Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 356
Filtrar
1.
Nan Fang Yi Ke Da Xue Xue Bao ; 44(6): 1198-1208, 2024 Jun 20.
Artículo en Chino | MEDLINE | ID: mdl-38977351

RESUMEN

OBJECTIVE: We propose a motion artifact correction algorithm (DMBL) for reducing motion artifacts in reconstructed dental cone-beam computed tomography (CBCT) images based on deep blur learning. METHODS: A blur encoder was used to extract motion-related degradation features to model the degradation process caused by motion, and the obtained motion degradation features were imported in the artifact correction module for artifact removal. The artifact correction module adopts a joint learning framework for image blur removal and image blur simulation for treatment of spatially varying and random motion patterns. Comparative experiments were conducted to verify the effectiveness of the proposed method using both simulated motion data sets and clinical data sets. RESULTS: The experimental results with the simulated dataset showed that compared with the existing methods, the PSNR of the proposed method increased by 2.88%, the SSIM increased by 0.89%, and the RMSE decreased by 10.58%. The results with the clinical dataset showed that the proposed method achieved the highest expert level with a subjective image quality score of 4.417 (in a 5-point scale), significantly higher than those of the comparison methods. CONCLUSION: The proposed DMBL algorithm with a deep blur joint learning network structure can effectively reduce motion artifacts in dental CBCT images and achieve high-quality image restoration.


Asunto(s)
Algoritmos , Artefactos , Tomografía Computarizada de Haz Cónico , Aprendizaje Profundo , Tomografía Computarizada de Haz Cónico/métodos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Movimiento (Física)
2.
Pol J Radiol ; 89: e281-e291, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39040560

RESUMEN

Purpose: We aimed to compare the diagnostic performance of different cone-beam computed tomography (CBCT) scan modes with and without the application of a metal artifact reduction (MAR) option under 5 different restorative materials. Material and methods: Our research was an in vitro study with 150 caries-free premolars and molars. The teeth were randomly divided into experimental (with artificially induced caries, n = 75) and control (without caries, n = 75) groups and were prepared based on 5 types of restorative materials, including conventional composites (Filtek Z250, Gradia), flow composite, glass ionomer, and amalgam. The teeth were examined under 2 CBCT scan modes (high-resolution [HIRes] and standard) with and without MAR application. Finally, the diagnostic accuracy index values (area under the receiver operating characteristic curve [AUC], sensitivity, and specificity) were calculated. Results: The AUC of standard scan mode with the MAR option was significantly lower than that of HIRes with MAR (p = 0.018) and without MAR option (p = 0.011) in detecting recurrent caries. Also, without MAR option, the diagnostic accuracy (AUC) of the standard mode was significantly lower than that of the HIRes (p = 0.020). Similar findings were observed for sensitivity and specificity. Moreover, diagnostic performance of standard and HIRes scan modes with and without MAR in the amalgam group was lower than that in other restorative material groups. Conclusions: Diagnostic performance of HIRes CBCT mode was higher than that of standard mode for recurrent caries and remained unaffected by MAR application. However, the accuracy in detecting recurrent caries was lower in the amalgam group compared with other restorative material groups.

3.
Artículo en Inglés | MEDLINE | ID: mdl-39027211

RESUMEN

This research aimed to introduce an auto-adaptive metal artifact reduction (aMAR) algorithm in cone-beam computed tomography (CBCT) to assess the levels of the pre-implant alveolar crest. Dental implants as a treatment modality for edentulous patients consist of a titanium alloy, which creates a metal artifact, resulting in a dark dental structure in the CBCT scans. Metallic artifacts are limiting factors for the precise detection in CBCT images. These are related to the dark areas around materials and metallic structures (e.g., restorations, implants, and endodontic instruments). To overcome this problem, the metal artifact reduction (MAR) program has been recommended as a post-procedure stage for CBCT image reconstruction. Recent developments offer CBCT scanners with an aMAR option with a greater dynamic range to help overcome the challenges of peri-implant bone evaluation to reach accurate dental diagnoses.

4.
Neural Netw ; 179: 106555, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39068676

RESUMEN

Lossy image coding techniques usually result in various undesirable compression artifacts. Recently, deep convolutional neural networks have seen encouraging advances in compression artifact reduction. However, most of them focus on the restoration of the luma channel without considering the chroma components. Besides, most deep convolutional neural networks are hard to deploy in practical applications because of their high model complexity. In this article, we propose a dual-stage feedback network (DSFN) for lightweight color image compression artifact reduction. Specifically, we propose a novel curriculum learning strategy to drive a DSFN to reduce color image compression artifacts in a luma-to-RGB manner. In the first stage, the DSFN is dedicated to reconstructing the luma channel, whose high-level features containing rich structural information are then rerouted to the second stage by a feedback connection to guide the RGB image restoration. Furthermore, we present a novel enhanced feedback block for efficient high-level feature extraction, in which an adaptive iterative self-refinement module is carefully designed to refine the low-level features progressively, and an enhanced separable convolution is advanced to exploit multiscale image information fully. Extensive experiments show the notable advantage of our DSFN over several state-of-the-art methods in both quantitative indices and visual effects with lower model complexity.

5.
J Clin Med ; 13(13)2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38999312

RESUMEN

Background: The electrodes of implantable cardiac devices (ICDs) may cause significant problems in cardiac computed tomography (CT) because they are a source of artifacts that obscure surrounding structures and possible pathology. There are a few million patients currently with ICDs, and some of these patients will require cardiac imaging due to coronary artery disease or problems with ICDs. Modern CT scanners can reduce some of the metal artifacts because of MAR software, but in some vendors, it does not work with ECG gating. Introduced in 2008, dual-energy CT scanners can generate virtual monoenergetic images (VMIs), which are much less susceptible to metal artifacts than standard CT images. Objective: This study aimed to evaluate if dual-energy CT can reduce metal artifacts caused by ICD leads by using VMIs. The second objective was to determine how the angle between the electrode and the plane of imaging affects the severity of the artifacts in three planes of imaging. Methods: A 3D-printed model was constructed to obtain a 0-90-degree field at 5-degree intervals between the electrode and each of the planes: axial, coronal, and sagittal. This electrode was scanned in dual-energy and single-energy protocols. VMIs with an energy of 40-140 keV with 10 keV intervals were reconstructed. The length of the two most extended artifacts originating from the tip of the electrode and 2 cm above it-at the point where the thick metallic defibrillating portion of the electrode begins-was measured. Results: For the sagittal plane, these observations were similar for both points of the ICDs that were used as the reference location. VMIs with an energy over 80 keV produce images with fewer artifacts than similar images obtained in the single-energy scanning mode. Conclusions: Virtual monoenergetic imaging techniques may reduce streak artifacts arising from ICD electrodes and improve the quality of the image. Increasing the angle of the electrode as well as the imaging plane can reduce artifacts. The angle between the electrode and the beam of X-rays can be increased by tilting the gantry of the scanner or lifting the upper body of the patient.

6.
Sci Rep ; 14(1): 16399, 2024 07 16.
Artículo en Inglés | MEDLINE | ID: mdl-39014057

RESUMEN

Metal artifacts notoriously pose significant challenge in computed tomography (CT), leading to inaccuracies in image formation and interpretation. Artifact reduction tools have been designed to improve cone beam computed tomography (CBCT) image quality by reducing artifacts caused by certain high-density materials. Metal artifact reduction (MAR) tools are specific algorithms that are applied during image reconstruction to minimize or eliminate artifacts degrading CBCT images. The purpose of the study is to evaluate the effect of a MAR algorithm on image quality in CBCT performed for evaluating patients before transarterial radioembolization (TARE). We retrospectively included 40 consecutive patients (aged 65 ± 13 years; 23 males) who underwent 45 CBCT examinations (Allura FD 20, XperCT Roll protocol, Philips Healthcare, Best, The Netherlands) in the setting of evaluation for TARE between January 2017 and December 2018. Artifacts caused by coils, catheters, and surgical clips were scored subjectively by four readers on a 5-point scale (1 = artifacts affecting diagnostic information to 5 = no artifacts) using a side-by-side display of uncorrected and MAR-corrected images. In addition, readers scored tumor visibility and vessel discrimination. MAR-corrected images were assigned higher scores, indicating better image quality. The differences between the measurements with and without MAR were most impressive for coils with a mean improvement of 1.6 points (95%CI [1.5 1.8]) on the 5-point likert scale, followed by catheters 1.4 points (95%CI [1.3 1.5]) and clips 0.7 points (95%CI [0.3 1.1]). Improvements for other artifact sources were consistent but relatively small (below 0.25 points on average). Interrater agreement was good to perfect (Kendall's W coefficient = 0.68-0.95) and was higher for MAR-corrected images, indicating that MAR improves diagnostic accuracy. A metal artifact reduction algorithm can improve diagnostic and interventional accuracy of cone beam CT in patients undergoing radioembolization by reducing artifacts caused by diagnostic catheters and coils, lowering interference of metal artifacts with adjacent major structures, and improving tumor visibility.


Asunto(s)
Algoritmos , Artefactos , Tomografía Computarizada de Haz Cónico , Metales , Humanos , Tomografía Computarizada de Haz Cónico/métodos , Femenino , Anciano , Masculino , Estudios Retrospectivos , Persona de Mediana Edad , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/diagnóstico por imagen , Embolización Terapéutica/métodos , Procesamiento de Imagen Asistido por Computador/métodos
7.
Comput Biol Med ; 179: 108873, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39053334

RESUMEN

Video-based remote photoplethysmography (rPPG) has emerged as a promising technology for non-contact vital sign monitoring, especially under controlled conditions. However, the accurate measurement of vital signs in real-world scenarios faces several challenges, including artifacts induced by videocodecs, low-light noise, degradation, low dynamic range, occlusions, and hardware and network constraints. In this article, a systematic and comprehensive investigation of these issues is conducted, measuring their detrimental effects on the quality of rPPG measurements. Additionally, practical strategies are proposed for mitigating these challenges to improve the dependability and resilience of video-based rPPG systems. Methods for effective biosignal recovery in the presence of network limitations are detailed, along with denoising and inpainting techniques aimed at preserving video frame integrity. Compared to previous studies, this paper addresses a broader range of variables and demonstrates improved accuracy across various rPPG methods, emphasizing generalizability for practical applications in diverse scenarios with varying data quality. Extensive evaluations and direct comparisons demonstrate the effectiveness of these approaches in enhancing rPPG measurements under challenging environments, contributing to the development of more reliable and effective remote vital sign monitoring technologies.


Asunto(s)
Artefactos , Fotopletismografía , Grabación en Video , Humanos , Fotopletismografía/métodos , Procesamiento de Señales Asistido por Computador , Masculino , Femenino , Adulto , Monitoreo Fisiológico/métodos
8.
Korean J Radiol ; 25(7): 662-672, 2024 07.
Artículo en Inglés | MEDLINE | ID: mdl-38942460

RESUMEN

Since the emergence of the first photon-counting computed tomography (PCCT) system in late 2021, its advantages and a wide range of applications in all fields of radiology have been demonstrated. Compared to standard energy-integrating detector-CT, PCCT allows for superior geometric dose efficiency in every examination. While this aspect by itself is groundbreaking, the advantages do not stop there. PCCT facilitates an unprecedented combination of ultra-high-resolution imaging without dose penalty or field-of-view restrictions, detector-based elimination of electronic noise, and ubiquitous multi-energy spectral information. Considering the high demands of orthopedic imaging for the visualization of minuscule details while simultaneously covering large portions of skeletal and soft tissue anatomy, no subspecialty may benefit more from this novel detector technology than musculoskeletal radiology. Deeply rooted in experimental and clinical research, this review article aims to provide an introduction to the cosmos of PCCT, explain its technical basics, and highlight the most promising applications for patient care, while also mentioning current limitations that need to be overcome.


Asunto(s)
Fotones , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Enfermedades Musculoesqueléticas/diagnóstico por imagen , Sistema Musculoesquelético/diagnóstico por imagen , Dosis de Radiación
9.
Artículo en Inglés | MEDLINE | ID: mdl-38836185

RESUMEN

In recent years, the importance of spectral CT scanners in clinical settings has significantly increased, necessitating the development of phantoms with spectral capabilities. This study introduces a dual-filament 3D printing technique for the fabrication of multi-material phantoms suitable for spectral CT, focusing particularly on creating realistic phantoms with orthopedic implants to mimic metal artifacts. Previously, we developed PixelPrint for creating patient-specific lung phantoms that accurately replicate lung properties through precise attenuation profiles and textures. This research extends PixelPrint's utility by incorporating a dual-filament printing approach, which merges materials such as calcium-doped Polylactic Acid (PLA) and metal-doped PLA, to emulate both soft tissue and bone, as well as orthopedic implants. The PixelPrint dual-filament technique utilizes an interleaved approach for material usage, whereby alternating lines of calcium-doped and metal-doped PLA are laid down. The development of specialized filament extruders and deposition mechanisms in this study allows for controlled layering of materials. The effectiveness of this technique was evaluated using various phantom types, including one with a dual filament orthopedic implant and another based on a human knee CT scan with a medical implant. Spectral CT scanner results demonstrated a high degree of similarity between the phantoms and the original patient scans in terms of texture, density, and the creation of realistic metal artifacts. The PixelPrint technology's ability to produce multi-material, lifelike phantoms present new opportunities for evaluating and developing metal artifact reduction (MAR) algorithms and strategies.

10.
Diagnostics (Basel) ; 14(12)2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38928694

RESUMEN

OBJECTIVE: This study aimed to assess the impact of artificial intelligence (AI)-driven noise reduction algorithms on metal artifacts and image quality parameters in cone-beam computed tomography (CBCT) images of the oral cavity. MATERIALS AND METHODS: This retrospective study included 70 patients, 61 of whom were analyzed after excluding those with severe motion artifacts. CBCT scans, performed using a Hyperion X9 PRO 13 × 10 CBCT machine, included images with dental implants, amalgam fillings, orthodontic appliances, root canal fillings, and crowns. Images were processed with the ClariCT.AI deep learning model (DLM) for noise reduction. Objective image quality was assessed using metrics such as the differentiation between voxel values (ΔVVs), the artifact index (AIx), and the contrast-to-noise ratio (CNR). Subjective assessments were performed by two experienced readers, who rated overall image quality and artifact intensity on predefined scales. RESULTS: Compared with native images, DLM reconstructions significantly reduced the AIx and increased the CNR (p < 0.001), indicating improved image clarity and artifact reduction. Subjective assessments also favored DLM images, with higher ratings for overall image quality and lower artifact intensity (p < 0.001). However, the ΔVV values were similar between the native and DLM images, indicating that while the DLM reduced noise, it maintained the overall density distribution. Orthodontic appliances produced the most pronounced artifacts, while implants generated the least. CONCLUSIONS: AI-based noise reduction using ClariCT.AI significantly enhances CBCT image quality by reducing noise and metal artifacts, thereby improving diagnostic accuracy and treatment planning. Further research with larger, multicenter cohorts is recommended to validate these findings.

11.
Artículo en Japonés | MEDLINE | ID: mdl-38777768

RESUMEN

PURPOSE: To validate the effects of subject position on single energy metal artifact reduction (SEMAR) of a reverse shoulder prosthesis using computed tomography (CT). METHODS: A water phantom with a reverse shoulder prosthesis was scanned at four positions on the XY plane of the CT gantry (on-center, 50 mm, 100 mm, and 150 mm from on-center in the negative direction of the X axis, respectively). We obtained images with and without SEMAR. The artifact index (AI) was measured via physical assessment. Scheffé's (Ura) paired comparison methods were performed with the amount of metal artifact by ten radiological technologists via visual assessment. RESULTS: The AI was significantly reduced when using SEMAR. As the phantom moved away from the on-center position, the AI increased, and metal artifacts increased in Scheffé's methods. CONCLUSION: SEMAR reduces metal artifacts of a reverse shoulder prosthesis, but metal artifacts may increase as the subject position moves away from the on-center position.

12.
Radiol Med ; 129(7): 1038-1047, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38743319

RESUMEN

Dual-energy CT stands out as a robust and innovative imaging modality, which has shown impressive advancements and increasing applications in musculoskeletal imaging. It allows to obtain detailed images with novel insights that were once the exclusive prerogative of magnetic resonance imaging. Attenuation data obtained by using different energy spectra enable to provide unique information about tissue characterization in addition to the well-established strengths of CT in the evaluation of bony structures. To understand clearly the potential of this imaging modality, radiologists must be aware of the technical complexity of this imaging tool, the different ways to acquire images and the several algorithms that can be applied in daily clinical practice and for research. Concerning musculoskeletal imaging, dual-energy CT has gained more and more space for evaluating crystal arthropathy, bone marrow edema, and soft tissue structures, including tendons and ligaments. This article aims to analyze and discuss the role of dual-energy CT in musculoskeletal imaging, exploring technical aspects, applications and clinical implications and possible perspectives of this technique.


Asunto(s)
Enfermedades Musculoesqueléticas , Imagen Radiográfica por Emisión de Doble Fotón , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Enfermedades Musculoesqueléticas/diagnóstico por imagen , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Sistema Musculoesquelético/diagnóstico por imagen , Algoritmos
13.
J Clin Med ; 13(8)2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38673712

RESUMEN

Background/Objectives: Advancements in oral imaging technology are continually shaping the landscape of dental diagnosis and treatment planning. Among these, photon-counting computed tomography (PCCT), introduced in 2021, has emerged as a promising, high-quality oral technology. Dental imaging typically requires a resolution beyond the standard CT systems achievable with the specialized cone-beam CT. PCCT can offer up to 100 µm resolution, improve soft-tissue contrast, and provide faster scanning times, which are crucial for detailed dental diagnosis and treatment planning. Using semiconductor detectors, PCCT produces sharper images and can potentially reduce the number of scans required, thereby decreasing patient radiation exposure. This review aimed to explore the potential benefits of PCCT in dental imaging. Methods: This review analyzed the literature on PCCT in dental imaging from January 2010 to February 2024, sourced from PubMed, Scopus, and Web of Science databases, focusing on high-resolution, patient safety, and diagnostic efficiency in dental structure assessment. We included English-language articles, case studies, letters, observational studies, and randomized controlled trials while excluding duplicates and studies unrelated to PCCT's application in dental imaging. Results: Studies have highlighted the superiority of PCCT in reducing artifacts, which are often problematic, compared to conventional CBCT and traditional CT scans, due to metallic dental implants, particularly when used with virtual monoenergetic imaging and iterative metal artifact reduction, thereby improving implant imaging. This review acknowledges limitations, such as the potential for overlooking other advanced imaging technologies, a narrow study timeframe, the lack of real-world clinical application data in this field, and costs. Conclusions: PCCT represents a promising advancement in dental imaging, offering high-resolution visuals, enhanced contrast, and rapid scanning with reduced radiation exposure.

14.
Magn Reson Imaging ; 111: 256-264, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38621551

RESUMEN

BACKGROUND: 3D multi-spectral imaging (MSI) of metal implants necessitates relatively long scan times. OBJECTIVE: We implemented a fast isotropic 3D MSI technique at 3 T and compared its image quality and clinical utility to non-isotropic MSI in the evaluation of hip implants. METHODS: Two musculoskeletal radiologists scored images from coronal proton density-weighted conventional MAVRIC-SL and an isotropic MAVRIC-SL sequence accelerated with robust-component-analysis on a 3-point scale (3: diagnostic, 2: moderately diagnostic, 1: non-diagnostic) for overall image quality, metal artifact, and visualization around femoral and acetabular components. Grades were compared using a signed Wilcoxon test. Images were evaluated for effusion, synovitis, osteolysis, loosening, pseudotumor, fracture, and gluteal tendon abnormalities. Reformatted axial and sagittal images for both sequences were subsequently generated and compared for image quality with the Wilcoxon test. Whether these reformats increased diagnostic confidence or revealed additional pathology, including findings unrelated to arthroplasty that may contribute to hip pain, was also compared using the McNemar test. Inter-rater agreement was measured by Cohen's kappa. RESULTS: 39 symptomatic patients with a total of 59 hip prostheses were imaged (mean age, 70 years ±9, 14 males, 25 females). Comparison scores between coronal images showed no significant difference in image quality, metal artifact, or visualization of the femur and acetabulum. Except for loosening, reviewers identified more positive cases of pathology on the original coronally-acquired isotropic sequence. In comparison of reformatted axial and sagittal images, the isotropic sequence scored significantly (p < 0.01) higher for overall image quality (3.0 vs 2.0) and produced significantly (p < 0.01) more cases of increased diagnostic confidence (42.4% vs 7.6%) or additional diagnoses (50.8% vs 22.9%). Inter-rater agreement was substantial (k = 0.798) for image quality. Mean scan times were 4.2 mins (isotropic) and 7.1 mins (non-isotropic). CONCLUSION: Compared to the non-isotropic sequence, isotropic 3D MSI was acquired in less time while maintaining diagnostically acceptable image quality. It identified more pathology, including postoperative complications and potential pain-generating pathology unrelated to arthroplasty. This fast isotropic 3D MSI sequence demonstrates promise for improving diagnostic evaluation of symptomatic hip prostheses at 3 T while simultaneously reducing scan time.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Imagenología Tridimensional , Imagen por Resonancia Magnética , Humanos , Masculino , Femenino , Anciano , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Imagenología Tridimensional/métodos , Artefactos , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Anciano de 80 o más Años , Reproducibilidad de los Resultados , Adulto
15.
Phys Med Biol ; 69(14)2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-38588680

RESUMEN

Objective.Metal artifacts in computed tomography (CT) images hinder diagnosis and treatment significantly. Specifically, dental cone-beam computed tomography (Dental CBCT) images are seriously contaminated by metal artifacts due to the widespread use of low tube voltages and the presence of various high-attenuation materials in dental structures. Existing supervised metal artifact reduction (MAR) methods mainly learn the mapping of artifact-affected images to clean images, while ignoring the modeling of the metal artifact generation process. Therefore, we propose the bidirectional artifact representations learning framework to adaptively encode metal artifacts caused by various dental implants and model the generation and elimination of metal artifacts, thereby improving MAR performance.Approach.Specifically, we introduce an efficient artifact encoder to extract multi-scale representations of metal artifacts from artifact-affected images. These extracted metal artifact representations are then bidirectionally embedded into both the metal artifact generator and the metal artifact eliminator, which can simultaneously improve the performance of artifact removal and artifact generation. The artifact eliminator learns artifact removal in a supervised manner, while the artifact generator learns artifact generation in an adversarial manner. To further improve the performance of the bidirectional task networks, we propose artifact consistency loss to align the consistency of images generated by the eliminator and the generator with or without embedding artifact representations.Main results.To validate the effectiveness of our algorithm, experiments are conducted on simulated and clinical datasets containing various dental metal morphologies. Quantitative metrics are calculated to evaluate the results of the simulation tests, which demonstrate b-MAR improvements of >1.4131 dB in PSNR, >0.3473 HU decrements in RMSE, and >0.0025 promotion in structural similarity index measurement over the current state-of-the-art MAR methods. All results indicate that the proposed b-MAR method can remove artifacts caused by various metal morphologies and restore the structural integrity of dental tissues effectively.Significance.The proposed b-MAR method strengthens the joint learning of the artifact removal process and the artifact generation process by bidirectionally embedding artifact representations, thereby improving the model's artifact removal performance. Compared with other comparison methods, b-MAR can robustly and effectively correct metal artifacts in dental CBCT images caused by different dental metals.


Asunto(s)
Artefactos , Tomografía Computarizada de Haz Cónico , Procesamiento de Imagen Asistido por Computador , Metales , Tomografía Computarizada de Haz Cónico/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Humanos
16.
IEEE J Transl Eng Health Med ; 12: 348-358, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38606390

RESUMEN

Wearable sensing has become a vital approach to cardiac health monitoring, and seismocardiography (SCG) is emerging as a promising technology in this field. However, the applicability of SCG is hindered by motion artifacts, including those encountered in practice of which the strongest source is walking. This holds back the translation of SCG to clinical settings. We therefore investigated techniques to enhance the quality of SCG signals in the presence of motion artifacts. To simulate ambulant recordings, we corrupted a clean SCG dataset with real-walking-vibrational noise. We decomposed the signal using several empirical-mode-decomposition methods and the maximum overlap discrete wavelet transform (MODWT). By combining MODWT, time-frequency masking, and nonnegative matrix factorization, we developed a novel algorithm which leveraged the vertical axis accelerometer to reduce walking vibrations in dorsoventral SCG. The accuracy and applicability of our method was verified using heart rate estimation. We used an interactive selection approach to improve estimation accuracy. The best decomposition method for reduction of motion artifact noise was the MODWT. Our algorithm improved heart rate estimation from 0.1 to 0.8 r-squared at -15 dB signal-to-noise ratio (SNR). Our method reduces motion artifacts in SCG signals up to a SNR of -19 dB without requiring any external assistance from electrocardiography (ECG). Such a standalone solution is directly applicable to the usage of SCG in daily life, as a content-rich replacement for other wearables in clinical settings, and other continuous monitoring scenarios. In applications with higher noise levels, ECG may be incorporated to further enhance SCG and extend its usable range. This work addresses the challenges posed by motion artifacts, enabling SCG to offer reliable cardiovascular insights in more difficult scenarios, and thereby facilitating wearable monitoring in daily life and the clinic.


Asunto(s)
Artefactos , Procesamiento de Señales Asistido por Computador , Electrocardiografía/métodos , Corazón , Movimiento (Física)
17.
Phys Med Biol ; 69(10)2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38593826

RESUMEN

Objective. Newer cone-beam computed tomography (CBCT) imaging systems offer reconstruction algorithms including metal artifact reduction (MAR) and extended field-of-view (eFoV) techniques to improve image quality. In this study a new CBCT imager, the new Varian HyperSight CBCT, is compared to fan-beam CT and two CBCT imagers installed in a ring-gantry and C-arm linear accelerator, respectively.Approach. The image quality was assessed for HyperSight CBCT which uses new hardware, including a large-size flat panel detector, and improved image reconstruction algorithms. The decrease of metal artifacts was quantified (structural similarity index measure (SSIM) and root-mean-squared error (RMSE)) when applying MAR reconstruction and iterative reconstruction for a dental and spine region using a head-and-neck phantom. The geometry and CT number accuracy of the eFoV reconstruction was evaluated outside the standard field-of-view (sFoV) on a large 3D-printed chest phantom. Phantom size dependency of CT numbers was evaluated on three cylindrical phantoms of increasing diameter. Signal-to-noise and contrast-to-noise were quantified on an abdominal phantom.Main results. In phantoms with streak artifacts, MAR showed comparable results for HyperSight CBCT and CT, with MAR increasing the SSIM (0.97-0.99) and decreasing the RMSE (62-55 HU) compared to iterative reconstruction without MAR. In addition, HyperSight CBCT showed better geometrical accuracy in the eFoV than CT (Jaccard Conformity Index increase of 0.02-0.03). However, the CT number accuracy outside the sFoV was lower than for CT. The maximum CT number variation between different phantom sizes was lower for the HyperSight CBCT imager (∼100 HU) compared to the two other CBCT imagers (∼200 HU), but not fully comparable to CT (∼50 HU).Significance. This study demonstrated the imaging performance of the new HyperSight CBCT imager and the potential of applying this CBCT system in more advanced scenarios by comparing the quality against fan-beam CT.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen , Tomografía Computarizada de Haz Cónico/instrumentación , Tomografía Computarizada de Haz Cónico/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Humanos , Artefactos , Control de Calidad
18.
Phys Imaging Radiat Oncol ; 29: 100566, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38487622

RESUMEN

Background and purpose: Dose calculation on cone-beam computed tomography (CBCT) images has been less accurate than on computed tomography (CT) images due to lower image quality and discrepancies in CT numbers for CBCT. As increasing interest arises in offline and online re-planning, dose calculation accuracy was evaluated for a novel CBCT imager integrated into a ring gantry treatment machine. Materials and methods: The new CBCT system allowed fast image acquisition (5.9 s) by using new hardware, including a large-size flat panel detector, and incorporated image-processing algorithms with iterative reconstruction techniques, leading to accurate CT numbers allowing dose calculation. In this study, CBCT- and CT-based dose calculations were compared based on three anthropomorphic phantoms, after CBCT-to-mass-density calibration was performed. Six plans were created on the CT scans covering various target locations and complexities, followed by CBCT to CT registrations, copying of contours, and re-calculation of the plans on the CBCT scans. Dose-volume histogram metrics for target volumes and organs-at-risk (OARs) were evaluated, and global gamma analyses were performed. Results: Target coverage differences were consistently below 1.2 %, demonstrating the agreement between CT and re-calculated CBCT dose distributions. Differences in Dmean for OARs were below 0.5 Gy for all plans, except for three OARs, which were below 0.8 Gy (<1.1 %). All plans had a 3 %/1mm gamma pass rate > 97 %. Conclusions: This study demonstrated comparable results between dose calculations performed on CBCT and CT acquisitions. The new CBCT system with enhanced image quality and CT number accuracy opens possibilities for off-line and on-line re-planning.

19.
Biomed Tech (Berl) ; 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38507674

RESUMEN

OBJECTIVES: Computerized breath sound based diagnostic methods are one of the emerging technologies gaining popularity in terms of detecting respiratory disorders. However, the breath sound signal used in such automated systems used to be too noisy, which affects the quality of the diagnostic interpretations. To address this problem, the proposed work presents the new hybrid approach to reject the noises from breath sound. METHODS: In this method, 80 chronic obstructive pulmonary disease (COPD), 75 asthmatics and 80 normal breath sounds were recorded from the participants of a hospital. Each of these breath sound data were decontaminated using hybrid method of Butterworth band-pass filter, transient artifact reduction algorithm and spectral subtraction algorithm. The study examined the algorithms noise rejection potential over each category of breath sound by estimating the noise rejection performance metrics, i.e., mean absolute error (MAE), mean square error (MSE), peak signal to noise ratio (PSNR), and signal to noise ratio (SNR). RESULTS: Using this algorithm, the study obtained a high value of SNR of 70 dB and that of PSNR of 72 dB. CONCLUSIONS: The study could definitely a suitable one to suppress noises and to produce noise free breath sound signal.

20.
J Med Ultrason (2001) ; 51(2): 169-183, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38480548

RESUMEN

PURPOSE: Vascular distribution is important information for diagnosing diseases and supporting surgery. Photoacoustic imaging is a technology that can image blood vessels noninvasively and with high resolution. In photoacoustic imaging, a hemispherical array sensor is especially suitable for measuring blood vessels running in various directions. However, as a hemispherical array sensor, a sparse array sensor is often used due to technical and cost issues, which causes artifacts in photoacoustic images. Therefore, in this study, we reduce these artifacts using deep learning technology to generate signals of virtual dense array sensors. METHODS: Generating 2D virtual array sensor signals using a 3D convolutional neural network (CNN) requires huge computational costs and is impractical. Therefore, we installed virtual sensors between the real sensors along the spiral pattern in three different directions and used a 2D CNN to generate signals of the virtual sensors in each direction. Then we reconstructed a photoacoustic image using the signals from both the real sensors and the virtual sensors. RESULTS: We evaluated the proposed method using simulation data and human palm measurement data. We found that these artifacts were significantly reduced in the images reconstructed using the proposed method, while the artifacts were strong in the images obtained only from the real sensor signals. CONCLUSION: Using the proposed method, we were able to significantly reduce artifacts, and as a result, it became possible to recognize deep blood vessels. In addition, the processing time of the proposed method was sufficiently applicable to clinical measurement.


Asunto(s)
Artefactos , Aprendizaje Profundo , Procesamiento de Imagen Asistido por Computador , Técnicas Fotoacústicas , Técnicas Fotoacústicas/métodos , Técnicas Fotoacústicas/instrumentación , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Mano/diagnóstico por imagen , Mano/irrigación sanguínea
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...