Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Thorac Oncol ; 16(4): 537-545, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33545385

RESUMEN

Biomarkers have various applications including disease detection, diagnosis, prognosis, prediction of response to intervention, and disease monitoring. In this era of precision medicine, having validated biomarkers to inform clinical decision making is more important than ever. In this article, we discuss best the practices and potential issues in biomarker discovery and validation. We encourage team science partnerships to bring cutting-edge discovery from bench to bedside, leading to improved patient care and outcomes.


Asunto(s)
Investigación Biomédica , Neoplasias Pulmonares , Biomarcadores , Humanos , Medicina de Precisión , Pronóstico
2.
J Chromatogr A ; 1625: 461263, 2020 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-32709319

RESUMEN

Polychlorinated dibenzo-p-dioxins and furans are environmentally persistent and highly toxic compounds. 136 chlorinated dioxins and furan congeners contain at least four chlorine atoms and pose a complex separation challenge in environmental and biological matrixes. The complexity arises from the dioxin and furan molecules with substitutions at positions 2, 3, 7, and 8, which are toxicologically relevant but are not easily separated from the other non-/less toxic congeners. Many regulatory methods require the use of two columns with different polarities or selectivity for dioxin analysis. The most common confirmation column pair is a (5% phenyl)-methylpolysiloxane and a (biscyanopropyl-/ cyanopropylphenyl)-methylpolysiloxane. These phases are required in USEPA-1613 for 2,3,7,8-tetrachlorodibenzo-p-dioxin and 2,3,7,8-tetrachlorodibenzofuran specificity. However, other column phases, such as the Rxi-17SilMS and the Rtx-Dioxin2, offer alternatives to the traditional column pairing and provide a similar or better separation of 2,3,7,8-substituted congeners. This study compares four columns for dioxin analysis: the Rtx-Dioxin2, Rxi-17SilMS, Rxi-5SilMS, and Rtx-2330. All columns used in this study are capable of meeting the requirements for dioxin analysis required by USEPA-1613. However, the Rtx-Dioxin2 demonstrated improved selectivity for a wider range of dioxin compounds than the Rxi-5SilMS. The Rtx-Dioxin2 is capable of resolving 2,3,7,8-tetrachlorodibenzo-p-dioxin and 2,3,7,8-tetrachlorodibenzofuran from common interferants better than the Rxi-5SilMS and can be used as a confirmation column with either the Rtx-2330 or Rxi-17SilMS.


Asunto(s)
Cromatografía de Gases/métodos , Dioxinas/análisis , Animales , Peces , Dibenzodioxinas Policloradas/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...