Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.949
Filtrar
1.
Acta Med Philipp ; 58(2): 63-68, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38966155

RESUMEN

Background: Surgical correction of aphakia without capsular support continues to be a challenge. Improvements in the technology of cataract surgery have provided advancements in techniques in surgical management of aphakia. Locally, we have limited data on the outcomes of the different intraocular lenses used in aphakia. Objective: This study aimed to determine visual outcomes and complications associated with different techniques of intraocular lens implantation in the absence of capsular support. Methods: We reviewed the medical charts of 207 patients who underwent intraocular lens implantation without capsular support. Excluded were patients with incomplete follow up, pediatric patients, and lost records. Best corrected visual acuity at day 1, 1st month, 3rd month and 6th month postoperatively, and the complications were noted. Results: Mean age was 60 and 51% (n=105) were females. The mean follow-up time was 9.33 ± 0.71 months. Loss of capsular support was most frequently caused by intraoperative complication (n=146, 70%) and trauma. Retropupillary fixation iris claw intraocular lens was frequently used (n=93, 44.9%). Across all patients, visual acuities showed excellent outcomes with 20/50 or better. Across IOL types, the most frequent postoperative complication was increase in IOP. Statistically significant results were set at P <0.05. Conclusion: There is a notable preference towards iris claw retropupillary lenses through time. Iris claw lenses showed the shortest operative time. All intraocular lenses used in aphakia showed comparably good postoperative visual acuities, except for the superior visual acuity trend seen among retropupillary iris claw and anterior chamber IOL groups. Complications included elevated intraocular pressures, corneal edema, and pigment dispersion.

2.
Comput Biol Med ; 179: 108864, 2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38991320

RESUMEN

Fractional-order (FO) chaotic systems exhibit random sequences of significantly greater complexity when compared to integer-order systems. This feature makes FO chaotic systems more secure against various attacks in image cryptosystems. In this study, the dynamical characteristics of the FO Sprott K chaotic system are thoroughly investigated by phase planes, bifurcation diagrams, and Lyapunov exponential spectrums to be utilized in biometric iris image encryption. It is proven with the numerical studies the Sprott K system demonstrates chaotic behaviour when the order of the system is selected as 0.9. Afterward, the introduced FO Sprott K chaotic system-based biometric iris image encryption design is carried out in the study. According to the results of the statistical and attack analyses of the encryption design, the secure transmission of biometric iris images is successful using the proposed encryption design. Thus, the FO Sprott K chaotic system can be employed effectively in chaos-based encryption applications.

3.
medRxiv ; 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-39006424

RESUMEN

Diagnostic approaches that combine the high sensitivity and specificity of laboratory-based digital detection with the ease of use and affordability of point-of-care (POC) technologies could revolutionize disease diagnostics. This is especially true in infectious disease diagnostics, where rapid and accurate pathogen detection is critical to curbing the spread of disease. We have pioneered an innovative label-free digital detection platform that utilizes Interferometric Reflectance Imaging Sensor (IRIS) technology. IRIS leverages light interference from an optically transparent thin film, eliminating the need for complex optical resonances to enhance the signal by harnessing light interference and the power of signal averaging in shot-noise-limited operation to achieve virtually unlimited sensitivity. In our latest work, we have further improved our previous 'Single-Particle' IRIS (SP-IRIS) technology by allowing the construction of the optical signature of target nanoparticles (whole virus) from a single image. This new platform, 'Pixel-Diversity' IRIS (PD-IRIS), eliminated the need for z-scan acquisition, required in SP-IRIS, a time-consuming and expensive process, and made our technology more applicable to POC settings. Using PD-IRIS, we quantitatively detected the Monkeypox virus (MPXV), the etiological agent for Monkeypox (Mpox) infection. MPXV was captured by anti-A29 monoclonal antibody (mAb 69-126-3) on Protein G spots on the sensor chips and were detected at a limit-of-detection (LOD) - of 200 PFU/ml (~3.3 attomolar). PD-IRIS was superior to the laboratory-based ELISA (LOD - 1800 PFU/mL) used as a comparator. The specificity of PD-IRIS in MPXV detection was demonstrated using Herpes simplex virus, type 1 (HSV-1), and Cowpox virus (CPXV). This work establishes the effectiveness of PD-IRIS and opens possibilities for its advancement in clinical diagnostics of Mpox at POC. Moreover, PD-IRIS is a modular technology that can be adapted for the multiplex detection of pathogens for which high-affinity ligands are available that can bind their surface antigens to capture them on the sensor surface.

4.
Ophthalmology ; 2024 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-39033858

RESUMEN

IRIS (Intelligent Research in Sight) Registry Study showing that acute retinal necrosis cases treated with systemic antivirals alone vs combined with intravitreal antivirals or early vitrectomy had statistically similar outcomes at 6 and 12 months.

5.
Case Rep Ophthalmol ; 15(1): 552-558, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39015242

RESUMEN

Introduction: Iris retraction syndrome (IRS) is a rare clinical condition characterized by a backbowing of the iris positioned on the lens with a complete pupillary block. Immune checkpoint inhibitors (ICIs) are a new class of immunomodulating agents used in cancer therapy, and although they have high response rates, ophthalmic-related side effects have been reported. We report a rare case of bilateral IRS with hypotony after therapy with nivolumab. Case Presentation: We present a case of bilateral IRS with hypotony, 3 mm Hg OD and 5 mm Hg OS, after therapy with nivolumab. The patient presented with decreased vision, corneal edema, keratic precipitates, deep anterior chamber with posterior synechiae, and hypotony maculopathy. Anterior segment OCT revealed a sharp posterior displacement of the iridolenticular diaphragm consistent with IRS. Discontinuation of nivolumab until ocular improvement was suggested, following oncologic consultation. Four months later, the patient exhibited iris bombé with angle closure and increased IOP. This was managed with phacoemulsification and concomitant surgical iridectomy. One month after surgery, the patient's IOP had returned to physiologic values, and the iris configuration had returned to normal. Conclusion: The exact mechanism of IRS remains unclear, but it is suggested that an aqueous imbalance, in conjunction with uveitis and hypotony, creates an anterio-posterior movement of the iridolenticular diaphragm when the pupillary block is present. Our case highlights the importance of monitoring patients receiving ICIs for ophthalmic adverse effects and prompt management to prevent permanent visual damage. In conclusion, this is the first reported case of IRS after therapy with ICIs. Further research is needed to fully understand the exact mechanism by which it is induced.

6.
Diagn Microbiol Infect Dis ; 110(1): 116439, 2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-39024934

RESUMEN

We evaluated the DxU 850m Iris Urine Microscopy analyzer as a screening tool for excluding negative urine samples (n = 1337). At a cutoff of 103 colony counts·mL-1, sensitivity was 55.1 %, specificity 68.6 %. The DxU 850m Iris does not offer acceptable prediction of culture-negative urine samples at the tested cutoff.

7.
Ophthalmol Glaucoma ; 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39032697

RESUMEN

PURPOSE: To examine racial and ethnic differences in the prevalence and treatment patterns for neovascular glaucoma (NVG) in at-risk individuals in the American Academy of Ophthalmology (Academy) IRIS® Registry (Intelligent Research in Sight). PARTICIPANTS: Eyes in the IRIS Registry with a retinal ischemia based on a history of proliferative diabetic retinopathy (PDR), retinal vein occlusion (RVO), and/or ocular ischemic syndrome (OIS). METHODS: Race and ethnicity was defined as Asian, Black, Hispanic/Latino, Non-Hispanic White, and Other/Unknown. In eyes with retinal ischemia, the outcome was neovascular glaucoma (NVG). In eyes with NVG, outcomes included treatment of retinal ischemia with pan-retinal photocoagulation (PRP), and surgery to lower intraocular pressure (IOP) with trabeculectomy, tube shunt, and cyclophotocoagulation (CPC). Covariates included age, sex, region of residence, insurance type, smoking status, and systemic and ocular comorbidities. Cox proportional hazards regression was used to examine adjusted associations between race and ethnicity and NVG and each type of NVG treatment. MAIN OUTCOME MEASURES: Incidence of NVG, PRP, trabeculectomy, tube shunt, CPC, and any IOP-lowering surgery RESULTS: Of 312,106 eyes with retinal ischemia, there were 5,885 (1.9%) with NVG. Compared to eyes of individuals who identified as Non-Hispanic White, eyes of individuals who were Black and Hispanic/Latino had higher hazards of NVG in adjusted analyses (hazards ratio [HR]=1.28, 95% confidence interval [CI]=1.15, 1.43 for Black; HR=1.32, 95% CI=1.17, 1.47 for Hispanic/Latino). Compared to eyes of individuals who were Non-Hispanic White, there was higher hazards of trabeculectomy in eyes of individuals who were Hispanic/Latino (adjusted HR=1.91, 95% CI=1.08, 3.39) and higher hazards of tube shunt (adjusted HR=1.35, 95% CI=1.07, 1.69) and of any IOP-lowering surgery (adjusted HR=1.29, 95% CI=1.09, 1.53) in eyes of individuals who were Black. There were no statistically significant differences in the hazards of PRP or CPC. CONCLUSIONS: Eyes of Black and Hispanic/Latino individuals with retinal ischemia in the IRIS Registry had higher likelihood of NVG and of IOP-lowering surgery for NVG. Further study is needed to examine the medical and social factors that preclude optimal management of diabetic eye disease, in order to prevent its blinding complications.

8.
Ophthalmol Sci ; 4(5): 100524, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38881608

RESUMEN

Purpose: We used exact matching and inverse propensity score weighting (IPSW) using real-world data (RWD) from the American Academy of Ophthalmology IRIS® Registry (Intelligent Research in Sight) to emulate the 2 pro re nata (prn) treatment arms from the Comparison of AMD Treatment Trial (CATT) and to compare the outcomes of the RWD arms to the 2 monthly treatment arms from the clinical trial. Design: Retrospective cohort study utilizing deidentified electronic health record registry data and patient-level deidentified clinical trial data. Subjects: All treatment-naive patient eyes with neovascular age-related macular degeneration treated with ranibizumab or bevacizumab only for 1 year from either the CATT or the IRIS Registry. Methods: Patients were identified in the IRIS Registry between October 1, 2015 and December 31, 2019. After all nonimaging-based inclusion and exclusion criteria from the CATT were applied, patient eyes receiving bevacizumab or ranibizumab only on a prn basis were identified as the eligible cohort. Exact matching and ISPW was applied based on age, gender, and baseline visual acuity. Main Outcome Measures: Mean change in visual acuity, in approximated ETDRS letters, between baseline and 1 year for the IRIS Registry prn treatment arms generated by exact matching and IPSW. Results: We identified 427 eyes treated with ranibizumab prn and 771 eyes treated with bevacizumab prn. Using exact matching, 98% (n = 281) of CATT patient eyes in the bevacizumab monthly treatment arm and 87% (n = 261) of CATT patient eyes in the ranibizumab monthly treatment arm were matched to a patient eye in the IRIS Registry. For the ranibizumab prn treatment arm, patient eyes generated using exact matching gained 1.9 letters and those generated using IPSW gained 2.8 letters (exact matching: 1.9 letters ± 14.0 vs. IPSW: 2.8 letters ± 15.0 letters, P = 0.43). For the bevacizumab prn treatment arm, patient eyes generated using exact matching gained 2.4 letters and those generated using IPSW gained 2.1 letters (exact matching: 2.4 letters ± 15.4 vs. IPSW: 2.1 letters ± 16.0 letters, P = 0.79). Conclusions: Both exact matching and IPSW produced similar results in emulating the prn treatment arms of the CATT using IRIS Registry data and patient-level clinical trial data. Similar to prior real-world studies, the clinical outcomes were significantly worse in the IRIS Registry treatment arms compared with the clinical trial. Financial Disclosures: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

9.
BMC Gastroenterol ; 24(1): 203, 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38886646

RESUMEN

Transanal total mesorectal excision (taTME) has improved the laparoscopic dissection for rectal cancer in the narrow pelvis. Although taTME has more clinical benefits than laparoscopic surgery, such as a better view of the distal rectum and direct determination of distal resection margin, an intraoperative urethral injury could occur in excision ta-TME. This study aimed to determine the feasibility and efficacy of the ta-TME with IRIS U kit surgery. This retrospective study enrolled 10 rectal cancer patients who underwent a taTME with an IRIS U kit. The study endpoints were the safety of access (intra- or postoperative morbidity). The detectability of the IRIS U kit catheter was investigated by using a laparoscope-ICG fluorescence camera system. Their mean age was 71.4±6.4 (58-78) years; 80 were men, and 2 were women. The mean operative time was 534.6 ± 94.5 min. The coloanal anastomosis was performed in 80%, and 20% underwent abdominal peritoneal resection. Two patients encountered postoperative complications graded as Clavien-Dindo grade 2. The transanal approach with IRIS U kit assistance is feasible, safe for patients with lower rectal cancer, and may prevent intraoperative urethral injury.


Asunto(s)
Estudios de Factibilidad , Complicaciones Posoperatorias , Neoplasias del Recto , Cirugía Endoscópica Transanal , Uretra , Humanos , Neoplasias del Recto/cirugía , Masculino , Femenino , Anciano , Persona de Mediana Edad , Estudios Retrospectivos , Uretra/lesiones , Uretra/cirugía , Cirugía Endoscópica Transanal/métodos , Cirugía Endoscópica Transanal/efectos adversos , Complicaciones Posoperatorias/prevención & control , Complicaciones Posoperatorias/etiología , Tempo Operativo , Proctectomía/métodos , Proctectomía/efectos adversos , Complicaciones Intraoperatorias/prevención & control , Complicaciones Intraoperatorias/etiología , Recto/cirugía , Anastomosis Quirúrgica/efectos adversos , Anastomosis Quirúrgica/métodos , Laparoscopía/métodos , Laparoscopía/efectos adversos
10.
Cureus ; 16(5): e60608, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38894792

RESUMEN

In this case report, we describe a rare case of acute angle closure in an 18-year-old African-American female, attributed to plateau iris. The patient had no significant medical or ocular history and presented with high right-eye pressure, headache, and blurred vision. Ocular examination revealed findings consistent with acute angle closure, with gonioscopy confirming superior iris insertion anterior to Schwalbe's line and a "double hump" sign. Ultrasound biomicroscopy confirmed plateau iris. Treatment involved pharmacological management and bilateral peripheral laser iridoplasty. This case underscores the importance of considering plateau iris syndrome in the differential diagnosis of acute angle closure, even in younger patients, and highlights the role of early diagnosis and appropriate intervention in preventing vision loss.

11.
Medicina (Kaunas) ; 60(6)2024 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-38929482

RESUMEN

Different techniques for artificial iris implantation with or without an intraocular lens, depending on lens status, are described in the literature. We describe a surgical technique for a custom-made artificial iris and toric-intraocular lens intrascleral flange fixation. We modified the "Backpack" artificial iris implantation surgical technique to facilitate an accurate alignment of the toric-intraocular lens in a patient with aphakia, aniridia, and high asymmetric astigmatism secondary to blunt trauma. Two months after the surgery, uncorrected visual acuity was 20/30, corrected to 20/25 with a refraction of -2.00 in the diopter sphere with no residual astigmatism. The artificial iris implant and toric-intraocular lens were well-centered. The patient was satisfied with the visual and cosmetic outcomes. This procedure, however, is not complication-free as our patient developed uveitis and increased intraocular pressure during the postoperative period, which was treated successfully.


Asunto(s)
Iris , Lentes Intraoculares , Humanos , Iris/cirugía , Iris/lesiones , Esclerótica/cirugía , Implantación de Lentes Intraoculares/métodos , Agudeza Visual , Astigmatismo/cirugía , Astigmatismo/etiología , Masculino , Aniridia/cirugía , Femenino
12.
Int Ophthalmol ; 44(1): 269, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38914871

RESUMEN

PURPOSE: Evaluation of anterior segment parameters using the Scheimpflug corneal topography 1 year after surgery in patients who underwent sutureless scleral fixation intraocular lens (SFIOL) implantation using the modified Yamane technique and retropupillary iris-claw intraocular lens (RPIOL) implantation. METHODS: A total of 60 eyes from 57 patients who underwent sutureless SFIOL implantation and 57 eyes from 52 patients who underwent RPIOL implantation were included. Anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV), anterior-posterior corneal astigmatism, and keratometric values were assessed using the Scheimpflug corneal topography (Pentacam HR, Germany). RESULTS: There was no statistically significant difference in postoperative UCVA and BCVA between the sutureless SFIOL and the RPIOL group (p = 0.236, p = 0.293, respectively). While there was no statistically significant difference in postoperative IOP between the two groups (p = 0.223), a statistically significant decrease in IOP was observed in both groups (p < 0.001). While there was no statistical difference between the sutureless SFIOL group and the RPIOL group in terms of spherical value (p = 0.441) and spherical equivalence (p = 0.237), there was a statistically significant difference in cylindrical value (p < 0.001). While there was a statistical difference in anterior astigmatism (p < 0.001), there was no statistical difference in posterior astigmatism (p = 0.405). There was no statistical difference in terms of ACV, ACD, and ACA between the sutureless SFIOL and the RPIOL group (p = 0.812, p = 0.770, p = 0.401, respectively). CONCLUSION: In this study, although there was a statistical difference in cylindrical value and anterior corneal astigmatism between the sutureless SFIOL and RPIOL groups, vision was not affected. According to this study, sutureless SFIOL and RPIOL are two successful methods in terms of visual acuity, anterior segment, and keratometry outcomes in aphakic patients after phacoemulsification.


Asunto(s)
Topografía de la Córnea , Iris , Implantación de Lentes Intraoculares , Esclerótica , Procedimientos Quirúrgicos sin Sutura , Agudeza Visual , Humanos , Masculino , Femenino , Esclerótica/cirugía , Implantación de Lentes Intraoculares/métodos , Persona de Mediana Edad , Anciano , Iris/cirugía , Procedimientos Quirúrgicos sin Sutura/métodos , Lentes Intraoculares , Estudios Retrospectivos , Segmento Anterior del Ojo/diagnóstico por imagen , Segmento Anterior del Ojo/cirugía , Adulto , Resultado del Tratamiento , Diseño de Prótesis , Afaquia Poscatarata/cirugía , Afaquia Poscatarata/fisiopatología , Estudios de Seguimiento , Afaquia/cirugía , Afaquia/fisiopatología , Afaquia/diagnóstico
13.
J Environ Manage ; 364: 121428, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38879966

RESUMEN

The use of wetland plants in the context of phytoremediation is effective in the removal of antibiotics from contaminated water. However, the effectiveness and efficiency of many of these plants in the removal of antibiotics remain undetermined. In this study, the effectiveness of two plants-Phragmites australis and Iris pseudacorus-in the removal of tetracycline (TC) in hydroponic systems was investigated. The uptake of TC at the roots of I. pseudacorus and P. australis occurred at concentrations of 588.78 and 106.70 µg/g, respectively, after 7-day exposure. The higher uptake of TC in the root of I. pseudacorus may be attributed to its higher secretion of root exudates, which facilitate conditions conducive to the reproduction of microorganisms. These rhizosphere-linked microorganisms then drove the TC uptake, which was higher than that in the roots of P. australis. By elucidating the mechanisms underlying these uptake-linked outcomes, we found that the uptake of TC for both plants was significantly suppressed by metabolic and aquaporin inhibition, suggesting uptake and transport of TC were active (energy-dependent) and passive (aquaporin-dominated) processes, respectively. The subcellular distribution patterns of I. pseudacorus and P. australis in the roots were different, as expressed by differences in organelles, cell wall concentration levels, and transport-related dynamics. Additionally, the microbe-driven enhancement of the remediation capacities of the plants was studied comprehensively via a combined microbial-phytoremediation hydroponic system. We confirmed that the microbial agents increased the secretion of root exudates, promoting the variation of TC chemical speciation and thus enhancing the active transport of TC. These results contribute toward the improved application of wetland plants in the context of antibiotic phytoremediation.


Asunto(s)
Biodegradación Ambiental , Raíces de Plantas , Tetraciclina , Humedales , Tetraciclina/metabolismo , Raíces de Plantas/metabolismo , Contaminantes Químicos del Agua/metabolismo , Rizosfera , Hidroponía
14.
Comput Biol Med ; 177: 108631, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38824787

RESUMEN

The incident light reflected from the cornea is rich in information about the human surroundings, and these reflected rays are imaged by the camera, which can be used for research on human consciousness and gaze analysis, and produce certain help in the fields of psychology, human computer interaction and disease diagnosis. However, limited by the low corneal reflection ability, when a high-definition camera captures corneal reflecting rays, a large amount of color and texture interference from the iris can seriously contaminate the corneal reflection images, resulting in low usability and ubiquity of corneal reflection images. In this paper, we propose a corneal reflection image extraction method with multiple eye images as input. We align the iris regions of multiple eye images with the help of iris localization method, and by comparing multiple iris regions, we obtain the complementary iris regions, so that the iris interference in the corneal reflection region can be stripped completely. A large number of experiments have demonstrated that our work can effectively mitigate iris interference and effectively improve the quality of corneal reflection images.


Asunto(s)
Córnea , Procesamiento de Imagen Asistido por Computador , Humanos , Córnea/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Iris/diagnóstico por imagen , Algoritmos
15.
Front Plant Sci ; 15: 1305240, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38863554

RESUMEN

The native populations of Iris hymenospatha and Iris histrio, two endangered bulbous species within the large Iris genus in Iridaceae, are threatened with extinction due to mining and other industrial activities in their natural habitats in Central Asia, including Iran. These species not only have a significant economic impact on the global horticultural industry due to their versatility and attractive phenotypic traits, but also have significant ecological value that necessitates their conservation. In this study, we examined the morphological and functional diversity between individuals within these two species, which exhibit high tolerance to environmental stresses. Our study examined 10 populations of I. hymenospatha and two populations of I. histrio based on bulb, flower, and leaf characteristics throughout Iran. We recognized a gradation of five different leaf shapes among I. hymenospatha populations with significant differences between some populations, including "Arak-Khomain" and "Arak-Gerdo". The "Jaro", "Natanz-Karkas", "Ardestan-Taleghan", "Arak-Rahjerd", "Arak-Gerdo", "Ganjnameh", and "Abas-Abad" populations of I. hymenospatha displayed maximal values in leaf width, stem diameter under flower, crown diameter, flower number, leaf number, and bulb diameter. The I. histrio "Velian" population had a significantly larger flower size, a longer stem length, a larger style width, a longer flowering date, and a higher plant height compared to the "Ganjnameh" population of I. histrio. Such characteristics of both species make them remarkable ornamental plants. Our study also revealed that I. hymenospatha populations grow on different soils and elevations and have the ability to adapt to different growing conditions. Given the threats they face, conservation through horticultural selection and propagation offers a viable conservation strategy for both species. This approach not only preserves the genetic diversity of these species, but also enables their further contribution to the horticultural industry.

16.
Zhongguo Dang Dai Er Ke Za Zhi ; 26(6): 639-645, 2024 Jun 15.
Artículo en Chino | MEDLINE | ID: mdl-38926382

RESUMEN

OBJECTIVES: To explore the effects of iris xanthin on airway inflammation, airway remodeling, and the high mobility group box 1 protein (HMGB1)/Toll-like receptor 4 (TLR4)/nuclear factor-κB (NF-κB) pathway in asthmatic young mice. METHODS: Sixty male BALB/c young mice were randomly assigned into six groups: a blank group, a model group, a dexamethasone group, and low, medium, and high dose groups of iris xanthin, with ten mice per group. Asthma models were induced through intraperitoneal injections of a sensitizing agent [ovalbumin (OVA) 20 µg + aluminum hydroxide gel 2 mg], followed by 4% OVA aerosol inhalation. Lung function was measured using a pulmonary function tester to determine lung volume (LV), resting ventilation per minute (VE), and airway reactivity (Penh value). Hematoxylin-eosin (HE) staining was employed to examine and analyze airway remodeling. The contents of interleukin (IL)-1ß, IL-6, and tumor necrosis factor alpha (TNF-α) in bronchoalveolar lavage fluid were quantified using ELISA. Real-time fluorescence quantitative polymerase chain reaction and Western blot analysis were used to assess the expression of HMGB1/TLR4/NF-κB pathway-related mRNA and proteins in lung tissues. RESULTS: Compared to the model group, the dexamethasone and iris xanthin-treated groups (low, medium, and high doses) exhibited significant increases in LV and VE (P<0.05), with incremental dose-dependent increases observed in the iris xanthin groups. Additionally, Penh values, IL-1ß, IL-6, TNF-α, and airway remodeling indicators, along with mRNA levels of HMGB1, TLR4, and NF-κB p65 and protein levels of HMGB1, TLR4, and p-NF-κB p65, were all reduced (P<0.05) in a dose-dependent manner. When compared to the dexamethasone group, the low and medium dose iris xanthin groups showed decreases in LV and VE (P<0.05), whereas Penh values, IL-1ß, IL-6, TNF-α, and airway remodeling indicators, along with mRNA levels of HMGB1, TLR4, NF-κB p65 and protein levels of HMGB1, TLR4, and p-NF-κB p65, were increased (P<0.05). No significant differences were noted in these indices between the high dose iris xanthin group and the dexamethasone group (P>0.05). CONCLUSIONS: Iris xanthin can effectively alleviates airway inflammation and inhibits airway remodeling in asthmatic young mice, possibly through the suppression of the HMGB1/TLR4/NF-κB pathway.


Asunto(s)
Remodelación de las Vías Aéreas (Respiratorias) , Asma , Proteína HMGB1 , Ratones Endogámicos BALB C , FN-kappa B , Transducción de Señal , Receptor Toll-Like 4 , Animales , Remodelación de las Vías Aéreas (Respiratorias)/efectos de los fármacos , Asma/tratamiento farmacológico , Asma/metabolismo , Masculino , Ratones , Receptor Toll-Like 4/genética , Receptor Toll-Like 4/metabolismo , Proteína HMGB1/genética , Proteína HMGB1/metabolismo , FN-kappa B/metabolismo , Transducción de Señal/efectos de los fármacos
17.
Vet Sci ; 11(6)2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38922008

RESUMEN

This study investigated the utility of optical coherence tomography (OCT) for staging iris pigmented lesions in cats. Eighteen cats that underwent OCT examination for unilateral iris pigmented lesion were included. The cats were either suspected of melanosis due to clinical features (n = 8) or had been definitively diagnosed through histopathology with iris melanosis (n = 3), early feline diffuse iris melanoma (FDIM) (n = 4), or mid-stage or advanced FDIM (n = 3). From OCT images, mean iris thickness (MIT) was measured, and the ratio of pigmented lesion to normal iris (PN) was calculated. OCT images depicted the entire iris layer in all eyes with suspected melanosis, iris melanosis, and early FDIM, but observing the entire lesion in mid-stage/advanced FDIM was challenging. No significant difference in MIT was observed among the groups. Conversely, PN ratio was significantly higher (p < 0.05) in early FDIM (1.29 ± 0.16) than in suspected melanosis (1.02 ± 0.10) or iris melanosis (0.99 ± 0.09). Furthermore, OCT imaging revealed hyperreflective lines in 75% of eyes with suspected melanosis and in all the eyes with iris melanosis, corresponding to the pigmented lesions. Our results demonstrate that OCT is capable of detecting subtle differences in iris thickness and features in early-stage FDIM, indicating its potential utility in distinguishing between iris melanosis and early FDIM. Further study is warranted to verify the reliability of such OCT findings.

18.
Ophthalmol Sci ; 4(5): 100513, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38840779

RESUMEN

Purpose: To describe a pilot study on the use of single-session, high-dose-rate, Food and Drug Administration-cleared, yttrium-90 (Y90) plaque brachytherapy for iris and iridociliary melanoma. Design: A single-center, clinical case series. Participants: Six consecutive patients were included in this study. Each was diagnosed with an iris or iridociliary melanoma based on clinical examination with or without biopsy. Methods: Each tumor was staged according to the American Joint Committee on Cancer criteria and received Y90 eye plaque brachytherapy. The main variables were tumor size, patient age, sex, and method of diagnosis (clinical or biopsy). Surgical techniques, treatment durations, and ocular side effects were recorded. Local control was defined as a lack of tumor growth or regression determined by clinical examinations, including slit-lamp and gonio photography, as well as high-frequency ultrasound measurements. Toxicity parameters included acute and short-term corneal/scleral change, anterior segment inflammation, and cataract progression. Main Outcome Measures: Local and systemic cancer control, tumor regression, visual acuity, as well as radiation-related normal tissue toxicity. Results: High-dose-rate Y90 plaque brachytherapy was used to treat small (American Joint Committee on Cancer cT1) category melanomas. Single-surgery high-dose-rate irradiations were performed under anesthesia. Because of short treatment durations, high-dose-rate Y90 did not require the additional procedures used for low-dose-rate plaque (e.g., sutures, amniotic membrane epicorneal buffering, Gunderson flaps, and second surgeries for plaque removal). Only conjunctival recession was used to avoid normal tissue irradiation. High-dose-rate Y90 treatment durations averaged 8.8 minutes (median, 7.9; range, 5.8-12.9). High-dose-rate Y90 brachytherapy was associated with no periorbital, corneal (Descemet folds), or conjunctival edema. There was no acute or short-term anterior uveitis, secondary cataract, scleropathy, radiation retinopathy, maculopathy, or optic neuropathy. The follow-up was a mean of 16.0 (range 12-24) months. Evidence of local control included a lack of expansion of tumor borders (n = 6, 100%), darkening with or without atrophy of the tumor surface (n = 5/6, 83%), and a mean 24.5% reduction in ultrasonographically measured tumor thickness. There were no cases of metastatic disease. Conclusions: High-dose-rate Y90 brachytherapy allowed for single-surgery, minimally invasive, outpatient irradiation of iris and iridociliary melanomas. Financial Disclosures: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

19.
Heliyon ; 10(11): e31795, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38832280

RESUMEN

Exploring the chemical processes and factors influencing the stability of the blue color derived from anthocyanins is a crucial objective in agricultural and food chemistry research. The ability of these compounds to bind with metals could potentially stabilize anthocyanins extracted from plant-based foods or enable modifying their hues for application as natural food colorants. This study had two core objectives - first, to extract and identify the major anthocyanin pigments responsible for iris flower coloration. Second, to selectively complex purified iris anthocyanins with aluminum (Al3+) and copper (Cu2+) ions, probing the coordination chemistry underlying synthetic metalloanthocyanin formation. Fresh iris flowers were collected and anthocyanins extracted using an optimized acidic solution. After separation, anthocyanins were complexed with metals Al3+ and Cu2+ at pH 5-6 to understand better the evolution of blue and green colors in anthocyanin-metal chelates. Characterization of anthocyanins and their metal complexes utilized UV-visible spectrometry, colorimetry (L\* a\*b\* values), FTIR spectroscopy, and LC-MS. Metal complexation of anthocyanins exhibited bathochromic shifts of visible absorption maxima from 538 to 584 nm for Al-complex and 538-700 nm for Cu-complex. Color changes were accompanied by decreased lightness (L\*, from 87 to 81) and color coefficients a\* (+5.4 to -6.8) and b\* (-12.2 to -4.8). LC-MS analysis identified five major anthocyanin aglycones: cyanidin (Cyd, m/z 289), delphinidin (Dpd, m/z 305), petunidin (Ptd, m/z 229), malvidin (Mv, m/z 329) and pelargonidin (m/z 273), along with various glycosylated derivatives. This work successfully isolated key iris anthocyanin pigments and elucidated their metal chelation interactions underlying expanded floral color production, bridging knowledge gaps about this underexplored genus.

20.
Cureus ; 16(5): e59435, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38826882

RESUMEN

Aphakia is a condition in which the eye's crystalline lens is not in its proper position because of a perforating injury, surgical removal, dislocation of the lens, or congenital anomaly. The management of aphakia can be either conservative or surgical. Various surgical techniques could be used, including retro pupillary-fixated iris-claw intraocular lenses (IOLs) and anterior-fixated iris-claw IOLs. One of the challenges faced by ophthalmologists is the optical rehabilitation of pediatric aphakic patients because a child's eye is still growing, resulting in fundamental variations in their refractive elements, and the immature visual system faces the risks of amblyopia development in the case of defocus or inequality of visual input between both eyes. There is also the risk of the incidence of side effects that can be accepted in adults but not in children. Finally, accurate postoperative supervision and optical rehabilitation in pediatrics will be more complex than that in adults. This review showed that it is possible to place, replace, and exchange the Artisan IOL with minor surgical trauma. Hence, this procedure can be an acceptable therapeutic method for correcting the developmental refractive changes of the growing aphakic eye. However, some worries are still caused by probable long-term side effects, including endothelial cell loss. Finally, a significant attempt at visual rehabilitation is to treat pediatric aphakia with Artisan IOL.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...