Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 105
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39288986

RESUMEN

BACKGROUND AND AIM: Although rapid on-site cytological evaluation (ROSE) for endoscopic ultrasound (EUS)-guided tissue acquisition (EUS-TA) may increase diagnostic yield, it is not widely available. Macroscopic on-site evaluation (MOSE) is an alternative modality although it is not standardized for EUS-guided fine-needle biopsy (FNB). We evaluated diagnostic performance of MOSE compared with conventional technique of EUS-TA using core biopsy needle. METHODS: Consecutive patients undergoing EUS-FNA for solid lesions were randomized to MOSE or conventional arms. The primary and secondary outcome measures were diagnostic accuracy, diagnostic yield, sensitivity, specificity, positive and negative predictive values, and the number of passes, respectively. The optimum parameters for macroscopic visible core (MVC, i.e., length, number) by MOSE to achieve accurate diagnosis were evaluated. RESULTS: Ninety-six patients (48 conventional and 48 MOSE) were enrolled. Mean lesion size was larger in MOSE arm (32.67 ± 7.22 vs 29.31 ± 6.98 mm, P = 0.023). Diagnostic accuracy (95.8% vs 91.6%), diagnostic yield (97.9% vs 95.8%), procedure duration, and adverse events of the two methods were similar. Median number of passes with MOSE was less (2 vs 3 P = 0.000). Area under the receiver operating characteristic curve showed that with MOSE, obtaining a total MVC length of 11.5 mm had 93.3% sensitivity, and 2.5 MVC cores (each 4 mm) had 86.7% sensitivity for malignancy diagnosis. CONCLUSIONS: EUS-FNB with MOSE, a simple reliable technique, can achieve a high and comparable diagnostic accuracy with lesser number of passes. Obtaining longer length and greater number of MVC increase the sensitivity to diagnose malignancy with MOSE.

2.
Diagnostics (Basel) ; 14(13)2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-39001226

RESUMEN

Despite the introduction of serological neoplastic biomarkers and typical radiological characteristics in clinical practice, liver biopsy (LB) is often still necessary to establish a histological diagnosis, especially in ambiguous cases. Nowadays, LB via the percutaneous approach (PC-LB), under computed tomography (CT) scan or ultrasonography (US) guidance, is the route of choice. However, certain focal liver lesions can be challenging to access percutaneously. In such cases, endoscopic ultrasound (EUS)-guided fine needle biopsy (FNB) may represent an attractive, minimally invasive alternative. This retrospective observational study aimed to evaluate the efficacy, diagnostic performance, and safety of EUS-FNB conducted on 58 focal liver lesions located in both liver lobes. The adequacy of FNB samples for focal liver lesions located in the left and right lobes was 100% and 81.2%, respectively, and the difference was statistically significant (p = 0.001). Technical success was 100% for both liver lobes. The overall sensitivity and specificity were 95% and 100%, respectively. EUS-FNB is effective in making an accurate diagnosis with an excellent safety profile for focal liver lesions located in both liver lobes.

3.
Endosc Ultrasound ; 13(1): 22-27, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38947121

RESUMEN

Background and Objectives: EUS-guided fine-needle biopsy (FNB) is an established technique for the acquisition of tissue to diagnose lesions of the gastrointestinal tract and surrounding organs. Recently, newer-generation FNB needles have been introduced, including a second-generation reverse-bevel and the third-generation fork-tip and Franseen needles. We aimed to determine if there was any difference between these needles in terms of cytopathological diagnostic yield, sample cellularity, or sample bloodiness. Methods: One hundred twenty-seven consecutive patients undergoing EUS-guided FNB of any solid lesion were randomized to use either a Franseen or fork-tip needle in a 1:1 ratio and were compared with 60 consecutive historical cases performed with reverse-bevel needles. Patient and procedure characteristics were recorded. Cases were reviewed by a blinded cytopathologist and graded based on cellularity and bloodiness. Overall diagnostic yield was calculated for each study arm. Results: One hundred seventy-six cases were eligible for analysis, including 109 pancreatic masses, 24 lymphoid lesions, 17 subepithelial lesions, and 26 other lesions. The final diagnosis was malignancy in 127 cases (72%). EUS-guided FNB was diagnostic in 141 cases (80%) overall and in 89% of cases where malignancy was the final diagnosis. There was no difference in diagnostic yield, sample cellularity, or sample bloodiness between the different needle types. There was no difference in adverse events between groups. Conclusions: EUS-guided FNB performed using 25-gauge Franseen, fork-tip, and reverse-bevel needles resulted in similar diagnostic yield, sample cellularity, and sample bloodiness. Our results may not be extrapolated to larger-caliber needles of the same design.

4.
Methods Mol Biol ; 2826: 15-30, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39017882

RESUMEN

Ultrasound-guided fine needle biopsy, also known as fine needle aspiration, of human axillary lymph nodes is a safe and effective procedure to assess the immune response within the lymph nodes following vaccination. Once acquired, lymph node cells can be characterized via flow cytometric immunophenotyping and/or single-cell RNA sequencing for gene expression and T and B cell receptors. Analysis of the immune cells from the lymph nodes enables the investigation of T and B cells that may interact at this site. These interactions may lead to germinal center formation and expansion, critical for the generation of effective immunity to vaccination. Directly studying the dynamic processes and interaction of the key cells has been challenging in humans due to the anatomically protected location of these cells. Here, we describe the methods involved in ultrasound-guided fine needle biopsy of human axillary lymph nodes in response to vaccination and subsequent analyses of the B cell populations.


Asunto(s)
Axila , Linfocitos B , Ganglios Linfáticos , Vacunación , Humanos , Ganglios Linfáticos/patología , Ganglios Linfáticos/inmunología , Linfocitos B/inmunología , Linfocitos B/metabolismo , Vacunación/métodos , Citometría de Flujo/métodos , Inmunofenotipificación , Biopsia con Aguja Fina/métodos , Biopsia Guiada por Imagen/métodos
5.
J Clin Med ; 13(14)2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-39064119

RESUMEN

Background: Several local regional anesthesia regimes have been described in the literature to reduce post-surgical pain following total knee arthroplasty (TKA), but it is unclear which regime has the best analgetic effect combined with the best motor function. The aim of this study was to determine if patients with infiltration between the popliteal artery and capsule of the posterior knee (IPACK) combined with an adductor canal block (SACB) had less pain, better motor function, and less opioid consumption after TKA than patients with a femoral nerve block (FNB) combined with a popliteal sciatic nerve block (PSB). Methods: In a retrospective cohort analysis, 342 patients following primary TKA were examined; 175 patients were treated with an IPACK combined with a SACB, and 167 patients with a femoral FNB combined with a PSB. The outcome parameters postoperative pain (visual analogue scale (VAS) for mobilization and at rest, functional recovery, opioid consumption, hospital discharge, and complications were analyzed and compared between both groups. Results: The IPACK/SACB group had a higher postoperative need for opioids despite higher doses of ropivacaine compared to the FNB/PSB group, accompanied by higher VAS scores. Patients' satisfaction was equal between the groups. Both groups showed comparable mobilization rates and walking distances following TKA. Conclusions: IPACK/SACB showed equal results compared to FNB/PSB for mobilization rates and patients' satisfaction following TKA without a reduction in opioid consumption.

6.
Diagnostics (Basel) ; 14(12)2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38928653

RESUMEN

BACKGROUND: The efficacy of endoscopic ultrasound-guided liver biopsy (EUS-LB) compared to percutaneous liver biopsy (PC-LB) remains uncertain. METHODS: Our data consist of randomized controlled trials (RCTs) comparing EUS-LB to PC-LB, found through a literature search via PubMed/Medline and Embase. The primary outcome was sample adequacy, whereas secondary outcomes were longest and total lengths of tissue specimens, diagnostic accuracy, and number of complete portal tracts (CPTs). RESULTS: Sample adequacy did not significantly differ between EUS-LB and PC-LB (risk ratio [RR] 1.18; 95% confidence interval [CI] 0.58-2.38; p = 0.65), with very low evidence quality and inadequate sample size as per trial sequential analysis (TSA). The two techniques were equivalent with respect to diagnostic accuracy (RR: 1; CI: 0.95-1.05; p = 0.88), mean number of complete portal tracts (mean difference: 2.29, -4.08 to 8.66; p = 0.48), and total specimen length (mean difference: -0.51, -20.92 to 19.9; p = 0.96). The mean maximum specimen length was significantly longer in the PC-LB group (mean difference: -3.11, -5.51 to -0.71; p = 0.01), and TSA showed that the required information size was reached. CONCLUSION: EUS-LB and PC-LB are comparable in terms of diagnostic performance although PC-LB provides longer non-fragmented specimens.

7.
Diagn Cytopathol ; 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38923863

RESUMEN

OBJECTIVE: Endoscopic ultrasound guide fine needle biopsy (EUS-FNB) is the main diagnostic tool for pancreatic adenocarcinoma. In most instances, only histology is obtained via FNB, without sending cytological slides. The aim of our study was to assess the additive diagnostic yield of cytology performed through FNB. METHODS: We conducted a retrospective study of all patients with histological diagnosis of pancreatic adenocarcinoma who were diagnosed by EUS-FNB. RESULTS: Overall, 80 patients were included in the study period. The overall concordance between cytology and histology all FNB needles was 78.2%. Notably, cytological assessment improved the diagnostic yield for malignancy by 12.8%. The overall kappa coefficient correlation between histology and cytology was .501, 95% CI 0.361-0.641. However, the kappa correlation for suspicious of malignancy and malignant was excellent of .872, 95% CI 0.733-1, suggesting that cytology is crucial when histology is inconclusive. Further analysis showed that the Acquire and Sharkcore needles outperformed the Procore needle in term of concordance between cytology and histology (kappa correlation of .527, 95% CI 0.331-0.724, .515, 95% CI 0.265-0.764, and .297, 95% CI -0.051-0.646), respectively. CONCLUSION: Performing cytology specimen when using FNB improves the diagnostic yield in pancreatic adenocarcinoma.

8.
Scand J Gastroenterol ; 59(8): 972-979, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38769625

RESUMEN

Objective: To quantitatively compare the diagnostic value of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) and endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) in solid pancreatic mass lesions using a systematic evaluation method.Methods: A systematic literature search was conducted on public databases to include studies comparing the diagnostic value of EUS-FNA and EUS-FNB in solid pancreatic mass lesions. The combined effect size was estimated using mean difference (MD) and risk difference (RD) respectively, and the corresponding 95% confidence interval (CI) was calculated.Results: The 12 articles (7 RCTs and 5 cohort studies) met the inclusion criteria of this study. The meta-analysis showed that compared with EUS-FNB, EUS-FNA had lower diagnostic accuracy (RD: -0.08, 95% CI: -0.15, -0.01) and specimen adequacy (RD: -0.08, 95% CI: -0.15, -0.02), while higher required number of needle passes (MD: 0.42, 95% CI: 0.12, 0.73). However, EUS-FNB and EUS-FNA presented similar overall complications (RD: 0.00, 95% CI: -0.01, 0.02) and technical failures (RD: -0.01, 95% CI: -0.02, 0.00), without statistically significant differences.Conclusions: Compared with EUS-FNA, EUS-FNB seems to be a better choice for diagnosing suspected pancreatic lesions.


Asunto(s)
Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico , Páncreas , Neoplasias Pancreáticas , Humanos , Neoplasias Pancreáticas/patología , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/diagnóstico , Páncreas/patología , Páncreas/diagnóstico por imagen , Estudios Prospectivos , Endosonografía/métodos
9.
Scand J Gastroenterol ; 59(7): 852-858, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38618997

RESUMEN

BACKGROUND AND AIMS: This pilot study aimed to evaluate safety and tissue sampling from subepithelial lesions (SEL) in the upper gastrointestinal tract with a novel electric motor driven endoscopic ultrasonography (EUS)-guided 17-gauge (G) size core needle biopsy (CNB) instrument. METHODS: An investigator-led prospective open label, performance and safety control study, including seven patients (female n = 4, median 71 y, range 28-75) with a determined SEL (median size 30 mm, range 17-150 mm) in the upper digestive tract (stomach n = 6, duodenum n = 1) were eligible and later followed up 14 days after index procedure. All investigations were completed according to protocol with three FNB 22-G passes with four fanning strokes and two EndoDrill® 17-G passes with three fanning strokes. RESULTS: Quality of samples as 'visible pieces' (>5 mm): FNB (n = 5/7) (fragmented/blood imbibed n = 1, poor tissue quantity n = 1) compared with 17-G CNB (n = 7/7). Histological result which led to final diagnosis (leiomyoma n = 2, adenocarcinoma n = 1, schwannoma n = 1, neuroendocrine tumour n = 1, desmoid tumour n = 1 and gastrointestinal stromal tumour (GIST) n = 1) could be obtained with the 17-G CNB instrument in all seven patients. FNB technique reached correct diagnosis in six patients. No serious adverse event were recorded. CONCLUSIONS: By using an electric driven 17-G biopsy device, a true cylinder of core tissue can be obtained in one single puncture from the area of interest reducing the need for a second sampling. The absolute benefit of EUS-guided CNB is that the sample can be handled and histologically prepared in the same manner as standard percutaneous core needle sample, e.g., breast and prostate cancer.


Asunto(s)
Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico , Humanos , Proyectos Piloto , Femenino , Persona de Mediana Edad , Anciano , Adulto , Estudios Prospectivos , Masculino , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/métodos , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/instrumentación , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/efectos adversos , Leiomioma/patología , Leiomioma/diagnóstico por imagen , Adenocarcinoma/patología , Adenocarcinoma/diagnóstico por imagen , Biopsia con Aguja Gruesa/métodos , Biopsia con Aguja Gruesa/efectos adversos , Neurilemoma/patología , Neurilemoma/diagnóstico por imagen , Duodeno/patología , Endosonografía/métodos , Estómago/patología
10.
Methods Mol Biol ; 2806: 91-100, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38676798

RESUMEN

Pancreatic cancer is associated with a high mortality rate, and there are still very few effective treatment options. Patient-derived xenografts have proven to be invaluable preclinical disease models to study cancer biology and facilitate testing of novel therapeutics. However, the severely immune-deficient mice used to generate standard models lack any functional immune system, thereby limiting their utility as a tool to investigate the tumor-immune cell interface. This chapter will outline a method for establishment of "humanized" patient-derived xenografts, which are reconstituted with human immune cells to imitate the immune-rich microenvironment of pancreatic cancer.


Asunto(s)
Modelos Animales de Enfermedad , Neoplasias Pancreáticas , Microambiente Tumoral , Neoplasias Pancreáticas/patología , Neoplasias Pancreáticas/inmunología , Neoplasias Pancreáticas/terapia , Animales , Humanos , Ratones , Microambiente Tumoral/inmunología , Ensayos Antitumor por Modelo de Xenoinjerto/métodos , Xenoinjertos , Ratones SCID
11.
Cancers (Basel) ; 16(4)2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38398152

RESUMEN

BACKGROUND AND AIMS: There is limited literature on sample adequacy for molecular testing in pancreatic ductal adenocarcinoma obtained via endoscopic ultrasound (EUS) fine-needle aspiration (FNA) versus EUS fine-needle biopsy (FNB). We aimed to compare these two modalities regarding sample adequacy for molecular and genomic sequencing. METHODS: We reviewed all patients with pancreatic ductal adenocarcinoma who underwent EUS at Saint Luke's Hospital from 2018 to 2021. The patients were categorized based on the method of EUS tissue acquisition, specifically FNA or FNB. A comprehensive evaluation was conducted for all cases by cytotechnologists. RESULTS: Out of 132 patients who underwent EUS-guided biopsies, 76 opted for FNA, 48 opted for FNB, and 8 opted for a combination of both. The average number of passes required for FNB and FNA was 2.58 ± 1.06 and 2.49 ± 1.07, respectively (p = 0.704), indicating no significant difference. Interestingly, 71.4% (35) of FNB-obtained samples were deemed adequate for molecular testing, surpassing the 32.1% (26) adequacy observed with FNA (p < 0.001). Additionally, 46.4% (26) of FNB-obtained samples were considered adequate for genomic testing, a notable improvement over the 23.8% (20) adequacy observed with FNA (p = 0.005). CONCLUSION: Although the number of passes required for cytologic diagnosis did not differ significantly between EUS-FNB and EUS-FNA, the former demonstrated superiority in obtaining samples adequate for molecular testing. Tumor surface area and cellularity were crucial parameters in determining sample adequacy for molecular testing, irrespective of the chosen tissue acquisition modality.

12.
Therap Adv Gastroenterol ; 17: 17562848231224943, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38250014

RESUMEN

Background: The impact of KRAS mutation testing on pancreatic ductal adenocarcinoma (PDAC) samples by endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) for reducing the need to repeat EUS-FNA has been demonstrated. Such testing however is not part of standard practice for endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB). Objectives: We aim to analyse the proportion of non-contributive samples by EUS-FNB and to evaluate the impact of KRAS mutation testing on the diagnosis, theranostics and survival. Design: In this retrospective study, the impact on diagnosis and survival of KRAS testing for contributive and non-contributive samples by EUS-FNB was analysed. Methods: The EUS-FNB samples, combined with KRAS testing using the Idylla® technique on liquid-based cytology from patients with PDAC between February 2019 and May 2023, were retrospectively reviewed. The cytology results were classified according to the guidelines of the World Health Organization System for Reporting Pancreaticobiliary Cytopathology (WHOSRPC). Results: A total of 85 EUS-FNB specimens were reviewed. In all, 25 EUS-FNB samples did not lead to a formal diagnosis of PDAC according to the WHOSRPC (30.2%). Out of these 25, 11 (44%) could have been considered positive for a PDAC diagnosis thanks to the KRAS mutation test without carrying out further diagnosis procedures. The sensitivity of KRAS mutation testing using the Idylla technique was 98.6%. According to the available data, survival rates were not statistically different depending on the type of mutation. Conclusion: KRAS mutation testing on liquid-based cytology using the Idylla or equivalent technique, combined with the PDAC EUS-FNB sample, should become a standard for diagnosis to avoid delaying treatment by doing another biopsy. Furthermore, knowledge of the KRAS status from treatment initiation could be used to isolate mutations requiring targeted treatments or inclusion in clinical research trials, especially for wild-type KRAS PDAC.


Diagnostic and theranostic interest of searching for a KRAS mutation in echoendoscopic ultrasound biopsies of pancreatic adenocarcinomas The echoendoscopic ultrasound diagnostic of pancreatic adenocarcinomas sometimes remains difficult due to the nature of these tumors with a particular microenvironment. For more than 30 years, several authors have underlined the importance of searching for a KRAS mutation on samples taken by echoendoscopic ultrasound to improve diagnostic performance. However, this research is not common practice. Our retrospective study made it possible to review the files of 85 patients with pancreatic adenocarcinoma in whom an echoendoscopic ultrasound biopsy was performed with a search for the KRAS mutation (with second-generation fine needle biopsy). Forty-four percent could have been considered positive for the diagnosis of PDAC thanks to the search for the KRAS mutation without repeating new samples. Furthermore, knowledge of the KRAS mutation type from diagnosis would make it possible to isolate mutations justifying possible targeted treatments.

13.
Pancreatology ; 24(1): 78-87, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38042675

RESUMEN

BACKGROUND: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) has high sensitivity for the pathological diagnosis of pancreatic masses, but also a high false-negative rate. K-ras gene mutations occur in over 75 % of pancreatic ductal adenocarcinomas (PDAC), and this meta-analysis evaluated the utility of detecting K-ras gene mutations from EUS-TA specimens for the diagnosis of PDAC. METHODS: Relevant studies in PubMed, the Cochrane Library, and Web of Science were systematically searched. Meta-analysis was performed on data from the selected studies using a bivariate model to provide pooled values of sensitivity, specificity, and their 95 % confidence intervals (CIs). RESULTS: This meta-analysis included 1521 patients (from 10 eligible studies) who underwent EUS-TA with K-ras gene mutation analysis for diagnosis of pancreatic solid masses. The pooled estimates of sensitivity and specificity were 76.6 % (95 % CI, 70.9-81.5 %) and 97.0 % (95 % CI, 94.0-98.5 %), respectively, for pathological diagnosis, 75.9 % (95 % CI 69.5-81.4 %) and 95.3 % (95 % CI, 92.3-97.2 %) for K-ras gene mutation analysis, and 88.7 % (95 % CI 87.1-91.7 %) and 94.9 % (95 % CI, 91.5-97.0 %) for pathological diagnosis in combination with K-ras gene mutation analysis. The sensitivity for diagnosis of PDAC was significantly higher for pathological diagnosis in combination with K-ras gene mutation analysis than for pathological diagnosis or K-ras gene mutation analysis alone (both, p < 0.001). There was no difference in specificity between pathological diagnosis in combination with K-ras gene mutation analysis and both either (p = 0.234, 0.945, respectively). CONCLUSIONS: K-ras gene mutation analysis in combination with to pathological diagnosis of EUS-TA increases the accuracy of differential diagnosis of PDAC.


Asunto(s)
Adenocarcinoma , Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Humanos , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/genética , Neoplasias Pancreáticas/patología , Genes ras/genética , Adenocarcinoma/diagnóstico por imagen , Adenocarcinoma/genética , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico , Carcinoma Ductal Pancreático/diagnóstico , Carcinoma Ductal Pancreático/genética , Mutación
14.
Scand J Gastroenterol ; 59(4): 496-502, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38126766

RESUMEN

Objective: Endoscopic ultrasound-guided fine-needle aspiration/biopsy (EUS FNA/FNB) and potential endoscopic retrograde cholangiopancreatography (ERCP) for biliary decompression are indicated in patients with pancreatic cancer before initation of primary chemotherapy. This study aims to investigate the performance and safety of these two procedures in patients with borderline resectable (BRPC) or locally advanced pancreatic cancer (LAPC). Methods: Endoscopy and pathology reports, and hospital records of consecutive patients with a radiological diagnosis of BRPC/LAPC included in a population based, protocol-driven study (NORPACT-2) were reviewed. Results: Of 251 patients, 223 (88.9%) underwent EUS-FNA/FNB, and 133 (53%) underwent ERCP. Repeated EUS attempts were performed in 33 (14.8%), eight (3.6%), and four (1.8%) patients. FNA was performed in 155 procedures, FNB in 30, and combined EUS-FNA/FNB in 83. Diagnostic accuracy was 86.1% for first EUS-FNA/FNB. The cumulative diagnostic accuracy for all attempts was 96%. False positive rate for malignancy was 0.9%. Of a total of 149 ERCP procedures, 122 (81.9%) were successful, and 27 (18.1%) were unsuccessful. Success rate of first ERCP attempt was 80.5% (107/133). Sixteen patients (12%) underwent a second attempt with a success rate of 93.8% (15 of 16). Combined EUS and ERCP was performed in 41 patients. Complications occurred in eight procedures (3%) after EUS-FNA/FNB, 23 procedures (15.3%) after ERCP, and four (9.8%) patients after combined EUS-FNA/FNB and ERCP. Conclusion: EUS-FNA/FNB and ERCP with biliary stenting in patients with BRPC/LAPC demonstrated acceptable performance and safety. Repeat procedures were performed with high success rates. Same session EUS-FNA/FNB and ERCP for biliary decompression is safe.


Asunto(s)
Adenocarcinoma , Neoplasias Pancreáticas , Humanos , Colangiopancreatografia Retrógrada Endoscópica/efectos adversos , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/efectos adversos , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/métodos , Estudios Prospectivos , Páncreas/patología , Neoplasias Pancreáticas/diagnóstico , Adenocarcinoma/patología , Estudios Retrospectivos
15.
Cytopathology ; 35(1): 70-77, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37905686

RESUMEN

Pancreatic carcinoma is an aggressive tumour with increasing incidence in both sexes worldwide. Early detection is, therefore, essential for patient management. A recent advancement involves the utilization of larger, thicker gauge needles, which enable the collection of core-type biopsies (FNB). Here, we investigated the role of fine needle aspiration and cytopathology in the diagnostic workflow of pancreatic lesions. A search query was designed to search for articles in the PubMed database comparing FNA and FNB for biopsy of pancreatic lesions, and detailed data were extracted from selected studies. Statistical analyses were performed using the R package meta version 6.2. Twenty-one studies made the final cut for data extraction. Overall, median age was 64.3 years (±6.1; 47.6-71.5), male: female proportion 53.9 (±11.3; 27.6-67.4), lesion size 3.1 cm (±0.5; 1.9-4.2 cm) and percentage of malignant cases 78.3% (±26.8; 2.1-100). FNA and FNB diagnostic yield was 85.8% (±10.3; 70.0-100.0) and 89.2% (±7.7; 70.0-98.6), respectively. Average accuracy was 89.5% (±11.7; 63.0-100.0) for FNA and 90.8% (±7.1; 77.0-100.0) for FNB. Adverse effects rate was 1.0% (±1.3; 0-4.3) for FNA and 2.2% (±4.4; 0-16.1) for FNB. None of the selected variables had a significant statistical difference between both methods. FNA and FNB perform similarly for diagnostic material acquisition in pancreatic lesions. The best outcome comes from the association of both techniques, emphasizing the value of combining cytological and histological morphology for the most accurate analysis.


Asunto(s)
Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico , Neoplasias Pancreáticas , Humanos , Masculino , Femenino , Persona de Mediana Edad , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/métodos , Páncreas/patología , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/patología , Biopsia con Aguja Gruesa
16.
Cytopathology ; 35(1): 92-97, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37698128

RESUMEN

INTRODUCTION: Endoscopic ultrasound-guided fine needle aspiration and biopsy (EUS-FNA, -FNB) are the mainstay for tissue diagnosis of pancreatic lesions. Traditionally, FNA was performed for obtaining cytology and also histology if available from the puncture. Since their advent, however, FNB needles have been intended mainly to obtain core biopsies for histological specimens. AIMS: We aimed to assess the yield of cytology obtained via both FNA and FNB needles. METHODS: A retrospective study was performed including all patients who were diagnosed with pancreatic adenocarcinoma obtained via EUS-FNA/FNB needles. RESULTS: Overall, 227 patients were included. Of them, 85 patients underwent FNB, versus 142 patients who had FNA. The average age in the FNB group was 70.46 ± 11.29 years, versus 71.44 ± 11.80 in the FNA group, P = 0.57. Notably, cytological analysis diagnosed malignancy equally in both groups (69.4% in the FNB group, vs. 65.5% in the FNA group). The compatibility rate of cytology with histology was 76.5% in the FNB group, versus 76.1% in the FNA group (P = 0.69). The agreement level between cytology obtained by FNA and FNB, versus histology obtained by both needles, was moderate (kappa = 0.48, 95% CI 0.39-0.57). Similarly, the agreement level between cytology and histology in the FNB group was moderate as well (kappa = 0.5, 95% CI 0.36-0.64). CONCLUSION: Cytological assessment yielded an equal performance as compared to histological assessment with both needles. We recommend obtaining cytology specimens in pancreatic solid lesion puncture by FNB needle.


Asunto(s)
Adenocarcinoma , Neoplasias Pancreáticas , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/patología , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico , Estudios Retrospectivos , Adenocarcinoma/diagnóstico , Adenocarcinoma/patología , Páncreas/patología
17.
J Mol Graph Model ; 126: 108644, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37832341

RESUMEN

In the process of degradation of aqueous fluoro-nitrobenzene (FNB) solution by titanium (Ti) electrode, the interaction between aqueous FNB solution and Ti electrode has an important impact on the performance and catalytic performance of electrode materials. The interaction involves complex physical, chemical and physical chemical processes, however, the mechanism of action is still unclear. In this study, Materials Studio software was used to design and construct molecular models of the interactions between aqueous FNB (p-, m-, o-FNB) solutions and Ti electrode, and molecular dynamics (MD) simulation was carried out in the absence of applied electric field and external electric field of 0.02 V/Å, respectively. Density functional theory (DFT) method was used to calculate the frontier molecular orbitals of three FNB molecules. Based on the calculation and analysis of the interaction energy (ΔE), diffusion coefficient (D) and radial distribution function (RDF), the interaction mechanism was discussed. It provides a theoretical basis for further research and development of Ti electrode degradation of fluorine compounds. The results showed that the order of ΔE between the three different aqueous FNB solutions and Ti surface is m-FNB > p-FNB > o-FNB when there is no external electric field. Under electric field of 0.02 V/Å, the order is p-FNB > m-FNB > o-FNB. The substitution position of F has an important effect on the HOMO of the nitro group and the LUMO of C-H in the three FNB molecules, and also affects the chemical reaction activity. In the model system, the diffusivity of different FNB solutions with electric field is less than that without electric field. The presence of an external electric field makes the diffusion of water and FNB molecules more orderly. The analysis results of RDF show that the bonding interactions between different FNB molecules and Ti surface is not much different before 3.5 Å, and all of them are weak. At about 8 Å, FNB molecule forms a non-bond with Ti electrode. ΔE, D and RDF of the model system can be changed by applying a certain external electric field, and the results are in better agreement with the experimental results.


Asunto(s)
Simulación de Dinámica Molecular , Titanio , Titanio/química , Agua/química , Electricidad , Electrodos
18.
Trials ; 24(1): 805, 2023 Dec 13.
Artículo en Inglés | MEDLINE | ID: mdl-38093381

RESUMEN

BACKGROUND: Studies have shown that the wet suction technique in endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) generates better histological diagnostic accuracy and specimen quality than the dry suction technique. However, conclusions of wet suction on the diagnostic accuracy of endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) are still controversial. Besides, the optimal number of passes for EUS-FNB has not been determined. We aimed to design a large multicenter randomized trial to compare the diagnostic accuracy of dry suction versus wet suction technique in solid pancreatic lesions (SPLs) using 22G Franseen needles and determine the optimal number of passes required for EUS-FNB. METHODS: This is a multi-center open-label, randomized controlled non-inferiority trial with two parallel groups. Two hundred patients with SPLs will undergo EUS-FNB using 22G Franseen needles in 4 tertiary hospitals in China and will be randomly assigned to the dry suction group and wet suction group in a ratio of 1:1. The primary endpoint is diagnostic accuracy. Secondary endpoints include the optimal number of needle passes, sensitivity, specificity, specimen quality, cytological diagnoses, time of the procedure, and incidence of complications. DISCUSSION: This study has been designed to determine (i) whether EUS-FNB using 22G Franseen needle with dry suction is non-inferior to wet suction in terms of diagnostic accuracy and (ii) the optimal number of passes during EUS-FNB of SPLs using 22G Franseen needle. TRIAL REGISTRATION: ClinicalTrials.gov NCT05549856. Registered on September 22, 2022.


Asunto(s)
Neoplasias Pancreáticas , Humanos , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/patología , Succión , Páncreas/patología , Biopsia Guiada por Imagen , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/métodos , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Multicéntricos como Asunto
19.
Front Immunol ; 14: 1197773, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37790931

RESUMEN

Neuroblastoma(NB) is the most common extracranial solid tumor in childhood, and it is now believed that some patients with NB have an underlying genetic susceptibility, which may be one of the reasons for the multiplicity of NB patients within a family line. Even within the same family, the samples show great variation and can present as ganglioneuroblastoma or even benign ganglioneuroma. The genomics of NB is still unclear and more in-depth studies are needed to reveal its key components. We first performed single-cell RNA sequencing(sc-RNAseq) analysis on clinical specimens of two family neuroblastoma(FNB) and four sporadic NB cases. A complete transcriptional profile of FNB was constructed from 18,394 cells from FNB, and we found that SDHD may be genetically associated with FNB and identified a prognostic related CAF subtype in FNB: Fib-4. Single-cell flux estimation analysis (scFEA) results showed that malignant cells were associated with arginine spermine, oxaloacetate and hypoxanthine, and that malignant cells metabolize lactate at lower levels than T cells. Our study provides new resources and ideas for the development of the genomics of family NB, and the mechanisms of cell-to-cell interactions and communication and the metabolic landscape will provide new therapeutic targets.


Asunto(s)
Ganglioneuroblastoma , Neuroblastoma , Humanos , Transcriptoma , Neuroblastoma/patología , Ganglioneuroblastoma/metabolismo , Pronóstico , Predisposición Genética a la Enfermedad
20.
J Clin Med ; 12(20)2023 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-37892755

RESUMEN

A pancreatic neuroendocrine tumor (Pan-NET) is a rare neoplasm originating in the neuroendocrine system. Carcinoid syndrome occurs in approximately 19% of patients with functional Pan-NETs, typically when liver metastases occur. In this paper, we describe the case of a patient with a low-grade non-functional Pan-NET, but with a typical clinical presentation of carcinoid syndrome. An 81-year-old male was admitted to our Department of Internal Medicine at Cannizzaro Hospital (Catania, Italy) because of the onset of abdominal pain with nausea, loose stools, and episodic flushing. Firstly, an abdominal contrast-enhanced CT scan showed a small pancreatic hyper-vascular mass; then, a gallium-68 DOTATOC integrated PET/CT revealed an elevated expression of SSTR receptors. Serum chromogranin A and urinary 5-HIAA measurements were negative. We performed an endoscopic ultrasonography (EUS) by a fine-needle biopsy (EUS-FNB), allowing the immunostaining of a small mass (0.8 cm) and the diagnosis of a low-grade (G1) non-functional Pan-NET (NF-Pan-NET). Surgery was waived, while a follow-up strategy was chosen. The early recognition of Pan-NETs, although rare, is necessary to improve the patient's survival. Although helpful to allow for immunostaining, EUS-FNB needs to be warranted in future studies comparing EUS-FNB to EUS-FNA (fine-needle aspiration), which is, to date, reported as the tool of choice to diagnose Pan-NETs.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...