Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 223
Filtrar
1.
Sci Total Environ ; 950: 175344, 2024 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-39117207

RESUMEN

The widespread dissemination of carbapenem-resistant bacteria in wastewater systems, particularly from clinical sources, poses a significant public health risk. This study assessed the concentrations and distributions of extracellular DNA (exDNA) and intracellular DNA (iDNA) harboring carbapenemase genes in wastewater from six tertiary care hospitals in Germany. We collected a total of 36 samples, comprising six biological replicates from each hospital, and analysed them using quantitative real-time PCR (qPCR) and digital PCR (dPCR). The analysis targeted seven carbapenemase genes: blaNDM, blaKPC, blaIMP, blaVIM, blaOXA-23-like, blaOXA-48-like, and blaOXA-58-like across both DNA fractions. Our results revealed significant variability in the concentrations of exDNA and iDNA across the sampling sites, with iDNA typically present at higher concentrations. Using NanoDrop One spectrophotometry and the Qubit dsDNA kit, exDNA concentrations ranged from 2.7 to 7.7 ng/mL, while Qubit recorded lower values between 1.1 and 4.0 ng/mL. Conversely, iDNA concentrations were markedly higher, spanning from 42.3 to 191.7 ng/mL with NanoDrop and 12.0 to 46.5 ng/mL with Qubit, highlighting the variability between DNA types and quantification methods. Despite its lower concentrations, exDNA comprised up to 18.2 % of total DNA, highlighting its potential role in the horizontal transfer of antimicrobial resistance genes (ARGs). The study detected target ARGs in both DNA fractions at all sites, with notable differences in their concentrations; iDNA consistently exhibited higher levels of ARGs, with the highest concentrations reaching 10.57 ± 0.20 log gene copies per liter (GC/L) for blaVIM in iDNA and 6.96 ± 0.72 log GC/L for blaIMP in exDNA. dPCR demonstrated greater sensitivity than qPCR, especially effective for detecting low-abundance targets like blaOXA-23-like in the exDNA fraction. Additionally, qPCR's susceptibility to inhibition and contamination emphasizes the superior robustness of dPCR. This research highlights the need for improved monitoring and the implementation of advanced treatment technologies to mitigate ARG dissemination in wastewater.


Asunto(s)
Proteínas Bacterianas , Reacción en Cadena en Tiempo Real de la Polimerasa , Aguas Residuales , beta-Lactamasas , Aguas Residuales/microbiología , beta-Lactamasas/genética , Proteínas Bacterianas/genética , ADN Bacteriano , Alemania , Monitoreo del Ambiente/métodos , Hospitales , Reacción en Cadena de la Polimerasa/métodos
2.
Environ Monit Assess ; 196(9): 820, 2024 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-39154115

RESUMEN

Drugs and related goods are widely used in order to promote public health and the quality of life. One of the most serious environmental challenges affecting public health is the ongoing presence of antibiotics in the effluents generated by pharmaceutical industries and hospitals. Antibiotics cannot be entirely removed from wastewater using the traditional wastewater treatment methods. Unmetabolized antibiotics generated by humans can be found in urban and livestock effluent. The antibiotic present in effluent contributes to issues with resistance to antibiotics and the creation of superbugs. Over the recent 2 years, the coronavirus disease 2019 pandemic has substantially boosted hospital waste volume. In this situation, a detailed literature review was conducted to highlight the harmful effects of untreated hospital waste and outline the best approaches to manage it. Approximately 50 to 70% of the emerging contaminants prevalent in the hospital wastewater can be removed using traditional treatment strategies. This paper emphasizes the numerous treatment approaches for effectively eliminating emerging contaminants and antibiotics from hospital wastewater and provides an overview of global hospital wastewater legislation and guidelines on hospital wastewater administration. Around 90% of ECs might be eliminated by biological or physical treatment techniques when used in conjunction with modern oxidation techniques. According to this research, hybrid methods are the best approach for removing antibiotics and ECs from hospital wastewater. The document outlines the many features of effective hospital waste management and might be helpful during and after the coronavirus disease 2019 outbreak, when waste creation on all hospitals throughout the globe has considerably increased.


Asunto(s)
Antibacterianos , COVID-19 , Hospitales , Aguas Residuales , Aguas Residuales/química , COVID-19/epidemiología , Antibacterianos/análisis , Humanos , Contaminantes Químicos del Agua/análisis , Eliminación de Residuos Líquidos/métodos , Pandemias , SARS-CoV-2 , Monitoreo del Ambiente/métodos
3.
Antibiotics (Basel) ; 13(8)2024 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-39200012

RESUMEN

The problem of antimicrobial resistance (AMR) is not limited to the medical field but is also becoming prevalent on a global scale in the environmental field. Environmental water pollution caused by the discharge of wastewater into aquatic environments has caused concern in the context of the sustainable development of modern society. However, there have been few studies focused on the treatment of hospital wastewater, and the potential consequences of this remain unknown. This study evaluated the efficacy of the inactivation of antimicrobial-resistant bacteria (AMRB) and antimicrobial resistance genes (AMRGs) in model wastewater treatment plant (WWTP) wastewater and hospital effluent based on direct ultraviolet (UV) light irradiation provided by a conventional mercury lamp with a peak wavelength of 254 nm and an ultraviolet light-emitting diode (UV-LED) with a peak emission of 280 nm under test conditions in which the irradiance of both was adjusted to the same intensity. The overall results indicated that both UV- and UV-LED-mediated disinfection effectively inactivated the AMRB in both wastewater types (>99.9% after 1-3 min of UV and 3 min of UV-LED treatment). Additionally, AMRGs were also removed (0.2-1.4 log10 for UV 254 nm and 0.1-1.3 log10 for UV 280 nm), and notably, there was no statistically significant decrease (p < 0.05) in the AMRGs between the UV and UV-LED treatments. The results of this study highlight the importance of utilizing a local inactivation treatment directly for wastewater generated by a hospital prior to its flow into a WWTP as sewage. Although additional disinfection treatment at the WWTP is likely necessary to remove the entire quantity of AMRB and AMRGs, the present study contributes to a significant reduction in the loads of WWTP and urgent prevention of the spread of infectious diseases, thus alleviating the potential threat to the environment and human health risks associated with AMR problems.

4.
Environ Pollut ; 361: 124771, 2024 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-39168435

RESUMEN

Hospital wastewater is a major hotspot for the spread of antimicrobial resistance (AMR) in aquatic ecosystems. This study aimed to investigate the prevalence of antibiotic resistance genes (ARGs) and their correlation with crAssphage in a hospital wastewater treatment plant (HWWTP) and a receiving canal. Water samples were analyzed for 94 ARGs and crAssphage relative to the 16S rRNA using high-throughput quantitative polymerase chain reaction (HT-qPCR). Subsequently, 7 ARGs and crAssphage were selected and quantified using qPCR. The results showed that the detected genes ranged from 79 to 93 out of 95 genes. The raw wastewater (WW) samples had the highest gene diversity compared to the upstream canal, which had less diversity than downstream samples, as determined by HT-qPCR. The blaGES was the most abundant in WW samples, while qacEΔ1, merA, IS6100, tnpA, and IS26 showed high prevalence throughout the treatment processes. The concentrations of intI1, sul1, blaTEM,blaNDM,blaVIM,tetQ, mcr-1, crAssphage, and 16S rRNA, measured using qPCR, were the highest in WW and significantly reduced in treated water samples. Although some water quality parameters, such as total suspended solids and dissolved oxygen, did not significantly differ before and after treatment, removal efficiency ranged from 0.60 to 3.23 log reduction values (LRV). The highest LRV was observed for the tetQ, whereas the mcr-1 had the lowest LRV. Strong positive correlations among the absolute concentrations of ARGs and crAssphage were observed (Spearman's rho = 0.6-1.0), and biochemical oxygen demand correlated with blaTEM and blaVIM (Spearman's rho = 0.6). These results indicate that crAssphage and water quality could reflect the distribution of other ARGs throughout the HWWTP. Further studies are needed to underscore the importance of monitoring ARGs and genetic markers such as crAssphage in HWWTPs and their receiving waters to enhance our understanding of ARG distribution.

5.
J Hazard Mater ; 477: 135353, 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-39094306

RESUMEN

Phages are pivotal in shaping microbial communities and biogeochemical cycles, while our understanding of the diversity, functions potential, and resistance gene carriage of phages in hospital wastewater (HWW) remains limited. We collected influent and effluent samples from the 3 hospital wastewater treatment plants (HWTPs) to assess the diversity and fate of phages, the interactions between phages and hosts, and the presence of resistance genes and auxiliary metabolic genes (AMGs) encoded by phages. Compared to influent, effluent showed reduced phage abundance and altered composition, with decreases in Microviridae and Inoviridae. The gene-sharing network highlights that many phages in HWW are not classified in known viral genera, suggesting HWW as a rich source of new viruses. There was a significant association between phages and microorganisms, with approximately 32.57 % of phages expected to be capable of infecting microbial hosts, characterized primarily by lytic activity. A total of 8 unique antibiotic resistance genes, 13 unique metal resistance genes, and 5 mobile genetic elements were detected in 3 HWTPs phageomes. Phage AMGs have the potential to influence carbon, nitrogen, phosphorus, and sulfur metabolism, impacting biogeochemical cycles. This study reveals the genomic diversity and ecological role of phages in HWTPs, highlighting their environmental and ecosystem impact.


Asunto(s)
Bacteriófagos , Hospitales , Aguas Residuales , Aguas Residuales/microbiología , Aguas Residuales/virología , Bacteriófagos/genética , Bacteriófagos/aislamiento & purificación , Genoma Viral , Eliminación de Residuos Líquidos , Variación Genética , Farmacorresistencia Microbiana/genética , Bacterias/genética , Bacterias/virología
6.
Water Sci Technol ; 90(1): 103-123, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39007309

RESUMEN

Drug resistance has become a matter of great concern, with many bacteria now resist multiple antibiotics. This study depicts the occurrence of antibiotic-resistant bacteria (ARB) and resistance patterns in five full-scale hospital wastewater treatment plants (WWTPs). Samples of raw influent wastewater, as well as pre- and post-disinfected effluents, were monitored for targeted ARB and resistance genes in September 2022 and February 2023. Shifts in resistance profiles of Escherichia coli, Pseudomonas aeruginosa, and Acinetobacter baumannii antimicrobial-resistant indicators in the treated effluent compared to that in the raw wastewater were also worked out. Ceftazidime (6.78 × 105 CFU/mL) and cefotaxime (6.14 × 105 CFU/mL) resistant species showed the highest concentrations followed by ciprofloxacin (6.29 × 104 CFU/mL), and gentamicin (4.88 × 104 CFU/mL), in raw influent respectively. WWTP-D employing a combination of biological treatment and coagulation/clarification for wastewater decontamination showed promising results for reducing ARB emissions from wastewater. Relationships between treated effluent quality parameters and ARB loadings showed that high BOD5 and nitrate levels were possibly contributing to the persistence and/or selection of ARBs in WWTPs. Furthermore, antimicrobial susceptibility tests of targeted species revealed dynamic shifts in resistance profiles through treatment processes, highlighting the potential for ARB and ARGs in hospital wastewater to persist or amplify during treatment.


Asunto(s)
Antibacterianos , Hospitales , Aguas Residuales , Aguas Residuales/microbiología , Antibacterianos/farmacología , Eliminación de Residuos Líquidos/métodos , Farmacorresistencia Bacteriana , Bacterias/efectos de los fármacos , Bacterias/genética , Bacterias/clasificación , Pseudomonas aeruginosa/efectos de los fármacos , Pseudomonas aeruginosa/genética , Pruebas de Sensibilidad Microbiana
7.
Sci Total Environ ; 949: 174930, 2024 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-39067608

RESUMEN

Hospital wastewater is a critical source of antimicrobial resistance (AMR), which facilitates the proliferation and spread of clinically significant antimicrobial resistance genes (ARGs) and pathogenic bacteria. This study utilized metagenomic approaches, including advanced binning techniques, such as MetaBAT2, MaxBin2, and CONCOCT, which offer significant improvements in accuracy and completeness over traditional binning methods. These methods were used to comprehensively assess the dynamics and composition of resistomes and mobilomes in untreated wastewater samples taken from two general hospitals and one cancer hospital. This study revealed a diverse bacterial landscape, largely consisting of Proteobacteria, Firmicutes, Bacteroidetes, and Actinobacteria, with notable variations in microbial composition among hospitals. Analysis of the top 15 genera showed unique microbial pattern distribution in each hospital: Aeromonas was predominant in 1stHWTS (49.39 %), Acidovorax in the CAHWTS at 16.85 %, and Escherichia and Bacteroides in the 2ndHWTS at 11.44 % and 11.33 %, respectively. A total of 114 pathogenic bacteria were identified, with drug-resistant Aeromonas caviae and Escherichia coli being the most prevalent. The study identified 34 types and 1660 subtypes of ARGs, including important last-resort antibiotic resistance genes (LARGs), such as blaNDM, mcr, and tet(X). Using metagenomic binning, this study uncovered distinct patterns of host-resistance associations, particularly with Proteobacteria and Firmicutes. Network analysis highlighted the complex interactions among ARGs, mobile genetic elements (MGEs), and bacterial species, all contributing to the dissemination of AMR. These findings emphasize the intricate nature of AMR in hospital wastewater and the influence of hospital-specific factors on microbial resistance patterns. This study provides support for implementing integrated management strategies, including robust surveillance, advanced wastewater treatment, and strict antibiotic stewardship, to control the dissemination of AMR. Understanding the interplay among bacterial communities, ARGs, and MGEs is important for developing effective public health measures against AMR.


Asunto(s)
Hospitales , Metagenómica , Aguas Residuales , Aguas Residuales/microbiología , Farmacorresistencia Microbiana/genética , Genes Bacterianos , Farmacorresistencia Bacteriana/genética , Antibacterianos/farmacología , Bacterias/genética , Bacterias/efectos de los fármacos , Secuencias Repetitivas Esparcidas , Metagenoma
8.
J Hosp Infect ; 151: 79-83, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38950865

RESUMEN

The periphery of the hospital water system interfaces at multiple points with patients and staff in clinical areas. This comprises mostly sinks and showers and presents a significant infection control risk. Wastewater drains in particular act as a reservoir of pathogens that can be transmitted to patients. Numerous strategies have been investigated as potential methods to reduce biofilm and bacterial load including regular application of biocidal chemicals. Traditional methods of assessing the efficacy of such products relies on culture-based microbiological techniques, usually targeting a limited range of key pathogens. We assessed the efficacy of a peracetic acid containing drain disinfectant product on seven clinical handwash basin drains, taking daily samples over six weeks (before, during and after use of the drain disinfectant product). We used a rapid, culture-independent estimation of total bacterial viable count (TVC) to assess efficacy. We applied long-read metagenomic sequencing to study the entire drain microbiome, which allowed taxonomic changes to be documented following use of the drain disinfectant product. All samples were found to be heavily contaminated, however the drain disinfectant product reduced the TVC from an estimated mean of 4228 cfu/mL to 2874 cfu/mL. This reduction was sustained in the two weeks following cessation of the product. Long-read metagenomic sequencing showed a microbiome dominated with Gram-negative organisms, with some taxonomic shifts in samples before and after application of the drain disinfectant. The impact on hospital-acquired infections from reducing bioburden in hospital drains by approximately a third, along with any associated changes in bacterial composition, needs evaluation in future studies.


Asunto(s)
Carga Bacteriana , Desinfectantes , Hospitales , Ácido Peracético , Aguas Residuales , Ácido Peracético/farmacología , Desinfectantes/farmacología , Humanos , Aguas Residuales/microbiología , Bacterias/efectos de los fármacos , Bacterias/clasificación , Bacterias/aislamiento & purificación
9.
Environ Pollut ; 359: 124608, 2024 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-39053807

RESUMEN

Hospital wastewater is known to contain various pathogenic microorganisms and harmful substances. During the hospital wastewater treatment process, the bioaerosols released may encapsulate these pathogens, leading to human infection. This study undertook an investigation to compare the dispersion characteristics and seasonal variations of bioaerosols from hospital and municipal sewage. The results indicated that the airborne bacterial concentration from hospital sewage (119 ± 118 CFU/m3) was higher than municipal sewage (46 ± 19 CFU/m3), with the highest concentration observed in summer. The dominant bacterial genera present in bioaerosols from both sewages were alike, with the proportions varied by sewage types and the structure mainly influenced by seasonal factors. Bacteroides, Escherichia-Shigella and Streptococcus were identified as the most prevalent pathogenic genera in spring, summer and winter bioaerosols, respectively, while Pseudomonas and Acinetobacter were abundant in autumn. Although the non-carcinogenic risk associated with bioaerosols was low (<1), the presence of pathogenic species and their potential synergistic interactions elevated the overall exposure risk. The diffusion modeling results demonstrated that bioaerosol emissions from the surface of hospital sewage can reach up to 10570 CFU/m3 in summer and can spread more than 300 m downwind. The potential pathogenicity of bioaerosols was also highest in summer, which may pose a health hazard to populations located downwind. Therefore, the management and control of bioaerosols from sewage should be strengthened, especially in summer.


Asunto(s)
Aerosoles , Microbiología del Aire , Monitoreo del Ambiente , Hospitales , Estaciones del Año , Eliminación de Residuos Líquidos , Aguas Residuales , Aerosoles/análisis , Aguas Residuales/microbiología , Humanos , Aguas del Alcantarillado/microbiología , Contaminantes Atmosféricos/análisis , Bacterias/aislamiento & purificación , Exposición a Riesgos Ambientales/estadística & datos numéricos
10.
Environ Sci Pollut Res Int ; 31(36): 48813-48838, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39052110

RESUMEN

The increase in the prevalence of carbapenem-resistant Gram-negative bacteria, in particular Acinetobacter baumannii (CRAB) and Pseudomonas aeruginosa (CRPA), poses a serious threat for public health worldwide. This article reviews the alarming data on the prevalence of infections caused by CRAB and CRPA pathogens and their presence in hospital and municipal wastewater, and it highlights the environmental impact of antibiotic resistance. The article describes the key role of antibiotic resistance genes (ARGs) in the acquisition of carbapenem resistance and sheds light on bacterial resistance mechanisms. The main emphasis was placed on the transfer of ARGs not only in the clinical setting, but also in the environment, including water, soil, and food. The aim of this review was to expand our understanding of the global health risks associated with CRAB and CRPA in hospital and municipal wastewater and to analyze the spread of these micropollutants in the environment. A review of the literature published in the last decade will direct research on carbapenem-resistant pathogens, support the implementation of effective preventive measures and interventions, and contribute to the development of improved strategies for managing this problem.


Asunto(s)
Acinetobacter baumannii , Carbapenémicos , Pseudomonas aeruginosa , Aguas Residuales , Aguas Residuales/microbiología , Acinetobacter baumannii/efectos de los fármacos , Carbapenémicos/farmacología , Pseudomonas aeruginosa/efectos de los fármacos , Hospitales , Farmacorresistencia Bacteriana , Antibacterianos/farmacología , Humanos
11.
Infect Drug Resist ; 17: 2439-2448, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38912216

RESUMEN

Background: Hospital wastewater (HWW) promotes the spread of carbapenem resistance genes (CRGs). Aeromonas carry a large number of CRGs in HWW, they may play a role as a suitable reservoir for CRGs, while resistomes in HWW are still poorly characterized regarding carbapenem resistant Aeromonas. Thus, the aim of the study was to evaluate the molecular epidemiological characteristics of carbapenem resistant Aeromonas in HWW. Methods: A total of 33 carbapenem resistant Aeromonas were isolated from HWW. Antimicrobial susceptibility testing and polymerase chain reaction (PCR) were used to assess the antimicrobial resistance profiles. Molecular typing was performed using enterobacterial repetitive intergenic consensus PCR (ERIC-PCR) and multilocus sequence typing (MLST). The horizontal transmission mode of bla KPC was explored through conjugation and transformation experiments. The stability of bla KPC-IncP-6 plasmids was assessed through plasmid stability and in vitro competition test. The PCR mapping method was used to investigate the structural diversity of bla KPC. Results: The detection rates of bla KPC and cphA in Aeromonas were 97.0% and 39.4% respectively. Aeromonas caviae were grouped into 13 clusters by ERIC-PCR and 12 STs by MLST. Aeromonas veronii were grouped into 11 clusters by ERIC-PCR and 4 STs by MLST. 56.3% bla KPC were located on mobilizable IncP-6 plasmids. bla KPC-IncP-6 plasmid showed high stability and low cost fitness. Conclusion: Carbapenem resistant Aeromonas from HWW mainly carried bla KPC, which exhibited great structural diversity. Aeromonas might serve as reservoirs for bla KPC and bla KPC might spread mainly through transformation in HWW.

12.
Environ Geochem Health ; 46(7): 219, 2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38849667

RESUMEN

This study investigates the removal of amoxicillin micropollutants (AM) from hospital wastewater using CoMoO4-modified graphitic carbon nitride (CMO/gCN). Consequently, CMO/gCN exhibits notable improvements in visible light absorption and electron-hole separation rates compared to unmodified gCN. Besides, CMO/gCN significantly enhances the removal efficiency of AM, attaining an impressive 96.5%, far surpassing the performance of gCN at 48.6%. Moreover, CMO/gCN showcases outstanding reusability, with AM degradation performance exceeding 70% even after undergoing six cycles of reuse. The removal mechanism of AM employing CMO/gCN involves various photoreactions of radicals (•OH, •O2-) and amoxicillin molecules under light assistance. Furthermore, CMO/gCN demonstrates a noteworthy photodegradation efficiency of AM from hospital wastewater, reaching 92.8%, with a near-complete reduction in total organic carbon levels. Detailed discussions on the practical applications of the CMO/gCN photocatalyst for removal of micropollutants from hospital wastewater are provided. These findings underline the considerable potential of CMO/gCN for effectively removing various pollutants in environmental remediation strategies.


Asunto(s)
Amoxicilina , Grafito , Oxidación-Reducción , Aguas Residuales , Contaminantes Químicos del Agua , Amoxicilina/química , Aguas Residuales/química , Grafito/química , Contaminantes Químicos del Agua/química , Fotólisis , Hospitales , Compuestos de Nitrógeno/química , Catálisis , Purificación del Agua/métodos
13.
Curr Environ Health Rep ; 11(3): 380-389, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38849638

RESUMEN

PURPOSE OF THE REVIEW: Wastewater is a term used to describe water that has undergone degradation in quality owing to anthropogenic activities or natural processes. Wastewater encompasses liquid waste originating from academic institutions, households, agricultural sector, industries, mines and hospitals. Hospital wastewater contains potentially hazardous substances including residues of pharmaceuticals, radioisotopes, detergents and pathogens, with detrimental impacts to the environment and human health. Nevertheless, studies related to hospital waste management are limited in Africa, particularly in Southern Africa. This research offers an overview of aspects surrounding hospital wastewater in Southern Africa, focusing on Zimbabwe. Already published and grey literature was reviewed to compile the paper. RECENT FINDINGS: Number of patients, nature of medical services offered and hospital size influences generation of hospital wastewater. Partially and non-treated hospital wastewater is managed together with municipal wastewater. Management of hospital wastewater is impeded by shortage of resources, lack of co-ordination among responsible authorities and ineffective legal framework enforcement, among other challenges. Inappropriate hospital wastewater management results in environmental contamination, causing human ailments. Attainment of sustainable hospital wastewater management requires clearly defined and enforced legislation, collaboration of accountable stakeholders, sufficient resources and enhanced awareness of involved stakeholders. Application of technologies that uphold recycling and reuse of wastewater is essential to reach Sustainable Development Goals, Zimbabwe Vision 2030 and National Development Strategy 1 targets, particularly those dealing with environmental protection while upholding human health.


Asunto(s)
Hospitales , Aguas Residuales , Zimbabwe , Aguas Residuales/química , Humanos , Eliminación de Residuos Sanitarios/métodos , Eliminación de Residuos Líquidos/métodos , Administración de Residuos/métodos
14.
J Water Health ; 22(5): 825-834, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38822462

RESUMEN

Hospital wastewater has been identified as a hotspot for the emergence and transmission of multidrug-resistant (MDR) pathogens that present a serious threat to public health. Therefore, we investigated the current status of antibiotic resistance as well as the phenotypic and genotypic basis of biofilm formation in Pseudomonas aeruginosa from hospital wastewater in Dhaka, Bangladesh. The disc diffusion method and the crystal violet assay were performed to characterize antimicrobial resistance and biofilm formation, respectively. Biofilm and integron-associated genes were amplified by the polymerase chain reaction. Isolates exhibited varying degrees of resistance to different antibiotics, in which >80% of isolates showed sensitivity to meropenem, amikacin, and gentamicin. The results indicated that 93.82% of isolates were MDR and 71 out of 76 MDR isolates showed biofilm formation activities. We observed the high prevalence of biofilm-related genes, in which algD+pelF+pslD+ (82.7%) was found to be the prevalent biofilm genotypic pattern. Sixteen isolates (19.75%) possessed class 1 integron (int1) genes. However, statistical analysis revealed no significant association between biofilm formation and multidrug resistance (χ2 = 0.35, P = 0.55). Taken together, hospital wastewater in Dhaka city may act as a reservoir for MDR and biofilm-forming P. aeruginosa, and therefore, the adequate treatment of wastewater is recommended to reduce the occurrence of outbreaks.


Asunto(s)
Antibacterianos , Biopelículas , Farmacorresistencia Bacteriana Múltiple , Hospitales , Pseudomonas aeruginosa , Aguas Residuales , Biopelículas/efectos de los fármacos , Pseudomonas aeruginosa/efectos de los fármacos , Pseudomonas aeruginosa/fisiología , Pseudomonas aeruginosa/aislamiento & purificación , Pseudomonas aeruginosa/genética , Aguas Residuales/microbiología , Bangladesh/epidemiología , Antibacterianos/farmacología , Integrones , Pruebas de Sensibilidad Microbiana
15.
J Hazard Mater ; 474: 134841, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-38852251

RESUMEN

Photochemical transformation is an important attenuation process for the non-steroidal anti-inflammatory drug naproxen (NPX) in both engineered and natural waters. Herein, we investigated the photolysis of NPX in aqueous solution exposed to both ultraviolet (UV, 254 nm) and natural sunlight irradiation. Results show that N2 purging significantly promoted NPX photolysis under UV irradiation, suggesting the formation of excited triplet state (3NPX*) as a critical transient. This inference was supported by benzophenone photosensitization and transient absorption spectra. Sunlight quantum yield of NPX was only one fourteenth of that under UV irradiation, suggesting the wavelength-dependence of NPX photochemistry. 3NPX* formed upon irradiation of NPX underwent photodecarboxylation leading to the formation of 2-(1-hydroxyethyl)-6-methoxynaphthalene (2HE6MN), 2-(1-hydroperoxyethyl)-6-methoxynaphthalene (2HPE6MN), and 2-acetyl-6-methoxynaphthalene (2A6MN). Notably, the conjugation and spin-orbit coupling effects of carbonyl make 2A6MN a potent triplet sensitizer, therefore promoting the photodegradation of the parent NPX. In hospital wastewater, the photolysis of NPX was influenced because the photoproduct 2A6MN and wastewater components could competitively absorb photons. Bioluminescence inhibition assay demonstrated that photoproducts of NPX exhibited higher toxicity than the parent compound. Results of this study provide new insights into the photochemical behaviors of NPX during UV treatment and in sunlit surface waters.


Asunto(s)
Antiinflamatorios no Esteroideos , Naproxeno , Fotólisis , Luz Solar , Rayos Ultravioleta , Contaminantes Químicos del Agua , Naproxeno/química , Naproxeno/efectos de la radiación , Contaminantes Químicos del Agua/química , Contaminantes Químicos del Agua/efectos de la radiación , Contaminantes Químicos del Agua/toxicidad , Antiinflamatorios no Esteroideos/química , Antiinflamatorios no Esteroideos/efectos de la radiación , Benzofenonas/química , Benzofenonas/efectos de la radiación , Fármacos Fotosensibilizantes/química , Fármacos Fotosensibilizantes/efectos de la radiación
16.
Water Res ; 259: 121896, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38865914

RESUMEN

The electro-peroxone (EP) process encounters two inherent challenges in wastewater treatment: sluggish O2/O3 transfer and substantial ozone waste. To overcome these limitations, we introduced micro-nano bubbles (MNBs) aeration to enhance O2/O3 dissolution and diffusion, ultimately aiming to improve the removal of trace pharmaceutical contaminants from hospital wastewater. In the MNBs aeration system, the ozone transfer coefficient ranging from 0.536 to 0.265 min-1, significantly surpassing that of conventional aeration (0.220 to 0.090 min-1) by approximately 2 to 4.5 times. Consequently, the EP process under MNBs aeration significantly enhanced ozone-resistant ibuprofen (IBU) removal, achieving a removal rate of 98.4 ± 1.5 %, far exceeding the 47.3 ± 4.7 % observed with conventional aeration. This significant improvement was attributed to the heightened production of hydroxyl radicals (•OH), reaching 0.97 × 10-9 M s, compared to only 0.28 × 10-9 M s in conventional aeration. The mechanism behind the enhanced •OH production in the MNBs-EP process relied primarily on two factors: improved O2/O3 dissolution due to high internal pressure/large surface and enhanced O3/H2O2 activation from high collapse energy. These factors together contributed to the robust oxidation capability of the MNBs-EP system. As a result, over 97 % removal efficiency was achieved for five representative pharmaceutical pollutants (sulfamethoxazole, ribavirin, norfloxacin, tetracycline and ampicillin) in just 1 min. Furthermore, when applied to real hospital wastewater, the MNBs-O3-E treatment system reduced all 15 detected trace pharmaceutical compounds to below 10 ng L-1 and achieved 14 types of pollutants with removal rates of over 85 % within 15 min, resulting in an ultrahigh total removal rate of 98.6 %, from an initial total concentration of 2108 ng L-1 to less than 30 ng L-1. Thus, micro-nano aeration endowed the EP process as a promising advanced oxidation system for rapid and highly-effective removal of trace pharmaceutical contaminants from hospital wastewater.


Asunto(s)
Hospitales , Ozono , Eliminación de Residuos Líquidos , Aguas Residuales , Contaminantes Químicos del Agua , Ozono/química , Aguas Residuales/química , Eliminación de Residuos Líquidos/métodos , Purificación del Agua/métodos , Preparaciones Farmacéuticas
17.
J Microbiol Methods ; 223: 106953, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38754482

RESUMEN

The microbial composition and stress molecules are main drivers influencing the development and spread of antibiotic resistance bacteria (ARBs) and genes (ARGs) in the environment. A reliable and rapid method for identifying associations between microbiome composition and resistome remains challenging. In the present study, secondary metagenome data of sewage and hospital wastewaters were assessed for differential taxonomic and ARG profiling. Subsequently, Random Forest (RF)-based ML models were used to predict ARG profiles based on taxonomic composition and model validation on hospital wastewaters. Total ARG abundance was significantly higher in hospital wastewaters (15 ppm) than sewage (5 ppm), while the resistance towards methicillin, carbapenem, and fluoroquinolone were predominant. Although, Pseudomonas constituted major fraction, Streptomyces, Enterobacter, and Klebsiella were characteristic of hospital wastewaters. Prediction modeling showed that the relative abundance of pathogenic genera Escherichia, Vibrio, and Pseudomonas contributed most towards variations in total ARG count. Moreover, the model was able to identify host-specific patterns for contributing taxa and related ARGs with >90% accuracy in predicting the ARG subtype abundance. More than >80% accuracy was obtained for hospital wastewaters, demonstrating that the model can be validly extrapolated to different types of wastewater systems. Findings from the study showed that the ML approach could identify ARG profile based on bacterial composition including 16S rDNA amplicon data, and can serve as a viable alternative to metagenomic binning for identification of potential hosts of ARGs. Overall, this study demonstrates the promising application of ML techniques for predicting the spread of ARGs and provides guidance for early warning of ARBs emergence.


Asunto(s)
Bacterias , Microbiota , Aguas del Alcantarillado , Aguas Residuales , Aguas Residuales/microbiología , Microbiota/efectos de los fármacos , Microbiota/genética , Bacterias/genética , Bacterias/efectos de los fármacos , Bacterias/clasificación , Bacterias/aislamiento & purificación , Aguas del Alcantarillado/microbiología , Antibacterianos/farmacología , ARN Ribosómico 16S/genética , Metagenoma , Farmacorresistencia Bacteriana/genética , Hospitales , Metagenómica/métodos , Genes Bacterianos/genética , Farmacorresistencia Microbiana/genética , Pseudomonas/genética , Pseudomonas/efectos de los fármacos , Pseudomonas/aislamiento & purificación , Pseudomonas/clasificación
18.
Chemosphere ; 356: 141973, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38608777

RESUMEN

Pharmaceuticals are progressively employed in both human and veterinary medicine and increasingly recognized as environmental contaminants. This study investigated the occurrence of selected pharmaceuticals in influent and effluent of wastewater treatment plants of 12 hospitals in Hanoi and 3 northern cities of Vietnam during dry and rainy seasons. In addition, environmental risk of pharmaceuticals in both hospital influents and effluents were evaluated based on risk quotients (RQs). Nine selected pharmaceutical compounds including sulfamethoxazole (SMX), naproxen (NPX), diclofenac (DCF), ibuprofen (IBU), acetaminophen (ACT), carbamazepine (CBM), iopromide (IOP), atenolol (ATN), and caffeine (CAF) were frequently detected in most influent and effluent wastewaters of 12 investigated hospitals. Detected compound levels exhibited a wide range, from as low as 1 ng/L for DCF to as high as 61,772 ng/L for ACT. Among these compounds, ACT, CAF, SMX, and IOP were consistently detected at substantial concentrations in both influents and effluents. This investigation also highlighted potential risks posed by SMX, ACT, and CAF residues present in influents and effluents of hospital wastewater treatment plants (WWTPs) to aquatic ecosystem. These finding are expected to provide scientific-based evidence for the development of hospital waste management and environmental management programs in Vietnam.


Asunto(s)
Monitoreo del Ambiente , Hospitales , Aguas Residuales , Contaminantes Químicos del Agua , Aguas Residuales/química , Vietnam , Contaminantes Químicos del Agua/análisis , Preparaciones Farmacéuticas/análisis , Medición de Riesgo , Eliminación de Residuos Líquidos , Humanos
19.
Antibiotics (Basel) ; 13(4)2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38667011

RESUMEN

Antimicrobial resistance (AMR) has emerged and spread globally. Recent studies have also reported the presence of antimicrobials in a wide variety of aquatic environments. Conducting a nationwide monitoring survey of AMR in the environment to elucidate its status and to assess its impact on ecosystems and human health is of social importance. In this study, we developed a novel high-throughput analysis (HTA) system based on a 96-well plate solid-phase extraction (SPE), using automated pipetting and an SPE pre-treatment system. The effectiveness of the system as an HTA for antimicrobials in environmental water was verified by comparing it with a conventional manual analytical system in a domestic hospital over a period of two years and four months. The results of the manual analysis and HTA using a combination of automated pipetting and SPE systems were generally consistent, and no statistically significant difference was observed (p > 0.05) between the two systems. The agreement ratios between the measured concentrations based on the conventional and HTA methods were positively correlated with a correlation coefficient of r = 0.99. These results indicate that HTA, which combines automated pipetting and an SPE pre-treatment system for rapid, high-volume analysis, can be used as an effective approach for understanding the environmental contamination of antimicrobials at multiple sites. To the best of our knowledge, this is the first report to present the accuracy and agreement between concentrations based on a manual analysis and those measured using HTA in hospital wastewater. These findings contribute to a comprehensive understanding of antimicrobials in aquatic environments and assess the ecological and human health risks associated with antimicrobials and antimicrobial-resistant bacteria to maintain the safety of aquatic environments.

20.
J Hazard Mater ; 471: 134340, 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38640670

RESUMEN

While the effectiveness of Poly-Aluminum Chloride (PAC) coagulation for pollutant removal has been documented across various wastewater scenarios, its specific application in hospital wastewater (HWW) treatment to remove conventional pollutants and hazardous genetic pollutants has not been studied. The research compared three hospital wastewater treatment plants (HWTPs) to address a knowledge gap, including the PAC coagulation-sodium hypochlorite disinfection process (PAC-HWTP), the biological contact oxidation-precipitation-sodium hypochlorite process (BCO-HWTP), and a system using outdated equipment with PAC coagulation (ODE-PAC-HWTP). Effluent compliance with national discharge standards is assessed, with BCO-HWTP meeting standards for direct or indirect discharge into natural aquatic environments. ODE-PAC-HWTP exceeds pretreatment standards for COD and BOD5 concentrations. PAC-HWTP effluent largely adheres to national pretreatment standards, enabling release into municipal sewers for further treatment. Metagenomic analysis reveals that PAC-HWTP exhibits higher removal efficiencies for antibiotic resistance genes, metal resistance genes, mobile genetic elements, and pathogens compared to BCO-HWTP and ODE-PAC-HWTP, achieving average removal rates of 45.13%, 57.54%, 80.61%, and 72.17%, respectively. These results suggests that when discharging treated HWW into municipal sewers for further processing, the use of PAC coagulation process is more feasible and cost-effective compared to BCO technologies. The analysis emphasizes the urgent need to upgrade outdated equipment HWTPs.


Asunto(s)
Hospitales , Oxidación-Reducción , Hipoclorito de Sodio , Aguas Residuales , Contaminantes Químicos del Agua , Aguas Residuales/química , Hipoclorito de Sodio/química , Contaminantes Químicos del Agua/química , Eliminación de Residuos Líquidos/métodos , Desinfección/métodos , Purificación del Agua/métodos , Polímeros/química , Hidróxido de Aluminio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...