Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Europace ; 26(9)2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39166530

RESUMEN

AIMS: Pulsed-field ablation (PFA) is an emerging technology to perform pulmonary vein isolation (PVI). Initial data demonstrated high safety and efficacy. Data on long-term PVI durability and reconduction patterns in comparison to established energy sources for PVI are scarce. We compare findings in repeat ablation procedures after a first PFA to findings in repeat ablation procedures after a first cryoballoon ablation (CBA) based PVI. METHODS AND RESULT: A total of 550 consecutively enrolled patients underwent PFA or CBA index PVI. Repeat ablations in patients with symptomatic atrial arrhythmia recurrences were analysed. A total of 22/191 (12%) patients after index PFA-PVI and 44/359 (12%) after CBA-PVI underwent repeat ablation. Reconduction of any pulmonary vein (PV) was detected by multipolar spiral mapping catheter at each PV with careful evaluation of PV potentials and by 3D-mapping in 16/22 patients (73%) after PFA-PVI and in 33/44 (75%) after CBA-PVI (P = 1.000). Of 82 initially isolated PVs after PFA-PVI, 31 (38%) were reconducting; of 169 isolated PVs after CBA-PVI, 63 (37%) were reconducting (P = 0.936). Clinical atrial tachycardia occurred similarly in patients after PFA (5/22; 23%) and CBA (7/44; 16%; P = 0.515). Roof lines were set more often after PFA- (8/22; 36%) compared with CBA-PVI (5/44; 11%; P = 0.023). Repeat procedure duration [PFA: 87 (76, 123) min; CBA: 93 (75, 128) min; P = 0.446] was similar and fluoroscopy time [PFA: 11 (9, 14) min; CBA: 11 (8, 14) min; P = 0.739] equal between groups at repeat ablation. CONCLUSION: During repeat ablation after previous PFA- or CBA-based PVI, electrical PV-reconduction rates and patterns were similar.


Asunto(s)
Fibrilación Atrial , Criocirugía , Venas Pulmonares , Recurrencia , Reoperación , Humanos , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Criocirugía/métodos , Criocirugía/efectos adversos , Criocirugía/instrumentación , Masculino , Femenino , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Persona de Mediana Edad , Anciano , Reoperación/estadística & datos numéricos , Resultado del Tratamiento , Ablación por Catéter/métodos , Factores de Tiempo , Potenciales de Acción , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca
2.
J Interv Card Electrophysiol ; 67(2): 379-387, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37776356

RESUMEN

BACKGROUND: Pulsed field ablation (PFA) is a novel method of cardiac ablation where there is insufficient knowledge on the durability and reconnection patterns after pulmonary vein isolation (PVI). The aim of this study was to characterize the electrophysiological findings at time of repeat procedure in real-world atrial fibrillation (AF) patients. METHODS: Patients who underwent a repeat procedure (n=26) for symptomatic recurrent arrhythmias after index first-time treatment with single-shot PFA PVI (n=266) from July 2021 to June 2023 were investigated with 3D high-density mapping and ad-hoc re-ablation by radiofrequency or focal PFA. RESULTS: Index indication for PVI was persistent AF in 17 (65%) patients. The mean time to repeat procedure was 292 ± 119 days. Of the 26 patients (104 veins), complete durable PVI was observed in 11/26 (42%) with a durable vein isolation rate of 72/104 (69%). Two patients (8%) had all four veins reconnected. The posterior wall was durably isolated in 4/5 (80%) of the cases. The predominant arrhythmia mechanism was AF in 17/26 (65%) patients and regular atrial tachycardia (AT) in 9/26 (35%). Reconnection was observed 9/26 (35%) in right superior, 11/26 (42%) in right inferior, 7/26 (27%) in left superior, 5/26 (19%) in left inferior, p=0.31 between veins. The gaps were significantly clustered in the right-sided anterior carina compared to other regions (P=0.009). CONCLUSIONS: Durable PVI was observed in less than half of the patients at time of repeat procedure. No significant difference in PV reconnection pattern was observed, but the gap location was preferentially located at the anterior aspects of the right-sided PVs. Predominant recurrence was AF. More data is needed to establish lesion formation and durability and AT circuits after PFA.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Taquicardia Supraventricular , Humanos , Venas Pulmonares/cirugía , Resultado del Tratamiento , Fibrilación Atrial/cirugía , Taquicardia Supraventricular/cirugía , Ablación por Catéter/métodos , Recurrencia
3.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37539865

RESUMEN

AIMS: The relationship between local unipolar voltage (UV) in the pulmonary vein (PV)-ostia and left atrial wall thickness (LAWT) and the utility of these parameters as indices of outcome after atrial fibrillation (AF) ablation remain unclear. METHODS AND RESULTS: Two-hundred seventy-two AF patients who underwent AF ablation were enrolled. Unipolar voltage of PV-ostia was measured using a CARTO system, and LAWT was measured using computed tomography. The primary endpoint was atrial tachyarrhythmia (ATA) recurrence including AF. The ATA recurrence was documented in 74 patients (ATA-Rec group). The UV and LAWT of the bilateral superior PV roof to posterior and around the right-inferior PV in the ATA-Rec group were significantly greater than in patients without ATA recurrence (ATA-Free group) (P < 0.001). The UV had a strong positive correlation with LAWT (R2 = 0.446, P < 0.001). The UV 2.7 mV and the corresponding LAWT 1.6 mm were determined as the cut-off values for ATA recurrence (P < 0.001, respectively). Multisite LA high UV (HUV, ≥4 areas of >2.7 mV) or multisite LA wall thickening (≥5 areas of >1.6 mm), defined as LA hypertrophy (LAH), was related to higher ATA recurrence. Among 92 LAH patients, 66 had HUV (LAH-HUV) and the remaining 26 had low UV (LAH-LUV), characterized by history of non-paroxysmal AF and heart failure, reduced LV ejection fraction, or enlarged LA. In addition, LAH-LUV showed the worst ablation outcome, followed by LAH-HUV and No LAH (log-rank P < 0.001). CONCLUSION: Combining UV and LAWT enables us to stratify recurrence risk and suggest a tailored ablation strategy according to LA tissue properties.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Apéndice Atrial/cirugía , Taquicardia/etiología , Tomografía Computarizada por Rayos X , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
5.
J Cardiovasc Electrophysiol ; 33(6): 1096-1103, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35304790

RESUMEN

BACKGROUND: Cryoballoon (CB)-based pulmonary vein isolation (PVI) has proven to be as effective as radiofrequency-based ablation. Different ablation protocols took the individual time-to-isolation (TTI) into account aiming at shorter but equally or even more effective freeze cycles. The current study sought to assess the impact of the TTI on PVI durability in patients undergoing a repeat procedure for recurrence of atrial tachyarrhythmia (ATA). METHODS AND RESULTS: In 205 patients with ATA recurrence after previous CB-based PVI, a total of 806 pulmonary veins (PVs) were identified. A total of 126 out of 806 PVs (16%) were previously treated with a TTI-guided ablation (Protocol #1; TTI + 120 s), in 92/806 (11%) PVs TTI was only monitored (m) but fixed freeze cycles were applied (Protocol #2; mTTI) and in 588/806 (73%) a fixed freeze cycle was applied without mTTI. There was no difference in the PV-reconduction rate between the groups (p = .23). The right inferior pulmonary vein (RIPV) showed overall significantly higher reconduction rates compared to the other PVs (RIPV-left inferior PV p < .003, -left superior PV p < .001, -right superior PV p < .013). Twenty-one patients (10%) were demonstrated to have only electrical reconduction of the RIPV, while all other PVs were still electrically isolated. CONCLUSIONS: The TTI-based CB ablation protocol did not show significant differences regarding PV-reconduction rates compared to the other ablation protocols.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Criocirugía/métodos , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
6.
J Cardiovasc Electrophysiol ; 31(9): 2526-2529, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32713018

RESUMEN

Incisional atrial tachycardia (AT) with multiple penetrating points on one surgical incision has not been reported yet. We present a case of incisional AT following mitral valve annuloplasty with a superior transseptal approach, in which two reconduction sites were parts of the reentrant circuit. Radiofrequency ablation at the reconduction site successfully terminated the tachycardia. A total of four penetrating points were found on the incision line, and radiofrequency ablation at these sites was completed. Detailed mapping of possible reconduction sites along the incision line should be performed to avoid further instances of AT following open heart surgery.


Asunto(s)
Ablación por Catéter , Herida Quirúrgica , Taquicardia Supraventricular , Ablación por Catéter/efectos adversos , Humanos , Taquicardia/cirugía , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiología , Taquicardia Supraventricular/cirugía , Resultado del Tratamiento
7.
Circ J ; 84(6): 902-910, 2020 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-32307357

RESUMEN

BACKGROUND: The second-generation cryoballoon (CB2) has demonstrated high procedural efficacy and convincing clinical success rates for pulmonary vein isolation (PVI). Nevertheless, data on the impact of different ablations protocols on durability are limited. The aim was to comparing the durability of PVI following 3 different ablation strategies in patients with recurrence of atrial fibrillation or atrial tachycardia undergoing repeat procedures.Methods and Results:In 192 patients, a total of 751 PVs were identified. All PVs were successfully isolated during index PVI. Thirty-one out of 192 (16%) patients were treated with a bonus-freeze protocol (group 1), 67/192 (35%) patients with a no bonus-freeze protocol (group 2), and 94/192 (49%) patients with a time-to-effect-guided protocol (group 3). Persistent PVI was documented in 419/751 (55.8%) PVs, and in 41/192 (21%) patients, all PVs were persistently isolated. The total rate of PV reconnection was not significantly different between the groups (P=0.134) and the comparison of individual PVs revealed no differences (P-values for RSPV: 0.424, RIPV: 0.541, LSPV: 0.788, LIPV: 0.346, LCPV: 0.865). The procedure times were significantly reduced by omitting the bonus-freeze and applying individualized application times (group 1: 123.4±31.5 min, group 2: 112.9±39.8 min, group 3: 86.67±28.4 min, P<0.001). CONCLUSIONS: Comparing 3 common ablation protocols, no differences for durable PVI were detected. Procedure times were significantly reduced by omitting the bonus-freeze cycle and by applying individualized application times.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial/cirugía , Criocirugía/métodos , Frecuencia Cardíaca , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Criocirugía/efectos adversos , Femenino , Alemania , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Venas Pulmonares/fisiopatología , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Taquicardia Supraventricular/etiología , Taquicardia Supraventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
8.
Europace ; 17(5): 725-31, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25618741

RESUMEN

AIMS: Pulmonary vein isolation (PVI) using the first-generation cryoballoon (CB1) was characterized by a high rate of recovered pulmonary vein (PV) conduction along with a typical conduction gap pattern in patients with recurrent atrial tachyarrhythmia (ATa). Second generation (CB2) enables more uniform freezing. However, the rate of chronic PVI and PV conduction gap pattern is unknown. METHODS AND RESULTS: All patients with ATa recurrence undergoing a second procedure after CB2 or (historical) CB1 PVI (28 mm) were enrolled. In all patients, a left atrial three-dimensional electronatomic reconstruction was performed. The rates of chronic PVI and localization of PV conduction gaps were determined and compared between CB1 and CB2. Antral PV re-isolation was performed using irrigated-tip radiofrequency current energy ablation. Of 206 patients (CB2), 18 patients underwent the repeat procedure after 192 (75:245) days. In 6 of 18 (33%) patients, all PVs were electrically isolated whereas in the remaining 12 patients (66%) at least one PV demonstrated PV reconduction. Of 71 PVs [1 left common PV (LCPV)], 55 PVs (77%) were chronically isolated. The right superior PV (RSPV) was characterized by the lowest rate of chronic PVI (RSPV: 56%, LSPV: 76%, RIPV: 83%, LIPV: 94%, LCPV: 100%). Compared with CB1, CB2 ablation resulted in a significantly higher rate of chronic PVI (CB2: 77% vs. CB1: 32%; P < 0.0001) with the greatest improvement along both inferior PVs. CONCLUSION: Second-generation cryoballoon atrial fibrillation ablation is associated with a high rate of durable PVI in patients with ATa recurrence. The RSPV represents the PV with the greatest risk for left atrium-pulmonary vein reconnection.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía , Venas Pulmonares/cirugía , Taquicardia Supraventricular/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Criocirugía/efectos adversos , Criocirugía/instrumentación , Bases de Datos Factuales , Técnicas Electrofisiológicas Cardíacas , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/fisiopatología , Recurrencia , Reoperación , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...