RESUMEN
In a chamber-based digital PCR (dPCR) chip fabricated with polydimethylsiloxane (PDMS), bubble generation in the chambers at high temperatures is a critical issue. Here, we found that the main reason for bubble formation in PDMS chips is the too-high saturated vapor pressure of water at an elevated temperature. The bubbles should be completely prevented by reducing the initial pressure of the system to under 13.6 kPa to eliminate the effects of increased-pressure water vapor. Then, a cavity was designed and fabricated above the PCR reaction layer, and Parylene C was used as a shell covering the chip. The cavity was used for the negative generator in sample loading, PDMS degassing, PCR solution degassing in the digitization process and water storage in the thermal reaction process. The analysis was confirmed and finally achieved a desirable bubble-free, fast-digitization, valve-free and no-tubing connection dPCR.
Asunto(s)
Dimetilpolisiloxanos , Vapor , Reacción en Cadena de la PolimerasaRESUMEN
The World Health Organization (WHO) has stated that countless cancer patients could be saved if early detection and treatment were available. However, current clinical evaluation of tumors still relies primarily on imaging examinations and tissue biopsies. These methods not only require sophisticated equipment, but also have high false positive rates or invasive problems. Here, we describe a digital polymerase chain reaction (dPCR) chip for the detection of biomarkers in salivary extracellular vesicles (SEVs), which can be used to identify markers for the early diagnosis of tumors. Based on microfluidic technology fine microstructure and microfluidics operations, this dPCR chip can accurate quantitative SEVs in a variety of tumor markers, and shows extremely strong sensitivity (10 copies). In the detection of clinical samples, the chip can effectively distinguish lung cancer cases from normal controls (P < 0.001; two-tailed t-test), and in the detection of extremely low concentration samples, it shows considerably higher precise quantitative ability than quantitative real-time polymerase chain reaction (qPCR). Overall, this study may shed new light on non-invasive early screening of tumor markers by detecting extracellular vesicle-associated markers in saliva.
Asunto(s)
Vesículas Extracelulares , Neoplasias Pulmonares , Humanos , Biomarcadores de Tumor/genética , Neoplasias Pulmonares/patología , Reacción en Cadena en Tiempo Real de la Polimerasa , Vesículas Extracelulares/genética , Vesículas Extracelulares/patologíaRESUMEN
Real-time Polymerase Chain Reaction (RT-PCR), a molecular diagnostic technology, is spotlighted as one of the quickest and fastest diagnostic methods for the actual coronavirus (SARS-CoV-2). However, the fluorescent label-based technology of the RT-PCR technique requires expensive equipment and a sample pretreatment process for analysis. Therefore, this paper proposes a biochip based on Electrochemical Impedance Spectroscopy (EIS). In this paper, it was possible to see the change according to the concentration by measuring the impedance with a chip made of two electrodes with different shapes of sample DNA.
Asunto(s)
COVID-19 , Amplificación de Genes , Humanos , ARN Viral/análisis , SARS-CoV-2/genética , COVID-19/diagnóstico , ElectrodosRESUMEN
The lack of reliable and practical method for detecting rare hot mutation of epidermal growth factor receptor (EGFR) in circulating tumor DNA (ctDNA) for lung cancer has remained a challenge for general clinical application due to excess wild type DNA in clinical samples. In this study, we developed a droplet digital PCR (ddPCR) platform, integrating a PDMS chip and double-layer glass reservoir. The duplex T-junction droplet generators in PDMS chip can produce about one million uniform droplets of 4.187 pL within â¼10 min, which were then stored in the glass reservoir. The double-layer glass reservoir can protect droplets from evaporation and breaking, solving the problem of instability during thermal-cycling. The quantitative capabilities of the ddPCR chip were evaluated by testing EGFR exon gene 21, with a good linear correlation in the wide range of 101 to 106 copies/µL (R2 = 0.9998). We then demonstrated that the proposed ddPCR device can recognize rare EGFR L858R mutation under a background of 106 copies/µL wild-type DNA at a sensitivity of 0.0001%. Finally, we demonstrated this ddPCR platform could identify low amount of EGFR L858R mutation in ctDNA and CTCs of patients with lung cancer.
Asunto(s)
ADN Tumoral Circulante , Neoplasias Pulmonares , ADN Tumoral Circulante/genética , Receptores ErbB/genética , Genes erbB-1 , Humanos , Neoplasias Pulmonares/diagnóstico , Mutación , Reacción en Cadena de la Polimerasa/métodosRESUMEN
Food poisoning and infectious diseases caused by Salmonella typhimurium (S. typhimurium) are serious public health concerns for human health and food safety. The diversity and complexity of food matrices pose great challenges for rapid and ultra-sensitive detection of S. typhimurium in food samples. A method capable of identification, detection, and quantification of S. typhimurium is essential for addressing these issues. In this study, aptamer-coated magnetic beads (Apt-MBs) are employed as capture bio-probes to specifically and selectively concentrate S. typhimurium in food samples. A self-priming chip-based digital PCR was then presented as another biosensor for on-site detection and quantification of S. typhimurium cells. The chip we developed was robust and did not require any external power for sample loading. The combination of Apt-MBs with an on-chip digital detection realized the integration into lab-on-a-chip-based biosensors for on-site monitoring of foodborne pathogens. It was possible to capture and detect S. typhimurium cells as low as 90 CFU/reaction with a capture efficiency of 94.5%. Additionally, the whole process only took about 2 h. This unique platform could also be used to monitor other target bacteria with high specificity and sensitivity by utilizing different aptamers. Furthermore, the platform has potential applications in point-of-care testing in the future.
Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Técnicas Biosensibles/métodos , Microbiología de Alimentos , Humanos , Separación Inmunomagnética/métodos , Reacción en Cadena de la Polimerasa , Salmonella typhimurium/genéticaRESUMEN
The lack of portability and high cost of multiplex real-time PCR systems limits the device to be used in POC. To overcome this issue, this paper proposes a compact and cost-effective fluorescence detection system that can be integrated to a multiplex real-time PCR equipment. An open platform camera with embedded lens was used instead of photodiodes or an industrial camera. A compact filter wheel using a sliding tape is integrated, and the excitation LEDs are fixed at a 45° angle near the PCR chip, eliminating the need of additional filter wheels. The results show precise positioning of the filter wheel with an error less than 20 µm. Fluorescence detection results using a reference dye and standard DNA amplification showed comparable performance to that of the photodiode system.
Asunto(s)
Técnicas de Amplificación de Ácido Nucleico , Análisis Costo-Beneficio , Análisis de Secuencia por Matrices de Oligonucleótidos , Reacción en Cadena de la PolimerasaRESUMEN
Most existing commercial real-time polymerase chain reaction (RT-PCR) instruments are bulky because they contain expensive fluorescent detection sensors or complex optical structures. In this paper, we propose an RT-PCR system using a camera module for smartphones that is an ultra small, high-performance and low-cost sensor for fluorescence detection. The proposed system provides stable DNA amplification. A quantitative analysis of fluorescence intensity changes shows the camera's performance compared with that of commercial instruments. Changes in the performance between the experiments and the sets were also observed based on the threshold cycle values in a commercial RT-PCR system. The overall difference in the measured threshold cycles between the commercial system and the proposed camera was only 0.76 cycles, verifying the performance of the proposed system. The set calibration even reduced the difference to 0.41 cycles, which was less than the experimental variation in the commercial system, and there was no difference in performance.
Asunto(s)
Técnicas de Amplificación de Ácido Nucleico , Teléfono Inteligente , Análisis de Secuencia por Matrices de Oligonucleótidos , Reacción en Cadena en Tiempo Real de la PolimerasaRESUMEN
Circulating tumor DNA (ctDNA) is a promising biomarker for tumor genotyping and therapy monitoring. Herein, we developed a digital PCR chip with embedded microwell and bidirectional partition network for highly sensitive ctDNA analysis. The embedded microwell contributes to increasing microreaction density (up to 7000 microwells/cm2) and reducing evaporation during amplification. The bidirectional partition network can achieve fast and random distribution of targets, ensuring the precise quantification of nucleic acid. We used plasmids, artificial samples and 32 clinical blood samples from non-small cell lung cancer patients to test the performance of this platform. The results demonstrated that our chip has not only comparable quantification performance to commercial counterpart but also the ability to detect EGFR mutations with as low as 0.01% mutation rate and 20 alter molecules in 27 ng genomic DNA. The identification of EGFR mutations in plasma using developed chip exhibited 85.71% sensitivity and 94.44% specificity for L858R mutation and 100% sensitivity and 86.96% specificity for T790 M mutation. Moreover, the monitoring of mutant allele in plasma was accomplished in this work. In conclusion, the developed chip has a potential in lung tumor genotyping and therapy monitoring for precision medicine, even other tumors.
Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Carcinoma de Pulmón de Células no Pequeñas/genética , Receptores ErbB/genética , Humanos , Neoplasias Pulmonares/genética , Microfluídica , MutaciónRESUMEN
An ultra-high-throughput workflow for next-generation sequencing library construction at nanoliter scale for amplicon sequencing, termed Smartchip Nanowell Platform for Target Enrichment, was established using a nanodispenser system and a nanoliter-scale PCR chip. To demonstrate its cost and time advantages over conventional methods for library construction, quality control and pooling for large-scale samples, target amplicon sequencing of the 16S ribosomal RNA gene V3-V4 region widely used for microbial community profiling was chosen for comparison. The finding of no significant difference in microbial community profiling between the two methods strongly supports the conclusion that Smartchip Nanowell Platform for Target Enrichment is a cost-effective method for next-generation sequencing library construction for large-scale samples to conduct amplicon sequencing-based applications.
Asunto(s)
ADN Bacteriano/genética , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Microbiota/genética , ARN Ribosómico 16S/genética , Análisis de Secuencia de ADN/métodos , Biblioteca de Genes , NanotecnologíaRESUMEN
Since the increment of the threat to public health caused by foodborne pathogens, researches have been widely studied on developing the miniaturized detection system for the on-site pathogen detection. In the study, we focused on the development of portable, robust, and disposable film-based polymerase chain reaction (PCR) chip containing a multiplex chamber for simultaneous gene amplification. In order to simply fabricate and operate a film-based PCR chip, different kinds of PCR chambers were designed and fabricated using polyethylene terephthalate (PET) and polyvinyl chloride (PVC) adhesive film, in comparison with commercial PCR, which employs a stereotyped system at a bench-top scale. No reagent leakage was confirmed during the PCR thermal cycling using the film PCR chip, which indicates that the film PCR chip is structurally stable for rapid heat cycling for DNA amplification. Owing to use of the thin film to fabricate the PCR chip, we are able to realize fast thermal transfer from the heat block that leads to short PCR amplification time. Moreover, using the film PCR chip, we could even amplify the target pathogen with 10 CFU mL-1. The artificially infected milk with various concentration of Bacillus cereus was successfully amplified on a single film PCR chip. On the basis of the reliable results, the developed film PCR chip could be a useful tool as a POCT device to detect foodborne pathogens via genetic analysis.
Asunto(s)
Contaminación de Alimentos/análisis , Reacción en Cadena de la Polimerasa/instrumentación , Reacción en Cadena de la Polimerasa/métodos , Animales , Bacillus cereus/genética , Bacillus cereus/aislamiento & purificación , Calor , Leche/microbiologíaRESUMEN
Polymerase chain reaction (PCR) has been widely used for major definite diagnostic tool, but very limited its place used only indoor such as hospital or diagnosis lab. For the rapid on-site detection of pathogen in an outdoor environment, a low-power cordless polymerase chain reaction (PCR) thermal cycler is crucial module. At this point of view, we proposed a low-power PCR thermal cycler that could be operated in an outdoor anywhere. The disposable PCR chip was made of a polymeric (PI/PET) film to reduce the thermal mass. A dual arrangement of the Pt heaters, which were positioned on the top and bottom of the PCR chip, improved the temperature uniformity. The temperature sensor, which was made of the same material as the heater, utilized the temperature dependence of the Pt resistor to ensure simple fabrication of the temperature sensor. Cooling the PCR chip using dual blower fans enabled thermal cycling to operate with a lower power than that of a Peltier element with a high power consumption. The PCR components were electrically connected to a control module that could be operated with a Li-ion battery (12 V), and the PCR conditions (temperature, time, cycle, etc.) were inputted on a touch screen. For 30 PCR cycles, the accumulated power consumption of heating and cooling was 7.3 Wh, which is easily available from a compact battery. Escherichia coli genomic DNA (510 bp) was amplified using the proposed PCR thermal cycler and the disposable PCR chip. A similar DNA amplification capability was confirmed using the proposed portable and low-power thermal cycler compared with a conventional thermal cycler.
Asunto(s)
Reacción en Cadena de la Polimerasa/instrumentación , Suministros de Energía Eléctrica , Diseño de Equipo , Escherichia coli/genética , Tereftalatos Polietilenos/química , Reacción en Cadena de la Polimerasa/métodos , Polímeros/química , TemperaturaRESUMEN
Amino acid transporter plays an important role in regulating mTOR signaling pathway. This study investigated the effects of reduced dietary protein levels on amino acid transporters and mTOR signaling pathway. A total of 54 weaning pigs were randomly allocated into a 3 × 3 factorial design, followed by slaughtering the pigs separately after 10-, 25- and 45-day feeding, with 18 pigs from each feeding period divided into three subgroups for treatment with three different protein-level diets: 20% crude protein (CP) diet (normal recommended, high protein, HP), 17% CP diet (medium protein, MP) and 14% CP diet (low protein, LP). The results indicated that reduced dietary protein level decreased the weight of longissimus dorsi. Additionally, quantitative PCR chip analysis showed that mRNA expression of amino acid transporters SLC38A2, SLC1A7, SLC7A1, SLC7A5, SLC16A10 and SLC3A2 in the LP group were significantly (P < 0.05) higher than those in the MP or HP group, and the phosphorylation of mTOR and S6K1 decreased in the LP group after 25-day feeding. Furthermore, the vitro experimental results further confirmed that the mRNA levels for SLC7A1, SLC7A5, SLC3A2, SLC38A2 and SLC36A1 were increased and the phosphorylation of mTOR and S6K1 was decreased when the concentration of amino acids in C2C12 myoblasts was reduced. All these results indicated that the LP diet induced a high expression of amino acid transporters and the inhibition of the mTOR activity, which resulting in restriction on protein synthesis and longissimus dorsi growth.
Asunto(s)
Sistemas de Transporte de Aminoácidos/genética , Dieta con Restricción de Proteínas , Regulación de la Expresión Génica , Transducción de Señal , Sus scrofa/fisiología , Serina-Treonina Quinasas TOR/metabolismo , Sistemas de Transporte de Aminoácidos/metabolismo , Animales , Peso Corporal , Biosíntesis de Proteínas , ARN Mensajero/genética , Sus scrofa/genética , Sus scrofa/crecimiento & desarrolloRESUMEN
This study aims to explore the potential pathways and molecular characteristics of fluorine-induced osteoblast apoptosis. In vitro fluorine-induced model was established with an osteogenesis sarcoma cell line Saos-2. Then flow cytometry was used to determine the mitochondrial membrane potential at 24 h after the intervention. 84 apoptosis-related genes in the cells were determined using the functional polymerase chain reaction (PCR) chip and part of the differentially expressed genes was verified with immune blotting. When the stimulated concentration of sodium fluoride were 20 mg/L, 40 mg/L and 80 mg/L, the mitochondrial membrane potential of the osteoblast cells were 27.0%, 28.8% and 38.6%, respectively, significantly higher than that in the blank control group (P<0.05). The PCR chip detection found 13 up-regulating genes and 15 down-regulating genes, among which the expression of Bim, Caspase 9, Caspase 14, B-cell lymphoma-2 (BCL2) and BAX increased with the doses of sodium fluoride, while the expression of Caspase 3 down-regulated in 5 mg/L sodium fluoride but up-regulated at the concentration of sodium fluoride more than 10 mg/L. Caspase 7 expression showed no obvious difference between the different concentration groups. However, Caspase 10 decreased with the increasing doses of sodium fluoride. Fluoride-induced osteoblast apoptosis may be through the mitochondrial pathway (including endoplasmic reticulum stress pathway) and death receptor pathway.
RESUMEN
This paper proposes the optimal structure of a PCB-based micro PCR chip constructed on a PCB substrate using commercial adhesive tapes and plastic covers. The solder mask of the PCB substrate was coated black, and the area where the reaction chamber is attached was legend printed with white silk to minimize the noise during fluorescence detection. The performance of the PCR and fluorescence detection was compared using 6 types of reaction chambers, each made with different double-sided tapes. Three of the chambers were unsuccessful in completing the PCR. The performance of the other three chambers that successfully amplified DNA was compared using Taqman probe for Chlamydia Trachomatis DNA. The amplified product was illuminated diagonally with a blue LED to excite the product just before imaging, and the LED was turned off when the image was captured to prevent quenching of the probe. The images were taken 10 seconds prior to the last extension step for each cycle using a DSLR camera. The experiments were run as a quartet for each three chambers made with different double-sided tape. The results showed that there were significant difference between the three tapes.