Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Pak Med Assoc ; 73(4): 925-928, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37052018

RESUMEN

Superior mesenteric artery (SMA) aneurysm is a rare disease, especially if it is mycotic (infective) in origin. It is difficult to detect the problem during its initial natural course and usually presents in late phase due to its complications such as rupture, dissection, haemorrhage, and mesenteric ischaemia. Initially, the patient present with non-specific symptoms like vague colicky abdominal pain, nausea, vomiting, discomfort, malaise, and low-grade fever but prompt workup and intervention can lead to definitive diagnosis and uneventful outcome. This report describes the case of a 60-year-old male patient who presented with non-specific abdominal symptoms and, on workup, was diagnosed with superior mesenteric artery mycotic aneurysm. It was successfully treated surgically by resection of aneurysm and reconstruction of superior mesenteric artery by inter-positional Polytetrafluoroethylene (PTFE) synthetic vascular graft.


Asunto(s)
Aneurisma Infectado , Enfermedades Gastrointestinales , Isquemia Mesentérica , Masculino , Humanos , Persona de Mediana Edad , Aneurisma Infectado/diagnóstico por imagen , Aneurisma Infectado/cirugía , Arteria Mesentérica Superior/diagnóstico por imagen , Arteria Mesentérica Superior/cirugía , Abdomen
2.
JTCVS Tech ; 17: 159-163, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36820339

RESUMEN

Objectives: Congenital tracheomalacia can be the cause of respiratory failure in young children. Although the indication for surgical treatment has already been discussed vigorously, no clear guidelines about the modality are available. Methods: Through a sternotomy approach, a combination of posterior pexy and anterior tracheopexy using a tailored ringed polytetrafluoroethylene prosthesis is performed. Patient demographic characteristics, as well as operative details and postoperative outcomes, are included in the analysis. Results: Between 2018 and 2022, 9 children underwent the operation under review. All patients showed severe clinical symptoms of tracheomalacia, which was confirmed on bronchoscopy. The median age was 9 months. There was no operative mortality. Eight patients could be weaned from the ventilator. One patient died because of interstitial lung disease with bronchomalacia and concomitant severe cardiac disease. The longest follow-up now is 4 years, and shows overall excellent clinical results, without any reintervention. Conclusions: Surgical treatment of tracheomalacia through a combination of posterior and anterior pexy is feasible, with acceptable short- and midterm results.

3.
J Mass Spectrom Adv Clin Lab ; 27: 24-32, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36593910

RESUMEN

Background: Steroids play a key role in numerous physiological processes. Steroid determination is a useful tool to explore various endocrine diseases. Because of its specificity, mass spectrometry is considered to be a reference method for the determination of steroids in serum compared to radioimmunoassay. This technology could progress towards more automation for the optimal organization of clinical laboratories and ultimately for the benefit of patients. Methods: A fully automated ultra-high-performance liquid chromatography-tandem mass spectrometry method was developed and fully validated to determine five steroids in serum. Sample preparation was based on protein precipitation with filtration followed by online solid phase extraction. Chromatographic separation was performed using a biphenyl stationary phase. Results: The method was successfully validated according to European Medicine Agency guidelines. Coefficients of variation did not exceed, respectively, 8.4% and 8.1% for intra- and inter-assay precision. Method comparison with radioimmunoassay showed a proportional bias for all compounds, except for testosterone in men. Comparison with another LC-MS/MS method demonstrated acceptable concordance for all steroids, although a small bias was observed for androstenedione. Conclusion: The novelty of this method is that it has been fully automated. Automation provides benefits in traceability and allows significant savings in cost and time.

4.
Urol Case Rep ; 46: 102311, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36606097

RESUMEN

Nutcracker syndrome (NCS) is a rare condition caused by compression of the left renal vein (LRV) between the aorta and superior mesenteric artery. Surgical treatment is reserved for patients with severe symptoms and failure of conservative treatment. A 31-year-old woman diagnosed in adolescence with NCS has had recurrent pain since age 15. For 30 days, she has had severe left flank pain and microhematuria. The patient underwent extravascular stent placement around the LRV with the Da Vinci Xi. In 30 months of follow-up, the patient has no pain and the LRV remained without compressions or thrombosis.

5.
JACC Case Rep ; 4(22): 1504-1508, 2022 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-36444188

RESUMEN

Gaucher type 3C disease with porcelain aorta can cause severe hemodynamic impairment. We report the first case, to our knowledge, of a 13-year-old Mexican girl with a GBA1 homozygous c.1342G>C [p.Asp448His] (commonly known as p.D409H) pathogenic variant who underwent extensive aortic replacement. She has been on enzyme replacement therapy and is alive 5 years after surgery. (Level of Difficulty: Intermediate.).

6.
Saudi Dent J ; 34(7): 617-622, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36267533

RESUMEN

Objective: The retention of glass fiber post (GFP) is considered a key factor for the long-term success of restorations of endodontically treated teeth. This study aimed to compare the compressive strength of a ceramic crown supported by a GFP using different luting agents. Methods: Forty single-rooted premolars were randomly divided into four groups (n = 10 each): control group (teeth without a GFP), Ketac Cem group (glass ionomer), RelyX ARC group (conventional dual-curing resin), and RelyX U200 group (self-adhesive dual-curing resin). After luting of the posts and placement of all-ceramic crowns made using feldspathic porcelain (Noritake EX-3), they were exposed to thermocycling for 1000 cycles and compressive strength tests. Statistical analysis included Kruskal-Wallis test with Dunn's multi-comparison test. Results: The Ketac Cem group and RelyX U200 group showed significantly greater fracture resistance to compressive loading than the control group. Conclusion: This study indicates a possible role of the luting agent used with the GFP in influencing the compressive strength of the restored teeth. In this study, the self-adhesive dual-curing resin and glass ionomer both offered resistance to fractures.

7.
JTCVS Tech ; 13: 250-260, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35711227

RESUMEN

Objectives: The aim of the study is to evaluate clinical applications, safety, and effectiveness of a porcine-derived acellular cross-linked dermal matrix biological mesh in chest wall reconstruction. Methods: We retrospectively analyzed a prospective multicenter database of chest wall reconstructions using a biological mesh in adult patients undergoing operation between October 2013 and December 2020. We evaluated preoperative data, type of resection and reconstruction, hospitalization, 30-day morbidity and mortality, and overall survival. Results: A total of 105 patients (36 women [34.2%]; mean age, 57.0 ± 16.1 years; range, 18-90 years) were included, they have admitted for: primary chest wall tumor (n = 52; 49.5%), secondary chest wall tumor (n = 29; 27.6%), lung hernia (n = 12; 11.4%), trauma (n = 10; 9.6%), and infections (n = 2; 1.9%). The surgical sites were preoperatively defined as at high risk of infection in 28 patients (26.7%) or as infected in 16 (15.2%) patients. Thirty-days morbidity was 30.5% (n = 32 patients); 14 patients (13.3%) had postoperative complications directly related to chest wall surgical resection and/or reconstruction. We experienced no 30-day mortality; 1-year and 2-year mortality was 8.4% and 16.8%, respectively. Conclusions: Biological mesh represents a valuable option in chest wall reconstruction even when surgical sites are infected or at high-risk of infections. This mesh shows low early and late postoperative complication rates and excellent long-term stability.

8.
J Mass Spectrom Adv Clin Lab ; 24: 107-117, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35602306

RESUMEN

Introduction: Quantitation of the isomeric branched-chain amino acids (BCAA; valine, alloisoleucine, isoleucine, leucine) is a challenging task that typically requires derivatization steps or long runtimes if a traditional chromatographic method involving a ninhydrin ion pairing reagent is used. Objectives: To develop and perform clinical validation of a rapid, LC-MS/MS-based targeted metabolomics assay for detection and monitoring of underivatized BCAA in human plasma. Methods: Various columns and modes of chromatography were tested. The final optimized method utilized mixed mode chromatography with an Intrada column under isocratic condition. Sample preparation utilized the 96-well format. Briefly, extraction solvent containing the internal standard is added to 20 uL of sample, followed by shaking and positive pressure filtering, and the resulting extracted sample is analyzed. The assay was validated based on accepted quality standards (e.g., CLIA and CLSI) for clinical assays. Results: The method is linear over a wide range of concentrations, 2.0-1500 µM, with LOD of 0.60 µM and LOQ of 2.0 µM. The precision of the assay was 4-10% across analytes. The method was also validated against reference laboratories via blinded split-sample analysis and demonstrated good agreement with accuracy: 89-95% relative to the external group mean. Conclusion: We have developed a method that is accurate, rapid, and reliable for routine clinical testing of patient sample BCAA, which is used in the diagnosis and management of maple syrup urine disease (MSUD). The assay also has desirable characteristics, such as short run time, small sample volume requirement, simple sample preparation without the need for derivatization, and high throughput.

9.
J Clin Exp Hepatol ; 12(2): 595-602, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35535060

RESUMEN

Acute variceal bleeding is the major cause of mortality in patients with cirrhosis. The standard medical and endoscopic treatment has reduced the mortality of variceal bleeding from 50% to 10-20%. The refractory variceal bleed is either because of failure to control the bleed or failure of secondary prophylaxis. The patients refractory to standard medical therapy need further interventions. The rescue therapies include balloon tamponade, self-expanding metal stents (SEMS) placement, shunt procedures, including transjugular intrahepatic portosystemic shunt (TIPS), balloon-occluded retrograde transvenous obliteration (BRTO), and endoscopic ultrasound (EUS) guided coiling. In cases where endoscopic variceal ligation (EVL) has failed and the variceal bleeding continues, temporary measures like balloon tamponade can be used to achieve hemostasis and as a bridge to definitive measures. SEMS being in use for refractory bleed is preferred over balloon tamponade due to the reduced complication rate. The shunting procedures are highly effective in reducing portal pressure and represent the gold standard for uncontrolled variceal bleeding. The surgical shunts, as well as nonshunt surgeries such as devascularization have become less popular with the increasing use of minimally invasive techniques like TIPS. TIPS have high success rates in controlling refractory variceal bleeding. The mortality rate is greater in high-risk patients undergoing salvage TIPS, and hence, pre-emptive TIPS should be considered in these patients. BRTO is an interventional radiologic procedure used in the management of bleeding gastric and ectopic varices. The availability of gastrorenal or splenorenal shunts is required for the BRTO procedure, which helps to reach and obliterate the cardiofundal varices through the femoral or jugular vein approach. The EUS guided coiling and glue injection have shown promising results, and further randomized controlled trials are required to establish their efficacy for refractory variceal bleeding.

10.
Radiol Case Rep ; 17(3): 991-996, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35106111

RESUMEN

This case report describes a neonate with an antenatally diagnosed vascular anomaly of the liver. Ultrasound at birth confirmed an arterioportal fistula communicating the left hepatic artery and an anterior branch of the right portal vein. Computer tomography angiography on day 7 of life redemonstrated the arterioportal fistula and defined the vascular anatomy for potential treatment. Transarterial embolization of the arterioportal fistula was performed at 3 weeks of life using an MVP Microvascular Plug System 3Q (Reverse Medical Corp, Irvine, CA, USA). Intra-procedural angiography showed successful occlusion of the fistula, patency of the portal vein with hepatopetal flow, and patency of the hepatic artery with no signs of arterial or venous thrombosis. There were no intra- or post-procedure complications. Multiple follow-up ultrasounds at 1-13 months showed stable occlusion of the embolized fistula with no evidence of recanalization, with the patient having a normal life and no sequelae. This case illustrates a successful novel approach to manage the rare condition of a solitary hepatic arterioportal fistula in a neonate using the MVP system. Current literature on congenital arterioportal fistulas and the MVP system is reviewed.

11.
Biomater Biosyst ; 8: 100063, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36824373

RESUMEN

One of the major aims of bio-engineering tissue equivalents in vitro is to create physiologically relevant culture conditions to accurately recreate the cellular microenvironment. This often includes incorporation of factors such as the extracellular matrix, co-culture of multiple cell types and three-dimensional culture techniques. These advanced techniques can recapitulate some of the properties of tissue in vivo, however fluid flow is a key aspect that is often absent. Fluid flow can be introduced into cell and tissue culture using bioreactors, which are becoming increasingly common as we seek to produce increasingly accurate tissue models. Bespoke technology is continuously being developed to tailor systems for specific applications and to allow compatibility with a range of culture techniques. For effective perfusion of a tissue culture many parameters can be controlled, ranging from impacts of the fluid flow such as increased shear stress and mass transport, to potentially unwanted side effects such as temperature fluctuations. A thorough understanding of these properties and their implications on the culture model can aid with a more accurate interpretation of results. Improved and more complete characterisation of bioreactor properties will also lead to greater accuracy when reporting culture conditions in protocols, aiding experimental reproducibility, and allowing more precise comparison of results between different systems. In this review we provide an analysis of the different factors involved in the development of benchtop flow bioreactors and their potential biological impacts across a range of applications.

12.
J Vasc Surg Venous Lymphat Disord ; 10(3): 617-625, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34271247

RESUMEN

OBJECTIVE: Primary leiomyosarcoma of the inferior vena cava (IVC) is best managed with surgical resection when technically feasible. However, consensus is lacking regarding the best choice of conduit and reconstruction technique. The aim of the present multicenter study was to perform a comprehensive assessment through the VLFDC (Vascular Low Frequency Disease Consortium) to determine the most effective method for caval reconstruction after resection of primary leiomyosarcoma of the IVC. METHODS: A multicenter, standardized database review of patients who had undergone surgical resection and reconstruction of the IVC for primary leiomyosarcoma from 2007 to 2017 was performed. The demographics, periprocedural details, and postoperative outcomes were analyzed. RESULTS: A total of 92 patients (60 women and 32 men), with a mean age of 60.1 years (range, 30-88 years) were treated. Metastatic disease was present in 22%. The tumor location was below the renal veins in 49 (53%), between the renal and hepatic veins in 52 (57%), and above the hepatic veins in 13 patients (14%). The conduits used for reconstruction included ringed polytetrafluoroethylene (PTFE; n = 80), nonringed PTFE (n = 1), Dacron (n = 1), autogenous vein (n = 1), bovine pericardium (n = 4), and cryopreserved tissue (n = 5). Complete R0 resection was accomplished in 73 patients (79%). In-hospital mortality was 2%, with a median length of stay of 8 days. The primary patency of PTFE reconstructed IVCs was 97% and 92% at 1 and 5 years, respectively, compared with 73% at 1 and 5 years for the non-PTFE reconstructed IVCs. The overall 1-, 3-, and 5-year survival for the entire cohort were 94%, 86%, and 65%, respectively CONCLUSIONS: The findings from our multi-institutional study have demonstrated that complete en bloc resection of IVC leiomyosarcoma with vascular surgical reconstruction in selected patients results in low perioperative mortality and is associated with excellent long-term patency. A ringed PTFE graft was the most commonly used conduit for caval reconstruction, yielding excellent long-term primary patency.


Asunto(s)
Implantación de Prótesis Vascular , Leiomiosarcoma , Animales , Bovinos , Femenino , Humanos , Leiomiosarcoma/diagnóstico por imagen , Leiomiosarcoma/cirugía , Masculino , Persona de Mediana Edad , Politetrafluoroetileno , Estudios Retrospectivos , Resultado del Tratamiento , Vena Cava Inferior/diagnóstico por imagen , Vena Cava Inferior/patología , Vena Cava Inferior/cirugía
13.
Mater Today Bio ; 12: 100172, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34901822

RESUMEN

The use of vaginal surgical mesh to treat pelvic organ prolapse (POP) has been associated with high rates of mesh-related complications. In the present study, we prepared new kinds of meshes based on bacterial cellulose (BC) and collagen-coated BC (BCCOL) using a laser cutting method and perforation technique. The mechanical properties of pre-implanted BC meshes, including breaking strength, suture strength and rigidity, were equal to or exceeded those of available clinically used polypropylene meshes. An in vitro cellular assay revealed that BCCOL meshes exhibited enhanced biocompatibility by increasing collagen secretion and cell adhesion. Both BC and BCCOL meshes only caused weak inflammation and were surrounded by newly formed connective tissue composed of type I collagen after implantation in a rabbit subcutaneous model for one week, demonstrating that the novel mesh is fully biocompatible and can integrate into surrounding tissues. Furthermore, a long-term (ninety days) ewe vaginal implantation model was used to evaluate foreign body reactions and suitability of BC and BCCOL meshes as vaginal meshes. The results showed that the tissue surrounding the BC meshes returned to its original physiology as muscle tissue, indicating the excellent integration of BC meshes into the surrounding tissues without triggering severe local inflammatory response post-implantation. The collagen coating appeared to induce a chronic inflammatory response due to glutaraldehyde remnants. The present exploratory research demonstrated that the developed BC mesh might be a suitable candidate for treating POP.

14.
JTCVS Tech ; 9: 111-120, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34647077

RESUMEN

OBJECTIVE: To study the outcomes of a novel modified pulmonary artery banding (mPAB) technique used for staged repair of a subset of patients with complex transposition physiology. METHODS: A total of 13 patients who underwent mPAB during their staged repair (biventricular repair [BVR], n = 6) or palliation (1-1/2 repair, n = 1; univentricular repair [UVR], n = 6) from 2004 to 2020 were studied retrospectively. A restrictive interposition graft was used to reconstruct the main PA between the pulmonary root and the distal pulmonary confluence, functioning as a mPAB. Twelve of the 13 patients (92.3%) underwent a concurrent arterial switch operation (ASO), of which 6 were palliative ASOs for 1-1/2 repair (n = 1) or UVR (n = 5). Patient weight and cardiac anatomy determined the size of interposition graft. RESULTS: The disease spectrum included dextro transposition of the great arteries (d-TGA) with multiple ventricular septal defects (VSDs) (n = 4), Taussig-Bing anomaly (n = 3), d-TGA with VSD and hypoplastic right ventricle (RV) (n = 3), double-inlet left ventricle with l-TGA (n = 2), and congenitally corrected TGA with double-outlet RV (n = 1). The Lecompte procedure was performed in 10 patients. Predischarge echocardiography revealed a band gradient of 61 mm Hg (interquartile range [IQR], 40-90 mm Hg) for BVR/1-1/2 ventricular repair (n = 7) and 49 mm Hg (IQR, 37-61 mm Hg) for UVR (n = 6). Survival was 100% at a median follow-up of 3.7 years (IQR, 2.6-4.0 years). CONCLUSIONS: The mPAB technique is effective and reproducible for staged BVR or UVR for patients with TGA. It effectively regulates pulmonary blood flow, may reduce neopulmonary root distortion, and eliminates complications associated with band migration in standard PAB.

15.
J Clin Exp Hepatol ; 11(5): 528-530, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34511812
16.
JACC Case Rep ; 3(7): 1064-1068, 2021 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-34317685

RESUMEN

An 82-year-old man with a HeartMate II left ventricular assist device presented with low-flow alarms and cardiogenic shock secondary to left ventricular assist device outflow graft obstruction. Given high risk for redo sternotomy, the heart team decided on percutaneous intervention with peripheral stents, a procedure that is currently limited to case reports. (Level of Difficulty: Advanced.).

17.
Prog Polym Sci ; 118: 101410, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33967350

RESUMEN

Coronavirus disease 2019 (COVID-19) is largely threatening global public health, social stability, and economy. Efforts of the scientific community are turning to this global crisis and should present future preventative measures. With recent trends in polymer science that use plasma to activate and enhance the functionalities of polymer surfaces by surface etching, surface grafting, coating and activation combined with recent advances in understanding polymer-virus interactions at the nanoscale, it is promising to employ advanced plasma processing for smart antiviral applications. This trend article highlights the innovative and emerging directions and approaches in plasma-based surface engineering to create antiviral polymers. After introducing the unique features of plasma processing of polymers, novel plasma strategies that can be applied to engineer polymers with antiviral properties are presented and critically evaluated. The challenges and future perspectives of exploiting the unique plasma-specific effects to engineer smart polymers with virus-capture, virus-detection, virus-repelling, and/or virus-inactivation functionalities for biomedical applications are analysed and discussed.

18.
JTCVS Open ; 8: 263-275, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36004068

RESUMEN

Objective: To evaluate the suture rupture forces of commonly clinically utilized neochord repair techniques to identify the most biomechanically resistant most biomechanically resistant technique. Methods: Several types of neochord techniques (standard interrupted neochordae, continuous running neochordae, and loop technique), numbers of neochordae, and suture calibers (polytetrafluoroethylene CV-3 to CV-6) were compared. To perform the tests, both ends of the neochordae were loaded in a tensile force analysis machine. During the test, the machine applied tension to the neochord until rupture was achieved. The tests were performed 3 times for each variation, and the rupture forces were averaged for statistical analysis. Results: Rupture force was significantly higher for running neochordae relative to interrupted neochordae (P < .01). However, a single rupture in the running technique resulted in failure of the complete neochord system. For both running and interrupted neochordae, a greater number of neochordae as well as a thicker suture caliber significantly increased the neochord rupture force (P < .01). The loop technique ruptured at significantly lower forces compared with the other 2 techniques (P < .01). A greater number of loops did not significantly increase the rupture force of loop neochordae. Observed rupture forces for all techniques were higher than those normally observed in physiologic conditions. Conclusions: Under experimental conditions, the running neochord technique has the best mechanical performance due to an increased rupture force. If using running neochordae, more than 1 independent set of multiple running neochordae are advised (ie, >2 independent sets of multiple running neochordae in each set).

19.
Saudi Dent J ; 32(6): 306-313, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32874071

RESUMEN

OBJECTIVES: This study compared the effects of normal salivary pH, and acidic pH found in patients with poor oral hygiene, on the durability of aesthetic archwire coated with epoxy resin and polytetrafluoroethylene (PTFE). METHODS: The posterior parts of the archwires were sectioned into 20 mm segments (N = 102) and divided among six groups. Four groups were treated with different pH levels and two served as controls. The specimens were immersed in individual test tubes containing 10 ml of artificial saliva adjusted to a pH of 6.75 or 3.5. The tubes were sealed and stored in a 37 °C water bath for 28 days. After 28 days, the specimens were ligated to brackets embedded in an acrylic block and subjected to mechanical stress using an electronic toothbrush for 210 s. The specimens were photographed, and images were measured for coating loss using AutoCAD® software. Surface morphology was observed using a scanning electron microscope (SEM). RESULTS: Significant coating loss (p < 0.001) was found in the epoxy resin groups, regardless of pH value, but not in the PTFE groups. The acidic pH caused epoxy resin layer coating loss by twice as much as normal pH. SEM revealed existing manufacturing defects on the as-received epoxy resin coating, whereas the retrieved epoxy resin demonstrated rupture, roughness, and coating loss in multiple locations. SIGNIFICANCE: Epoxy resin coatings demonstrate poor durability in acidic environments. This condition is worsened by the existing manufacturing defects found on as-received archwires. Hence, archwires coated with epoxy resin are not recommended in patients with poor oral hygiene.

20.
Mater Today Bio ; 5: 100038, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32211604

RESUMEN

Valvular heart diseases (VHD) are a major health burden, affecting millions of people worldwide. The treatments for such diseases rely on medicine, valve repair, and artificial heart valves including mechanical and bioprosthetic valves. Yet, there are countless reports on possible alternatives noting long-term stability and biocompatibility issues and highlighting the need for fabrication of more durable and effective replacements. This review discusses the current and potential materials that can be used for developing such valves along with existing and developing fabrication methods. With this perspective, we quantitatively compare mechanical properties of various materials that are currently used or proposed for heart valves along with their fabrication processes to identify challenges we face in creating new materials and manufacturing techniques to better mimick â€‹the performance of native heart valves.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...