1.
Eur Heart J Case Rep ; 8(8): ytae396, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39156952

RESUMEN

Background: Annuloplasty ring dehiscence (ARD) after surgical mitral valve repair is a rare complication, which causes recurrent mitral regurgitation (MR) and is associated with adverse outcomes in patients with a prohibitive risk of repeat surgery. However, a patient developed severe MR, when challenging transcatheter edge-to-edge repair (TEER) after surgical ring dehiscence, it should be considering the relative efficacy and safety. Case summary: An 89-year-old man underwent mitral valve repair with an annuloplasty ring for moderate atrial functional MR (AFMR). Post-operative transthoracic echocardiography on Day 7 suggested a dislodged mitral annuloplasty ring and recurrent moderate AFMR. However, the MR developed severely, which led to two hospitalizations for congestive heart failure in the past year. Transoesophageal echocardiography (TOE) was performed carefully to ensure that the TEER clip did not interfere with the dislodged annuloplasty ring. Consequently, only the therapeutic target on the medial side of the A2-P2 region was approached posteriorly behind the peri-ring space, without gripper interference. Discussion: Transcatheter edge-to-edge repair using the G4-MitraClip® system is feasible and safe in patients with recurrent severe AFMR after surgical mitral valve repair concomitant with ARD. Meticulous simulation with pre-operative TOE is one of the crucial steps for successful outcomes.

2.
Artículo en Inglés | MEDLINE | ID: mdl-37486243

RESUMEN

OBJECTIVES: This study evaluated suture tie-down forces and cyclic contractile forces (CCFs) after undersized tricuspid annuloplasty using a hybrid band. METHODS: Downsized tricuspid annuloplasty was planned in adult male sheep using 8 force transducers attached from the septal to the anterior annular areas of the ring (segments 1 and 2, flexible septal; segments 3 and 4, semi-rigid posterior; segments 5 and 6, semi-rigid anterior; segments 7 and 8, flexible anterior). CCFs were analysed at 3 different levels of peak right ventricular pressure (RVP): 30, 50 and 70 mmHg. RESULTS: Eight 5-year-old male Corriedale sheep (average body weight = 66.8 kg) were used. The average suture tie-down force was 4.42 [standard deviation (SD): 2.32] N. When the forces were compared, it was lowest in the flexible anterior area and highest in the flexible septal area (P < 0.001). With the RVP of 30 mmHg, the average CCFs was lowest at segment 3 [0.07 (SD: 0.07) N] and highest at segment 7 [0.15 (SD: 0.08) N]. The CCFs were 0.12 (SD: 0.1) N, 0.09 (SD: 0.12) N, 0.14 (SD: 0.1) N and 0.13 (SD: 0.09) N in the flexible septal, semi-rigid posterior, semi-rigid anterior and flexible anterior parts, respectively (P = 0.208). As the peak RVP increased to 50 and 70 mmHg, the CCFs of each area increased significantly (P < 0.001). Despite this increase, the CCFs remained low (0.1 and 0.3 N), and differences in CCFs between segments and between annular areas showed similar patterns. CONCLUSIONS: The flexible end of the hybrid band reduces the CCFs and might prevent annular tears after ring tricuspid annuloplasty, and the risk of tear would be low even in the septal area.

3.
Eur Heart J Case Rep ; 5(11): ytab433, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34917877

RESUMEN

BACKGROUND: Annuloplasty failure caused by ring dehiscence can lead to trans-ring and para-ring mitral regurgitation (MR). Transcatheter treatments are available for patients at prohibitive risk of surgery. In patients unsuitable for edge-to-edge repair, valve-in-ring (ViR) transcatheter mitral valve (MV) implantation has been described to treat trans-ring or para-ring jets but not both concurrently. CASE SUMMARY: A 78-year-old male presented with severe MR due to dehiscence of a 34 mm Edwards Physio II mitral annuloplasty ring. Transoesophageal echocardiography showed two jets of regurgitation; trans-ring and para-ring. Repair was successfully undertaken with a ViR procedure (29 mm S3 Edwards Lifesciences). DISCUSSION: Patients with failure of MV annuloplasty with trans-ring and para-ring regurgitation can be safely and effectively treated by ViR transcatheter MV implantation.

6.
Eur J Cardiothorac Surg ; 60(2): 411-417, 2021 07 30.
Artículo en Inglés | MEDLINE | ID: mdl-33787880

RESUMEN

OBJECTIVES: This study was conducted to measure suture tie-down forces and evaluate cyclic contractile forces (CCFs) in beating hearts after undersized 3-dimensional (3D) rigid-ring tricuspid valve annuloplasty (TAP). METHODS: Eight force transducers were attached to the 3D rigid TAP ring. Segments 1 to 8 were attached from the mid-septal to anterior-septal commissural area in a counterclockwise order. Two-sizes-down ring TAPs were performed in 6 sheep. Tie-down forces and CCF were recorded and analysed at the 8 annular segments and at 3 levels of peak right ventricular pressure (RVP: 30, 50 and 70 mmHg). RESULTS: The overall average tie-down forces and CCF were 4.34 ± 2.26 newtons (N) and 0.23 ± 0.09 N, respectively. The CCF at an RVP of 30 mmHg were higher at 3 commissural areas (segments 3, 5 and 8) than at the other segments. The increases in the CCF following changes in the RVP were statistically significant only at the 3 commissural areas (P = 0.012). However, mean CCFs remained low at all annular positions (ranges of average CCF = 0.06-0.46 N). CONCLUSIONS: The risk of suture dehiscence after down-sized 3D rigid-ring TAP might be minimal because the absolute forces remained low in all annular positions even in the condition of high RVP. However, careful suturing in the septal annular area and commissures is necessary to prevent an annular tear during a down-sized 3D rigid-ring TAP.


Asunto(s)
Prótesis Valvulares Cardíacas , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Tricúspide , Animales , Diseño de Prótesis , Ovinos , Suturas , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/cirugía
7.
Catheter Cardiovasc Interv ; 97(5): E727-E730, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-32438485

RESUMEN

Recurrent severe primary mitral regurgitation from annuloplasty ring dehiscence is very rare and is associated with adverse outcomes. We present a case where transcatheter edge-to-edge mitral repair with MitraClip was used in high surgical risk patient using a peri-ring approach due to unfavorable anatomy for a conventional intra-ring approach.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Anuloplastia de la Válvula Mitral/efectos adversos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
8.
Eur J Cardiothorac Surg ; 57(2): 300-307, 2020 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-31369069

RESUMEN

OBJECTIVES: Mitral valve (MV) annuloplasty ring dehiscence with subsequent recurrent mitral regurgitation represents an unusual but challenging clinical problem. Incidence, localization and outcomes for this complication have not been well defined. METHODS: From 1996 to 2016, a total of 3478 patients underwent isolated MV repair with ring annuloplasty at the Leipzig Heart Centre. Of these patients, 57 (1.6%) underwent reoperation due to annuloplasty ring dehiscence. Echocardiographic data, operative and early postoperative characteristics as well as short- and long-term survival rates after MV reoperation were analysed. RESULTS: Occurrences of ring dehiscence were acute (<30 days), early (≤1 year) and late (>1 year) in 44%, 33% and 23% of patients, respectively. Localization of annuloplasty ring dehiscence was found most frequently in the P3 segment (68%), followed by the P2 (51%) and the P1 segments (47%). The 30-day mortality rate and 1- and 5-year survival rates after MV reoperation were 2%, 89% and 74%, respectively. During reoperation, MV replacement was performed in 38 (67%) and MV re-repair in 19 (33%) patients. CONCLUSIONS: Annuloplasty ring dehiscence is clinically less common, localized more frequently on the posterior annulus and occurs mostly acutely or early after MV repair. MV reoperation can be performed safely in such patients.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Incidencia , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Anuloplastia de la Válvula Mitral/efectos adversos , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/cirugía , Reoperación , Resultado del Tratamiento
9.
J Thorac Cardiovasc Surg ; 159(5): 1766-1774.e2, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31272749

RESUMEN

OBJECTIVE: The study objective was to develop a novel annuloplasty ring with regional flexibility and assess its suture force dynamics in healthy ovine subjects compared with fully rigid or fully flexible rings. METHODS: Materially heterogeneous rings were created with rigid anterior and posterior, and flexible commissural segments. These rings were created to match the geometry of the Profile 3D ring (Medtronic, Minneapolis, Minn). Each ring was instrumented with 10 force transducers to measure cyclic suture forces (FC) and undersized annuloplasty was performed in 6 healthy ovine subjects. Each FC was recorded and examined for cardiac cycles reaching a maximum left ventricular pressure of 100, 125, and 150 mm Hg. FC was compared with previously reported values from fully rigid Profile 3D and fully flexible prototype rings. RESULTS: Relative to the fully rigid ring, the heterogeneous ring exhibited 48% reduction in FC at its commissural (rigid vs heterogeneous: 1.80 ± 0.94 N vs 0.95 ± 0.52 N; P < .001) and 32% reduction in posterior (1.90 ± 0.92 N vs 1.29 ± 0.91 N; P < .001) regions, but not in its anterior region (2.45 ± 1.21 N vs 2.23 ± 1.22 N; P = .279). Relative to the fully flexible ring, the heterogeneous ring exhibited no significant differences in FC in any region. CONCLUSIONS: The reduced FC of the heterogeneous ring relative to the fully rigid ring suggests a promising approach to reduce suture loading while preserving the annular remodeling capability of fully rigid rings. Future studies in diseased subjects are necessary to explore repair effectiveness of this ring.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Anuloplastia de la Válvula Mitral/instrumentación , Válvula Mitral/cirugía , Diseño de Prótesis , Animales , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Ensayo de Materiales , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Anuloplastia de la Válvula Mitral/efectos adversos , Modelos Animales , Docilidad , Oveja Doméstica , Estrés Mecánico
11.
Eur J Cardiothorac Surg ; 51(5): 836-843, 2017 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-28175268

RESUMEN

OBJECTIVES: Investigate myocardial stress adaptation and remodelling capacity of a rigid and semi-rigid mitral annuloplasty ring. METHODS: The annuloplasty rings were characterized in vitro in a mechanical setup with tensile and compressive forces from 0 to 3 N. The rings were tested with and without fixation of the ring to imitate the effect of annular implantation. In vivo measurements were performed with 21 porcine animals randomized into: A no ring group, a rigid ring group (Classic Annuloplasty Ring TM , Edwards Lifesciences) and a semi-rigid ring group (Physio I Annuloplasty Ring, Edwards Lifesciences). The rings were implanted together with a force transducer and sonomicrometry was used for geometry measurements. RESULTS: The flexibility range of the semi-rigid ring was 7.6 and 2.4 mm in the septal-lateral and commissural direction, respectively. With fixation the flexibility was reduced to 1.0 and 0.6 mm, similar to the rigid ring without fixation. In vivo measurements indicated that the rigid and semi-rigid rings equally restrict the annular movement. Septal-lateral flexibility of the semi-rigid ring was not observed. Both rings induced force absorption in the ring and sutures due to the annular fixation. The absorbed forces were significantly lower for the semi-rigid ring in the posterior segment and septal-lateral direction. CONCLUSIONS: This study demonstrates the importance of correct fixation when characterizing annuloplasty rings. The annular movement of the semi-rigid ring was similar to the rigid ring when implanted at the mitral annulus as confirmed in vitro . Despite this the semi-rigid ring demonstrated a favourable stress adaptation which could potentially decrease the risk of ring dehiscence.


Asunto(s)
Prótesis Valvulares Cardíacas , Anuloplastia de la Válvula Mitral/instrumentación , Válvula Mitral/fisiología , Válvula Mitral/cirugía , Animales , Fenómenos Biomecánicos , Corazón/fisiología , Docilidad , Diseño de Prótesis , Estrés Mecánico , Porcinos
12.
J Investig Med High Impact Case Rep ; 2(2): 2324709614538822, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-26425611

RESUMEN

Mitral annular calcification (MAC) is often a result of the accumulation of lipids around the annulus, which can lead to degeneration and calcification of the valve. Multiple risk factors have been associated with the progression of MAC and life-threatening complications such as the early mitral valve annuloplasty dehiscence. Our case describes the different risk factors for annuloplasty dehiscence in a patient with severe MAC, as well as the importance of its early recognition intraoperatively with 3D transesophageal echocardiography.