Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
J Orthop Surg Res ; 19(1): 526, 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39215301

RESUMEN

INTRODUCTION: Primary total elbow replacement (TER) services in England are being restructured with the goal of centralising care to specialised centres. It is important to monitor the impact of this service redesign. This protocol outlines an intended analysis to provide detailed descriptions of the patients who are receiving primary TER, where and by whom TER is being performed, and what the current surgical practices for TER are in England before the reconfiguration. METHODS: This analysis will use the National Joint Registry (NJR) elbow dataset and link it with NHS England Hospital Episode Statistics-Admitted Patient Care (HES-APC). It will include eligible patients from the start of the NJR elbow dataset in April 2012 to December 2022. The main objective is to determine the incidence of TER in England. Age-sex standardised rates will be calculated for groups including different ethnicities, and socioeconomic backgrounds, using the mid-year population data provided by the Office for National Statistics. This planned analysis will summarise patient characteristics such as age, sex, body mass index (BMI), hand dominance, American Society of Anaesthesiologists (ASA) grade, indication for TER, socioeconomic status, and patient co-morbidities. It will also examine implant fixation type, classification, brand/type, and changes over time in implant types used in England. Additionally, it will explore the characteristics and volume of the surgeons and hospitals providing primary TER services, including the grade of the primary surgeons, funding source for surgery, and admission type. The analysis will cover the number of procedures performed by surgeons and hospitals annually in England and in each region of England. Finally, the planned analysis will summarise the elective wait time, postoperative length of stay, and any serious adverse events or re-admissions within 30 and 90 days after the TER. DISCUSSION: This protocol describes the first deep dive analysis into the NJR elbow dataset to describe the incidence of TER surgery in England and the characteristics of patients who are receiving it. This analysis will summarise current primary TER practices in England before service reconfigurations. The impact of reconfiguration can be monitored by comparing future practice to the outcomes from this study. Trial registration ClinicalTrials.gov, NCT06355011. Registered 02 April 2024, https://clinicaltrials.gov/ct2/show/NCT06355011 .


Asunto(s)
Artroplastia de Reemplazo de Codo , Sistema de Registros , Humanos , Inglaterra , Artroplastia de Reemplazo de Codo/estadística & datos numéricos , Femenino , Masculino , Persona de Mediana Edad , Anciano
2.
J Orthop Case Rep ; 14(7): 179-184, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39035391

RESUMEN

Introduction: The purpose of this study is to analyze the trend of unicompartmental knee replacement (UKR) in India, based on the data obtained from the Indian joint registry, in comparison with the global trends. Materials and Methods: This study is a retrospective analysis of data from an Indian joint registry for cases performed between 2016 and 2021. A total of 1086 UKRs were identified and the following information was analyzed: demographic data, diagnosis leading to primary UKR, yearwise surgeon inclination toward UKR, implant preference, regions where UKR was preferred, and the effect of robotics in UKR. UKR registry data were compared with the registry data from the UK (NJR), Sweden (SKAR), Australia (AOJR), and the USA (AJRR). Results: One thousand eighty-six UKRs were included in the study: The vast majority of them (97%) were implanted due to primary osteoarthritis followed by deformity (2%), as in accordance with other registries. Since 2016, though very minimal, there has been a gradual increase in the numbers and the percentage of cases contributed by UKR, of all knee replacements with the maximum of 2.85% reported in 2019. The same has been observed in the global trends as well. Oxford knees (60%) are the most preferred implants followed by journey uni knee (20%) in India. The cities where more unicompartmental knee are performed are in the order of Mumbai (32.78%), Faridabad (9.39%), Pune (7.92%), and Hyderabad (6.35%). Surgeon preference for robotic assisted UKR is increasing, accounting for 34% of UKR in 2020, which is in coherence with AOJR. Conclusion: The percentage of knee replacements contributed by UKR is increasing globally and the same trend can be observed in India. Oxford phase III prosthesis are the most preferred UKR prosthesis. UKRs are mostly performed in selected pockets of India, with Mumbai almost contributing to one-third of all the cases. The use of robotics in UKR is increasing and is expected to give better results in the future.

3.
J Orthop ; 56: 32-39, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38784946

RESUMEN

Background: There is an accepted variation in the financial cost of total knee arthroplasty (TKA) implants but it is not known whether this cost is reflected by the evidence in support of their use. A cost analysis study was carried out to determine the total cost of consumables of a TKA, and whether this was related to the supporting evidence and survivorship data. Methods: Intra-operative data for all unilateral, cemented, primary TKA over a 13 month period at a high-volume Orthopaedic Centre was collected. Level of evidence for each model was taken from the Orthopaedic Data Evaluation Panel (ODEP) website, and data from the UK National Joint Registry was used to assign survivorship (failure rates). Correlation was calculated using the Spearman rank correlation (r). Results: A total of 1301 TKA were performed at the study centre during the data collection period. The mean cost of consumables for a TKA with patella resurfacing (n = 816) was £1969.08 (range of £1061.46 and £5143.89), and without resurfacing (n = 485) was £1846.62 (range of £1118.98 and £4196.81). There was a negative correlation between price of implant and ODEP rating (r = -0.47), with increasing level of evidence being associated with a lower cost. There was a positive correlation between price of implant and rate of implant failure at the1-, 3- and 5-year time-points (r = 0.55, 0.44, 0.28 respectively), with increasing cost being associated with a higher failure rate. Conclusion: Higher financial cost of TKA prostheses was associated with a weaker level of supporting evidence and a higher failure rate. The increased financial cost of new implants may be justified as more data and evidence becomes available to support an advantage in its use over currently established implants.

4.
Bone Joint J ; 105-B(1): 47-55, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36587261

RESUMEN

AIMS: The aim of this study was to identify variables associated with time to revision, demographic details associated with revision indication, and type of prosthesis employed, and to describe the survival of hinge knee arthroplasty (HKA) when used for first-time knee revision surgery and factors that were associated with re-revision. METHODS: Patient demographic details, BMI, American Society of Anesthesiologists (ASA) grade, indication for revision, surgical approach, surgeon grade, implant type (fixed and rotating), time of revision from primary implantation, and re-revision if undertaken were obtained from the National Joint Registry data for England, Wales, Northern Ireland, and the Isle of Man over an 18-year period (2003 to 2021). RESULTS: There were 3,855 patient episodes analyzed with a median age of 73 years (interquartile range (IQR) 66 to 80), and the majority were female (n = 2,480, 64.3%). The median time to revision from primary knee arthroplasty was 1,219 days (IQR 579 to 2,422). Younger age (p < 0.001), decreasing ASA grade (p < 0.001), and indications for revision of sepsis (p < 0.001), unexplained pain (p < 0.001), non-polyethylene wear (p < 0.001), and malalignment (p < 0.001) were all associated with an earlier time to revision from primary implantation. The median follow-up was 4.56 years (range 0.00 to 17.52), during which there were 410 re-revisions. The overall unadjusted probability of re-revision for all revision HKAs at one, five, and ten years after surgery were 2.7% (95% confidence interval (CI) 2.2 to 3.3), 10.7% (95% CI 9.6 to 11.9), and 16.2% (95% CI 14.5 to 17.9), respectively. Male sex (p < 0.001), younger age (p < 0.001), revision for septic indications (p < 0.001) or implant fracture (p = 0.010), a fixed hinge (p < 0.001), or surgery performed by a non-consultant grade (p = 0.023) were independently associated with an increased risk of re-revision. CONCLUSION: There were several factors associated with time to first revision. The re-revision rate was 16.2% at ten years; however, the risk factors associated with an increased risk of re-revision could be used to counsel patients regarding their outcome.Cite this article: Bone Joint J 2023;105-B(1):47-55.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Masculino , Femenino , Anciano , Artroplastia de Reemplazo de Rodilla/efectos adversos , Diseño de Prótesis , Prótesis de la Rodilla/efectos adversos , Factores de Riesgo , Reoperación , Sistema de Registros , Falla de Prótesis
5.
Bone Joint J ; 104-B(11): 1193-1195, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36317347

RESUMEN

Periprosthetic joint infection (PJI) remains an extremely challenging complication. We have focused on this issue more over the last decade than previously, but there are still many unanswered questions. We now have a workable definition that everyone should align to, but we need to continue to focus on identifying the organisms involved. Surgical strategies are evolving and care is becoming more patient-centred. There are some good studies under way. There are, however, still numerous problems to resolve, and the challenge of PJI remains a major one for the orthopaedic community. This annotation provides some up-to-date thoughts about where we are, and the way forward. There is still scope for plenty of research in this area.Cite this article: Bone Joint J 2022;104-B(11):1193-1195.


Asunto(s)
Artritis Infecciosa , Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Infecciones Relacionadas con Prótesis , Humanos , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/terapia , Líquido Sinovial , Biomarcadores , Sensibilidad y Especificidad
6.
Bone Joint Res ; 11(10): 690-699, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36177603

RESUMEN

AIMS: We compared the risks of re-revision and mortality between two-stage revision surgery and single-stage revision surgery among patients with infected primary knee arthroplasty. METHODS: Patients with a periprosthetic joint infection (PJI) of their primary knee arthroplasty, initially revised with a single-stage or a two-stage procedure in England and Wales between 2003 and 2014, were identified from the National Joint Registry. We used Poisson regression with restricted cubic splines to compute hazard ratios (HR) at different postoperative periods. The total number of revisions and re-revisions undergone by patients was compared between the two strategies. RESULTS: A total of 489 primary knee arthroplasties were revised with single-stage procedure (1,390 person-years) and 2,377 with two-stage procedure (8,349 person-years). The adjusted incidence rates of all-cause re-revision and for infection were comparable between these strategies (HR overall five years, 1.15 (95% confidence interval (CI) 0.87 to 1.52), p = 0.308; HR overall five years, 0.99 (95% CI 0.70 to 1.39), p = 0.949, respectively). Patients initially managed with single-stage revision received fewer revision procedures overall than after two-stage revision (1.2 vs 2.2, p < 0.001). Mortality was lower for single-stage revision between six and 18 months postoperative (HR at six months, 0.51 (95% CI 0.25 to 1.00), p = 0.049 HR at 18 months, 0.33 (95% CI 0.12 to 0.99), p = 0.048) and comparable at other timepoints. CONCLUSION: The risk of re-revision was similar between single- and two-stage revision for infected primary knee arthroplasty. Single-stage group required fewer revisions overall, with lower or comparable mortality at specific postoperative periods. The single-stage revision is a safe and effective strategy to treat infected knee arthroplasties. There is potential for increased use to reduce the burden of knee PJI for patients, and for the healthcare system.Cite this article: Bone Joint Res 2022;11(10):690-699.

7.
Bone Jt Open ; 3(9): 716-725, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36106695

RESUMEN

Data of high quality are critical for the meaningful interpretation of registry information. The National Joint Registry (NJR) was established in 2002 as the result of an unexpectedly high failure rate of a cemented total hip arthroplasty. The NJR began data collection in 2003. In this study we report on the outcomes following the establishment of a formal data quality (DQ) audit process within the NJR, within which each patient episode entry is validated against the hospital unit's Patient Administration System and vice-versa. This process enables bidirectional validation of every NJR entry and retrospective correction of any errors in the dataset. In 2014/15 baseline average compliance was 92.6% and this increased year-on-year with repeated audit cycles to 96.0% in 2018/19, with 76.4% of units achieving > 95% compliance. Following the closure of the audit cycle, an overall compliance rate of 97.9% was achieved for the 2018/19 period. An automated system was initiated in 2018 to reduce administrative burden and to integrate the DQ process into standard workflows. Our processes and quality improvement results demonstrate that DQ may be implemented successfully at national level, while minimizing the burden on hospitals.Cite this article: Bone Jt Open 2022;3(9):716-725.

8.
Bone Joint J ; 104-B(9): 1052-1059, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36047019

RESUMEN

AIMS: Our main aim was to describe the trend in the comorbidities of patients undergoing elective total hip arthroplasties (THAs) and knee arthroplasties (KAs) between 1 January 2005 and 31 December 2018 in England. METHODS: We combined data from the National Joint Registry (NJR) on primary elective hip and knee arthroplasties performed between 2005 and 2018 with pre-existing conditions recorded at the time of their primary operation from Hospital Episodes Statistics. We described the temporal trend in the number of comorbidities identified using the Charlson Comorbidity Index, and how this varied by age, sex, American Society of Anesthesiologists (ASA) grade, index of multiple deprivation, and type of KA. RESULTS: We included 696,504 and 833,745 elective primary THAs and KAs respectively, performed for any indication. Between 2005 and 2018, the proportion of elective THA and KA patients with one or more comorbidity at the time of their operation increased substantially (THA: 20% to 38%, KA: 22% to 41%). This was driven by increases in four conditions: chronic obstructive pulmonary disease (COPD) (2018: ~17%), diabetes without complications (2018: THA 10%, KA 14%), myocardial infarction (2018: 4%), and renal disease (2018: ~8%). Notably, renal disease prevalence increased from < 1% in 2005 to ~8% in 2018. CONCLUSION: Between 2005 and 2018 there were significant changes in the number of comorbidities recorded in patients having elective primary THAs and KAs. Renal disease is now one of the most prevalent comorbidities in this patient population. Future research should explore whether this comorbidity trend has increased the burden on other medical specialities to optimize these patients before surgery and to provide additional postoperative care.Cite this article: Bone Joint J 2022;104-B(9):1052-1059.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Adulto , Estudios de Cohortes , Comorbilidad , Inglaterra/epidemiología , Humanos , Sistema de Registros
9.
Ann Med Surg (Lond) ; 77: 103655, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35479660

RESUMEN

Background: This observational study evaluates the trends in arthroplasty services across National Health Services (NHS) following the COVID-19 pandemic about GIRFT (Getting it Right First Time) guidelines concerning National joint registry data (NJR data). Introduction: Since the advent of the COVID-19 crisis sustainability of elective arthroplasty services have become a burning question in NHS. Capacity crisis, unknown COVID-19 infection status, lack of ring-fenced beds, winter crisis, and unprecedented trauma have aggravated the situation further leading to severe impairment in quality of life and service provision. GIRFT guidelines have suggested a few solutions to this crisis and one of them is dividing the hospitals into Hot (trauma) and cold (elective) sites. Objectives: To review NJR data for pre and post COVID era along with the service structure of the hospital and test the hypothesis that whether redistribution of services into hot and cold sites is a possible solution for sustainable arthroplasty service across NHS. Methodology: A search was made into the NJR data from 2019, 2020, and 2021. The First 7 months were taken from each year I.e. From Ist January to 31st of July. A review of entries for arthroplasty was considered for all hospitals across England and Wales. Hospitals in Scotland, Ireland, and Isles of Man and major trauma centers were excluded.Any hospital that was recording at least 15 arthroplasty cases for 4 out of 7 months in 2021 was considered for review. A brief evaluation of their service structure was made, and hospitals were divided into Elective Centres (EC), Urgent Care Centres (UCC), and District General Hospitals (DGH) with in-house emergency services based on the information provided on their official website. In NJR data "completed operations by submission date" column was considered as a reference for data collection. A total of 1807, 1800, and 1810 were identified for 2019, 2020, and 2021 respectively.However, after applying inclusion criteria total number of entries was reduced to 120 hospitals. Data analysis and selection of hospitals were reviewed twice by two authors (MMK and AP) at different times to avoid any bias and reduce the chances of human error that can affect the outcome. A sub-analysis of data for the last 3 months (May, June, and July) was also performed for the respective years to get a better picture of arthroplasty trends and reduce the flaws of data interpretation. Ethical approval and data consideration: A formal approval was taken from the NJR team in the UK before the data processing was initiated. The data source being used was available for public review on the NJR website. The team was happy for us to process and evaluate the data as per needs of our study. However, they requested a disclaimer and appreciation note for the members of the NJR team and hospital personnel across the UK that have made the provision of data and subsequent analysis leading to this study feasible. Results: 18 EC were included. The mean number of cases recorded per center was 427, 68, 348 for 2019, 2020, and 2021 respectively.20 UCC were identified. The mean number of cases performed were 213, 24, and 195 in 2019, 2020, and 2021 respectively.Similarly, 60 DGH with emergency services were included and the average number of cases recorded were 194, 27, and 166 for 2019, 2020, and 2021 respectively. Compared to 2019 out of 148 DGH in 2019 only 60 can provide a sustainable arthroplasty service signifying a drop of 40% in 2021 in the number of DGH which are contributing to elective services. Conclusions: The overall productivity of theatres in terms of arthroplasty services has decreased since the reinitialization of services in 2021. There is a need of hour to divide the services into hot and cold sites in terms of A/E and elective centers to provide safe and uninterrupted provision of arthroplasty services and address long waiting times for patients. Provisional of ring-fenced beds and arthroplasty wards is more technically feasible in centers that are not providing in-house emergency admission pathways or are specialist, dedicated elective centers.

10.
Bone Joint J ; 104-B(3): 359-367, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35227088

RESUMEN

AIMS: A recent report from France suggested an association between the use of cobalt-chrome (CoCr) femoral heads in total hip arthroplasties (THAs) and an increased risk of dilated cardiomyopathy and heart failure. CoCr is a commonly used material in orthopaedic implants. If the reported association is causal, the consequences would be significant given the millions of joint arthroplasties and other orthopaedic procedures in which CoCr is used annually. We examined whether CoCr-containing THAs were associated with an increased risk of all-cause mortality, heart outcomes, cancer, and neurodegenerative disorders in a large national database. METHODS: Data from the National Joint Registry was linked to NHS English hospital inpatient episodes for 374,359 primary THAs with up to 14.5 years' follow-up. We excluded any patients with bilateral THAs, knee arthroplasties, indications other than osteoarthritis, aged under 55 years, and diagnosis of one or more outcome of interest before THA. Implants were grouped as either containing CoCr or not containing CoCr. The association between implant construct and the risk of all-cause mortality and incident heart failure, cancer, and neurodegenerative disorders was examined. RESULTS: There were 158,677 individuals (42.4%) with an implant containing CoCr. There were 47,963 deaths, 27,332 heart outcomes, 35,720 cancers, and 22,025 neurodegenerative disorders. There was no evidence of an association between patients with CoCr implants and higher rates of any of the outcomes. CONCLUSION: CoCr-containing THAs did not have an increased risk of all-cause mortality, or clinically meaningful heart outcomes, cancer, or neurodegenerative disorders into the second decade post-implantation. Our findings will help reassure clinicians and the increasing number of patients receiving primary THA worldwide that the use of CoCr-containing implants is not associated with significant adverse systemic effects. Cite this article: Bone Joint J 2022;104-B(3):359-367.


Asunto(s)
Aleaciones de Cromo/efectos adversos , Cardiopatías/etiología , Cardiopatías/mortalidad , Prótesis de Cadera/efectos adversos , Neoplasias/etiología , Neoplasias/mortalidad , Enfermedades Neurodegenerativas/etiología , Enfermedades Neurodegenerativas/mortalidad , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Anciano , Anciano de 80 o más Años , Causas de Muerte , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Reino Unido
11.
Bone Joint J ; 104-B(3): 341-351, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35227094

RESUMEN

AIMS: Total hip arthroplasties (THAs) are performed by surgeons at various stages in training with varying levels of supervision, but we do not know if this is safe practice with comparable outcomes to consultant-performed THA. Our aim was to examine the association between surgeon grade, the senior supervision of trainees, and the risk of revision following THA. METHODS: We performed an observational study using National Joint Registry (NJR) data. We included adult patients who underwent primary THA for osteoarthritis, recorded in the NJR between 2003 and 2016. Exposures were operating surgeon grade (consultant or trainee) and whether or not trainees were directly supervised by a scrubbed consultant. Outcomes were all-cause revision and the indication for revision up to ten years. We used methods of survival analysis, adjusted for patient, operation, and healthcare setting factors. RESULTS: We included 603,474 THAs, of which 58,137 (9.6%) procedures were performed by a trainee. There was no association between surgeon grade and all-cause revision up to ten years (crude hazard ratio (HR) 1.00 (95% confidence interval (CI) 0.94 to 1.07); p = 0.966), a finding which persisted with adjusted analysis. Fully adjusted analysis demonstrated an association between trainees operating without scrubbed consultant supervision and an increased risk of all-cause revision (HR 1.10 (95% CI 1.00 to 1.21); p = 0.045). There was an association between trainee-performed THA and revision for instability (HR 1.14 (95% CI 1.01 to 1.30); p = 0.039). However, this was not observed in adjusted models, or when trainees were supervised by a scrubbed consultant. CONCLUSION: Within the current training system in England and Wales, appropriately supervised trainees achieve comparable THA survival to consultants. Trainees who are supervised by a scrubbed consultant achieve superior outcomes compared to trainees who are not supervised by a scrubbed consultant, particularly in terms of revision for instability. Cite this article: Bone Joint J 2022;104-B(3):341-351.


Asunto(s)
Artroplastia de Reemplazo de Cadera/normas , Competencia Clínica , Reoperación/estadística & datos numéricos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sistema de Registros , Medición de Riesgo
12.
Bone Joint J ; : 1-9, 2022 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-35018786

RESUMEN

AIMS: A recent report from France suggested an association between the use of cobalt-chrome femoral heads in total hip arthroplasties (THAs) and an increased risk of dilated cardiomyopathy and heart failure. Cobalt-chrome is a commonly used material in orthopaedic implants. If the reported association is causal, the consequences would be significant given the millions of joint replacements and other orthopaedic procedures in which cobalt-chrome is used annually. We examined whether cobalt-chrome-containing THAs were associated with an increased risk of all-cause mortality, heart outcomes, cancer, and neurodegenerative disorders in a large national database. METHODS: Data from the National Joint Registry was linked to NHS English hospital inpatient episodes for 374,359 primary THAs with up to 14.5 years follow-up. We excluded any patients with bilateral THAs, knee replacements, indications other than osteoarthritis, aged under 55 years, and diagnosis of one or more outcome of interest before THA. Implants were grouped as either containing cobalt-chrome or not containing cobalt-chrome. The association between implant construct and the risk of all-cause mortality and incident heart failure, cancer, and neurodegenerative disorders was examined. RESULTS: There were 158,677 individuals (42.4%) with an implant containing cobalt-chrome. There were 47,963 deaths, 27,332 heart outcomes, 35,720 cancers, and 22,025 neurodegenerative disorders. There was no evidence of an association that patients with cobalt-chrome implants had higher rates of any of the outcomes. CONCLUSION: Cobalt-chrome-containing THAs did not have an increased risk of all-cause mortality, or clinically meaningful heart outcomes, cancer or neurodegenerative disorders into the second decade post-implantation. Our findings will help reassure clinicians and the increasing number of patients receiving primary THA worldwide that the use of cobalt-chrome containing implants is not associated with significant adverse systemic effects.

13.
Bone Joint J ; 103-B(12): 1774-1782, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34847718

RESUMEN

AIMS: The aim of this study was to determine if uncemented acetabular polyethylene (PE) liner geometry, and lip size, influenced the risk of revision for instability or loosening. METHODS: A total of 202,511 primary total hip arthroplasties (THAs) with uncemented acetabular components were identified from the National Joint Registry (NJR) dataset between 2003 and 2017. The effect of liner geometry on the risk of revision for instability or loosening was investigated using competing risk regression analyses adjusting for age, sex, American Society of Anesthesiologists grade, indication, side, institution type, surgeon grade, surgical approach, head size, and polyethylene crosslinking. Stratified analyses by surgical approach were performed, including pairwise comparisons of liner geometries. RESULTS: The distribution of liner geometries were neutral (39.4%; 79,822), 10° (34.5%; 69,894), 15° (21.6%; 43,722), offset reorientating (2.8%; 5705), offset neutral (0.9%; 1,767), and 20° (0.8%; 1,601). There were 690 (0.34%) revisions for instability. Compared to neutral liners, the adjusted subhazard ratios of revision for instability were: 10°, 0.64 (p < 0.001); 15°, 0.48 (p < 0.001); and offset reorientating, 1.6 (p = 0.010). No association was found with other geometries. 10° and 15° liners had a time-dependent lower risk of revision for instability within the first 1.2 years. In posterior approaches, 10° and 15° liners had a lower risk of revision for instability, with no significant difference between them. The protective effect of lipped over neutral liners was not observed in laterally approached THAs. There were 604 (0.3%) revisions for loosening, but no association between liner geometry and revision for loosening was found. CONCLUSION: This registry-based study confirms a lower risk of revision for instability in posterior approach THAs with 10° or 15° lipped liners compared to neutral liners, but no significant difference between these lip sizes. A higher revision risk is seen with offset reorientating liners. The benefit of lipped geometries against revision for instability was not seen in laterally approached THAs. Liner geometry does not seem to influence the risk of revision for loosening. Cite this article: Bone Joint J 2021;103-B(12):1774-1782.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera , Diseño de Prótesis , Falla de Prótesis/etiología , Reoperación/estadística & datos numéricos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Polietileno , Modelos de Riesgos Proporcionales , Sistema de Registros , Riesgo , Adulto Joven
14.
Bone Joint J ; 103-B(11): 1717-1724, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34719266

RESUMEN

AIMS: The main objective of this study was to examine whether the Oxford Shoulder Score (OSS) demonstrated floor or ceiling effects when used to measure outcomes following shoulder arthroplasty in a large national cohort. Secondary objectives were to assess its pain and function subscales, and to identify independent predictors for patients achieving a postoperative ceiling score following shoulder arthroplasty. METHODS: Secondary database analysis of the National Joint Registry (NJR), which included 48,270 patients undergoing shoulder arthroplasty, was conducted. The primary outcome measure was the OSS. Secondary outcome measures were the OSS-Function Component Subscale and OSS-Pain Component Subscale. Floor and ceiling effects were considered to be present if > 15% of patients scored either the lowest or highest possible score. Logistic regression analysis was used to identify independent predictors for scoring the highest possible OSS score postoperatively. RESULTS: Preoperatively, 1% of patients achieved the lowest possible OSS score (0) and 0.4% of patients achieved the highest possible score (48). Postoperatively, < 1% of patients achieved the lowest score at all timepoints, but the percentage achieving the highest score at six months was 8.3%, at three years 16.9%, and at five years 17%. Male patients, those aged between 60 and 89 years, and those undergoing an anatomical total shoulder arthroplasty (ATSA) were more likely to contribute to the ceiling effect seen in the OSS questionnaire. Pain and function subscales exhibited greater ceiling effects at three years and five years when compared with the overall OSS questionnaire. Logistic regression analysis showed that sex, procedure type, and preoperative OSS score were independent predictors for scoring the highest possible OSS at years. CONCLUSION: Based on NJR patient-reported outcome measures data, the OSS does not exhibit a ceiling effect at six months, but does at three years and five years, in part due to outcome scores of ATSA. Preoperative OSS, age, male sex, and ATSA are independent predictors of achieving a ceiling score. Cite this article: Bone Joint J 2021;103-B(11):1717-1724.


Asunto(s)
Artritis/cirugía , Artroplastía de Reemplazo de Hombro , Lesiones del Hombro , Articulación del Hombro/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros , Autoinforme , Resultado del Tratamiento , Reino Unido
15.
Bone Joint J ; 103-B(11): 1669-1677, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34719277

RESUMEN

AIMS: To determine if primary cemented acetabular component geometry (long posterior wall (LPW), hooded, or offset reorientating) influences the risk of revision total hip arthroplasty (THA) for instability or loosening. METHODS: The National Joint Registry (NJR) dataset was analyzed for primary THAs performed between 2003 and 2017. A cohort of 224,874 cemented acetabular components were included. The effect of acetabular component geometry on the risk of revision for instability or for loosening was investigated using log-binomial regression adjusting for age, sex, American Society of Anesthesiologists grade, indication, side, institution type, operating surgeon grade, surgical approach, polyethylene crosslinking, and prosthetic head size. A competing risk survival analysis was performed with the competing risks being revision for other indications or death. RESULTS: The distribution of acetabular component geometries was: LPW 81.2%; hooded 18.7%; and offset reorientating 0.1%. There were 3,313 (1.5%) revision THAs performed, of which 815 (0.4%) were for instability and 838 (0.4%) were for loosening. Compared to the LPW group, the adjusted subhazard ratio of revision for instability in the hooded group was 2.31 (p < 0.001) and 4.12 (p = 0.047) in the offset reorientating group. Likewise, the subhazard ratio of revision for loosening was 2.65 (p < 0.001) in the hooded group and 13.61 (p < 0.001) in the offset reorientating group. A time-varying subhazard ratio of revision for instability (hooded vs LPW) was found, being greatest within the first three months. CONCLUSION: This registry-based study confirms a significantly higher risk of revision after cemented THA for instability and for loosening when a hooded or offset reorientating acetabular component is used, compared to a LPW component. Further research is required to clarify if certain patients benefit from the use of hooded or offset reorientating components, but we recommend caution when using such components in routine clinical practice. Cite this article: Bone Joint J 2021;103-B(11):1669-1677.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Diseño de Prótesis , Falla de Prótesis , Reoperación/estadística & datos numéricos , Acetábulo , Anciano , Anciano de 80 o más Años , Cementos para Huesos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Medición de Riesgo
16.
Bone Joint J ; 103-B(9): 1479-1487, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34465151

RESUMEN

AIMS: The aim of our study was to investigate the effect of asymmetric crosslinked polyethylene liner use on the risk of revision of cementless and hybrid total hip arthroplasties (THAs). METHODS: We undertook a registry study combining the National Joint Registry dataset with polyethylene manufacturing characteristics as supplied by the manufacturers. The primary endpoint was revision for any reason. We performed further analyses on other reasons including instability, aseptic loosening, wear, and liner dissociation. The primary analytic approach was Cox proportional hazard regression. RESULTS: A total of 213,146 THAs were included in the analysis. Overall, 2,997 revisions were recorded, 1,569 in THAs with a flat liner and 1,428 in THAs using an asymmetric liner. Flat liner THAs had a higher risk of revision for any reason than asymmetric liner THAs when implanted through a Hardinge/anterolateral approach (hazard ratio (HR) 1.169, 95% confidence interval (CI) 1.022 to 1.337) and through a posterior approach (HR 1.122, 95% CI 1.108 to 1.346). There was no increased risk of revision for aseptic loosening when asymmetric liners were used for any surgical approach. A separate analysis of the three most frequently used crosslinked polyethylene liners was in agreement with this finding. When analyzing THAs with flat liners only, THAs implanted through a Hardinge/anterolateral approach were associated with a reduced risk of revision for instability compared to posterior approach THAs (HR 0.561 (95% CI 0.446 to 0.706)). When analyzing THAs with an asymmetric liner, there was no significant difference in the risk of revision for instability between the two approaches (HR 0.838 (95% CI 0.633 to 1.110)). CONCLUSION: For THAs implanted through the posterior approach, the use of asymmetric liners reduces the risk of revision for instability and revision for any reason. In THAs implanted through a Hardinge/anterolateral approach, the use of an asymmetric liner was associated with a reduced risk of revision. The effect on revision for instability was less pronounced than in the posterior approach. Cite this article: Bone Joint J 2021;103-B(9):1479-1487.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera , Polietileno/química , Diseño de Prótesis , Reoperación/estadística & datos numéricos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Falla de Prótesis , Sistema de Registros
17.
Bone Joint J ; 103-B(12): 1791-1801, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34474593

RESUMEN

AIMS: The aim of this study was to investigate whether wear and backside deformation of polyethylene (PE) tibial inserts may influence the cement cover of tibial trays of explanted total knee arthroplasties (TKAs). METHODS: At our retrieval centre, we measured changes in the wear and deformation of PE inserts using coordinate measuring machines and light microscopy. The amount of cement cover on the backside of tibial trays was quantified as a percentage of the total surface. The study involved data from the explanted fixed-bearing components of four widely used contemporary designs of TKA (Attune, NexGen, Press Fit Condylar (PFC), and Triathlon), revised for any indication, and we compared them with components that used previous generations of PE. Regression modelling was used to identify variables related to the amount of cement cover on the retrieved trays. RESULTS: A total of 114 explanted fixed-bearing TKAs were examined. This included 76 used with contemporary PE inserts which were compared with 15 used with older generation PEs. The Attune and NexGen (central locking) trays were found to have significantly less cement cover than Triathlon and PFC trays (peripheral locking group) (p = 0.001). The median planicity values of the PE inserts used with central locking trays were significantly greater than of those with peripheral locking inserts (205 vs 85 microns; p < 0.001). Attune and NexGen inserts had a characteristic pattern of backside deformation, with the outer edges of the PE deviating inferiorly, leaving the PE margins as the primary areas of articulation. CONCLUSION: Explanted TKAs with central locking mechanisms were significantly more likely to debond from the cement mantle. The PE inserts of these designs showed characteristic patterns of deformation, which appeared to relate to the manufacturing process and may be exacerbated in vivo. This pattern of deformation was associated with PE wear occurring at the outer edges of the articulation, potentially increasing the frictional torque generated at this interface. Cite this article: Bone Joint J 2021;103-B(12):1791-1801.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Cementos para Huesos , Prótesis de la Rodilla , Polietileno , Diseño de Prótesis , Falla de Prótesis/etiología , Adulto , Anciano , Anciano de 80 o más Años , Remoción de Dispositivos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis de Regresión
18.
J Arthroplasty ; 36(10): 3498-3506, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34238620

RESUMEN

BACKGROUND: Prosthetic joint infection (PJI) is a devastating complication. Studies have suggested reduction in PJI with the use of ceramic bearings. METHODS: Adult patients who underwent total hip arthroplasty (THA) using an uncemented acetabular component with ceramic-on-ceramic (CoC), ceramic-on-polyethylene (CoP), or metal-on-polyethylene (MoP) bearing surfaces between 2002 and 2016 were extracted from the National Joint Registry for England, Wales, Northern Ireland, and the Isle of Man. A competing risk regression model to investigate predictors of each revision outcome was used. Time-to-event was determined by duration of implantation since primary surgery with competing risks being death or revision. The results were adjusted for age, gender, American Association of Anaesthesiologists grade, body mass index, surgical indication, intraoperative complications, and implant data. RESULTS: In total, 456,457 THAs (228,786 MoP, 128,403 CoC, and 99,268 CoP) were identified. Multivariable modeling showed that the risk of revision for PJI was significantly lower with CoC (risk ratio 0.748, P < .001) and CoP (risk ratio 0.775, P < .001) compared to MoP. Significant reduction in risk of aseptic and all-cause revision was also seen. The significant protective effect of ceramic bearing was predominantly seen 2 years after implantation. Aseptic revision beyond 2 years reduced by 18.1% and 24.8% for CoC and CoP (P < .001), respectively. All-cause revision rate beyond 2 years reduced by 21.6% for CoC and 27.1% for CoP (P < .001) CONCLUSION: This study demonstrates an association between the use of ceramic as part of the bearing, with lower rates of revision for all causes, revision for infection, and revision for aseptic causes, supporting ceramic bearings in THA.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/efectos adversos , Cerámica , Inglaterra/epidemiología , Prótesis de Cadera/efectos adversos , Humanos , Irlanda del Norte/epidemiología , Diseño de Prótesis , Sistema de Registros , Reoperación , Factores de Riesgo , Gales/epidemiología
19.
J Arthroplasty ; 36(4): 1239-1245.e6, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33160808

RESUMEN

BACKGROUND: The National Joint Registry for England, Wales, Northern Ireland and the Isle of Man (NJR) has monitored the performance of consultant surgeons performing primary total hip (THR) or knee replacements (KR) since 2007. The aims of this study were: 1) To describe the surgical practice of consultant hip and knee replacement surgeons in the National Joint Registry for England and Wales (NJR), stratified by potential outlier status for revisions. 2) To compare the practice of revision outlier and non-outlier surgeons. METHODS: We combined NJR primary THR and KR data from 2008-2017 separately with relevant anonymised NJR outlier notification records. We described the surgical practice of outliers and non-outliers by surgical workload, implant choice, and patients' clinical and demographic characteristics. We explored associations between surgeon-level factors and outlier status with conditional logistic regression models. RESULTS: We included 764,888 primary THRs by 3213 surgeons and 889,954 primary KRs by 3084 surgeons performed between 2008-2017. One hundred and eleven (3.5%) THR and 114 (3.7%) KR consultant surgeons were potential revision outliers. Surgeons who used more types of implant had increased odds of being an outlier (KR: OR/additional implant = 1.35, 95%CI 1.17-1.55; THR: OR = 1.12, 95%CI 1.06-1.18). CONCLUSIONS: The use of more types of implant is associated with increased risk of being a potential revision outlier. Further research is required to understand why surgeons use many different implants and to what extent this is responsible for the effects observed here.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Cirujanos , Estudios de Casos y Controles , Inglaterra , Humanos , Irlanda del Norte , Sistema de Registros , Reoperación , Gales
20.
BMC Med ; 18(1): 335, 2020 11 18.
Artículo en Inglés | MEDLINE | ID: mdl-33203455

RESUMEN

BACKGROUND: Prosthetic joint infection (PJI) following total hip replacement (THR) surgery is a serious complication that negatively impacts patients' lives and is financially burdensome for healthcare providers. As the number of THRs increases, so does this financial burden. This research estimates the economic burden with respect to inpatient and day case hospital admissions for patients receiving revision surgery for PJI following primary THR. METHODS: In this matched cohort study, the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man (NJR) was used to identify patients. Patients revised for PJI with a one- or two-stage revision following THR and patients not revised for PJI were matched on several characteristics using exact and radius matching. Hospital inpatient and day case healthcare records from the English Hospital Episode Statistics database were obtained for 5 years following the identified patient's primary THR. UK national unit costs were applied to hospital admissions and the 5-year total cost was estimated. A two-part model (Probit and generalised linear model) was employed to estimate the incremental difference in costs between those revised and not revised for PJI. RESULTS: Between 2006 and 2009, 1914 revisions for PJI were identified in the NJR. The matching resulted in 422 patients revised for PJI and 1923 matches not revised for PJI who were included in the analysis. The average cost of inpatient and day case admissions in the 5 years following primary THR was approximately £42,000 for patients revised for PJI and £8000 for patients not revised for PJI. The difference in costs over the 5 years was £33,452 (95% CI £30,828 to £36,077; p < 0.00). CONCLUSIONS: In the 5 years following primary THR, patients who develop PJI and have revision surgery cost approximately £33,000 (over 5-fold) more than patients not revised for PJI based on their hospital inpatient and day case admissions alone. The total burden of PJI is likely to be much higher when also considering outpatient, primary and community care costs. This highlights the need to find both ways to reduce the incidence of PJI following THR and cost-effective treatment strategies if PJI occurs.


Asunto(s)
Artroplastia de Reemplazo de Cadera/economía , Infecciones Relacionadas con Prótesis/economía , Infecciones Relacionadas con Prótesis/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/métodos , Estudios de Cohortes , Femenino , Humanos , Pacientes Internos , Masculino , Persona de Mediana Edad , Sistema de Registros , Factores de Riesgo , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...