Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.294
Filtrar
1.
Epilepsy Behav ; 159: 110014, 2024 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-39236374

RESUMEN

PURPOSE: To analyze the characteristics of cerebral blood flow changes of poor sleep quality in people with epilepsy(PWE). METHODS: 90 PWE treated in The General Hospital of Ningxia Medical University from December 2021 to September 2023 were divided into poor sleep quality group (PSQG) and good sleep quality group (GSQG) according to the Chinese version of the Pittsburgh Sleep Quality Index (CPSQI), to compare the differences in cerebral perfusion between the two groups of patients, so as to summarize the characteristics of cerebral blood flow changes of poor sleep quality in PWE. RESULTS: The positive rate of interictal single-photon emission computed tomography/computed tomography (SPECT/CT) was 76.7 %(69/90), which showed localized cerebral hypoperfusion. There was no statistical difference between the two groups of PSQG (N=29) and GSQG (N=61) in terms of the positive rate of SPECT/CT, the number of hypoperfusion foci, and the range of hypoperfusion foci. In PSQG and GSQG, 9 patients(31.0 %) and 6 patients(9.8 %) showed hypoperfusion in the right parietal lobe, respectively, and the difference between the two groups was statistically significant (P=0.017). There was no statistical difference the rate of the interictal epileptiform discharges (IEDs) and the brain area of IEDs in electroencephalography(EEG) between the two groups. CONCLUSION: SPECT/CT of poor sleep quality in PWE demonstrated hypoperfusion in the right parietal lobe.

2.
Knee ; 51: 58-64, 2024 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-39236638

RESUMEN

BACKGROUND: An open wedge high tibial osteotomy (OWHTO) may lead to gait alteration, which change the contact loading in the contralateral knee, while clear evidence about the impact on contralateral knee still lacks. The purpose of the current study was to evaluate the change in scintigraphic uptake using SPECT-CT in the medial compartment of the contralateral knee following OWHTO. METHODS: Contralateral radiographic measurements were performed for patients with medial osteoarthritis and varus malalignment of >5° treated with OWHTO in this retrospective analysis. The medial compartmental changes according to SPECT/CT analysis before and 1-year after OWHTO were evaluated on the contralateral side. RESULTS: The study comprised 72 patients. The mean preoperative mechanical femorotibial angle was a mean varus of 7.6° (range, 5.1° - 13.0°), corrected to a mean valgus of 2.5° (range, 1.9° - -8.5°) postoperatively. The average grading of the scintigraphic uptakes in the medial compartment of the contralateral knee was significantly decreased 1 year postoperatively than after the surgery (from 2.8 ± 0.4 to 2.1 ± 0.6, p < 0.001). Measurable differences in varus alignment on radiographs of the contralateral limb were identified. The preoperative mechanical axis value decreased from 8.0° ± 2.4° to 6.7° ± 2.6° at the 3-month postoperative visit (p = 0.011). The overall decrease in varus alignment remained at the 2-year final postoperative follow-up. CONCLUSION: Alignment correction by OWHTO results in reducing scintigraphy uptakes in medial compartment and improvement in mechanical alignment of the contralateral knee. LEVEL OF EVIDENCE: Therapeutic Level IV.

3.
BMC Cancer ; 24(1): 982, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-39118101

RESUMEN

BACKGROUND: Prompt and accurate diagnosis of prostate cancer (PCa) is of paramount importance for effective treatment planning. While Gallium-68 labeled prostate-specific membrane antigen (PSMA) positron emission tomography (PET)/computed tomography (CT) has proven efficacy in detecting PCa, limited availability poses challenges. As a potential alternative, [99mTc]Tc-PSMA single photon emission computed tomography (SPECT)/computed tomography (CT) holds promise. This systematic review and meta-analysis aimed to evaluate the diagnostic value of [99mTc]Tc-PSMA SPECT/CT for prostate cancer. METHODS: A comprehensive search of PubMed, Cochrane, EMBASE, Scopus, Ovid, and Web of Science databases was conducted until July 2024. Sensitivity and specificity data were extracted to assess the diagnostic accuracy of [99mTc]Tc-PSMA SPECT/CT, while the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool was used to evaluate study quality. Statistical analyses were performed using STATA 18, with MetaDisc 1.4 employed to detect threshold effects. Diagnostic accuracy indicators, including sensitivity, specificity, diagnostic odds ratio (DOR), negative likelihood ratio (LR-), and positive likelihood ratio (LR+), were pooled. The area under the curve (AUC) of the combined model was calculated using summary receiver-operating characteristic (SROC) curves. RESULTS: Seven studies meeting the inclusion criteria were identified from an initial pool of 1467 articles, with no publication bias observed. The pooled sensitivity, specificity, and AUC of [99mTc]Tc-PSMA SPECT/CT were found to be 0.89 (95% CI, 0.84-0.93), 0.92 (95% CI, 0.67-0.99), and 0.93 (95% CI, 0.90-0.95), respectively. Additionally, the comprehensive diagnostic odds ratio, diagnostic score, positive likelihood ratio, and negative likelihood ratio were calculated as 95.24 (95% CI, 17.30-524.41), 4.56 (95% CI, 2.85-6.26), 11.35 (95% CI, 2.31-55.71), and 0.12 (95% CI, 0.08-0.18), respectively. CONCLUSIONS: In conclusion, our findings demonstrate that [99mTc]Tc-PSMA SPECT/CT exhibits favorable diagnostic performance for prostate cancer and can provide valuable supplementary information, particularly in regions and settings where [68Ga]Ga-PSMA PET/CT availability is limited, such as remote areas. These results highlight the potential of [99mTc]Tc-PSMA SPECT/CT as a valuable tool in the diagnosis and management of prostate cancer, warranting further investigation and validation in larger patient cohorts.


Asunto(s)
Neoplasias de la Próstata , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Humanos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Masculino , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Sensibilidad y Especificidad , Radiofármacos , Compuestos de Organotecnecio , Curva ROC , Tecnecio , Glutamato Carboxipeptidasa II/metabolismo , Antígenos de Superficie
4.
Clin Case Rep ; 12(8): e9289, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39114846

RESUMEN

When the chest radiograph of a young patient shows lung hyperlucency, it is important to obtain a detailed clinical history of any previous episodes of childhood infection. Previous chest radiographs should be reviewed to determine whether the condition is congenital or acquired, and thus assist in a diagnosis of SJMS.

5.
Foot Ankle Int ; : 10711007241263797, 2024 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-39095986

RESUMEN

BACKGROUND: Asymmetric joint load is the main cause of development of ankle osteoarthritis (OA). Realignment surgery aims to transfer ankle joint load from the degenerative area toward the uninvolved area. Determination of the optimal shift is still challenging. When the degenerative area is correlated to the ankle joint mechanical axis establishing an optimal target angle for corrective surgery may become more feasible. The primary aim of our study was to investigate if the area of ankle joint activation on single-photon emission computed tomography and conventional computed tomography (SPECT/CT) imaging correlates with the mechanical ankle joint axis point (MAJAP). METHODS: In this cross-sectional study, patients 18 years or older with symptomatic asymmetric ankle OA and a hip-to-calcaneus long leg view with SPECT/CT of the affected ankle were eligible for inclusion. Primary outcome was MAJAP divided into 3 alignment categories (medial shift, neutral, lateral shift). SPECT/CT activation was determined in 8 different areas of the ankle joint. A Spearman rho correlation coefficient was calculated to investigate the relationship between the alignment categories and SPECT/CT activation in the 8 areas. RESULTS: Forty-nine patients (mean age 58.8 [SD 10.0] years) with 52 ankles with moderate to severe asymmetric OA were included. A significantly (Spearman rho -0.379 [P = .006] and Spearman rho -0.279 [P = .045]) higher proportion of ankles with radioisotope uptake in the anteromedial ankle joint areas (zones 1 and 5) was seen in the medial shift category. A significantly (Spearman rho .312 (P = .025)) higher proportion of ankles with radioisotope uptake in the anterolateral ankle joint area (zone 8) was seen in the lateral shift category. CONCLUSION: We found in this patient group that the area of SPECT/CT uptake in asymmetric ankle OA was associated to MAJAP measured on hip-to-calcaneus weightbearing views, although the strength of the correlation is weak to moderate. Consequently, nonweightbearing metabolic SPECT/CT radiotracer uptake has the potential to help determine the area to unload in ankle joint-preserving alignment surgery.

6.
World J Nucl Med ; 23(3): 176-179, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39170839

RESUMEN

Aim The imaging of Meckel's diverticulum (MD) is based of accumulation of Tc-99m pertechnetate in the ectopic gastric mucosa (EGM) content. Although the diagnostic accuracy of this imaging modality is high, there are some overlap patients with coexisting gastrointestinal bleeding and false positive causes hampering diagnostic power. The aim of this study was to evaluate the possible contribution of single-photon emission computed tomography/computed tomography (SPECT/CT) in EGM-MD diagnosis and to determine the indication of this additional imaging modality. Materials and Methods Fifty-two pediatric patients (24 girls, 28 boys; mean age: 8.06 ± 5.22 years old) who have suspicion of MD and referred for scintigraphy were evaluated retrospectively. Additional SPECT/CT were performed to selected five cases among the group. The results of the scintigraphy as well as SPECT/CT were compared with endoscopy, pathology, and/or follow-up results. Results There were 9 patients with equivocal study results, 12 positive results, and the others were considered negative MD scintigraphy. One patient was out of follow-up and 10 patients underwent surgery. Only one single patient was negative during surgery but scintigraphy was also negative. The diagnostic sensitivity, specificity, and accuracy were 100, 95, and 96%, respectively. Among five patients with SPECT/CT results one patient was diagnosed by only SPECT/CT who had EGM in duplication cyst, one equivocal patient was diagnosed as descending colon bleeding, and one patient's lesion was clearly delineated by SPECT/CT. Conclusion SPECT/CT has clear advantage over standard planar scintigraphy imaging in EGM-MD determination. This modality might decrease equivocal and false positive results but this issue has to be addressed with further studies.

7.
Thorac Cancer ; 2024 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-39140206

RESUMEN

BACKGROUND: Lymph node (LN) metastasis is a significant prognostic factor for esophageal squamous cell carcinoma (ESCC), and there are no satisfactory methods for accurately predicting metastatic LNs. The present study aimed to assess the efficacy of 99mTc-3PRGD2 single-photon emission computed tomography (SPECT)/computed tomography (CT) for diagnosing metastatic LNs in ESCC. METHODS: A total of 15 enrolled patients with ESCC underwent 99mTc-3PRGD2 SPECT/CT and 18F-fluorodeoxyglucose positron emission tomography-computed tomography (18F-FDG PET/CT) examinations preoperatively. High-definition bone carving reconstruction technology (HD-xSPECT Bone) was applied to quantitatively assess the LN's SUVmax via SPECT/CT. The two methods were compared for diagnosing metastatic LNs with pathology as the gold standard. RESULTS: Among 15 patients, 23 metastatic lymph node stations (mLNSs) were predicted by SPECT/CT, with a mean SUVmax of 2.71 ± 1.34, of which 15 were pathologically confirmed; 32 mLNSs were predicted by PET/CT with a mean SUVmax of 4.41 ± 4.02, of which 17 were pathologically confirmed. The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of SPECT/CT for diagnosing metastatic LNs were 62.50%, 91.30%, 85.34%, 65.22%, and 90.32%, respectively, and those of PET/CT were 70.83%, 83.70%, 81.03%, 53.13%, and 91.67%, respectively. There was no significant difference in sensitivity (p = 0.061) or specificity (p = 0.058) between the two methods. The AUCSPECT/CT was 0.816 and the SUVmax threshold was 2.5. CONCLUSION: 99mTc-3PRGD2 SPECT/CT might be an effective method for diagnosing metastatic LNs in ESCC, especially in combination with HD-xSPECT Bone. The diagnostic efficiency of this method was noninferior to that of 18F-FDG PET/CT. The SUVmax threshold of 2.5 showed the highest agreement with the pathology findings.

8.
Ann Nucl Med ; 2024 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-39154304

RESUMEN

OBJECTIVE: This study aimed to identify a relatively robust SUV for guiding clinical practice through quantitative measurement and comparison of various normalization methods based on the SUV of 99mTc-MDP in the normal spine and pelvis using an integrated SPECT/CT scanner. METHODS: Between June 2017 and September 2019, a total of 500 oncology patients (mean age, 60.9; men, 66.0%) who underwent bone SPECT/CT scans with 99mTc-MDP were enrolled in this retrospective study. The mean SUV (SUVmean) of 4962 spinal and pelvic bones was calculated based on the patients' body weight (BW), lean body mass (LBM), bone mineral content (BMC), body surface area (BSA), and body mass index (BMI), defined as SUVbw, SUVlbm, SUVbmc, SUVbsa, and SUVbmi, respectively. The coefficients of variation (CoVs) of the aforementioned parameters were compared, and the correlation and multiple linear regression analyses were used to compare the extent to which these parameters were affected by sex, age, height, weight, BMI, and CT values. RESULTS: The average SUVs in the normal spine and pelvis displayed a relatively wide variability: 4.573 ± 1.972 for SUVbw, 3.555 ± 1.517 for SUVlbm, 0.163 ± 0.071 for SUVbmc, 0.124 ± 0.052 for SUVbsa, and 1.668 ± 0.732 for SUVbmi. In general, SUVbsa had relatively lowest CoV (42.1%) in all vertebrae and pelvis compared with other SUVs. For correlation analyses, all SUVs displayed weak but significant correlations with age and CT values. For regression analyses, SUVbsa was influenced only by age, BMI, and CT values independently. The effects of these variables on SUVbsa were all smaller than those on conventional SUVbw. CONCLUSIONS: The SUVs of 99mTc-MDP in normal bone derived from quantitative bone SPECT/CT could serve as a reference for evaluating tumor bone metastasis, but it should be assessed on a site-specific basis. SUVbsa exhibited superior robustness among all the SUV normalization variations, indicating potential clinical applications.

9.
EJNMMI Phys ; 11(1): 71, 2024 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-39090481

RESUMEN

INTRODUCTION: This study aims to evaluate the use of CT-based whole kidney parenchyma (WKP) segmentation in 177Lu-DOTATATE dosimetry. Specifically, it investigates whether WKP volumes change during treatment and evaluates the accuracy of applying a single delineated WKP volume for dosimetry. Furthermore, it aims to determine the cause of WKP volume changes-whether caused by radiation or amino acid infusion-by comparing them with spleen volume changes as a marker for radiation-induced alterations. METHODS: SPECT/CT images of 18 patients were acquired over the abdomen approximately 4 h (h) (D0), 24 h (D1), 48 h (D2) and 168 h (D7) post-administration of 177Lu-DOTATATE. CT guided WKP volumes were measured before (baseline) and during treatment. Kidney activity concentrations at each time point were derived from CT-segmented WKP overlaid on SPECT scans. The accuracy of using WKP segmentation from a single CT for all time points was assessed against the gold standard of segmenting each WKP individually. Time-integrated activity calculations were based on a tri-exponential curve fit of the kidney activity concentration over time. Kidney absorbed doses were estimated under the assumption of local energy deposition. Additionally, the impact of various partial volume correction methods on dosimetry was evaluated. RESULTS: Whole-kidney parenchyma (WKP) volumes, ranging from 31 to 243 mL, showed a gradual increase from baseline (mean ± SD = 130.6 ± 46.1 mL) at the initial time points D0 (138.5 ± 44.7 mL) and D1 (139.4 ± 41.6 mL), followed by a slight decrease at D2 (132.8 ± 44.5 mL) and a further decrease at D7 (129.2 ± 42.7 mL). The volume increase at D0 and D1 was statistically significant. Spleen volume did not change during treatment, suggesting that amino acid infusion rather than irradiation effects caused WKP volume changes. Bland-Altman analysis revealed WKP volume biases of 8.77% (D0 vs. BL), 10.77% (D1 vs. BL), 1.10% (D2 vs. BL), and 1.10% (D7 vs. BL), with corresponding uncertainties of 24.4%, 23.6%, 25.4%, and 25.4%, respectively. When WKP segmentation from a single CT is applied across all SPECTs, these WKP volume changes could overestimate the activity concentration and mean absorbed doses up to 4.3% and 2.5%, respectively. The absorbed dose uncertainties using a recovery coefficient (RC) of 0.85 for single-time-point WKP delineation increase the absorbed dose uncertainty by 4% compared to the use of patient-specific RCs and time specific segmentation of WKP volumes. CONCLUSIONS: Kidney volume exhibited significant variation form D0 to D7, affecting the precision of dosimetry calculation, primarily due to errors in whole-kidney parenchyma (WKP) delineation. Notably, using WKP segmentation from a single CT scan applied to sequential SPECT images introduce further uncertainty and may lead to an overestimation of the absorbed dose. The fluctuations in kidney volume are most likely attributable to amino acid infusion.

10.
EJNMMI Phys ; 11(1): 74, 2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39177939

RESUMEN

BACKGROUND: Unilateral condylar hyperplasia (UCH) of the mandible is a rare condition characterized by asymmetric growth of the mandibular condyles. Bone scintigraphy with SPECT(/CT) is commonly used to diagnose UCH and guide treatment. Still, varying results have been reported using the traditional threshold of 55%:45% in relative tracer uptake. While absolute quantification of uptake on SPECT/CT could improve results, optimal correction and reconstruction settings are currently unknown. METHODS: Three anthropomorphic phantoms representing UCH were developed from patient CT volumes and produced using 3D printing technology. Fillable spherical inserts of different sizes (Ø: 8-15 mm) were placed in the condylar positions representing symmetrical and asymmetrical distributions. Recovery coefficients were determined for SPECT/CT using various reconstruction corrections, including attenuation and scatter correction (ACSC), resolution modeling (RM), and partial volume correction (PVC) using phantom measurements. Uptake ratios between condyles and condyle to clivus were evaluated. Finally, the impact of these correction techniques on absolute activity and diagnostic accuracy was assessed in a retrospective patient cohort for the diagnostic threshold of 55%:45%. RESULTS: The activity was only partially recovered in all spherical inserts (range: 22.5-64.9%). However, RM improved relative recovery by 20.2-62.3% compared to ACSC. In the symmetric phantoms, the 95% confidence interval (CI) of condyle ratios included the diagnostic threshold (57.6%:42.4%) for UCH when using ACSC potentially leading to false positives, but not for ACSCRM datasets. Partial volume corrections coefficients from the NEMA IQ phantom was positionally dependent, with improvements seen performing PVC using coefficients derived from anthropomorphic phantoms. Retrospective application in a patient cohort showed only a weak linear correlation (R²: 0.25-0.67) and large limits of agreement (9.6-12.5%) between different reconstructions. Up to 44% of patients were reclassified using the 55%:45% threshold. Using clinical outcome data, ACSCRM had highest sensitivity (91%; 95% CI 59-100%) and specificity (66%; 95% CI 47-81%), significantly improving specificity (P = 0.038). CONCLUSIONS: Anthropomorphic phantoms were shown to be essential in determining optimal settings for acquisition, reconstruction, and analysis. SPECT/CT reconstructions with attenuation and scatter correction and resolution modeling are recommended and could improve specificity when using the 55%:45% threshold to assess condylar growth.

11.
Ann Nucl Med ; 2024 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-39179897

RESUMEN

AIM: CT images can identify structural and opacity alterations of the lungs while nuclear medicine's lung perfusion studies show the homogeneity (or lack of) of blood perfusion on the organ. Therefore, the use of SPECT/CT in lung perfusion scintigraphies can help physicians to assess anatomical and functional alterations of the lungs and to differentiate between acute and chronic disease. OBJECTIVE: To develop a computer-aided methodology to quantify the total global perfusion of the lungs via SPECT/CT images and to compare these results with parenchymal alterations obtained in CT images. METHODS: 39 perfusion SPECT/CT images collected retrospectively from the Nuclear Medicine Facility of Botucatu Medical School's Clinics Hospital in São Paulo, Brazil, were analyzed. Anatomical lung impairments (emphysema, collapsed and infiltrated tissue) and the functional percentage of the lungs (blood perfusion) were quantified from CT and SPECT images, with the aid of the free, open-source software 3D Slicer. The results obtained with 3D Slicer (3D-TGP) were also compared to the total global perfusion of each patient's found on their medical report, obtained from visual inspection of planar images (2D-TGP). RESULTS: This research developed a novel and practical methodology for obtaining lungs' total global perfusion from SPECT/CT images in a semiautomatic manner. 3D-TGP versus 2D-TGP showed a bias of 7% with a variation up to 67% between the two methods. Perfusion percentage showed a weak positive correlation with infiltration (p = 0.0070 and ρ = 0.43) and collapsed parenchyma (p = 0.040 and ρ = 0.33). CONCLUSIONS: This research brings meaningful contributions to the scientific community because it used a free open-source software to quantify the lungs blood perfusion via SPECT/CT images and pointed that the relationship between parenchyma alterations and the organ's perfusion capability might not be so direct, given compensatory mechanisms.

12.
EJNMMI Res ; 14(1): 71, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39102057

RESUMEN

BACKGROUND: Relapsing Polychondritis(RP) is a rare rheumatic immune disease. As with most diseases, if intervention is delayed, the patient's prognosis is worse. Currently, the diagnostic criteria used in clinical practice do not include CT, PET/CT, SPECT/CT and other new imaging examinations that have developed rapidly in recent years. However, these examinations have some special manifestations for RP, which can help clinicians diagnose RP earlier and distinguish it from other diseases. CASE PRESENTATION: These five RP patients all had respiratory symptoms such as cough and wheezing as the first symptom, which could not be diagnosed in time according to the previous diagnostic criteria. The clinical data of the five patients are listed in Table 1. The relatively specific manifestations of SPECT/CT examination provided clinicians with very valuable clues to help them advance the diagnosis time. CONCLUSIONS: The application of SPECT/CT bone imaging in early diagnosing RP proves to be effective, enabling clinicians to intervene promptly and enhance the overall well-being and quality of life for individuals affected by this condition.

13.
J Nucl Med ; 65(9): 1395-1401, 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39117452

RESUMEN

177Lu can be imaged after administration using SPECT/CT. Most work to date has focused on using posttreatment imaging to measure normal organ and tumor dose. We aimed to assess the impact of posttreatment SPECT/CT on the management of patients undergoing 177Lu-prostate-specific membrane antigen (PSMA) radiopharmaceutical therapy (RPT). Methods: In this retrospective study, 122 patients underwent PSMA RPT with subsequent SPECT/CT 24 h after treatment. We determined a qualitative response at each cycle and reviewed patient charts to assess the impact that posttreatment SPECT/CT had on patient management. Changes in patient management were classified as changes on the basis of progression and response, and specific cycles when they occurred were noted. Miscellaneous changes in patient management were also evaluated. Results: Among the 122 consecutive patients examined, 42%-56% exhibited stable disease, whereas 19%-39% of patients exhibited response on visual assessment across treatment cycles. In total, 49% (n = 60) of patients experienced changes in management, of which 57% (n = 34) were due to progression, 40% (n = 24) were due to response, and 3% (n = 2) were due to miscellaneous changes. Changes due to disease progression were observed mostly after cycles 2 and 4. Changes due to response to RPT occurred mostly after cycles 3 and 4. Conclusion: At our center, 49% of patients experienced changes in management based on posttreatment SPECT/CT, and most of these changes occurred at cycles 2 and 4. Integrating posttreatment SPECT/CT into routine PSMA RPT protocols can aid in patient management.


Asunto(s)
Dipéptidos , Lutecio , Radiofármacos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Humanos , Masculino , Radiofármacos/uso terapéutico , Estudios Retrospectivos , Lutecio/uso terapéutico , Anciano , Dipéptidos/uso terapéutico , Persona de Mediana Edad , Resultado del Tratamiento , Compuestos Heterocíclicos con 1 Anillo/uso terapéutico , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/diagnóstico por imagen , Anciano de 80 o más Años , Antígeno Prostático Específico
14.
Quant Imaging Med Surg ; 14(8): 6087-6098, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39143990

RESUMEN

Background: Although small bowel bleeding is relatively rare, it is a potentially fatal disease, and its diagnosis still faces challenges. Technetium 99m-labeled red blood cell computed single photon emission computed tomography/computed tomography (99mTc-RBC SPECT/CT) and contrast-enhanced multidetector computed tomography (MDCT) are common imaging methods for diagnosing small bowel bleeding, but there have been no studies comparing their diagnostic efficacy for this purpose. This study aims to compare the diagnostic value of 99mTc-RBC SPECT/CT and contrast-enhanced MDCT for small bowel bleeding. Methods: A total of 44 patients (30 males and 14 females, median age of 64 years) definitively diagnosed with small bowel bleeding and 15 non-small bowel bleeding patients (8 males and 7 females, median age of 66 years) were consecutively included in this study. All patients underwent 99mTc-RBC SPECT/CT and contrast-enhanced MDCT examinations at Beijing Friendship Hospital of Capital Medical University between January 2020 to September 2023. The definitive diagnosis had been made through surgery or colonoscopy, or through patient history, patient management, and clinical follow-up. We collected clinical data of the participants. 99mTc-RBC SPECT/CT and contrast-enhanced MDCT were reviewed in a blinded fashion for accuracy of detection of active bleeding as well as the active small bowel bleeding location. Results: Among the 59 patients, the accuracy, sensitivity, and specificity of 99mTc-RBC SPECT were 27.3%, 93.3%, and 92.3%; for 99mTc-RBC SPECT/CT they were 76.3%, 40.5%, and 93.3%; whereas for contrast-enhanced MDCT they were 45.8%, 27.3%, and 100%, respectively. The diagnostic accuracy of 99mTc-RBC SPECT/CT for jejunal and ileal bleeding was high, at 100% and 86.4%, respectively. Meanwhile, 99mTc-RBC SPECT/CT had a higher accuracy in diagnosing more causes of small bowel bleeding. In 59 patients, the combination of 99mTc-RBC SPECT/CT and contrast-enhanced MDCT accurately diagnosed small bowel bleeding and provided precise localization in 50 patients, resulting in the accuracy, sensitivity, and specificity of 84.7%, 79.5%, and 100.0%, respectively. Conclusions: 99mTc-RBC SPECT/CT has high diagnostic value in diagnosing small bowel bleeding and is superior to 99mTc-RBC SPECT and contrast-enhanced MDCT. The combination of 99mTc-RBC SPECT/CT and contrast-enhanced MDCT can further improve the diagnostic accuracy of diagnosis, and can accurately guide the diagnosis and treatment of small bowel bleeding.

15.
Laryngoscope ; 2024 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-39210662

RESUMEN

OBJECTIVES: There is currently no reference standard test for the detection of the extra-esophageal manifestations of gastroesophageal reflux disease (GERD). The current suite of diagnostic tests principally assesses reflux events in the esophagus. A new scintigraphic technique has been developed and validated against reference standards. It allows direct visualization of refluxate in the laryngopharynx and lungs. METHODS: Fifty patients were assessed by scintigraphy before and after fundoplication at a single nuclear medicine facility. Standardized reflux symptom indices (RSIs) were obtained from each patient before and after surgery. Patients were scanned after oral 99 m technetium Fyton administration with early dynamic images and delayed SPECT/CT images of the head, neck, and lungs. ANOVA, Spearman correlation, and the Student's t-test were utilized for analysis. RESULTS: The study population (35F, 15 M) had a mean age of 63.9 years. Mean BMI was 26.8 with 67% being overweight or obese. All patients had significant reflux. SPECT/CT showed LPR events in 45/50 and pulmonary micro-aspiration (PMA) in 45/50 preoperatively and in 36/50 and 20/50 postoperatively, respectively. The RSI, cough, and throat clearing indices showed a significant fall postoperatively (p < 0.001). Frequency of scintigraphic reflux events was reduced from a mean of 4.5 in 30 min to 2.9 (t = 9.1, p = 0.004). CONCLUSION: The novel scintigraphic test detects esophageal and extra-esophageal reflux events and permits direct visualization of refluxate in the head and neck structures and lungs. It correlates well with symptoms of reflux in the esophagus and extra-esophageal structures and the response to therapy. LEVEL OF EVIDENCE: Although prospective, the study did not randomize patients and in effect each patient became their own control following an intervention (fundoplication). Thus, the study is Level 3 evidence Laryngoscope, 2024.

16.
Tomography ; 10(8): 1312-1319, 2024 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-39195733

RESUMEN

BACKGROUND: Distinguishing between Charcot Neuroarthropathy (CN), osteomyelitis (OM), and CN complicated with superimposed OM in diabetic patients is crucial for the treatment choice. Given that current diagnostic methods lack specificity, advanced techniques, e.g., magnetic resonance imaging (MRI) and 99mTc-HMPAO-WBC Single Photon Emission Computed Tomography (SPECT/CT), are needed. This study addresses the challenges in distinguishing OM and CN. METHODS: We included diabetic patients with CN and soft tissue ulceration. MRI and 99mTc-HMPAO-WBC SPECT/CT were used for the diagnosis. The patients were classified into three probability levels for OM (i.e., Definite, Probable, and Unlikely) according to the Consensus Criteria for Diabetic Foot Osteomyelitis (CC-DFO). RESULTS: Eight patients met the eligibility criteria. MRI, supported by SPECT-CT and CC-DFO, showed consistency with the OM diagnosis in three cases. The key diagnostic features included the location of signal abnormalities and secondary features such as skin ulcers, sinus tracts, and abscesses. Notably, cases with inconclusive MRI were clarified by SPECT/CT, emphasizing its efficacy in challenging scenarios. CONCLUSIONS: The primary objective of this study was to compare the results of MRI and 99mTc-HMPAO-WBC SPECT/CT with the CC-DFO score in the diabetic foot with CN and suspected OM. Advanced imaging offers a complementary approach to distinguish between CN and OM. This can help delineate the limits of the disease for presurgical planning. While MRI is valuable, 99mTc-HMPAO-WBC SPECT/CT provides additional clarity, especially in challenging cases or when metallic implants affect MRI accuracy.


Asunto(s)
Artropatía Neurógena , Pie Diabético , Imagen por Resonancia Magnética , Osteomielitis , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Humanos , Osteomielitis/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Femenino , Diagnóstico Diferencial , Artropatía Neurógena/diagnóstico por imagen , Anciano , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Pie Diabético/diagnóstico por imagen , Radiofármacos , Exametazima de Tecnecio Tc 99m
17.
Diagnostics (Basel) ; 14(16)2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-39202315

RESUMEN

Introducing a hybrid imaging approach, such as single-photon emission computerized tomography with X-ray computed tomography (SPECT)/CT, improves diagnostic accuracy and patient management. The ongoing advancement of SPECT hardware and software has resulted in the clinical application of novel approaches. For example, whole-body SPECT/CT (WB-SPECT/CT) studies cover multiple consecutive bed positions, similar to positron emission tomography-computed tomography (PET/CT). WB-SPECT/CT proves to be a helpful tool for evaluating bone metastases (BM), reducing equivocal findings, and enhancing user confidence, displaying effective performance in contrast to planar bone scintigraphy (PBS). Consequently, it is increasingly utilized and might substitute PBS, which leads to new questions and issues concerning the acquisition protocol, patient imaging time, and workflow process. Therefore, this review highlights various aspects of WB-SPECT/CT acquisition protocols that need to be considered to help understand WB-SPECT/CT workflow processes and optimize imaging protocols.

18.
EJNMMI Res ; 14(1): 75, 2024 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-39182210

RESUMEN

BACKGROUND: Serum bone turnover markers offer limited insight into metabolic activity at the individual vertebra level in osteoporosis. This study introduces a novel image-derived bone turnover marker for individual vertebrae to address this limitation, utilizing volumetric density-adjusted quantitative bone single-photon emission computed tomography/computed tomography (SPECT/CT) with [99mTc]Tc-DPD. This retrospective study included 177 lumbar vertebrae from 55 postmenopausal South Korean women. The mean standardized uptake value (SUVmean, g/cm3) and volumetric bone mineral density (vBMD, mg/cm3) were determined within a 2-cm³ volume of interest in the trabecular portion of each vertebra using quantitative SPECT and CT. The density-adjusted mean standardized uptake value (dSUVmean) was calculated by dividing the SUVmean by the vBMD and multiplying by 1,000. RESULTS: SUVmean correlated positively with vBMD (r = 0.60, p < 0.001). Conversely, dSUVmean correlated negatively with vBMD (ρ = -0.66, p < 0.001), highlighting the inverse relationship between bone mass and turnover after density adjustment of SUVmean. Patients with major osteoporotic fractures had lower vBMD (62.5 ± 29.4 vs. 92.3 ± 27.4 mg/cm³, p = 0.001) but higher dSUVmean (100.8 ± 60.7 vs. 62.6 ± 17.5, p = 0.001) compared to those without fractures, reinforcing the association between fracture prevalence, low bone mass, and high bone turnover. CONCLUSION: Volumetric density-adjusted quantitative bone SPECT/CT offers a novel image-derived bone turnover marker for assessing bone turnover in osteoporosis. This method provides a precise assessment of fragility at the individual vertebra level, which may enhance personalized osteoporosis management.

19.
Radiol Cardiothorac Imaging ; 6(4): e230377, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39115407

RESUMEN

Ventilation-perfusion SPECT with or without CT using technetium 99m (99mTc)-diethylenetriaminepentaacetic acid (DTPA) has been used to identify patterns typical of cardiopulmonary diseases, such as pulmonary embolism, pneumonia, heart failure, and obstructive lung disease. This case demonstrates the utility of a ventilation scan with SPECT/CT using 99mTc-DTPA for investigating the cause of a persistent complex pneumothorax in a patient with severe chronic obstructive pulmonary disease who recently underwent endobronchial valve placement. Keywords: CT-Spectral Imaging (Multienergy), SPECT/CT, Thorax, Lung Supplemental material is available for this article. © RSNA, 2024.


Asunto(s)
Neumotórax , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Pentetato de Tecnecio Tc 99m , Humanos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Neumotórax/diagnóstico por imagen , Neumotórax/etiología , Masculino , Radiofármacos , Enfermedad Pulmonar Obstructiva Crónica/complicaciones , Anciano
20.
J Pak Med Assoc ; 74(8): 1555-1556, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39160737

RESUMEN

Hepatocellular carcinoma (HCC), sixth most common cancer world-over, commonly metastasizes to lung, lymph nodes and adrenal glands. Incidence of osseous metastases in HCC has been reported to be 3-20 % which occurs predominantly in the axial skeleton. It only rarely occurs in the appendicular skeleton and that too as the solitary focus of metastatic deposit.3,4 We present a case of HCC with solitary osseous metastases to the proximal tibia.


Asunto(s)
Neoplasias Óseas , Carcinoma Hepatocelular , Neoplasias Hepáticas , Tibia , Humanos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/patología , Carcinoma Hepatocelular/secundario , Neoplasias Hepáticas/secundario , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Neoplasias Óseas/secundario , Neoplasias Óseas/diagnóstico por imagen , Neoplasias Óseas/patología , Masculino , Tibia/diagnóstico por imagen , Tibia/patología , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...