Resultados 1 - 20 de 844
Filtrar
1.
Front Oncol ; 14: 1411474, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39351356

RESUMEN

We present two cases of cardiac metastases adjacent to the right ventricle in a 55-year-old male and a 61-year-old female, both treated with magnetic resonance (MR)-guided adaptive stereotactic radiation therapy (SBRT). The prescribed regimen was 30Gy delivered in 3 fractions using a 1.5 Tesla magnetic resonance linear accelerator (MR-linac). Patients exhibited favorable tolerance to the treatment, with no observed acute toxicity.

2.
Eur J Radiol ; 181: 111735, 2024 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-39276402

RESUMEN

OBJECTIVE: This study aimed to quantitatively evaluate the inter-platform reproducibility and longitudinal acquisition repeatability of MRI radiomics features in Fluid-Attenuated Inversion Recovery (FLAIR), T2-weighted (T2W), and T1-weighted (T1W) sequences on MR-Linac systems using an American College of Radiology (ACR) phantom. MATERIALS AND METHODS: This study used two MR-Linac systems (A and B) in different cancer centers. The ACR phantom was scanned on system A daily for 30 consecutive days to evaluate longitudinal repeatability. Additionally, retest data were collected after repositioning the phantom. Inter-platform reproducibility was assessed by conducting scans under identical conditions using system B. Regions of interest were delineated on the T1W sequence from system A and mapped to other sequences via rigid registration. Intra-observer and inter-observer comparisons were conducted. Repeatability and reproducibility were assessed using the intraclass correlation coefficient (ICC) and coefficient of variation (CV). Robust radiomics features were identified based on ICC>0.9 and CV<10 %. RESULTS: Analysis showed that a higher proportion of radiomics features derived from longitudinal FLAIR sequence (51.65 %) met robustness criteria compared to T2W (48.35 %) and T1W (43.96 %). Additionally, more inter-platform features from the FLAIR sequence (62.64 %) were robust compared to T2W (42.86 %) and T1W (39.56 %). Test-retest and intra-observer repeatability were excellent across all sequences, with a median ICC of 0.99 and CV<5%. However, inter-observer reproducibility was inferior, especially for the T1W sequence. CONCLUSIONS: Different sequences show variations in repeatability and reproducibility. The FLAIR sequence demonstrated advantages in both longitudinal repeatability and inter-platform reproducibility. Caution is warranted when interpreting data, particularly in longitudinal or multiplatform radiomics studies.

3.
Radiat Oncol ; 19(1): 123, 2024 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-39289753

RESUMEN

BACKGROUND: Accelerated partial breast irradiation (APBI) is an accepted treatment option for early breast cancer. Treatment delivered on the Magnetic Resonance integrated Linear Accelerator (MRL) provides the added assurance of improved soft tissue visibility, important in the delivery of APBI. This technique can be delivered in both the supine and prone positions, however current literature suggests that prone treatment on the MRL is infeasible due to physical limitations with bore size. This study aims to investigate the feasibility of positioning patients on a custom designed prone breast board compared with supine positioning on a personalised vacuum bag. Geometric distortion, the relative position of Organs at Risk (OAR) to the tumour bed and breathing motion (intrafraction motion) will be compared between the supine and prone positions. The study will also investigate the positional impact on dosimetry, patient experience, and position preference. METHODS: Up to 30 patients will be recruited over a 12-month period for participation in this Human Research Ethics Committee approved exploratory cohort study. Patients will be scanned on the magnetic resonance imaging (MRI) Simulator in both the supine and prone positions as per current standard of care for APBI simulation. Supine and prone positioning comparisons will all be assessed on de-identified MRI image pairs, acquired using appropriate software. Patient experience will be explored through completion of a short, anonymous electronic survey. Descriptive statistics will be used for reporting of results with categorical, parametric/non-parametric tests applied (data format dependent). Survey results will be interpreted by comparison of percentage frequencies across the Likert scales. Thematic content analysis will be used to interpret qualitative data from the open-ended survey questions. DISCUSSION: The results of this study will be used to assess the feasibility of treating patients with APBI in the prone position on a custom designed board on the MRL. It may also be used to assist with identification of patients who would benefit from this position over supine without the need to perform both scans. Patient experience and technical considerations will be utilised to develop a tool to assist in this process. Trial registration Australian New Zealand Clinical Trials Registry (ANZCTR): ACTRN1262400067583. Registered 28th of May 2024. https://www.anzctr.org.au/ACTRN12624000679583.aspx.


Asunto(s)
Neoplasias de la Mama , Imagen por Resonancia Magnética , Aceleradores de Partículas , Posicionamiento del Paciente , Planificación de la Radioterapia Asistida por Computador , Humanos , Femenino , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Órganos en Riesgo/efectos de la radiación , Dosificación Radioterapéutica , Posición Supina , Posición Prona , Radioterapia de Intensidad Modulada/métodos
4.
Cancers (Basel) ; 16(18)2024 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-39335214

RESUMEN

Background/Objectives: To report on predictive factors in Linac-based SRT for single and multiple BM. Methods: Consecutive patients receiving either one or three fractions of single-isocenter coplanar VMAT SRT were retrospectively included. The GTV-PTV margin was 1-2 mm. The delivered target dose was estimated by recalculating the original plans on roto-translated CT according to errors recorded by post-treatment CBCT. The Kaplan-Meier method estimated local progression-free survival (LPFS), intracranial progression-free survival (IPFS), and overall survival (OS). Log-rank and Wilcoxon-Mann-Whitney tests evaluated inter-group differences, whereas Cox regression analysis assessed prognostic factors. Results: Fifty females and fifty males, with a median age of 69 years, received 107 SRTs. A total of 213 BM (range, 1-10 per treatment) with a median volume of 0.22 cc were irradiated with a median minimum BED of 59.5 Gy. The median delivered GTV D95 reduction was -0.3%. The median follow-up was 11 months. Nineteen LP events and a 1-year LC rate of 90.1% were observed. The GTV coverage did not correlate with LC, while the GTV volume was a risk factor for LP, with the 1-year rate dropping to 73% for volumes ≥ 0.88 cc. The median LPFS, IPFS, and OS were 6, 5, and 7 months, respectively. Multivariate analysis showed that patients with melanoma histology and those receiving a second or subsequent systemic therapy line had the worst outcomes, whereas patients with adenocarcinoma histology and mutations showed better results. Conclusions: The accuracy and efficacy of the Linac-based SRT approach for BM were confirmed, but the dose distribution alone failed to predict the treatment response, suggesting that other factors must be considered to maximize SRT outcomes.

5.
Radiother Oncol ; 200: 110527, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39242030

RESUMEN

BACKGROUND AND PURPOSE: Magnetic resonance (MR)-guided radiotherapy (MRgRT) enhances treatment precision and adaptive capabilities, potentially supporting a simulation-free (sim-free) workflow. This work reports the first clinical implementation of a sim-free workflow using the MR-Linac for prostate cancer patients treated with stereotactic ablative radiotherapy (SABR). MATERIALS AND METHODS: Fifteen patients who had undergone a prostate-specific membrane antigen positron emission tomography/CT (PSMA-PET/CT) scan as part of diagnostic workup were included in this work. Two reference plans were generated per patient: one using PSMA-PET/CT (sim-free plan) and the other using standard simulation CT (simCT plan). Dosimetric evaluations included comparisons between simCT, sim-free, and first fraction plans. Timing measurements were conducted to assess durations for both simCT and sim-free pre-treatment workflows. RESULTS: All 15 patients underwent successful treatment using a sim-free workflow. Dosimetric differences between simCT, sim-free, and first fraction plans were minor and within acceptable clinical limits, with no major violations of standardised criteria. The sim-free workflow took on average 130 min, while the simCT workflow took 103 min. CONCLUSION: This work demonstrates the feasibility and benefits of sim-free MR-guided adaptive radiotherapy for prostate SABR, representing the first reported clinical experience in an ablative setting. By eliminating traditional simulation scans, this approach reduces patient burden by minimising hospital visits and enhances treatment accessibility.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata , Radiocirugia , Planificación de la Radioterapia Asistida por Computador , Radioterapia Guiada por Imagen , Humanos , Masculino , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía , Neoplasias de la Próstata/patología , Radiocirugia/métodos , Radioterapia Guiada por Imagen/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Anciano , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Dosificación Radioterapéutica , Imagen por Resonancia Magnética/métodos , Flujo de Trabajo , Persona de Mediana Edad , Anciano de 80 o más Años
6.
Sci Rep ; 14(1): 22101, 2024 09 27.
Artículo en Inglés | MEDLINE | ID: mdl-39333319

RESUMEN

Stereotactic radiation therapy (SBRT) has emerged as a promising treatment modality for locally advanced pancreatic cancer. The aim of this study is to assess the dosimetric efficacy of online adaptive radiotherapy (ART) in comparison to image-guided radiation therapy (IGRT) for pancreatic cancer. We conducted a retrospective analysis involving 8 patients diagnosed with locally advanced pancreatic cancer. The gross tumor volume (GTV) delineates the visible extent of the tumor on imaging, while the planning tumor volume (PTV) was generated by expanding 5 mm from the GTV and ensuring a 3 mm distance from the small intestine, duodenum, and stomach simultaneously. Treatment planning was executed using the United Imaging Healthcare Treatment Planning System workstation. The control group underwent evaluation based on daily validated fan-beam CT (FBCT) scans, assessing both the dose delivered to actual organs at risk (OARs) and the target volume. Radiotherapy plans were developed utilizing simulation CT, and conventional radiotherapy with daily image-guided radiation therapy (IGRT) was administered using FBCT-Linac. Conversely, patients in the study group received daily validated FBCT-guided adaptive radiotherapy plans, with a focus on mean dose assessment of both the target volume and OARs. Subsequently, we compared the average outcomes of each treatment fraction between IGRT and online adaptive radiotherapy (ART). Comparison between ART and IGRT treatment plans revealed significant differences in various dosimetric parameters: For PTV: V98%: ART (96.28%) vs IGRT (89.73%), p = 0.000, V95%: ART (96.28%) vs IGRT (89.73%), p = 0.031, V90%: ART (98.58%) vs IGRT (93.65%), p = 0.000, Dmean: ART (4912.91) vs IGRT (4804.11), p = 0.000. For GTV: V100%: ART (97.96%) vs IGRT (94.85%), p = 0.314, V98%: ART (100.00%) vs IGRT (96.83%), p = 0.000, V90%: ART (100.00%) vs IGRT (97.75%), p = 0.000, Dmean: ART (4972.17) vs IGRT (4907.23), p = 0.000. For the duodenum: D0.5cc: ART (2883.92) vs IGRT (3359.35), p = 0.000, D1cc: ART (2726.32) vs IGRT (3128.66), p = 0.001, D5cc: ART (2051.96) vs IGRT (2273.93), p = 0.015, D10cc: ART (1650.73) vs IGRT (1731.74), p = 0.211. For the small bowel: D0.5cc: ART (3022.3) vs IGRT (3142.64), p = 0.037. D5cc: ART (2151.09) vs IGRT (2389.15), p = 0.043, D10cc: ART (1775.20) vs IGRT (1942.00), p = 0.079. For the stomach: D0.5cc: ART (3353.92) vs IGRT (4117.85), p = 0.000, D5cc: ART (2860.20) vs IGRT (3235.41), p = 0.000, D10cc: ART (2553.72) vs IGRT (2836.73), p = 0.000. For the Dmean of the left kidney and right kidney: Left kidney: ART (248.28) vs IGRT (239.65), p = 0.100. Right kidney: ART (314.55) vs IGRT (307.17), p = 0.345. These results suggest significant improvements in PTV coverage and sparing of OARs with ART compared to IGRT, indicating the potential of ART in optimizing treatment outcomes for pancreatic cancer patients. Compared to conventional IGRT-guided SBRT programs, ART-based SBRT for pancreatic cancer not only enhances the dose distribution to the target volume but also mitigates the radiation exposure to critical organs-at-risk (OARs) such as the duodenum, small intestine, and stomach. This approach may offer a more favorable safety profile while concurrently enhancing treatment efficacy.


Asunto(s)
Neoplasias Pancreáticas , Radiocirugia , Planificación de la Radioterapia Asistida por Computador , Radioterapia Guiada por Imagen , Humanos , Neoplasias Pancreáticas/radioterapia , Neoplasias Pancreáticas/patología , Neoplasias Pancreáticas/cirugía , Radiocirugia/métodos , Masculino , Femenino , Planificación de la Radioterapia Asistida por Computador/métodos , Estudios Retrospectivos , Anciano , Persona de Mediana Edad , Radioterapia Guiada por Imagen/métodos , Dosificación Radioterapéutica , Órganos en Riesgo/efectos de la radiación , Tomografía Computarizada por Rayos X
7.
Tomography ; 10(9): 1439-1454, 2024 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-39330753

RESUMEN

Magnetic resonance imaging (MRI) is known for its accurate soft tissue delineation of tumors and normal tissues. This development has significantly impacted the imaging and treatment of cancers. Radiomics is the process of extracting high-dimensional features from medical images. Several studies have shown that these extracted features may be used to build machine-learning models for the prediction of treatment outcomes of cancer patients. Various feature selection techniques and machine models interrogate the relevant radiomics features for predicting cancer treatment outcomes. This study aims to provide an overview of MRI radiomics features used in predicting clinical treatment outcomes with machine learning techniques. The review includes examples from different disease sites. It will also discuss the impact of magnetic field strength, sample size, and other characteristics on outcome prediction performance.


Asunto(s)
Aprendizaje Automático , Imagen por Resonancia Magnética , Neoplasias , Humanos , Neoplasias/diagnóstico por imagen , Neoplasias/terapia , Imagen por Resonancia Magnética/métodos , Resultado del Tratamiento , Radioterapia Guiada por Imagen/métodos , Radiómica
8.
Med Phys ; 2024 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-39331834

RESUMEN

BACKGROUND: FLASH radiation therapy (RT) offers a promising avenue for the broadening of the therapeutic index. However, to leverage the full potential of FLASH in the clinical setting, an improved understanding of the biological principles involved is critical. This requires the availability of specialized equipment optimized for the delivery of conventional (CONV) and ultra-high dose rate (UHDR) irradiation for preclinical studies. One method to conduct such preclinical radiobiological research involves adapting a clinical linear accelerator configured to deliver both CONV and UHDR irradiation. PURPOSE: We characterized the dosimetric properties of a clinical linear accelerator configured to deliver ultra-high dose rate irradiation to two anatomic sites in mice and for cell-culture FLASH radiobiology experiments. METHODS: Delivered doses of UHDR electron beams were controlled by a microcontroller and relay interfaced with the respiratory gating system. We also produced beam collimators with indexed stereotactic mouse positioning devices to provide anatomically specific preclinical treatments. Treatment delivery was monitored directly with an ionization chamber, and charge measurements were correlated with radiochromic film measurements at the entry surface of the mice. The setup for conventional dose rate irradiation utilized the same collimation system but at increased source-to-surface distance. Monte Carlo simulations and film dosimetry were used to characterize beam properties and dose distributions. RESULTS: The mean electron beam energies before the flattening filter were 18.8 MeV (UHDR) and 17.7 MeV (CONV), with corresponding values at the mouse surface of 17.2 and 16.2 MeV. The charges measured with an external ion chamber were linearly correlated with the mouse entrance dose. The use of relay gating for pulse control initially led to a delivery failure rate of 20% (± 1 pulse); adjustments to account for the linac latency improved this rate to < 1/20. Beam field sizes for two anatomically specific mouse collimators (4 × 4 cm2 for whole-abdomen and 1.5 × 1.5 cm2 for unilateral lung irradiation) were accurate within < 5% and had low radiation leakage (< 4%). Normalizing the dose at the center of the mouse (∼0.75 cm depth) produced UHDR and CONV doses to the irradiated volumes with > 95% agreement. CONCLUSION: We successfully configured a clinical linear accelerator for increased output and developed a robust preclinical platform for anatomically specific irradiation, with highly accurate and precise temporal and spatial dose delivery, for both CONV and UHDR irradiation applications.

9.
Phys Med Biol ; 69(20)2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-39303742

RESUMEN

Objective.To develop a 2D MR acceleration method utilizing principal component analysis (PCA) in a hybrid fashion for rapid real-time applications.Approach.Retrospective testing was performed on 10 lung, 10 liver and 10 prostate 3T MRI data sets for image quality and target contourability. Sampling of k-space is performed by acquiring central (low-frequency) data in every frame while the high-frequency data is incoherently undersampled such that all of k-space is acquired in a pre-determined number of frames. Firstly, principal components (PCs) representative of intra-frame correlations between central and outer k-space data are used to estimate unsampled data in the frame of interest. Then to add further stability, PCs representative of time-domain fluctuations within a reconstruction window of the most recent frames are fit to outer k-space data (including above estimations) to obtain final estimates in the frame of interest. Accelerated reconstructions between 3x and 8x were tested for image quality and contourability along with the optimal number of PCs for fitting.Main results.It was found that at higher acceleration rates, image quality did not deteriorate significantly. Similarly, it was found that the images were of sufficient quality to contour a target using auto-contouring software at all tested acceleration rates and sites. SSIM values were found to be ⩾0.91 at all accelerations tested. Similarly dice coefficients at the different sites were found to be ⩾0.89 even at 8x accelerations which is on par with or better than intra-observer variation.Significance.This method appears to produce improved image quality and contourability compared to previous PCA methods while also allowing a greater number of PCs to be used in reconstruction. The method can be run using a simple single-channel coil and does not require significant computing power to meet real-time interventional standards (reconstruction times ∼60 ms/frame on Intel i5 CPU).


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Análisis de Componente Principal , Humanos , Imagen por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Factores de Tiempo , Masculino
10.
J Appl Clin Med Phys ; : e14524, 2024 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-39259864

RESUMEN

PURPOSE: This study evaluates the performance of a kilovoltage x-ray image-guidance system equipped with a novel post-processing optimization algorithm on the newly introduced TAICHI linear accelerator (Linac). METHODS: A comparative study involving image quality tests and radiation dose measurements was conducted across six scanning protocols of the kV-cone beam computed tomography (CBCT) system on the TAICHI Linac. The performance assessment utilized the conventional Feldkamp-Davis-Kress (FDK) algorithm and a novel Non-Local Means denoising and adaptive scattering correction (NLM-ASC) algorithm. Image quality metrics, including spatial resolution, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR), were evaluated using a Catphan 604 phantom. Radiation doses for low-dose and standard protocols were measured using a computed tomography dose index (CTDI) phantom, with comparative measurements from the Halcyon Linac's iterative CBCT (iCBCT). RESULTS: The NLM-ASC algorithm significantly improved image quality, achieving a 300%-1000% increase in CNR and SNR over the FDK-only images and it also showed a 100%-200% improvement over the iCBCT images from Halcyon's head protocol. The optimized low-dose protocols yielded higher image quality than the standard FDK protocols, indicating potential for reduced radiation exposure. Clinical implementation confirmed the TAICHI system's utility for precise and adaptive radiotherapy. CONCLUSION: The kV-IGRT system on the TAICHI Linac, with its novel post-processing algorithm, demonstrated superior image quality suitable for routine clinical use, effectively reducing image noise without compromising other quality metrics.

11.
Radiat Oncol ; 19(1): 114, 2024 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-39218934

RESUMEN

BACKGROUND: Magnetic resonance-guided adaptive radiotherapy (MRgART) at MR-Linac allows for plan optimisation on the MR-based synthetic CT (sCT) images, adjusting the target and organs at risk according to the patient's daily anatomy. Conversely, conventional linac image-guided radiotherapy (IGRT) involves rigid realignment of regions of interest to the daily anatomy, followed by the delivery of the reference computed tomography (CT) plan. This study aims to evaluate the effectiveness of MRgART versus IGRT for rectal cancer patients undergoing short-course radiotherapy, while also assessing the dose accumulation process to support the findings and determine its usefulness in enhancing treatment accuracy. METHODS: Nineteen rectal cancer patients treated with a 1.5 Tesla MR-Linac with a prescription dose of 25 Gy (5 Gy x 5) and undergoing daily adapted radiotherapy by plan optimization based on online MR-based sCT images, were included in this retrospective study. For each adapted plan ([Formula: see text]), a second plan ([Formula: see text]) was generated by recalculating the reference CT plan on the daily MR-based sCT images after rigid registration with the reference CT images to simulate the IGRT workflow. Dosimetry of [Formula: see text] and[Formula: see text]was compared for each fraction. Cumulative doses on the first and last fractions were evaluated for both workflows. The dosimetry per single fraction and the cumulative doses were compared using dose-volume histogram parameters. RESULTS: Ninety-five fractions delivered with MRgART were compared to corresponding simulated IGRT fractions. All MRgART fractions fulfilled the target clinical requirements. IGRT treatments did not meet the expected target coverage for 63 out of 94 fractions (67.0%), with 13 fractions showing a V95 median point percentage decrease of 2.78% (range, 1.65-4.16%), and 55 fractions exceeding the V107% threshold with a median value of 15.4 cc (range, 6.0-43.8 cc). For the bladder, the median [Formula: see text] values were 18.18 Gy for the adaptive fractions and 19.60 Gy for the IGRT fractions. Similarly the median [Formula: see text] values for the small bowel were 23.40 Gy and 25.69 Gy, respectively. No statistically significant differences were observed in the doses accumulated on the first or last fraction for the adaptive workflow, with results consistent with the single adaptive fractions. In contrast, accumulated doses in the IGRT workflow showed significant variations mitigating the high dose constraint, nevertheless, more than half of the patients still did not meet clinical requirements. CONCLUSIONS: MRgART for short-course rectal cancer treatments ensures that the dose delivered matches each fraction of the planned dose and the results are confirmed by the dose accumulation process, which therefore seems redundant. In contrast, IGRT may lead to target dose discrepancies and non-compliance with organs at risk constraints and dose accumulation can still highlight notable dosimetric differences.


Asunto(s)
Imagen por Resonancia Magnética , Órganos en Riesgo , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia Guiada por Imagen , Neoplasias del Recto , Humanos , Neoplasias del Recto/radioterapia , Neoplasias del Recto/diagnóstico por imagen , Radioterapia Guiada por Imagen/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Órganos en Riesgo/efectos de la radiación , Masculino , Femenino , Anciano , Persona de Mediana Edad , Radioterapia de Intensidad Modulada/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano de 80 o más Años
12.
Artículo en Inglés | MEDLINE | ID: mdl-39253547

RESUMEN

Purpose: The local management approach for node-positive breast cancer has undergone substantial evolution. Consequently, there exists a pressing need to enhance our treatment strategies by placing greater emphasis on planning and dosimetric factors, given the availability of more conformal techniques and delineation criteria, achieving optimal goals of radiotherapy treatment. The primary aim of this article is to discuss how the extent of regional nodal coverage influences the choice between IMRT and 3D radiation therapy for patients. Patients and Methods: A total of 15 patients diagnosed with left breast cancer with disease involved lymph nodes were included in this study. Delivering the recommended dose required the use of a linear accelerator (LINAC) with photon beams energy of 6 mega voltage (6MV). Each patient had full breast radiation using two planning procedures: intensity-modulated radiotherapy (IMRT) and three-dimensional radiotherapy (3D conformal). Following the guidelines set forth by the Radiation Therapy Oncology Group (RTOG), the planned treatment coverage was carefully designed to fall between 95% and 107% of the recommended dose. Additionally, Dose Volume Histograms (DVHs) were generated the dose distribution within these anatomical contours. Results and Conclusion: The DVH parameters were subjected to a comparative analysis, focusing on the doses absorbed by both Organs at Risk (OARs) and the Planning Target Volume (PTV). The findings suggest that low doses in IMRT plan might raise the risk of adverse oncological outcomes or potentially result in an increased incidence of subsequent malignancies. Consequently, the adoption of inverse IMRT remains limited, and the decision to opt for this therapy should be reserved for situations where it is genuinely necessary to uphold a satisfactory quality of life. Additionally, this approach helps in reducing the likelihood of developing thyroid problems and mitigates the risk of injuries to the supraclavicular area and the proximal head of the humerus bone.

13.
Biomed Phys Eng Express ; 10(5)2024 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-39111326

RESUMEN

Purpose. To evaluate the feasibility of use of an 1.5 T magnetic resonance (MR)-linear accelerator MR-linac for imaging in gynaecologic high-dose-rate (HDR) brachytherapy.Method. Commissioning measurements for MR images quality control, geometric distortion, dwell position accuracy, applicator reconstruction and end-to-end test for a tandem-and-ring applicator were performed following the recommendations of American Brachytherapy Society, International Commission on Radiation Units and Measurements and Report of the Brachytherapy Working Group of the Spanish Society of Medical Physics. The values for MR-based IGABT were compared to the corresponding values with computed tomography (CT).Results. Measured distorsions for the MR images were less than 0.50 mm compared to the CT images. The differences between 3D displacements for all dwell positions were 0.66 mm and 0.62 mm for the tandem and ring, respectively. The maximum difference is 0.64 mm for the distances from the applicator tip obtained using the films. The CT and MR dose differences for the right and left 'A' points were 0.9% and -0.7%, respectively. Similar results were observed in terms of dose distribution for CT and Mr The gamma passing rate was 99.3% and 99.5%, respectively.Conclusion. The use of MR images from an MR-linac used in a radiotherapy service for gynaecological brachytherapy was proved to be feasible, safe and precise as the geometrical differences were less than 1 mm, and the dosimetric differences were less than 1% when comparing to the use of CT images for the same purpose.


Asunto(s)
Braquiterapia , Imagen por Resonancia Magnética , Dosificación Radioterapéutica , Radioterapia Guiada por Imagen , Tomografía Computarizada por Rayos X , Braquiterapia/métodos , Humanos , Femenino , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Radioterapia Guiada por Imagen/métodos , Aceleradores de Partículas , Neoplasias de los Genitales Femeninos/radioterapia , Neoplasias de los Genitales Femeninos/diagnóstico por imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Fantasmas de Imagen , Estudios de Factibilidad
14.
Rep Pract Oncol Radiother ; 29(1): 10-20, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39165591

RESUMEN

Background: We analyzed a dose escalation of 36.25 Gy to the entire prostate and a dose increment up to 40 Gy with 1.25 Gy increments to intraprostatic lesion (IPL) using simultaneous integrated boost (SIB) in five fractions. Materials and methods: Eighteen low- and intermediate-risk prostate cancer patients treated with 1.5T MR-Linac were retrospectively evaluated. The same planning computed tomography (CT) images generated four plans: no SIB, 37.5 Gy SIB, 38.75 Gy SIB, and 40 Gy SIB. In four plans, planning target volume (PTV) doses, organ at risk (OAR) doses, and PTV-SIB homogeneity index (HI), gradient index (GI) and conformity index (CI) were compared. Results: All plans met the criteria for PTV and PTV-SIB coverage. PTV 40 Gy plan has higher maximum PTV and PTV-SIB doses than other plans. The PTV HI was significantly higher in the SIB 40 Gy plan (0.135 ± 0.007) compared to SIB 38.75 Gy plan (0.099 ± 0.007; p = 0.001), SIB 37.5 Gy (0.067 ± 0.008; p < 0.001), and no SIB plan (0.049 ± 0.010; p < 0.001), while there were no significant differences in HI, GI and CI for PTV-SIB between three plans. Four rectum and bladder plans had similar dosimetric parameters. The urethra D5 was significantly higher in SIB 40 Gy plan compared to no SIB plan (37.7 ± 1.1 Gy vs. 37.0 ± 0.7 Gy; p = 0.009) and SIB 37.5 Gy plan (36.9 ± 0.8 Gy; p = 0.008). There was no significant difference in monitor units between the four consecutive plans. Conclusions: Ultra-hypofractionated dose escalation to IPL up to 40 Gy in 5 fractions with a 1.5-T MR-linac is dosimetrically feasible, potentially paving the way for clinical trials.

15.
Radiother Oncol ; 199: 110468, 2024 10.
Artículo en Inglés | MEDLINE | ID: mdl-39111637

RESUMEN

BACKGROUND AND PURPOSE: Radiation-induced pneumonitis (RP), diagnosed 6-12 weeks after treatment, is a complication of lung tumor radiotherapy. So far, clinical and dosimetric parameters have not been reliable in predicting RP. We propose using non-contrast enhanced magnetic resonance imaging (MRI) based functional parameters acquired over the treatment course for patient stratification for improved follow-up. MATERIALS AND METHODS: 23 lung tumor patients received MR-guided hypofractionated stereotactic body radiation therapy at a 0.35T MR-Linac. Ventilation- and perfusion-maps were generated from 2D-cine MRI-scans acquired after the first and last treatment fraction (Fx) using non-uniform Fourier decomposition. The relative differences in ventilation and perfusion between last and first Fx in three regions (planning target volume (PTV), lung volume receiving more than 20Gy (V20) excluding PTV, whole tumor-bearing lung excluding PTV) and three dosimetric parameters (mean lung dose, V20, mean dose to the gross tumor volume) were investigated. Univariate receiver operating characteristic curve - area under the curve (ROC-AUC) analysis was performed (endpoint RP grade≥1) using 5000 bootstrapping samples. Differences between RP and non-RP patients were tested for statistical significance with the non-parametric Mann-Whitney U test (α=0.05). RESULTS: 14/23 patients developed RP of grade≥1 within 3 months. The dosimetric parameters showed no significant differences between RP and non-RP patients. In contrast, the functional parameters, especially the relative ventilation difference in the PTV, achieved a p-value<0.05 and an AUC value of 0.84. CONCLUSION: MRI-based functional parameters extracted from 2D-cine MRI-scans were found to be predictive of RP development in lung tumor patients.


Asunto(s)
Neoplasias Pulmonares , Imagen por Resonancia Magnética , Neumonitis por Radiación , Humanos , Neumonitis por Radiación/etiología , Neumonitis por Radiación/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/diagnóstico por imagen , Masculino , Femenino , Anciano , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Radiocirugia/efectos adversos , Radiocirugia/métodos , Anciano de 80 o más Años , Imagen de Perfusión/métodos
16.
Phys Med Biol ; 69(17)2024 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-39137816

RESUMEN

Objective. In 1.5 T MR-linacs, the absorbed dose central axis (CAX) deviates from the beam's CAX due to inherent profile asymmetry. In addition, a measured CAX deviation may be biased due to potential lateral (to the beam) effective point of measurement (EPOML) shifts of the detector employed. By investigating CAX deviations, the scope of this study is to determine a set ofEPOMLshifts for profile measurements in 1.5 T MR-linacs.Approach. The Semiflex 3D ion chamber and microDiamond detector (PTW, Germany) were considered in the experimental study while three more detectors were included in the Monte Carlo (MC) study. CAX deviations in the crossline and inline profiles were calculated based on inflection points of the 10×10 cm2field, at five centers. In MC simulations, the experimental setup was reproduced. A small water voxel was simulated to calculate CAX deviation without the impact of the detector-specificEPOMLshift.Main results. All measurements were consistent among the five centers. MC-based and experimental measurements were in agreement within uncertainties. Placing the microDiamond in the vertical orientation does not appear to affect the detector'sEPOML, which is on its central longitudinal axis. For the Semiflex 3D in the crossline direction, the CAX deviation was 2.3 mm, i.e. 1 mm larger than the ones measured using the microDiamond and simulated considering the ideal water detector. Thus, anEPOMLshift of 1 mm is recommended for crossline profile measurements under both Semiflex 3D orientations. For the inline profile, anEPOMLshift of -0.5 mm was determined only for the parallel configuration. In the MC study, CAX deviations were found detector- and orientation-dependent. The dead volume is responsible for theEPOMLshift only in the inline profile and under the parallel orientation.Significance. This work contributes to data availability on the correction or mitigation of the magnetic field-induced changes in the detectors' response.


Asunto(s)
Imagen por Resonancia Magnética , Método de Montecarlo , Aceleradores de Partículas , Imagen por Resonancia Magnética/instrumentación , Radiometría/instrumentación , Radiometría/métodos
17.
Front Oncol ; 14: 1441227, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39184046

RESUMEN

Introduction: This work presents a method to treat stereotactic body radiation therapy (SBRT) for pancreatic cancer on a magnetic resonance-guided linear accelerator (MR-linac) using daily adaptation, real-time motion monitoring, and abdominal compression. Methods: The motion management and treatment planning process involves a magnetic resonance imaging (MRI) simulation with cine and 3D images, a computed tomography (CT) simulation with a breath-hold CT and a 4DCT, pre-treatment verification and planning MRI, and intrafraction MRI cine images. Results: The results from 26 patients were included in this work. Our motion management process results in consistent motion analysis on the CT simulation, MRI simulation, and each treatment fraction. The liver dome was found to be an overestimate of tumor superior/inferior (SI) motion for most patients. Adding compression reduced SI liver dome motion by 6.2 mm on average. Clinical outcomes are similar to those observed in the literature. Conclusions: In this work, we demonstrate how pancreatic SBRT can be successfully treated on an MR-linac using abdominal compression. This allows for an increased duty cycle compared to gating and/or breath-hold techniques.

18.
Clin Transl Radiat Oncol ; 48: 100816, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39130107

RESUMEN

Background and purpose: Peer review is an important component of quality assurance in radiotherapy. To our knowledge, there are no studies reporting on the feasibility and outcomes of the peer review process for magnetic resonance (MR) guided radiotherapy (MRgRT) on the MR linear accelerator (MR-Linac) despite the planning complexity involved and its evolving clinical indications. This study aimed to quantify the rate of change in treatment plans post-peer review and the time and resources required. Materials and methods: Fifty-five cases presented at weekly MR-Linac peer review meetings across two centres from 8 June to 21 September 2023 were prospectively collected. Cases were analysed to determine the rate and extent of plan changes based on the Peer Review Audit Tool for radiation oncology (PRAT) developed by the Royal Australian and New Zealand College of Radiologists (RANZCR). Results: Peer review resulted in changes to 36.4 % of treatment plans (n = 20), with 3.6 % (n = 2) having major changes requiring deferment of treatment. The most frequent changes were to organs at risk (OAR) volumes involving both delineation and increased OAR sparing (16.4 %, n = 9), total dose and fractionation (10.9 %, n = 6) and target volume dose coverage (5.5 %, n = 3). Patients with SBRT plans (39.1 % cf 22.2 %), oligometastatic/oligoprogressive sites (38.1 % cf 30.7 %) and reirradiation cases (41.2 % cf 34.2 %) had higher rates of change. Cases took a mean of 7 min (range 2-15 minutes) to discuss. Conclusion: The high rates of plan changes support the value of peer review in MRgRT. We recommend, where possible that all MRgRT cases, particularly those involving SBRT plans, oligometastatic/oligoprogressive sites, and/or reirradiation, be subject to peer review.

19.
Med Phys ; 2024 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-39140821

RESUMEN

BACKGROUND: Stereotactic MR-guided Adaptive Radiation Therapy (SMART) dose painting for hypoxia has potential to improve treatment outcomes, but clinical implementation on low-field MR-Linac faces substantial challenges due to dramatically lower signal-to-noise ratio (SNR) characteristics. While quantitative MRI and T1 mapping of hypoxia biomarkers show promise, T1-to-noise ratio (T1NR) optimization at low fields is paramount, particularly for the clinical implementation of oxygen-enhanced (OE)-MRI. The 3D Magnetization Prepared (2) Rapid Gradient Echo (MP2RAGE) sequence stands out for its ability to acquire homogeneous T1-weighted contrast images with simultaneous T1 mapping. PURPOSE: To optimize MP2RAGE for low-field T1 mapping; conduct experimental validation in a ground-truth phantom; establish feasibility and reproducibility of low-field MP2RAGE acquisition and T1 mapping in healthy volunteers. METHODS: The MP2RAGE optimization was performed to maximize the contrast-to-noise ratio (CNR) of T1 values in white matter (WM) and gray matter (GM) brain tissues at 0.35T. Low-field MP2RAGE images were acquired on a 0.35T MR-Linac (ViewRay MRIdian) using a multi-channel head coil. Validation of T1 mapping was performed with a ground-truth Eurospin phantom, containing inserts of known T1 values (400-850 ms), with one and two average (1A and 2A) MP2RAGE scans across four acquisition sessions, resulting in eight T1 maps. Mean (± SD) T1 relative error, T1NR, and intersession coefficient of variation (CV) were determined. Whole-brain MP2RAGE scans were acquired in 5 healthy volunteers across two sessions (A and B) and T1 maps were generated. Mean (± SD) T1 values for WM and GM were determined. Whole-brain T1 histogram analysis was performed, and reproducibility was determined with the CV between sessions. Voxel-by-voxel T1 difference maps were generated to evaluate 3D spatial variation. RESULTS: Low-field MP2RAGE optimization resulted in parameters: MP2RAGETR of 3250 ms, inversion times (TI1/TI2) of 500/1200 ms, and flip angles (α1/α2) of 7/5°. Eurospin T1 maps exhibited a mean (± SD) relative error of 3.45% ± 1.30%, T1NR of 20.13 ± 5.31, and CV of 2.22% ± 0.67% across all inserts. Whole-brain MP2RAGE images showed high anatomical quality with clear tissue differentiation, resulting in mean (± SD) T1 values: 435.36 ± 10.01 ms for WM and 623.29 ± 14.64 ms for GM across subjects, showing excellent concordance with literature. Whole-brain T1 histograms showed high intrapatient and intersession reproducibility with characteristic intensity peaks consistent with voxel-level WM and GM T1 values. Reproducibility analysis revealed a CV of 0.46% ± 0.31% and 0.35% ± 0.18% for WM and GM, respectively. Voxel-by-voxel T1 difference maps show a normal 3D spatial distribution of noise in WM and GM. CONCLUSIONS: Low-field MP2RAGE proved effective in generating accurate, reliable, and reproducible T1 maps with high T1NR in phantom studies and in vivo feasibility established in healthy volunteers. While current work is focused on refining the MP2RAGE protocol to enable clinically efficient OE-MRI, this study establishes a foundation for TOLD T1 mapping for hypoxia biomarkers. This advancement holds the potential to facilitate a paradigm shift toward MR-guided biological adaptation and dose painting by leveraging 3D hypoxic spatial distributions and improving outcomes in conventionally challenging-to-treat cancers.

20.
Artículo en Inglés | MEDLINE | ID: mdl-39153061

RESUMEN

The aim of this work was to evaluate the conformity of intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT), and verify the accuracy of the planning and delivery system used in this work based on the AAPM TG-119 protocol. The Eclipse 13.6 treatment planning system (TPS) was used to plan the TG-119 test suite, which included four test cases: MultiTarget, Prostate, Head/Neck, and C-Shape for IMRT and VMAT techniques with 6 MV and 10 MV acceleration voltages. The results were assessed and discussed in terms of the TG-119 protocol and the results of previous studies. In addition, point dose and planar dose measurements were done using a semiflex ion chamber and an electronic portal imaging device (EPID), respectively. The planned doses of all test cases met the criteria of the TG-119 protocol, except those for the spinal cord of the C-Shape hard case. There were no significant differences between the treatment planning doses and the doses given in the TG-119 report, with p-values ranging from 0.974 to 1 (p > 0.05). Doses to the target volumes were similar in the IMRT and VMAT plans, but the organs at risk (OARs) doses were different depending on the test case. The planning results showed that IMRT is more conformal than VMAT in certain cases. For the point dose measurements, the confidence limit (CLpoint) of 0.030 and 0.021 were better than the corresponding values of 0.045 and 0.047 given in the TG-119 report for high-dose and low-dose areas, respectively. Regarding the planar dose measurements, the CLplanar value of 0.38 obtained in this work was lower than that given in the TG-119 report (12.4). It is concluded that the dosimetry measurements performed in this study showed better confidence limits than those provided in the TG 119 report. IMRT remains more conformal in certain circumstances than the more progressive VMAT. When selecting the method of delivering a dose to the patient, several factors must be considered, including the radiotherapy technique, energy, treatment site, and tumour geometry.