Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Magn Reson Med ; 84(4): 1734-1746, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32112451

RESUMEN

PURPOSE: To translate the recently developed PRO-QUEST (Progressive saturation for quantifying exchange rates using saturation times) sequence from preclinical 9.4T to 3T clinical magnetic field strength. METHODS: Numerical simulations were performed to define the optimal saturation flip angles for PRO-QUEST saturation pulses at 3T and demonstrate the effect of a ∆T2 error on the exchange rate (kex ) estimation at various field strengths. Exchange-dependent relaxation rate (Rex ) was measured for glutamate solutions in various pH, healthy volunteers and patients with multiple sclerosis (MS). Additionally, concentration-independent ratiometric Rex maps were produced to evaluate regional signal variations across the brain of human volunteers. RESULTS: The calculated Rex significantly correlates with pH in glutamate samples, however, kex values are underestimated as compared to those previously obtained at 9.4T. In the ratiometric Rex map of healthy volunteers, no significant differences are found between grey matter, white matter, and basal ganglia. In patients with MS, white matter lesions are visible in single saturation power Rex maps whereas only a periventricular lesion is apparent in the ratiometric Rex map. CONCLUSION: We demonstrate that quantification of pH sensitive indices using PRO-QUEST is feasible at 3T within clinically acceptable acquisition times. Our initial findings in patients with MS show that pH sensitive indices varied with the type of lesion examined whereas no significant difference was found in healthy volunteers between tissue types, suggesting that it would be worthwhile to apply PRO-QUEST in a larger cohort of patients to better understand its distinct imaging features relative to conventional techniques.


Asunto(s)
Imagen por Resonancia Magnética , Sustancia Blanca , Encéfalo/diagnóstico por imagen , Sustancia Gris , Humanos , Concentración de Iones de Hidrógeno
2.
Magn Reson Med ; 80(4): 1638-1654, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29504144

RESUMEN

PURPOSE: To develop a new MRI technique to rapidly measure exchange rates in CEST MRI. METHODS: A novel pulse sequence for measuring chemical exchange rates through a progressive saturation recovery process, called PRO-QUEST (progressive saturation for quantifying exchange rates using saturation times), has been developed. Using this method, the water magnetization is sampled under non-steady-state conditions, and off-resonance saturation is interleaved with the acquisition of images obtained through a Look-Locker type of acquisition. A complete theoretical framework has been set up, and simple equations to obtain the exchange rates have been derived. RESULTS: A reduction of scan time from 58 to 16 minutes has been obtained using PRO-QUEST versus the standard QUEST. Maps of both T1 of water and B1 can simply be obtained by repetition of the sequence without off-resonance saturation pulses. Simulations and calculated exchange rates from experimental data using amino acids such as glutamate, glutamine, taurine, and alanine were compared and found to be in good agreement. The PRO-QUEST sequence was also applied on healthy and infarcted rats after 24 hours, and revealed that imaging specificity to ischemic acidification during stroke was substantially increased relative to standard amide proton transfer-weighted imaging. CONCLUSION: Because of the reduced scan time and insensitivity to nonchemical exchange factors such as direct water saturation, PRO-QUEST can serve as an excellent alternative for researchers and clinicians interested to map pH changes in vivo.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Animales , Encéfalo/diagnóstico por imagen , Infarto Encefálico/diagnóstico por imagen , Masculino , Fantasmas de Imagen , Ratas , Ratas Sprague-Dawley
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...