Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 589
Filtrar
1.
Biosens Bioelectron ; 263: 116598, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39094292

RESUMEN

Antibody pairs-based immunoassay platforms served as essential and effective tools in the field of pathogen detection. However, the cumbersome preparation and limited detection sensitivity of antibody pairs challenge in establishment of a highly sensitive detection platform. In this study, using COVID-19 testing as a case, we utilized readily accessible nanobodies as detection antibodies and further proposed an accurate design concept with a more scientific and efficient screening strategy to obtain ultrasensitive antibody pairs. We employed nanobodies capable of binding different antigenic epitopes of the nucleocapsid (NP) or receptor-binding domain (RBD) antigens sandwich as substitutes for monoclonal antibodies (mAbs) sandwich in fast detection formats and utilized time-resolved fluorescence (TRF) microspheres as the signal probe. Consequently, we developed a multi-epitope nanobody sandwich-based fluorescence lateral flow immunoassay (FLFA) strip. Our results suggest that the NP antigen had a detection limit of 12.01pg/mL, while the RBD antigen had a limit of 6.51 pg/mL using our FLFA strip. Based on double mAb sandwiches, the values presented herein demonstrated 4 to 32-fold enhancements in sensitivity, and 32 to 256-fold enhancements compared to commercially available antigen lateral flow assay kits. Furthermore, we demonstrated the excellent characteristics of the proposed test strip, including its specificity, stability, accuracy, and repeatability, which underscores its the prospective utility. Indeed, these findings indicate that our established screening strategy along with the multi-epitope nanobody sandwich mode provides an optimized strategy in the field of pathogen detection.

2.
J Agric Food Chem ; 2024 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-39092884

RESUMEN

Conventional lateral flow immunoassay (LFIA) usually suffers from poor antimatrix interference, unsatisfactory sensitivity, and lack of quantitative ability for target analyte detection in food matrices. In response to these limits, here, multifunctional nanomaterial ZnFe2O4 nanoparticles (ZFOs) were developed and integrated into LFIA for powerful magnetic separation/enrichment and colorimetric/photothermal target sensing. Under optimum conditions, the detection for clenbuterol (CL) with magnetic enrichment achieves 9-fold higher sensitivity compared to that without enrichment and 162-fold higher sensitivity compared to that based on traditional colloidal golds. Attributing the improved performances of ZFOs, CL can be detected at ultralow levels in pork and milk with 10 min of immunoreaction time. The vLODs were 0.01 µg kg-1 for two modes, and the cutoff values of CL were about 5 and 3 µg kg-1, respectively. More importantly, the enrichment ZFO-mediated LFIA (ZE-LFIA) exhibits a similar limit of detection (LOD) in both buffer solution and food matrix, demonstrating a universal resistance to the food matrix. The multitudinous performance merits of this ZE-LFIA with high sensitivity, matrix tolerance, accuracy, and specificity have ensured a broad application potential for target detection of clenbuterol and can serve as an experience for other veterinary drug residues' detection.

3.
Biosens Bioelectron ; 263: 116590, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39096764

RESUMEN

Diabetes is a chronic disease with significant complications, necessitating regular treatment and checkups, which can be costly and time-consuming for patients. To address this, we developed the Sliding Microneedle (MN)-Lateral flow immunoassay strip (LFIAs) device that combines the advantages of MNs and LFIAs to detect IL-6, an independent biomarker for diabetes complications. This device offers rapid and highly sensitive detection of IL-6 by extracting interstitial fluid (ISF) through MNs and transferring it to LFIAs. The stainless MN, embedded in the 3D-printed Sliding MN-LFIAs device, was inserted into the skin at a 20° angle, minimizing blood contamination risk. With a filter paper attached to the MN surface, the device collected 4.65 ± 0.05 µL of ISF containing IL-6 within 90 s. The ISF was then transferred to the LFIAs using a running buffer. After a 15-min reaction, silver enhancement (SE) treatment was applied, allowing for the highly sensitive and specific detection of IL-6 at 102 pg/mL concentrations. The Sliding MN-LFIAs device successfully distinguished between normal and diabetic rat models, demonstrating its potential as an effective tool for detecting diabetes complications quickly and affordably.

4.
Molecules ; 29(15)2024 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-39125086

RESUMEN

Interleukin-6 (IL-6) detection and monitoring are of great significance for evaluating the progression of many diseases and their therapeutic efficacy. Lateral flow immunoassay (LFIA) is one of the most promising point-of-care testing (POCT) methods, yet suffers from low sensitivity and poor quantitative ability, which greatly limits its application in IL-6 detection. Hence, in this work, we integrated Aushell nanoparticles (NPs) as new LFIA reporters and achieved the colorimetric and photothermal dual-mode detection of IL-6. Aushell NPs were conveniently prepared using a galvanic exchange process. By controlling the shell thickness, their localized surface plasmon resonance (LSPR) peak was easily tuned to near-infrared (NIR) range, which matched well with the NIR irradiation light. Thus, the Aushell NPs were endowed with good photothermal effect. Aushell NPs were then modified with IL-6 detection antibody to construct Aushell probes. In the LFIA detection, the Aushell probes were combined with IL-6, which were further captured by the capture IL-6 antibody on the test line of the strip, forming a colored band. By observation with naked eyes, the colorimetric qualitative detection of IL-6 was achieved with limit of 5 ng/mL. By measuring the temperature rise of the test line with a portable infrared thermal camera, the photothermal quantitative detection of IL-6 was performed from 1~1000 ng/mL. The photothermal detection limit reached 0.3 ng/mL, which was reduced by nearly 20 times compared with naked-eye detection. Therefore, this Aushell-based LFIA efficiently improved the sensitivity and quantitative ability of commercial colloidal gold LFIA. Furthermore, this method showed good specificity, and kept the advantages of convenience, speed, cost-effectiveness, and portability. Therefore, this Aushell-based LFIA exhibits practical application potential in IL-6 POCT detection.


Asunto(s)
Colorimetría , Oro , Interleucina-6 , Interleucina-6/análisis , Oro/química , Inmunoensayo/métodos , Colorimetría/métodos , Humanos , Nanocáscaras/química , Resonancia por Plasmón de Superficie/métodos , Nanopartículas del Metal/química , Límite de Detección , Técnicas Biosensibles/métodos
5.
Anal Biochem ; 694: 115634, 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39094782

RESUMEN

Lateral-flow immunoassays (LFAs) can be used to diagnose urinary tract infections caused by Escherichia coli (E. coli) at the point of care. Unfortunately, urine samples containing dilute concentrations of E. coli can yield false negative results on LFAs. Our laboratory was first to implement aqueous two-phase systems (ATPSs) to preconcentrate samples into smaller volumes prior to their application on LFAs. This is achieved by manipulating the ratio of the volume of the top phase to that of the bottom phase (volume ratio; VR) and concentrating biomarkers in the bottom phase which, when applied to LFAs in fixed volumes, leads to corresponding improvements in sensitivity. This work is the first demonstration that the same LOD can be achieved irrespective of the VR when the entire bottom phase is added to LFAs. A custom 3D-printed device was also developed to decrease liquid handling steps. Across different VRs expected from patient urine variability, this diagnostic workflow successfully detected E. coli concentrations down to 2 × 105 colony-forming units (cfu) mL-1 in synthetic urine, demonstrating consistent 10-fold improvements in sensitivity compared to trials conducted without ATPS preconcentration. This method successfully addresses the variability of patient samples while remaining easy to use at the point of care.

6.
Biosens Bioelectron ; 262: 116556, 2024 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-38996596

RESUMEN

The multiple-readout capability of multimodal detection enhances the flexibility, reliability, and accuracy of lateral flow immunoassay (LFIA). The conjugation of two different metal-organic frameworks (MOFs) as a new-generation composite material offers extraordinary opportunities for developing multimodal LFIA. It is anticipated to compensate limitations of traditional single colorimetric signal LFIA and improve the analysis performance. Herein, an ultra-bright fluorescent AIE-MOF was proposed and coupled with an in-situ growth of Prussian blue (PB) nanoparticles strategy to obtain a novel multimodal signal tracer (AIE-MOF@PB). Thereafter, it was successfully applied to develop the multimodal LFIA platform for the detection of nitrofurazone metabolites. The synergy of AIE-MOF and PB endows AIE-MOF@PB with superb water dispersibility, robust fluorescence emission, brilliant colorimetric signal, marvelous photothermal conversion, and enhanced antibody coupling efficiency, all of which facilitate a highly sensitive triple-readout LFIA platform. The detection sensitivity improved by at least 5-fold compared with the colloidal gold-based LFIA. This work not only inspires the rational design of aggregation-induced emission luminogens (AIEgen)-based complex materials but also highlights the promising potential in flexible point-of-care applications.


Asunto(s)
Técnicas Biosensibles , Límite de Detección , Estructuras Metalorgánicas , Nitrofurazona , Estructuras Metalorgánicas/química , Inmunoensayo/métodos , Inmunoensayo/instrumentación , Técnicas Biosensibles/métodos , Nitrofurazona/análisis , Nitrofurazona/química , Humanos , Ferrocianuros/química , Colorimetría/métodos , Colorantes Fluorescentes/química
7.
J Hazard Mater ; 477: 135296, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39059293

RESUMEN

A lateral flow immunoassay strip (LFIAS) is one of the most frequently rapid test technologies for carbofuran (CAR). Nevertheless, the LFIAS has a poor quantitative capability and low sensitivity. And, it also requires often complex sample handling steps, making testing time longer. In this study, Fe3O4 nanoparticles were successively modified with MIL-100(Fe)-based metal-organic framework (MOF) and chloroplatinic acid hexahydrate to obtain a core-shell complex of Fe3O4-MOF-Pt. The complex had a peroxidase-mimicking activity catalytic function that enabled signal amplification and sensitivity enhancement. Upon coupling with carbofuran monoclonal antibody (CAR-mAb), the magnetic separation properties of the probe enabled target-specific enrichment. The LFIAS based on Fe3O4-MOF-Pt nanocomposites could detect CAR in the range of 0.25-50 ng mL-1 with a limit of detection (LOD) of 0.15 ng mL-1, enabling colorimetric and catalytic analysis. In addition, the method showed high specificity and stability for detecting CAR in various vegetables, and recovery rates of the spiked samples were 91.40%-102.40%. In conclusion, this study provided one-stop detection of "target enrichment-visual inspection". While lowering the LOD, it reduced the detection time and improved the detection efficiency. The multifunctional Fe3O4-MOF-Pt nanocomposite provides an idea for the construction of novel multifunctional probes to improve the detection performance of conventional LFIAS.

8.
Front Microbiol ; 15: 1439273, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39021636

RESUMEN

Introduction: Candida auris is a recently discovered yeast with a multi-drug resistant profile associated with high mortality rates. The rapid identification of Candida auris in hospital settings is crucial to allow appropriate therapeutic and rapid implementation of infection management measures. The aim of this study was to develop a lateral flow immunoassay (LFIA) for the rapid identification of Candida auris. Methods: Highly specific monoclonal antibodies were obtained by immunizing mice with membrane proteins from Candida auris which were then used to develop a LFIA whose performance was assessed by testing 12 strains of Candida auris and 37 strains of other Candida species. Isolates were grown on either Sabouraud dextrose, CHROMagarTM Candida Plus or HardyCHROMTM Candida + auris agar plates. The strains were also cultured on salt sabouraud-dextrose with chloramphenicol or a commercially available Salt-Sabouraud Dulcitol Broth with chloramphenicol and gentamicin, and processed using a simple centrifugation protocol to recover a pellet. Finally, the colonies or yeast extract were transferred to the LFIA to determine the specificity and sensitivity of the assay. Results: The LFIA reached 100% specificity and sensitivity from solid agar plates. For both enrichment broths, some Candida non-auris species were able to grow, but the LFIA remained 100% specific. The use of a dextrose-based sabouraud broth resulted in earlier identification with the LFIA, with most of the Candida auris strains detected at 24 h. Conclusion: The developed LFIA prototype represents a powerful tool to fight the emerging threat of Candida auris. Clinical validation represents the next step.

9.
Small Methods ; : e2400738, 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39082595

RESUMEN

Catalytic nanoparticle@metal-organic framework (MOF) composites have attracted significant interest in point-of-care testing (POCT) owing to their prominent catalytic activity. However, the trade-off between high loading efficiency and high catalytic activity remains challenging because high concentrations of nanoparticles tend to cause the misjoining and collapse of the MOFs. Herein, a facile strategy is reported to encapsulate high concentrations of platinum (Pt) nanoparticles into zeolitic imidazolate framework-8 (ZIF-8) using polydopamine (PDA) as a support for Pt@ZIF-8 and as a flexible scaffold for further immobilization of Pt nanoparticles. The resulting composite (Pt@ZIF-8@PDA@Pt) exhibits ultrahigh Pt nanoparticle loading efficiency, exceptional catalytic activity, stability, and a bright colorimetric signal. Following integration with lateral flow immunoassay (LFIA), the detection limits for pre- and post-catalysis detection of B-type natriuretic peptide (NT-proBNP) are 0.18 and 0.015 ng mL-1, respectively, representing a 6-fold and 70-fold improvement compared to gold nanoparticle-based LFIA. Moreover, Pt@ZIF-8@PDA@Pt-based LFIA achieves 100% diagnostic sensitivity for NT-proBNP in a cohort of 184 clinical samples.

10.
Small ; : e2402676, 2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38847072

RESUMEN

Fluorescent lateral flow immunoassays (FLFIA) is a well-established rapid detection technique for quantitative analysis. However, achieving accurate analysis of biomarkers at the pg mL-1 level using FLFIA still poses challenges. Herein, an ultrasensitive FLFIA platform is reported utilizing a kiwi-type magneto-fluorescent silica nanohybrid (designated as MFS) that serves as both a target-enrichment substrate and an optical signal enhancement label. The spatially-layered architecture comprises a Fe3O4 core, an endocarp-fibers like dendritic mesoporous silica, seed-like quantum dots, and a kiwi-flesh like silica matrix. The MFS demonstrates heightened fluorescence brightness, swift magnetic response, excellent size uniformity, and dispersibility in water. Through liquid-phase capturing and fluorescence-enhanced signal amplification, as well as magnetic-enrichment sample amplification and magnetic-separation noise reduction, the MFS-based FLFIA is successfully applied to the detection of cardiac troponin I that achieved a limit of detection at 8.4 pg mL-1, tens of times lower than those of previously published fluorescent and colorimetric lateral flow immunoassays. This work offers insights into the strategic design of magneto-fluorescent synergetic signal amplification on LFIA platform and underscores their prospects in high-sensitive rapid and on-site diagnosis of biomarkers.

11.
J Dairy Sci ; 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38825130

RESUMEN

Our objectives were to develop and evaluate an integrated system consisting of a lateral-flow immunoassay (LFIA) and an electronic portable imaging device for determination of pregnancy status of cows based on plasma concentrations of pregnancy-specific protein B (PSPB). Experiment 1 was conducted to test the performance of the LFIA for PSPB (PSPB-LFIA) whereas experiment 2 was conducted to evaluate the performance of the integrated system including both the LFIA and imaging device. The PSPB-LFIA strips were made of nitrocellulose membrane with polystreptavidin, anti-mouse antibody, Europium-anti-PSPB conjugates, and biotin-PSPB. After adding buffer and plasma in a 96-well plate, strips were dipped to initiate flow and were read in a fluorescence microscope to estimate PSPB concentrations based on the test-to-control line signal (T/C ratio). The T/C ratio of standards was linearly associated with PSPB (R2 = 0.99 in both experiments) concentrations. To test the ability to identify pregnant cows of the PSPB-LFIA only or the integrated system, plasma samples were collected and transrectal ultrasonography (TUS) was conducted 29 to 35 d post AI in lactating Holstein cows (Experiment 1: n = 83; Experiment 2: n = 205). A cow was considered pregnant (Preg) if concentrations of PSPB in plasma obtained by ELISA were ≥2 ng/mL or if an embryo was visible by TUS. In Experiment 1, the accuracy of the PSPB-LFIA compared with ELISA was 92.7% (91.2% Se; 96.1% Sp; 98.1% PPV; 83.3% NPV) and compared with TUS was 90.4% (100% Se; 78.9% Sp; 84.9% PPV; 100% NPV). The agreement between LFIA and ELISA (kappa = 0.84; 95%CI 0.71-0.96) or LFIA and TUS (kappa = 0.80; 95%CI 0.67-0.93) as methods to classify cows as Preg or Non-Preg was high. In Experiment 2, the accuracy of the PSPB-LFIA compared with ELISA was 96.1% (93.8% Se; 100% Sp; 100% PPV; 90.5% NPV) and compared with TUS was 92.2% (99.0% Se; 84.7% Sp; 87.6% PPV; 98.8% NPV). The agreement between LFIA and ELISA (kappa = 0.92; 95%CI 0.86-0.97) or LFIA and TUS (kappa = 0.84; 95%CI 0.77-0.92) as methods to classify cows as Preg or Non-Preg was high. We conclude that a system integrating a fluorescence-based LFIA and an optical reader was effective for classifying cows as pregnant or not pregnant based on estimations of plasma concentrations of PSPB. This novel system serves as a platform for further development of on-farm pregnancy testing tools based on measurement of biomarkers of pregnancy in bodily fluids of cattle.

12.
Biosensors (Basel) ; 14(6)2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38920567

RESUMEN

The spread of the FluA virus poses significant public health concerns worldwide. Fluorescent lateral flow immunoassay (LFIA) test strips have emerged as vital tools for the early detection and monitoring of influenza infections. However, existing quantitative virus-detection methods, particularly those utilizing smartphone-based sensing platforms, encounter accessibility challenges in resource-limited areas and among the elderly population. Despite their advantages in speed and portability, these platforms often lack user-friendliness for these demographics, impeding their widespread utilization. To address these challenges, this study proposes leveraging the optical pick-up unit (OPU) sourced from commercial optical drives as a readily available fluorescence excitation module for the quantitative detection of antibodies labeled with quantum-dot fluorescent microspheres. Additionally, we utilize miniaturized and high-performance optical components and 3D-printed parts, along with a customized control system, to develop an affordable point-of-care testing (POCT) device. Within the system, a stepping motor scans the test strip from the T-line to the C-line, enabling the calculation of the fluorescence-intensity ratio between the two lines. This simple yet effective design facilitates rapid and straightforward field or at-home testing for FluA. The proposed prototype platform demonstrates promising performance, achieving a limit of detection (LOD) of 2.91 ng/mL, a total detection time of no more than 15 min, and dimensions of 151 mm × 11.2 mm × 10.8 mm3. We believe that the proposed approach holds great potential for improving access to an accurate influenza diagnosis.


Asunto(s)
Gripe Humana , Inmunoensayo , Humanos , Gripe Humana/diagnóstico , Gripe Humana/virología , Virus de la Influenza A/aislamiento & purificación , Técnicas Biosensibles , Fluorescencia , Pruebas en el Punto de Atención , Puntos Cuánticos , Sistemas de Atención de Punto
13.
Biosensors (Basel) ; 14(6)2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38920609

RESUMEN

Lateral flow immunoassays (LFIAs) are recognized for their practicality in homecare and point-of-care testing, owing to their simplicity, cost-efficiency, and rapid visual readouts. Despite these advantages, LFIAs typically fall short in sensitivity, particularly in detecting viruses such as SARS-CoV-2, thus limiting their broader application. In response to this challenge, we have innovated an approach to substantially enhance LFIA sensitivity. This involves the integration of a water-soluble dextran-methacrylate polymer wall with a 15% grafting degree positioned between the test and control lines on the LFIA strip. This novel modification significantly improved the sensitivity of the assay, achieving detection limits as low as 50 pg mL-1 and enhancing the sensitivity by 5-20-fold relative to existing LFIA kits available on the market. Furthermore, our developed LFIA kit (WSPW-LFIA) demonstrated exceptional specificity for SARS-CoV-2. Coupled with a straightforward fabrication process and robust stability, the WSPW-LFIA represents a promising advancement for real-time in vitro diagnosis across a spectrum of diseases.


Asunto(s)
COVID-19 , Polímeros , SARS-CoV-2 , SARS-CoV-2/inmunología , Humanos , COVID-19/diagnóstico , Inmunoensayo/métodos , Polímeros/química , Técnicas Biosensibles , Antígenos Virales/análisis , Agua , Sensibilidad y Especificidad , Límite de Detección , Prueba Serológica para COVID-19/métodos , Dextranos
14.
Foods ; 13(12)2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38928787

RESUMEN

In the realm of analysis, the lateral flow immunoassay (LFIA) is frequently utilized due to its capability to be fast and immediate. However, the biggest challenge of the LFIA is its low detection sensitivity and tolerance to matrix interference, making it impossible to enable accurate, qualitative analyses. In this study, we developed a new LFIA with higher affinity and sensitivity, based on a nanobody (G8-DIG) and CuS nanoflowers-Au (CuS NFs-Au), for the detection of aflatoxin B1 (AFB1) in maize. We synthesized the immunoprobe G8-DIG@CuS NFs-Au, stimulated the in situ development of Au nanoparticles (Au NPs) on Cu NFs by electrical displacement, and obtained Cu NFs-Au for fixing the G8-DIG. G8-DIG@CuS NFs-Au probe-based LFIAs may, in ideal circumstances, use a strip chromatography reader to accomplish sensitive quantitative detection and qualitative visualization. AFB1 has a detection range of 2.82-89.56 µg/L and a detection limit of 0.87 µg/L. When compared with an LFIA based on CuS NFs, this sensitivity is increased by 2.76 times. The practical application of this method in corn flour demonstrated a recovery rate of 81.7% to 117%. Therefore, CuS NFs-Au show great potential for detecting analytes.

15.
Talanta ; 277: 126332, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38823322

RESUMEN

Cardiac troponin I (cTnI) is a critical biomarker for the diagnosis of acute myocardial infarction (AMI). Herein, we report a novel integrated lateral flow immunoassay (LFIA) platform for highly sensitive point-of-care testing (POCT) of cTnI using hierarchical dendritic copper-nickel (HD-nanoCu-Ni) nanostructures. The electrodeposited HD-nanoCu-Ni film (∼22 µm thick) on an ITO-coated glass substrate exhibits superior capillary action and structural integrity. These properties enable efficient sample transport and antibody immobilization, making it a compelling alternative to conventional multi-component paper-based LFIA test strips, which are often plagued by structural fragility and susceptibility to moisture damage. The biofunctionalized HD-nanoCu-Ni substrates were laser-etched with lateral flow channels, including a sample loading/conjugate release zone, a test zone, and a control zone. Numerical simulations were used to further optimize the design of these channels to achieve optimal fluid flow and target capture. The HD-nanoCu-Ni LFIA device utilizes a fluorescence quenching based sandwich immunoassay format using antibody-labeled gold nanoparticles (AuNPs) as quenchers. Two different fluorescent materials, fluorescein isothiocyanate (FITC) and CdSe@ZnS quantum dots (QDs), were used as background fluorophores in the device. Upon the formation of a sandwich immunocomplex with cTnI on the HD-nanoCu-Ni device, introduced AuNPs led to the fluorescence quenching of the background fluorophores. The total assay time was approximately 15 min, demonstrating the rapid and efficient nature of the HD-nanoCu-Ni LFIA platform. For FITC, both inner filter effect (IFE) and fluorescence resonance energy transfer (FRET) contributed to the AuNP-mediated quenching. In the case of CdSe@ZnS QDs, IFE dominated the AuNP-induced quenching. Calibration curves were established based on the relationship between the fluorescence quenching intensity and cTnI concentration in human serum samples, ranging from 0.5 to 128 ng/mL. The limits of detection (LODs) were determined to be 0.27 ng/mL and 0.40 ng/mL for FITC and CdSe@ZnS QDs, respectively. A method comparison study using Passing-Bablok regression analysis on varying cTnI concentrations in human serum samples confirmed the equivalence of the HD-nanoCu-Ni LFIA platform to a commercial fluorescence cTnI LFIA assay kit, with no significant systematic or proportional bias observed.


Asunto(s)
Cobre , Nanoestructuras , Níquel , Troponina I , Troponina I/análisis , Troponina I/sangre , Troponina I/inmunología , Inmunoensayo/métodos , Humanos , Cobre/química , Níquel/química , Nanoestructuras/química , Límite de Detección , Puntos Cuánticos/química , Oro/química , Nanopartículas del Metal/química , Anticuerpos Inmovilizados/inmunología , Anticuerpos Inmovilizados/química
16.
Talanta ; 277: 126438, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38897012

RESUMEN

The escalating issue of drug abuse poses a significant threat to public health and societal stability worldwide. An on-site drug detection platform is vital for combating drug abuse and trafficking, as it eliminates the need for additional tools, extensive processes, or specialized training. Therefore, it is imperative to develop a fast, sensitive, non-invasive, and reliable multiplex drug testing platform. In this study, we have presented a silica core@dual quantum dot-shell nanocomposite (SI/DQD)-based fluorescent lateral flow immunoassay (LFIA) platform for the highly sensitive and simultaneous point-of-care (POC) detection of methamphetamine (MET) and tramadol (TR). A 3D-printed attachment was designed to integrate optical and electrical components, facilitating the miniaturization of the instrument and reducing both cost and complexity. The device's advanced hardware and effective fluorescence extraction algorithm with waveform reconstruction enable swift, automatic noise reduction and data analysis. SI/DQD nanocomposites were utilized as fluorescent nanotags in the LFIA strips due to their outstanding luminous efficiency and robustness. This LFIA platform achieves impressive detection limits (LODs) of 0.11 ng mL-1 for MET and 0.017 ng mL-1 for TR. The method has also successfully detected MET and TR in complex biological samples, demonstrating its practical application capabilities. The proposed fluorescent LFIA platform, based on SI/DQD technology, holds significant promise for the swift and accurate POC detection of these substances. Its affordability, compact size, and excellent analytical performance make it suitable for on-site drug testing, including at borders and roadside checks, and open up new possibilities for the design and implementation of drug testing methods.


Asunto(s)
Límite de Detección , Metanfetamina , Sistemas de Atención de Punto , Puntos Cuánticos , Tramadol , Metanfetamina/análisis , Metanfetamina/inmunología , Tramadol/análisis , Inmunoensayo/métodos , Puntos Cuánticos/química , Humanos , Detección de Abuso de Sustancias/métodos , Dióxido de Silicio/química , Nanocompuestos/química , Fluorescencia
17.
J Virol Methods ; 329: 114991, 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38942174

RESUMEN

The most widely used invitro diagnostic qualitative screening method for dengue virus infection is the lateral flow immunoassay technique. Testing of dengue non-structural antigen NS1 offers specificity in determining the active infection while testing of IgM and IgG helps in differentiating the primary and secondary dengue infections. The ELISA functions as the golden standard for dengue testing and PCR credits for the most accurate determination tool at the genetic level. The RT-PCR endorsed NS1 gene and in ELISA or LFIA NS1 antigen is used as the marker owing to the specificity and lesser chances of mutation effects. This study evaluated the performance of AG-Q Dengue NS1 LFIA kit in comparison with RT-PCR quantification cycle (Cq) Values and ELISA NS1 quantitation. The study also focused on differentiating the samples among dengue serotypes using the RealStar Dengue Type RT-PCR Kit 1.0. Dengue serotype 2 is the prominent viral strain in Kerala region succeeded by serotype 3 and 1 with a prevalence rate of 64 %, 20 % and 6 % respectively. Dengue serotype 4 was not reported during this study period. 10 % co-infection with DENV 1 & DENV 2 was also reported. The AG-Q Dengue NS1 kit stood as efficient in screening by providing positive results with samples having RT-PCR Cq values up to 43 and ELISA NS1 quantification minimum of 14 Panbio units.

18.
Malays J Med Sci ; 31(2): 153-158, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38694586

RESUMEN

Background: The quality of laboratory test results depends on various factors, including sample type selection. Blood samples, such as whole blood, plasma and serum are commonly used for most clinical laboratory examinations. D-dimer parameters are frequently analysed in haematology laboratories and serve as biomarkers for coagulation activation and fibrinolysis. This study aimed to assess the impact of using different sample types on the quality of D-dimer test results. Method: An observational analytical method was used. D-dimer examination was performed using the fluorescent lateral flow immunoassay method. The study sample consisted of 26 participants aged between 18 years old and 22 years old who had no blood disorders. Whole blood and ethylenediaminetetraacetic acid (EDTA) plasma samples were used for the examination of D-dimer levels. Results: D-dimer levels in 26 participants using whole blood samples had a mean value of 0.23 mg/L (230 ng/mL), while plasma samples yielded a mean value of 0.14 mg/L (140 ng/mL). D-dimer levels obtained from whole blood samples were higher than plasma samples but remained within the normal range of 0 mg/L-0.5 mg/L (0 ng/mL-500 ng/mL). Conclusion: The results showed that whole blood samples were more practical than plasma samples. Nevertheless, plasma samples gave results within the normal range of D-dimer values.

19.
Mikrochim Acta ; 191(6): 330, 2024 05 14.
Artículo en Inglés | MEDLINE | ID: mdl-38744738

RESUMEN

In view of a large number of people infected with Helicobacter pylori (H. pylori) with great harm followed, there is an urgent need to develop a non-invasive, easy-to-operate, and rapid detection method, and to identify effective sterilization strategies. In this study, highly specific nanoprobes with nanozyme activity, Ag@Pt nanoparticles (NPs) with the antibody, were utilized as a novel lateral flow immunoassay (LFIA). The optical label (Ag@Pt NPs) was enhanced by the introduction of the chromogenic substrate 3,3',5,5'-tetramethylbenzidine (TMB) and compared with a gold nanoparticles (Au NPs) optical label. Under the optimal condition, Ag@Pt-LFIA and TMB-enhanced Ag@Pt-LFIA for H. pylori were successfully established, two of which were over twofold and 100-fold more sensitive than conventional visual Au NP-based LFIA, respectively. Furthermore, Ag@Pt NPs with the antibody irradiated with NIR laser (808 nm) at a power intensity of 550 mW/cm2 for 5 min exhibited a remarkable antibacterial effect. The nanoprobes could close to bacteria through effective interactions between antibodies and bacteria, thereby benefiting photothermal sterilization. Overall, Ag@Pt NPs provide promising applications in pathogen detection and therapeutic applications.


Asunto(s)
Aleaciones , Helicobacter pylori , Nanopartículas del Metal , Platino (Metal) , Plata , Helicobacter pylori/efectos de la radiación , Helicobacter pylori/efectos de los fármacos , Plata/química , Nanopartículas del Metal/química , Platino (Metal)/química , Aleaciones/química , Antibacterianos/farmacología , Antibacterianos/química , Inmunoensayo/métodos , Bencidinas/química , Oro/química , Humanos , Esterilización/métodos , Límite de Detección
20.
Anal Chim Acta ; 1309: 342646, 2024 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-38772670

RESUMEN

BACKGROUND: Colorimetric lateral flow immunoassay (LFIA) is a widely used point-of-care testing (POCT) technology, while it has entered a bottleneck period because of low detection sensitivity, expensive preparation materials, and incapable quantitative detection. Therefore, it is necessary to develop a novel POCT method that is ultrasensitive, simple, portable, and capable of accurately detecting biomarkers in biofluids daily, particularly for pregnancy preparation and early screening of diseases. RESULT: In this work, a novel dry chemistry-based self-enhanced electrochemiluminescence (DC-SE-ECL) LFIA sensor is introduced for accurate POCT of luteinizing hormone (LH). The proposed DC-SE-ECL immunosensor significantly improves the detection sensitivity through the Poly-l-Lysine (PLL)-based SE-ECL probe and cathode modification of closed bipolar electrode (C-BPE). Additionally, a new type of C-BPE configuration is designed for easily performing the LFIA. And, two standalone absorbent pads are symmetrically arranged below the reporting channel of the electrode pad to decease useless residues on the detection pad, which further improves the detection performance. Under optimized conditions, the proposed LFIA sensor has a low limit of detection (9.274 µIU mL-1) and a wide linear dynamic range (0.01-100 mIU mL-1), together with good selectivity, repeatability and storage stability. SIGNIFICANCE: These results indicate that the proposed DC-SE-ECL method has the potential as a new tool for detecting biomarkers in clinical samples.


Asunto(s)
Técnicas Electroquímicas , Mediciones Luminiscentes , Hormona Luteinizante , Hormona Luteinizante/análisis , Hormona Luteinizante/sangre , Humanos , Inmunoensayo/métodos , Técnicas Electroquímicas/instrumentación , Límite de Detección , Electrodos , Técnicas Biosensibles
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...