair metabolomics one-phase extraction technique that has been recently optimized, and the two-phase Folch extraction method which is recognized as the gold standard for lipid extraction in biological matrices. The applied lipidomics workflow improved hair lipid coverage, as only 99 species could be annotated using the one-phase extraction method, while 297 lipid species across six categories were annotated with the Folch method. Several lipids in hair were reported for the first time, including N-acyl amino acids, diradylglycerols, and coenzyme Q10. The study suggests that hair lipids are not solely derived from de novo synthesis in hair, but are also incorporated from sebum and blood, making hair a valuable matrix for clinical, forensic, and dermatological research. The improved understanding of the lipid composition and analytical considerations for retrospective analysis offers valuable insights to contextualize untargeted hair lipidomic analysis and facilitate the use of hair in translational studies.


Asunto(s)
Lipidómica , Lípidos , Lipidómica/métodos , Estudios Retrospectivos , Lípidos/análisis , Cromatografía Liquida/métodos , Cabello/química
4.
Arch Toxicol ; 97(5): 1335-1353, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36826472

RESUMEN

Despite the high prevalence of alcoholic liver disease, its identification and characterization remain poor, especially in early stages such as alcoholic fatty liver disease and alcoholic steatohepatitis. This latter implies diagnostic difficulties, few therapeutic options and unclear mechanisms of action. To elucidate the metabolic alterations and pinpoint affected biochemical pathways, alcoholic steatohepatitis was simulated in vitro by exposing HepaRG cells to ethanol (IC10, 368 mM) and tumor necrosis factor alpha (TNF-α, 50 ng/mL) for 24 h. This combined exposure was compared to solely ethanol-exposed as well as -nonexposed cells. Four different metabolomics platforms were used combining liquid chromatography, high-resolution mass spectrometry and drift tube ion mobility to elucidate both intracellular and extracellular metabolic alterations. Some of the key findings include the influence of TNF-α in the upregulation of hepatic triglycerides and the downregulation of hepatic phosphatidylethanolamines and phosphatidylcholines. S-Adenosylmethionine showed to play a central role in the progression of alcoholic steatohepatitis. In addition, fatty acyl esters of hydroxy fatty acid (FAHFA)-containing triglycerides were detected for the first time in human hepatocytes and their alterations showed a potentially important role during the progression of alcoholic steatohepatitis. Ethoxylated phosphorylcholine was identified as a potential new biomarker of ethanol exposure.


Asunto(s)
Hígado Graso Alcohólico , Enfermedad del Hígado Graso no Alcohólico , Humanos , Hígado Graso Alcohólico/metabolismo , Hígado Graso Alcohólico/patología , Etanol/toxicidad , Factor de Necrosis Tumoral alfa/metabolismo , Cromatografía Liquida , Espectrometría de Masas en Tándem , Hígado/metabolismo , Enfermedad del Hígado Graso no Alcohólico/metabolismo , Metabolómica , Triglicéridos/metabolismo
5.
Methods Mol Biol ; 2571: 189-206, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36152163

RESUMEN

Metabolites represent the most downstream level of the cellular organization. Hence, an in vitro untargeted metabolomics approach is extremely valuable to deepen the understanding of how endogenous metabolites in cells are altered under a given biological condition. This chapter describes a robust liquid chromatography-high-resolution mass spectrometry-based metabolomics and lipidomics platform applied to cell culture extracts. The analytical workflow includes an optimized sample preparation procedure to cover a wide range of metabolites using liquid-liquid extraction and validated instrumental operation procedures with the implementation of comprehensive quality assurance and quality control measures to ensure high reproducibility. The lipidomics platform is based on reversed-phase liquid chromatography for the separation of slightly polar to apolar metabolites and covers a broad range of lipid classes, while the metabolomics platform makes use of two hydrophilic interaction liquid chromatography methods for the separation of polar metabolites, such as organic acids, amino acids, and sugars. The chapter focuses on the analysis of cultured HepaRG cells that are derived from a human hepatocellular carcinoma; however, the sample preparation and analytical platforms can easily be adapted for other types of cells.


Asunto(s)
Lipidómica , Metabolómica , Aminoácidos , Técnicas de Cultivo de Célula , Extractos Celulares , Humanos , Lípidos , Espectrometría de Masas/métodos , Metabolómica/métodos , Reproducibilidad de los Resultados , Azúcares
6.
Metabolomics ; 19(1): 4, 2022 12 28.
Artículo en Inglés | MEDLINE | ID: mdl-36576608

RESUMEN

INTRODUCTION: Feature annotation is crucial in untargeted metabolomics but remains a major challenge. The large pool of metabolites collected under various instrumental conditions is underrepresented in publicly available databases. Retention time (RT) and collision cross section (CCS) measurements from liquid chromatography ion mobility high-resolution mass spectrometers can be employed in addition to MS/MS spectra to improve the confidence of metabolite annotation. Recent advancements in machine learning focus on improving the accuracy of predictions for CCS and RT values. Therefore, high-quality experimental data are crucial to be used either as training datasets or as a reference for high-confidence matching. METHODS: This manuscript provides an easy-to-use workflow for the creation of an in-house metabolite library, offers an overview of alternative solutions, and discusses the challenges and advantages of using open-source software. A total of 100 metabolite standards from various classes were analyzed and subjected to the described workflow for library generation. RESULTS AND DISCUSSION: The outcome was an open-access available NIST format metabolite library (.msp) with multidimensional information. The library was used to evaluate CCS prediction tools, MS/MS spectra heterogeneities (e.g., multiple adducts, in-source fragmentation, radical fragment ions using collision-induced dissociation), and the reporting of RT.


Asunto(s)
Metabolómica , Espectrometría de Masas en Tándem , Metabolómica/métodos , Espectrometría de Masas en Tándem/métodos , Cromatografía Liquida/métodos , Programas Informáticos , Exactitud de los Datos
7.
J Sep Sci ; 45(15): 2935-2945, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35716100

RESUMEN

Lipidomics analysis of zebrafish tissues has shown promising results to understand disease-related outcomes of exposure to toxic substances at a molecular level. However, knowledge about their lipidome is limited, as most untargeted studies only identify the lipids that are statistically significant in their setup. In this work, liquid chromatography-high resolution mass spectrometry was used to study different aspects of the analytical workflow, that is, extraction solvents (methanol/chloroform/water (3/2/2, v/v/v), methanol/dichloromethane/water (2/3/2, v/v/v) and methanol/methyl-tert-butyl ether/water (3/10/2.5, v/v/v), instrumental response, and strategies used for lipid annotation. The number of high-quality features (relative standard deviation of the intensity values ≤ 10% in the range 103 -107 counts) was affected by the dilution of lipid extracts, indicating that it is an important parameter for developing untargeted methods. The workflows used allowed the selection of a dilution factor to annotate 712 lipid species (507 bulk lipids) in zebrafish liver using four software (LipidMatch, LipidHunter, MS-DIAL, and Lipostar). Retention time mapping was a valuable tool to filter lipid annotations obtained from automatic software annotations. The lipid profiling of zebrafish livers will help in a better understanding of the true constitution of their lipidome at the species level, as well as in the use of zebrafish in toxicological studies.


Asunto(s)
Lipidómica , Pez Cebra , Animales , Cromatografía Liquida/métodos , Lípidos/análisis , Hígado/química , Espectrometría de Masas/métodos , Metanol , Agua
8.
J Proteome Res ; 21(4): 1153-1166, 2022 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-35274962

RESUMEN

Alcoholic liver disease is highly prevalent but poorly identified and characterized, leading to knowledge gaps, which impairs early diagnosis. Excessive alcohol consumption is known to alter lipid metabolism, followed by progressive intracellular lipid accumulation, resulting in alcoholic fatty liver disease. In this study, HepaRG cells were exposed to ethanol at IC10 and 1/10 IC10 for 24 and 48 h. Metabolic alterations were investigated intra- and extracellularly with liquid chromatography-high-resolution mass spectrometry. Ion mobility was added as an extra separation dimension for untargeted lipidomics to improve annotation confidence. Distinctive patterns between exposed and control cells were consistently observed, with intracellular upregulation of di- and triglycerides, downregulation of phosphatidylcholines and phosphatidylethanolamines, sphingomyelins, and S-adenosylmethionine, among others. Several intracellular metabolic patterns could be related to changes in the extracellular environment, such as increased intracellular hydrolysis of sphingomyelins, leading to increased phosphorylcholine secretion. Carnitines showed alterations depending on the size of their carbon chain, which highlights the interplay between ß-oxidation in mitochondria and peroxisomes. Potential new biomarkers of ethanol-induced hepatotoxicity have been observed, such as ceramides with a sphingadienine backbone, octanoylcarnitine, creatine, acetylcholine, and ethoxylated phosphorylcholine. The combination of the metabolic fingerprint and footprint enabled a comprehensive investigation of the pathophysiology behind ethanol-induced hepatotoxicity.


Asunto(s)
Enfermedad Hepática Inducida por Sustancias y Drogas , Etanol , Cromatografía Liquida/métodos , Etanol/toxicidad , Humanos , Espectrometría de Masas , Metabolómica/métodos
9.
Drug Test Anal ; 13(6): 1219-1222, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33395730

RESUMEN

Phosphatidylethanol 16:0/18:1 (PEth) is the most abundant homologue of the phosphatidylethanol group of phospholipids. Formed only in the presence of ethanol, PEth is used as a biomarker in whole blood to provide information about the consumption of alcohol. As information on the storage life of PEth is essential for its beneficial use as a biomarker, this study investigated the stability of PEth in spiked and authentic whole blood samples stored at 4°C. Human whole blood samples (n = 23) and spiked whole blood samples (n = 7) with a concentration range between 5 and 2000 ng/ml were analysed at specific time intervals, up to 90 days. Differences were evident between the stability of authentic and spiked samples. PEth was stable at 4°C for 60 days (concentrations within 15% of initial concentration) in authentic samples, whereas spiked samples were stable for up to 30 days. This study emphasizes the importance of including authentic samples in stability experiments.


Asunto(s)
Biomarcadores/sangre , Glicerofosfolípidos/sangre , Manejo de Especímenes/métodos , Biomarcadores/análisis , Glicerofosfolípidos/análisis , Humanos , Temperatura , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...