Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Vasc Surg ; 79(6): 1295-1304.e2, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38280685

RESUMEN

OBJECTIVE: Persistent type II endoleaks (pEL2s) are not uncommon after endovascular aneurysm repair and their impact on long-term outcomes is well-documented. However, their occurrence and natural history after fenestrated/branched endografting (F/B-EVAR) for juxtarenal and pararenal aneurysms (J/P-AAAs) have been scarcely investigated. Aim of this study was to report incidence, risk factors, and natural history of pEL2 after F/B-EVAR in J/P-AAAs. METHODS: Between 2016 and 2022, all J/P-AAAs undergoing F/B-EVAR were prospectively collected and retrospectively analyzed. EL2 were assessed at the completion angiography, at 30 days and after 6 months as primary outcomes. Preoperative risk factors for pEL2, follow-up survival, freedom from reinterventions (FFR) and aneurysm shrinkage (≥5 mm) were considered as secondary outcomes. RESULTS: Of 132 patients, there were 88 (67%) JAAAs and 44 (33%) PAAAs. Seventeen EL2 (13%) were detected at the completion angiography and 36 (27%) at 30-day computed tomography angiography. The mean follow-up was 28 ± 23 months. Eleven (31%) EL2 sealed spontaneously within 6 months and three new cases were detected, for an overall of 28 pEL2/107 patients (26%) with available radiological follow-up of ≥6 months. Preoperative antiplatelet therapy (odds ratio, 4.7; 95% confidence interval [CI[, 1-22.1; P = .05), aneurysm thrombus volume of ≤40% and six or more patent aneurysm afferent vessels (odds ratio, 7.2; 95% CI, 1.8-29.1; P = .005) were independent risk factors for pEL2. The estimated 3-year survival was 80%, with no difference between cases with and without pEL2 (78% vs 85%; P = .08). The estimated 3-year FFR was 86%, with no difference between cases with and without pEL2 (81% vs 87%; P = .41). Four cases (3%) of EL2-related reinterventions were performed. In 65 cases (49%), aneurysm shrinkage was detected. pEL2 was an independent risk factor for absence of aneurysm shrinkage during follow-up (hazard ratio, 3.2; 95% CI, 1.2-8.3; P = .014). Patients without shrinkage had lower follow-up survival (64% vs 86% at 3-year; P = .009) and FFR (74% vs 90% at 3 years; P = .014) than patients with shrinkage. CONCLUSIONS: PEL2 is not infrequent (26%) after F/B-EVAR for J/P-AAAs and is correlated with preoperative antiplatelet therapy, aneurysm thrombus volume of ≤40%, and six or more patent sac afferent vessels. Patients with pEL2 have a diminished aneurysm shrinkage, which is correlated with lower follow-up survival and FFR compared with patients with aneurysm shrinkage.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Prótesis Vascular , Endofuga , Procedimientos Endovasculares , Humanos , Masculino , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Estudios Retrospectivos , Femenino , Factores de Riesgo , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Anciano , Endofuga/etiología , Endofuga/terapia , Endofuga/diagnóstico por imagen , Factores de Tiempo , Anciano de 80 o más Años , Incidencia , Medición de Riesgo , Resultado del Tratamiento , Diseño de Prótesis , Stents
2.
J Vasc Surg ; 79(5): 1101-1109, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38103807

RESUMEN

OBJECTIVE: To evaluate outcomes and performance of inverted limbs (ILs) when used in conjunction with Zenith fenestrated stent grafts (Zfens) to treat patients with short distance between the lowest renal artery (RA) and aortic or graft bifurcation (A/GB). METHODS: This study was a multicenter, retrospective review of prospectively maintained database of patients with complex aortic aneurysms, failed endovascular aneurysm repair (EVAR), or open surgical repair (OSR) with short distance between LRA and A/GB treated using a combination of Zfen and an IL between 2013 and 2023. Endpoints included technical success, aneurysm sac regression, long-term device integrity, and target vessel patency. We defined technical success as implantation of the device with no endoleak, conversion to an aorto-uni-iliac or OSR. RESULTS: During this time, 52 patients underwent endovascular rescue of failed repair. Twenty (38.5%) of them required relining of the failed repairs using IL due to lowest RA to A/GB length restrictions. Two patients had undergone rescue with a fenestrated cuff alone but developed type III endoleaks. One patient with no previous implant had a short distance between the lowest RA and aortic bifurcation to accommodate the bifurcated distal device, and two patients had failed OSR or anastomotic pseudoaneurysms. The majority (94%) were men with a mean age of 76.8 ± 6.1 years. The mean aortic neck diameter and aneurysm size were 32 ± 4 cm and 7.2 ± 1.3 cm, respectively. The median time laps between initial repair and failure was 36 months (interquartile range [IQR], 24-54 months). Sixteen patients (80%) were classified as American Society of Anesthesiologists class III, whereas four were class IV. Seventy-eight vessels were targeted and successfully incorporated. Technical success was 100%, and median estimated blood loss was 100 mL (IQR, 100-200 mL). Mean fluoroscopy time and dose were 61 ± 18 minutes and 2754 ± 1062 mGy, respectively. Average hospital length of stay was 2.75 ± 2.15 days. Postoperative complication occurred in one patient who required lower extremity fasciotomy for compartment syndrome. At a median follow-up of 50 months (IQR, 18-58 months), there were no device migration, components separation, aneurysmal related mortality, and type I or type III endoleak. Aneurysm sac regression (95%) or stabilization (5%) was observed in all patients, including in four patients (25%) with type II endoleak. CONCLUSIONS: The use of IL in conjunction with Zfen to treat patients with short distance between the lowest RA and A/GB is safe, effective, and has excellent long-term results. The technique expands the indication of Zfen, especially in patients with failed previous EVAR.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Médicos , Masculino , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Prótesis Vascular , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/etiología , Stents , Endofuga/etiología , Endofuga/cirugía , Factores de Riesgo , Resultado del Tratamiento , Diseño de Prótesis , Estudios Retrospectivos
3.
Eur J Vasc Endovasc Surg ; 65(5): 710-718, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36707021

RESUMEN

OBJECTIVE: Pararenal abdominal aortic aneurysms (p-AAA) require complex endovascular aortic repair or open surgical repair with suprarenal clamping. Custom made devices (CMD), including fenestrated and branched endovascular aortic repair (F/B-EVAR) or off the shelf (OTS) multibranched devices, are available treatment options. The aim of this study was to determine the additional healthy aortic coverage using an OTS multibranched endograft vs. a CMD for the treatment of p-AAAs. METHODS: This was a retrospective single centre analysis of prospectively collected data. Consecutive patients with p-AAAs requiring a proximal landing zone above the coeliac artery (CA), planned and treated with CMDs (Zenith Fenestrated) between January 2017 and December 2021 were included in this study. Treatment with supracoeliac coverage using available OTS multibranched devices was simulated using available pre-operative images: T-Branch; E-nside; and TAMBE. Study endpoints included the need for additional proximal aortic coverage, and the number of the segmental arteries additionally covered proximally from the CA for OTS devices compared with CMDs. RESULTS: Eighty three patients with p-AAAs were treated with CMDs (all FEVAR), including juxtarenal AAAs (n = 46; 56%), suprarenal AAAs (n = 20; 24%), and short neck AAAs (n = 17; 20%). In this study, treatment with 249 (3 × 83) OTS endografts was simulated. When compared with CMDs, OTS devices required a mean of 74 ± 19 mm of additional proximal healthy aortic coverage from the CA (CMD: 33 ± 19 mm vs. OTS: 108 ± 6 mm; p ≤ .001), as well as an average sacrifice of 2.5 additional segmental arteries (CMD: 1.3 ± 0.8 vs. OTS: 3.8 ± 0.9; p ≤ .001). In 94% of patients, at least one of the available multibranched endografts could have been implanted in accordance with instructions for use. CONCLUSION: Despite not requiring customisation time, OTS endografts for the treatment of p-AAA lead to more extensive healthy aortic coverage, as well as an average sacrifice of 2.5 additional segmental arteries, compared with CMDs. When compared with OTS devices, CMDs appear to limit the extent of unnecessary aortic coverage and the theoretical subsequent risk of spinal cord ischaemia.


Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Aneurisma de la Aorta Torácica/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Procedimientos Endovasculares/efectos adversos , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Diseño de Prótesis
4.
Eur J Vasc Endovasc Surg ; 64(6): 630-638, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35764243

RESUMEN

OBJECTIVE: Fenestrated and branched endografting (F/B-EVAR) has been proposed as an endovascular solution for chronic post-dissection thoraco-abdominal aneurysms (PD-TAAAs). The aim of this study was to analyse the experience of four high volume centres nationwide and the current available literature. METHODS: Data on patients undergoing F/B-EVAR in four Italian academic centres between 2008 and 2019 were collected, and those from patients with PD-TAAAs were analysed retrospectively. Peri-operative morbidity and mortality were assessed as early outcomes. Survival, freedom from re-intervention (FFR), target visceral vessel (TVV) patency, and aortic remodelling were assessed as follow up outcomes. A MEDLINE search was performed for studies published from 2008 to 2020 reporting on F/B-EVAR in PD-TAAAs. RESULTS: Among 351 patients who underwent F/B-EVAR for TAAAs, 37 (11%) had PD-TAAAs (Crawford's extent I-III: 35% - 95%). Overall, 135 TVVs (from true lumen 120; false lumen seven; both true and false lumen eight) were accommodated by fenestrations (96% - 71%) and branches (39% - 29%). Technical success (TS) was achieved in 34 (92%) cases with three failures due to endoleaks (Ia: 1; Ic: 1; III: 1). There were no 30 day deaths. No cases of permanent spinal cord ischaemia (SCI) were recorded and six (16%) patients suffered from transient deficits. Renal function worsening (eGFR < 30% than baseline) and pulmonary complications were reported in two (5%) and four (11%) cases, respectively. From the Kaplan-Meier analysis, three year survival, FFR, and TVV patency were 81%, 66%, and 97%, respectively. Radiological imaging was available for 30 (81%) patients at 12 months with complete false lumen thrombosis in 26 (87%). Two hundred and fifty-six patients were reported in seven published papers with TS, 30 day mortality, and SCI ranging from 99% to 100%, 0 to 6%, and 0 to 16%, respectively. The mean follow up ranged from 12 to 26 months, with estimated two year survival between 81% and 90% and a re-intervention rate between 19% and 53%. CONCLUSION: F/B-EVAR is effective to treat PD-TAAAs. A high re-intervention rate is necessary to complete the aneurysm exclusion and promote aortic remodelling successfully.


Asunto(s)
Aneurisma , Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Isquemia de la Médula Espinal , Humanos , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Estudios Retrospectivos , Diseño de Prótesis , Resultado del Tratamiento , Factores de Riesgo , Aneurisma/cirugía , Isquemia de la Médula Espinal/cirugía , Estudios Multicéntricos como Asunto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...