Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 720
Filtrar
2.
J Orthop Surg Res ; 19(1): 583, 2024 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-39304891

RESUMEN

OBJECTIVE: Given the recent application of two new types of intramedullary nail devices in the treatment of comminuted femoral intertrochanteric fractures (CFIFs), there is still a lack of deep understanding and comparative evaluation of their biomechanical properties. Therefore, this study aims to systematically compare the advantages and disadvantages of these two new devices with traditional proximal femoral nail antirotation (PFNA) and InterTan nails in the fixation of CFIFs through finite element analysis. METHODS: Based on the validated finite element model, this study constructed an accurate CFIFs model. In this model, PFNA, InterTan nails, proximal femoral bionic nails (PFBN), and new intramedullary systems (NIS) were implanted, totaling four groups of finite element models. Each group of models was subjected to simulation tests under a vertical load of 2100 N to evaluate the displacement and Von Mises stress (VMS) distribution of the femur and intramedullary nail devices. RESULTS: Under a vertical load of 2100 N, a comparative analysis of the four finite element models showed that the NIS device exhibited the most superior performance in terms of peak displacement, while the PFNA device performed relatively poorly. Although the NIS device had the highest peak stress in the femur, it had the smallest peak displacement of both the femur and intramedullary nail devices, and the peak stress was mainly concentrated on the lateral side of the femur, with significantly lower stress in the proximal femur compared to the other three intramedullary nail devices. In contrast, the PFBN device had the lowest peak stress in the femur, and its peak displacement of both the femur and intramedullary nail devices was also less than that of PFNA and InterTan nails. CONCLUSION: This study demonstrates that in the treatment of CFIFs, PFBN and NIS devices exhibit superior biomechanical performance compared to traditional PFNA and InterTan nail devices. Especially the NIS device, which can achieve good biomechanical results when fixing femoral intertrochanteric fractures with missing medial wall. Therefore, both PFBN and NIS devices can be considered reliable closed reduction and internal fixation techniques for the treatment of CFIFs, with potential clinical application value.


Asunto(s)
Clavos Ortopédicos , Análisis de Elementos Finitos , Fijación Intramedular de Fracturas , Fracturas Conminutas , Fracturas de Cadera , Humanos , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/instrumentación , Fenómenos Biomecánicos , Fracturas de Cadera/cirugía , Fracturas Conminutas/cirugía , Fémur/cirugía
3.
Cureus ; 16(8): e66944, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39280531

RESUMEN

(Meth)acrylates are a common cause of allergic contact dermatitis (ACD) that can be found in medical (such as pads) and aesthetic (specifically nail cosmetics) products. Prolonged and intimate contact with sanitary pads can predispose individuals to ACD triggered by a variety of allergens. This report presents the case of a young female patient with episodes of nail contact dermatitis followed by a protracted history of intensely symptomatic allergic contact dermatitis affecting the external genital area, precipitated by methacrylates present in menstrual pads.

4.
Med Eng Phys ; 131: 104230, 2024 09.
Artículo en Inglés | MEDLINE | ID: mdl-39284656

RESUMEN

There is currently no definitive evidence for the implant of choice for the treatment of reverse pertrochanteric fractures. Here, we aimed to compare the stability provided by two implant options: long and short intramedullary nails. We performed finite element simulations of different patterns of reverse pertrochanteric fractures with varying bone quality, and compared the short vs long nail stabilization under physiological loads. For each variable combination, the micromotions at the fracture site, bone strain, and implant stress were computed. Mean micromotions at the fracture surface and absolute and relative fracture surface with micromotions >150 µm were slightly lower with the short nail (8%, 3%, and 3%, respectively). The distal fracture extension negatively affected the stability, with increasing micromotions on the medial side. Bone strain above 1 % was not affected by the nail length. Fatigue stresses were similar for both implants, and no volume was found above the yield and ultimate stress in the tested conditions. This simulation study shows no benefit of long nails for the investigated patterns of reverse pertrochanteric fractures, with similar micromotions at the fracture site, bone strain, and implant stress.


Asunto(s)
Clavos Ortopédicos , Análisis de Elementos Finitos , Fijación Intramedular de Fracturas , Fenómenos Biomecánicos , Humanos , Fijación Intramedular de Fracturas/instrumentación , Estrés Mecánico , Fracturas de Cadera/cirugía , Fracturas de Cadera/fisiopatología , Fenómenos Mecánicos
6.
BMC Musculoskelet Disord ; 25(1): 697, 2024 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-39223520

RESUMEN

OBJECTIVE: There is currently a lack of in-depth comparative evaluation regarding the biomechanical properties of novel intramedullary nail devices in the treatment of basal femoral neck fractures (BFNF). This study aims to utilize finite element analysis to compare the performance differences of two novel devices with traditional PFNA and InterTan nails in the fixation of BFNF. METHODS: Based on a validated finite element model, this study constructed an accurate BFNF model and implanted four different intramedullary nail devices: PFNA, InterTan nail, PFBN (proximal femoral biomimetic nail), and NIS (novel intramedullary system). Under a vertical load of 2100N, the displacement and Von Mises stress (VMS) distribution of each group of models were evaluated through simulation testing. RESULTS: Under a load of 2100N, the PFBN device exhibited the best performance in terms of displacement and peak stress, while PFNA performed poorly. The peak displacement of the NIS device was lower than that of PFNA and InterTan nails, while the peak stress of the InterTan nail was lower than that of PFNA and NIS. CONCLUSION: The PFBN device demonstrates stronger load-bearing and shear-resistant properties in the treatment of BFNF, and the NIS device also shows significant improvement in stability. Therefore, both the PFBN and NIS devices are reliable internal fixation techniques for the treatment of CFIFs, with potential clinical application prospects.


Asunto(s)
Clavos Ortopédicos , Fracturas del Cuello Femoral , Análisis de Elementos Finitos , Fijación Intramedular de Fracturas , Humanos , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/métodos , Fracturas del Cuello Femoral/cirugía , Fracturas del Cuello Femoral/fisiopatología , Fenómenos Biomecánicos/fisiología , Estrés Mecánico , Soporte de Peso
7.
Pediatr Dermatol ; 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39225247

RESUMEN

Telomere biology disorders (TBD) are a complex set of inherited illnesses characterized by short telomeres. Dyskeratosis congenita (DC), which is now considered a severe TBD phenotype, is characterized by reticulated pigmentary changes, nail dystrophy, premalignant oral leukoplakia, and systemic involvement. This case describes a 2-year-old female with reticulated pigmentary changes and Terry's nails who was found to have a TERT variant and short telomeres; she lacked other mucocutaneous and systemic features of TBD. This report describes a unique clinical presentation of TBD and highlights the importance of upholding suspicion for TBD in individuals with limited or subtle features of classic DC.

8.
Support Care Cancer ; 32(9): 577, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-39112734

RESUMEN

IMPORTANCE: Patients undergoing cancer treatment experience a multitude of skin, hair, and nail adverse events, prompting them to use non-evidence-based and often restrictive over-the-counter (OTC) recommendations to alleviate their symptoms. Comprehensively assessing evidence-based OTC modalities is crucial to enable cancer patients to comfortably resume their lives post-treatment and integrate clinically sound practices into their self-care routines. OBJECTIVE: Perform a systematic review and assessment of evidence-based OTC skin, hair, and nail care recommendations for adult patients undergoing cancer treatment. EVIDENCE REVIEW: PubMed, Cochrane, Embase, and Medline databases were searched in March 2023 to identify English articles addressing OTC skin, hair, and nail care recommendations for adult patients before, during, and after cancer chemotherapy or radiation therapy (RT). Quality was assessed with Oxford Centre for Evidence Based Medicine criteria. FINDINGS: 2192 unique articles were screened, of which 77 met inclusion criteria consisting of 54 randomized controlled trials (RCT), 8 non-randomized controlled cohorts, 1 non-randomized controlled clinical trial, 3 controlled prospective cohorts, 4 prospective cohorts, 2 controlled clinical trials, 1 prospective comparative study, 2 case reports, and 2 case series discussing 9322 patients. An additional article outside of our database search was included for a total of 78 articles. OTC skin care treatments with the best quality of evidence included moisturizing creams. Our review revealed a paucity of evidence-based hair and nail care practices. CONCLUSIONS AND RELEVANCE: This systematic review serves to highlight the efficacy of diverse OTC skin, hair, and nail care recommendations for adult cancer patients while encouraging further clinical trials to establish evidence-based management guidelines.


Asunto(s)
Enfermedades de la Uña , Neoplasias , Medicamentos sin Prescripción , Humanos , Neoplasias/terapia , Neoplasias/radioterapia , Medicamentos sin Prescripción/administración & dosificación , Medicamentos sin Prescripción/uso terapéutico , Adulto , Enfermedades de la Uña/terapia , Cuidados de la Piel/métodos , Enfermedades de la Piel/terapia
11.
Front Med (Lausanne) ; 11: 1444434, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39131089

RESUMEN

Background: To explore the clinical efficacy and safety of Kirschner wires (KWs) as a blocking screw technique for extra-articular fractures of the distal tibia treated with intramedullary nails (IMNs). Methods: Fifty-three patients were treated with KW-assisted IMN for extra-articular fractures of the distal tibia via the blocking screw technique or Poller screw (PS) technique. The operation time, number of fluoroscopies, number of blocking screws used, blood loss and time to union were compared between the two groups. Additionally, the functional outcomes of the two groups were compared using range of motion (ROM), visual analog scale (VAS), American Orthopedic Foot and Ankle Society (AOFAS), and Lysholm scores. Results: Compared with those in the PS group, the operation time in the KW group was significantly shorter, and the number of fluoroscopy procedures and amount of blood loss during KW surgery were also significantly lower (p = 0.014, 0.001, and 0.036, respectively). Regarding the functional outcomes, there were no significant differences in the ROM, VAS score, AOFAS score or Lysholm score between the two groups (p > 0.05). Conclusion: In the treatment of extra-articular fractures of the distal tibia with nails, the use of KW as a blocking screw technique is safe and reliable.

12.
J Orthop Surg Res ; 19(1): 481, 2024 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-39152451

RESUMEN

BACKGROUND: Distal tibial fractures represent common lower limb injuries, frequently accompanied by significant soft tissue damage. The optimal surgical approach for managing these fractures remains a topic of considerable debate. The aim of this study was to perform a comparative analysis of the outcomes associated with retrograde intramedullary tibial nails (RTN) and minimally invasive plate osteosynthesis (MIPO) in the context of treating extra-articular distal tibial fractures. METHODS: A retrospective review was conducted on a cohort of 48 patients who sustained extra-articular distal tibial fractures between December 2019 and December 2021. Patients underwent either RTN or MIPO procedures. Various parameters, including operative duration, intraoperative fluoroscopy exposure, time to union, duration until full weight-bearing, American Orthopedic Foot and Ankle Society (AOFAS) scores, and complications, were recorded and compared between the two treatment groups. RESULTS: No statistically significant differences were observed in operative duration, time to union, angulation of the distal tibial coronal plane, or AOFAS scores between the RTN and MIPO groups. However, the RTN group had a higher average number of intraoperative fluoroscopy images (8.2 ± 2.3) compared to the MIPO group (4.1 ± 2.0). The RTN group demonstrated shorter average hospital stays (7.1 ± 1.4 days) and a quicker return to full weight-bearing (9.9 ± 1.3 weeks), which were significantly superior to the MIPO group (9.0 ± 2.0 days and 11.5 ± 1.5 weeks, respectively). In terms of complications, the RTN group had one case of superficial infection, whereas the MIPO group exhibited two cases of delayed union and nonunion, two occurrences of deep infection, and an additional three cases of superficial infection. CONCLUSIONS: Both RTN and MIPO are effective treatment options for extra-articular distal tibial fractures. However, RTN may offer superior outcomes in terms of decreased inpatient needs, faster return to full weight-bearing capacity, and a lower rate of complications.


Asunto(s)
Clavos Ortopédicos , Placas Óseas , Fijación Intramedular de Fracturas , Procedimientos Quirúrgicos Mínimamente Invasivos , Fracturas de la Tibia , Humanos , Estudios Retrospectivos , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/diagnóstico por imagen , Masculino , Femenino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Adulto , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/instrumentación , Resultado del Tratamiento , Tempo Operativo , Anciano , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Soporte de Peso , Fluoroscopía
13.
J Child Orthop ; 18(4): 349-359, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39100980

RESUMEN

The last years brought many advances relevant to lower limb reconstruction. It feels like guided growth has been looked at from every angle, and still there are new emerging concepts like rotational guided growth waiting to be validated. New hexapod external devices are more accurate and easier to use, and new unilateral fixators allow for more versatile and stable fixation and lengthening. Intramedullary nail lengthening has found its place as a standard procedure for various diagnoses in children and young adults. First results of new and exciting approaches like extramedullary implantable nail lengthening and lengthening plates have been reported. Pharmaceutical treatment has changed the course of certain diseases and must be integrated and considered when making a reconstructive treatment plan. As reconstructive surgery is rapidly advancing so are the technical options for prosthetic fitting, which makes it difficult for caregivers as well as for parents to make the decision between reconstruction and amputation surgery for the most severe cases of congenital deficiencies. This review is highlighting new developments of lower limb reconstruction and is reviewing the current literature.

14.
J Child Orthop ; 18(4): 421-431, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39100985

RESUMEN

Purpose: Fractures occurring at the metaphyseal-diaphyseal junction of the distal humerus in children are not commonly documented in the literature. Until this moment, there is no gold standard technique regarding its management and most surgeons treat it as a regular supracondylar humerus fracture by conventional pinning. This systematic review explores the relevant literature to assess the efficacy of different techniques. Methods: This review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Our literature search encompassed several online databases, including PUBMED/MEDLINE, Scopus, Web of Science Core Collection, and Google Scholar. Data from articles that met our general inclusion criteria were extracted and categorized into treatment method groupings. Functional and cosmetic outcomes, demographic characteristics, and complications were the main parameters used to analyze the data. Results: Ten retrospective studies met our inclusion criteria with a total of 178 participants of unilateral pediatric distal humerus metaphyseal-diaphyseal junction fractures. Most literature chose closed reduction and percutaneous pinning in seven articles, followed by elastic stable intramedullary nail technique used in three articles, then conservative treatment was chosen in two articles, while only one article used lateral miniplate and assisted K-wire and another article used combined closed reduction and percutaneous pinning and intramedullary K-wire. As regards the operation time; elastic stable intramedullary nails had the shortest time with a mean of 39.7 min (range: 37.5-41.9 min), while closed reduction and percutaneous pinning had the longest time with a mean of 75.47 min (range: 55.9-92.1 min). The shortest healing time was observed in miniplate with a mean of 7.2 weeks, while the most prolonged was in conservative management with a mean of 12 weeks and closed reduction and percutaneous pinning was a mean of 10 weeks. Regarding Flynn's criteria, all participants received excellent and good except in closed reduction and percutaneous pinning; 13 cases were fair and 2 cases were poor. Regarding complications, the most commonly observed complication after metaphyseal-diaphyseal junction fracture was cubitus varus, the highest incidence was in conservative management (33% of cases), followed by closed reduction and percutaneous pinning (10.9% of cases), the least incidence was observed in elastic stable intramedullary nails (3.77% of cases), and none of the cases treated with mini plate developed this complication. Other complications were observed only with closed reduction and percutaneous pinning; 8.5% of cases developed fixation loss, 6.2% of cases had a significantly reduced range of motion, and one case refractured. Conclusion: Pediatric distal humerus metaphyseal-diaphyseal junction fractures should be distinguished from the more prevalent supracondylar humerus fractures, as conventional pinning techniques are associated with a higher incidence of complications and increased both operative and healing times.Level of evidence: III.

15.
3D Print Med ; 10(1): 28, 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39110149

RESUMEN

INTRODUCTION: Distal locking is a challenging and time-consuming step in interlocked intramedullary nailing of long bone fractures. Current methods have limitations in terms of simplicity, universality, accuracy, speed, and safety. We propose a novel device and software for distal locking using computer vision. METHODS AND MATERIALS: The device consists of an universal ancillary clamp, a telescopic arm, a viewfinder clamp, and a radio-opaque cross. The software uses a camera photo from the C-arm intensifier and adjusts for geometric projection deformities. The software employs edge detection, Hough transform, perspective interpolation, and vector calculation algorithms to locate the distal hole center. The device and software were designed, manufactured, and tested using 3D CAD, FEM, DRR, and performance testing on phantom bones. RESULTS: The device and software showed high accuracy and precision of 98.7% and 99.2% respectively in locating the distal hole center and calculating the correctional vector. The device and software also showed high success ratio in drilling the hole and inserting the screw. The device and software reduced the radiation exposure for the surgeon and the patient. The success ratio of the device and software was validated by the physical testing, which simulated the real clinical scenario of distal locking. The radiation exposure was as low as 5 s with a radiation dose of 0.2mSv, drastically reducing radiation exposure during distal locking. DISCUSSION: Our device and software have several advantages over other distal locking methods, such as simplicity, universality, accuracy, speed, and safety. Our device and software also have some disadvantages, such as reliability and legislation. Our device and software can be compared with other distal locking methods based on these criteria. Our device and software have some limitations and challenges that need to be addressed in the future, such as clinical validation, and regulatory approval. CONCLUSION: The device showed promising results in terms of low-cost, reusability, low radiation exposure, high accuracy, fast distal locking, high stiffness, and adaptability. The device has several advantages over other distal locking techniques, such as free-hand technique, mechanical aiming devices, electromagnetic navigation systems, and computer-assisted systems. We believe that our device and software have the potential to revolutionize the distal locking technique and to improve the outcomes and quality of life of the patients with long bone fractures.

16.
Contact Dermatitis ; 2024 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-39180387

RESUMEN

BACKGROUND: 2-Hydroxyethyl methacrylate (HEMA) was added into the European baseline series (EBS) in 2019. There is limited data regarding the frequency, relevance, and sources of exposure to HEMA. OBJECTIVES: To investigate the frequency and clinical relevance of positive reactions to HEMA in the EBS in Israel, and explore sources of exposure. METHODS: Retrospective cohort study that included all patients who underwent patch testing with the EBS in a tertiary center in Israel between 2020 and 2023. Positive reactions to HEMA were stratified by sex, six age groups, and year of study. Sources of exposure to HEMA as well as occupational data were recorded. RESULTS: A total of 1671 consecutive patients underwent HEMA patch testing, with 135 (8.1%) showing positive reactions to HEMA (130 females, 5 males). The prevalence in women (11.0%) was significantly higher compared to men (1.0%) (p < 0.001). Stratification by age and sex revealed the highest frequency of HEMA sensitivity of 16.7% among women younger than 30 years of age, with odds ratio of 2.3 (95%CI: 1.6-3.3, p < 0.001) compared to older women. There was an increase in frequency among women between the years 2022 and 2023 when compared to 2020-2021 (OR 1.7, 95%CI: 1.5-2.1, p < 0.01) attributable to COVID-19 pandemic and social restrictions. Among men the frequency fluctuations over the study period and age categories were nonsignificant. 111 (84%) were judged to be of clinical relevance and nail cosmetics was responsible for 95% of them. Of 111 patients with relevant reaction (110 females, 1 males), 20 (18%) had occupational contact dermatitis (18 nails stylists, 2 dentists). Other culprit products included sanitary pads (n = 4), medical adhesives (n = 3), and paints (n = 2). CONCLUSION: We report the highest frequency of HEMA sensitivity to date of 8.1%, that was most common among young women and in vast majority of cases was attributable to nail cosmetics. Our findings reflect the popularity of nail cosmetics in Israel as well as the global trend of increasing sensitivity to (meth)acrylates.

17.
Rev Bras Ortop (Sao Paulo) ; 59(Suppl 1): e39-e42, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39027177

RESUMEN

Total knee arthroplasty (TKA) is one of the most effective operations to relieve pain and improve function in the end stage of osteoarthritis (when bone on bone contact occurs). The intraoperative complications of TKA include fracture, tendon or ligament injury, and nerve or vascular complications. We herein describe an unusual complication of intramedullary pin migration within the femoral canal during TKA. A 72-year-old male patient underwent TKA with a posterior stabilization system with sacrifice of the posterior cruciate ligament. The distal femur was sectioned and balance was checked in extension. Then to make anterior, posterior, chamfer and notch cuts, the five-in-one anteroposterior (AP) cutting block was placed on the distal femur and the cuts were initiated. As there was a medial overhang of the cutting block, it was shifted laterally. While doing so, the pins had to be shifted too, and one of them was inadvertently hammered into the previously-created medullary canal opening of the femur. As usual orthopedic instruments, like the long straight artery forceps and pituitary rongeurs, failed to remove the migrated pin, an extralong laparoscopic grasper was used under fluoroscopy control to locate, grasp, and remove the migrated pin.

18.
Drug Test Anal ; 2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-38992954

RESUMEN

In a doping case, a top athlete challenged an anti-doping rule violation, involving molidustat. Molidustat is a stabilizing agent of the hypoxia-inducible factor (HIF) recently developed. It is currently undergoing clinical trials for anemia associated with chronic kidney disease. HIF stabilizers are banned at all times by the World Anti-Doping Agency (class S2). Because of their pharmacological proprieties, these new drugs can enhance athletic performance. The athlete's defense wanted to analyze multiple keratinized matrices as they allow long-term investigations. Requests concerning HIF stabilizers are constantly growing. We have therefore developed a liquid chromatography coupled with tandem mass spectrometry method to identify and quantify three molecules of this class: molidustat, vadadustat, and roxadustat. Thirty milligrams of keratinized matrices were incubated in 1 mL of pH 8.4 diammonium hydrogen phosphate buffer for 16 h at 40°C with 1 ng of testosterone-D3, used as internal standard. After extraction with ethyl acetate/diethyl ether (80/20), the organic phase was evaporated, and the dry residue was reconstituted in 30 µL of initial phase. The method was linear from 5 to 1000 pg/mg for the three analytes. Limits of quantification were 2, 0.5, and 5 pg/mg for molidustat, roxadustat, and vadadustat, respectively. The analysis of the athlete's head hair (collected 1 month after the urine test) showed a concentration of molidustat of 135 pg/mg, and his beard hair and his fingernails clippings contained 55 and 40 pg/mg, respectively.

19.
BMC Musculoskelet Disord ; 25(1): 531, 2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-38987691

RESUMEN

BACKGROUND: The treatment of the displaced proximal humerus fractures (PHF) still facing a lot of unsolved problems. The aim of this study was to evaluate the clinical effect of MultiLoc nails for the treatment of PHF and present outcomes of patients with different Neer's classification and reduction quality. METHODS: Adult patients with PHFs were recruited and treated with MultiLoc nail. Intraoperative data, radiographic and functional outcomes, as well as occurrence of postoperative complications were assessed. RESULTS: 48 patients met inclusion and exclusion criteria and were included in this study. The DASH Score were 32.2 ± 3.1 points at 12 months, and 37.3 ± 2.5 points at the final follow-up. The mean ASES score at 12 months and final follow-up were 74.4 ± 6.2 and 78.8 ± 5.1, respectively. The mean CM Score in all 48 patients reached 68 ± 6.4 points at the final follow-up, relative side related CM Score 75.2 ± 7.7% of contralateral extremity. The incidence rate of complications was 20.8%. Patients with fracture mal-union, adhesive capsulitis were observed but no secondary surgeries were performed. There was no significantly difference of DASH Score 12 months after surgery and at the last follow-up among patients with different Neer's classification or reduction quality. However, functional outcomes such as ASES score and CM score were significantly influenced by severity of fracture and the quality of fracture reduction. CONCLUSIONS: Our study demonstrated that MultiLoc nails is well suited for proximal humeral fractures, with satisfactory health status recovery, good radiographic results, positive clinical outcomes and low rates of complications. The treatment for four part PHF still faces great challenges. Accurate fracture reduction was an important factor for good functional result.


Asunto(s)
Clavos Ortopédicos , Fijación Intramedular de Fracturas , Complicaciones Posoperatorias , Fracturas del Hombro , Humanos , Fracturas del Hombro/cirugía , Fracturas del Hombro/diagnóstico por imagen , Masculino , Femenino , Persona de Mediana Edad , Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/efectos adversos , Anciano , Resultado del Tratamiento , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/epidemiología , Adulto , Estado de Salud , Estudios de Seguimiento , Radiografía , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...