Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Acta Ophthalmol ; 100(3): e798-e806, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34250739

RESUMEN

PURPOSE: To assess retinal vascular involvement in patients with autosomal dominant optic atrophy (ADOA) genetically confirmed by the presence of the OPA1 (Optic Atrophy 1) gene mutation using a multimodal protocol of investigation of retinal posterior pole. METHODS: In this cross-sectional, case-control, observational study, both eyes of 13 patients with a genetic diagnosis of ADOA were compared with both eyes of 13 healthy controls (HCs). All subjects underwent full ophthalmological examination, spectral domain-optical coherence tomography (SD-OCT), fundus perimetry (FP) and OCT angiography (OCTA). RESULTS: Vessel density (VD) of the superficial and deep macular vascular plexi and of the radial peripapillary capillary plexus were significantly decreased (p ≤ 0.001) in ADOA patients compared with HCs. The area under the receiver operating characteristics analysis also revealed high values of sensitivity and specificity of OCTA parameters in distinguish between patients and HCs. A strong correlation (Pearson Coefficient, r = 0.91) emerged between OCTA VD of the superficial retinal plexus and the average Ganglion Cell Layer (GCL) thickness as measured by SD-OCT; a slightly lower correlation (Pearson Coefficient, r = 0.89) was also found between VD of the deep plexus and the average GCL thickness of the same eyes in patients with ADOA. The correlation among values of differential light sensitivity (DLS) measured by FP with VD and GCL thickness parameters was also investigated. The correlation analysis among DLS and the VD parameters showed from low-to-moderate correlation (ranging from r = 0.29 for the deep fovea VD to r = 0.59 for the deep whole image VD). The correlation coefficient between the mean DLS and the average thickness of GCL was more significant (Pearson Coefficient, r = 0.75). A significant correlation emerged also between the VD and the visual acuity, in terms of LogMAR BCVA (best-corrected visual acuity), especially for the VD of the deep capillary plexus (Pearson Coefficient for the Deep whole Image VD and LogMAR BCVA r = -0.75; for the Deep parafovea VD and LogMAR BCVA r = -0.78). CONCLUSION: Retinal microvascular assessment by OCTA angiography can provide relevant clinical information on retinal involvement in ADOA patients. In patients with genetically confirmed OPA1-related ADOA, there is a decrease in retinal vessel density associated with GCL thinning and DLS reduction.


Asunto(s)
Atrofia Óptica Autosómica Dominante , Angiografía , Estudios Transversales , Angiografía con Fluoresceína/métodos , Humanos , Atrofia Óptica Autosómica Dominante/diagnóstico , Atrofia Óptica Autosómica Dominante/genética , Retina , Vasos Retinianos , Tomografía de Coherencia Óptica/métodos
2.
J Clin Med ; 10(19)2021 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-34640347

RESUMEN

Screening programs may be useful to reduce the rate of undetected glaucoma. Compass (CMP, CenterVue, Padova, Italy) Standard Suprathreshold strategy (SST) analyses the visual function at 52 retinal locations. A new Quick Suprathreshold strategy (QST) reduces the number of tested locations to 24. With both tests, the CMP also provides an image of the central retina and a detail of the optic nerve head. The aim of this paper is to measure the performances of SST and QST compared with clinical diagnosis. 63 consecutive healthy subjects and 60 consecutive patients with perimetric defects from glaucoma in both eyes were recruited. They received one test per eye (SST or QST in randomized order); results were classified into normal, suspect and abnormal according to a global index provided in the report and called SupraThreshold Response (STR). Agreement between clinical diagnosis and test output were calculated, and test time was also measured. The agreement with the clinical diagnosis was 95.7% for SST and 95.1% for QST. When two suspect tests were excluded, agreement for QST increased to 96.7%. Test duration was 164 ± 82 s for SST and 71 ± 41 s for QST (p < 0.0001). Such a difference was similar in both glaucoma patients (respectively 231 ± 65 s vs. 105 ± 33 s, p < 0.0001) and normal subjects (98 ± 17 and 39 ± 9 s, p < 0.0001). In conclusion, SST and QST showed similar, high agreement with clinical judgement. Morphological analysis is potentially helpful in further improving the clinical usefulness of suprathreshold tests. QST is characterized by a strong time saving compared with SST.

3.
Int J Mol Sci ; 22(19)2021 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-34639066

RESUMEN

Fundus perimetry is a new technique for evaluating the light sense in the retina in a point-to-point manner. Light sense is fundamentally different from visual acuity, which measures the threshold for discriminating and perceiving two points or lines, called the minimum cognoscible. The quality of measurement of retinal sensitivity has dramatically increased in the last decade, and the use of fundus perimetry is now gaining popularity. The latest model of fundus perimetry, MP-3, can be used for a wide range of measurements and has an advanced eye tracking system. High background illumination enables accurate measurement of mesopic retail sensitivity. Recent investigations have shown that neuronal damage precedes vascular abnormalities in diabetic retinopathy. The loss of retinal function has also been reported prior to morphological changes in the retina. In this review, the importance of measuring retinal sensitivity to evaluate visual function in the early stages of diabetic retinopathy was discussed. The usefulness of retinal sensitivity as an outcome measure in clinical trials for treatment modalities is also presented. The importance of fundus perimetry is promising and should be considered by both diabetes researchers and clinical ophthalmologists.


Asunto(s)
Retinopatía Diabética/diagnóstico , Pruebas del Campo Visual/métodos , Toma de Decisiones Clínicas , Neuropatías Diabéticas , Retinopatía Diabética/patología , Retinopatía Diabética/fisiopatología , Manejo de la Enfermedad , Fondo de Ojo , Humanos , Mácula Lútea/patología , Retina , Tomografía de Coherencia Óptica , Agudeza Visual , Pruebas del Campo Visual/normas , Campos Visuales
4.
BMC Ophthalmol ; 18(1): 191, 2018 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-30075758

RESUMEN

BACKGROUND: Fixation changes in glaucoma are generally overlooked, as they are not strikingly evident as in macular diseases. Fundus perimetry might give additional insights into this aspect, along with traditional perimetric measures. In this work we propose a novel method to quantify glaucomatous changes in fixation features as detected by fundus perimetry and relate them to the extent of glaucomatous damage. METHODS: We retrospectively analysed fixation data from 320 people (200 normal subjects and 120 with glaucoma) from the Preferred Retinal Locus (PRL) detection of a Compass perimeter. Fixation stability was measured as Bivariate Contour Ellipse Area (BCEA), and using two novel metrics: (1) Mean Euclidean Distance (MED) from the Preferred Retinal Locus, and (2) Sequential Euclidean Distance (SED) of sequential fixation locations. These measures were designed to capture the spread of fixation points, and the frequency of position changes during fixation, respectively. RESULTS: In the age corrected analysis, SED was significantly greater in glaucomatous subjects than controls (P = 0.002), but there was no difference in BCEA (P = 0.15) or MED (P = 0.054). Similarly, SED showed a significant association with Mean Deviation (P <  0.001), but neither BCEA nor MED were significantly correlated (P > 0.14 for both). CONCLUSION: Changes in the scanning pattern detected by SED are better than traditional measures of fixation spread (BCEA) for describing the changes in fixation stability observed in glaucoma.


Asunto(s)
Movimientos Oculares/fisiología , Fijación Ocular/fisiología , Glaucoma/fisiopatología , Agudeza Visual , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Pruebas del Campo Visual/métodos , Campos Visuales , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...