Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
1.
Ann Biomed Eng ; 2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39249170

RESUMEN

The need for safe and effective methods to manage deep vein thrombosis (DVT), given the risks associated with anticoagulants and thrombolytic agents, motivated research into innovative approaches to resolve blood clots. In response to this challenge, sonothrombolysis is being explored as a technique that combines microbubbles, ultrasound, and thrombolytic agents to facilitate the aggressive dissolution of thrombi. Prior studies have indicated that relatively large microbubbles accelerate the dissolution process, either in an in vitro or an arterial model. However, sonothrombolysis using large microbubbles must be evaluated in venous thromboembolism diseases, where blood flow velocity is not comparable. In this study, the efficacy of sonothrombolysis was validated in a murine model of pre-existing DVT. During therapy, microfluidically produced microbubbles of 18 µm diameter and recombinant tissue plasminogen activator (rt-PA) were administered through a tail vein catheter for 30 min, while ultrasound was applied to the abdominal region of the mice. Three-dimensional ultrasound scans were performed before and after therapy for quantification. The residual volume of the thrombi was 20% in animals post sonothrombolysis versus 52% without therapy ( p = 0.012 < 0.05 ), indicating a significant reduction in DVT volume. Histological analysis of tissue sections confirmed a reduction in DVT volume post-therapy. Therefore, large microbubbles generated from a microfluidic device show promise in ultrasound-assisted therapy to address concerns related to venous thromboembolism.

2.
Cardiovasc Ultrasound ; 22(1): 10, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-39118073

RESUMEN

From its inception as a two-dimensional snapshot of the beating heart, echocardiography has become an indelible part of cardiovascular diagnostics. The integration of ultrasound enhancing agents (UEAs) marks a pivotal transition, enhancing its diagnostic acumen beyond myocardial perfusion. These agents have refined echocardiography's capacity to visualize complex cardiac anatomy and pathology with unprecedented clarity, especially in non-coronary artery disease contexts. UEAs aid in detailed assessments of myocardial viability, endocardial border delineation in left ventricular opacification, and identification of intracardiac masses. Recent innovations in UEAs, accompanied by advancements in echocardiographic technology, offer clinicians a more nuanced view of cardiac function and blood flow dynamics. This review explores recent developments in these applications and future contemplated studies.


Asunto(s)
Medios de Contraste , Ecocardiografía , Humanos , Ecocardiografía/métodos , Enfermedades Cardiovasculares/diagnóstico por imagen , Enfermedades Cardiovasculares/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Aumento de la Imagen/métodos , Microburbujas
3.
J R Coll Physicians Edinb ; : 14782715241273737, 2024 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-39136288

RESUMEN

BACKGROUND: Despite advances in timely revascularisation of ST elevation myocardial infarction (STEMI) patients, there are several practical and unavoidable delays. Sonothrombolysis (administered during micro boluses of Perfluoropropane) initiated bedside as a point-of-care therapy during the initial evaluation of the patient may potentially mitigate this by producing early culprit vessel revascularisation. METHODS: This was a prospective, single-centre study on hemodynamically stable patients presenting within 12 hours of a first STEMI who consented for study participation. RESULTS: Fifteen patients were recruited over a 1-month period. Eleven were male. Nine patients had anterior wall STEMI and left anterior descending as culprit vessel. There were no significant changes in safety outcomes. Median First Medical Contact (FMC)-Sono time was 12 min (10-15). Median duration of sonothrombolysis was 14 min (12-16). FMC-device time was 97 min (79-128). Six patients had culprit vessel recanalisation before primary percutaneous coronary intervention (PPCI) which was consistent with the reference rates of therapy-associated recanalisation (p = 0.535). CONCLUSION: Micro bolus sonothrombolysis maybe safely initiated as a point of care therapy adjunctive to PPCI in hemodynamically stable STEMI patients with reasonable efficacy. Further randomised trials are needed to ascertain its applicability in various geographical and clinical settings.

4.
Artículo en Inglés | MEDLINE | ID: mdl-38972613

RESUMEN

BACKGROUND AND AIMS: Approximately 50% of patients with ST elevation myocardial infarction (STEMI) treated with percutaneous coronary intervention (PCI) experience microvascular no-reflow. Pre- and post-PCI sonothrombolysis has been shown to decrease infarct size and improve left ventricular (LV) systolic function in STEMI patients receiving urgent PCI. The aim of this study was to investigate whether post-PCI sonothrombolysis alone in STEMI patients with persistent ST elevation could reduce no-reflow and infarct size. METHODS: Patients with STEMI with symptoms <12 hours who had persistent ST elevation (≤70% ST resolution) after primary PCI were randomized to sonothrombolysis or control. The primary end point was summed (Σ) ST elevation 60 minutes after study intervention. Secondary end points included infarct size, myocardial perfusion score, LV ejection fraction on cardiovascular magnetic resonance imaging at 2 months follow-up, and clinical outcome at 6-month follow-up. RESULTS: Sixty-seven STEMI patients with persistent ST elevation after PCI were randomized (49 left anterior descending, 18 right coronary/left circumflex artery). No difference was observed in Σ ST elevation 60 minutes after study intervention (mean difference, 0.6 mm; 95% CI, -1.1 to 2.2, P = .50). Complete ST resolution occurred in 14 (40%) of patients treated with sonothrombolysis compared to 6 (19%) of controls (P = .16). Myocardial perfusion score index (1.5 ± 0.3 vs 1.5 ± 0.3, P = .93), infarct size (18.0% ± 10% vs 16.8% ± 11%; P = .29) and LV ejection fraction on cardiovascular magnetic resonance (46% ± 8% vs 47% ± 11% in the control group; P = .86) were comparable. Incidence of all-cause death, acute coronary syndrome, and hospital admission for heart failure at 6-month follow-up was similar between the groups (sonothrombolysis, 2; control, 5). CONCLUSIONS: In STEMI patients with persistent ST elevation after PCI, post-PCI sonothrombolysis did not result in more ST resolution or smaller infarct size compared to control subjects. The incidence of the combined clinical end points was remarkably low in this high-risk patient population.

5.
Artículo en Inglés | MEDLINE | ID: mdl-38986920

RESUMEN

BACKGROUND: Sonothrombolysis is a therapeutic application of ultrasound with ultrasound contrast for patients with ST elevation myocardial infarction (STEMI). Recent trials demonstrated that sonothrombolysis, delivered before and after primary percutaneous coronary intervention (pPCI), increases infarct vessel patency, improves microvascular flow, reduces infarct size, and improves ejection fraction. However, it is unclear whether pre-pPCI sonothrombolysis is essential for therapeutic benefit. We designed a parallel 3-arm sham-controlled randomized controlled trial to address this. METHODS: Patients presenting with first STEMI undergoing pPCI within 6 hours of symptom onset were randomized 1:1:1 into 3 arms: sonothrombolysis pre-/post-pPCI (group 1), sham pre- sonothrombolysis post-pPCI (group 2), and sham pre-/post-pPCI (group 3). Our primary end point was infarct size (percentage of left ventricular mass) assessed by cardiac magnetic resonance imaging at day 4 ± 2. Secondary end points included myocardial salvage index (MSI) and echocardiographic parameters at day 4 ± 2 and 6 months. RESULTS: Our trial was ceased early due to the COVID pandemic. From 122 patients screened between September 2020 and June 2021, 51 patients (age 60, male 82%) were included postrandomization. Median sonothrombolysis took 5 minutes pre-pPCI and 15 minutes post-, without significant door-to-balloon delay. There was a trend toward reduction in median infarct size between group 1 (8% [interquartile range, 4,11]), group 2 (11% [7, 19]), or group 3 (15% [9, 22]). Similarly there was a trend toward improved MSI in group 1 (79% [64, 85]) compared to groups 2 (51% [45, 70]) and 3 (48% [37, 73]) No major adverse cardiac events occurred during hospitalization. CONCLUSIONS: Pre-pPCI sonothrombolysis may be key to improving MSI in STEMI. Multicenter trials and health economic analyses are required before clinical translation.

6.
J Thromb Thrombolysis ; 57(6): 1056-1066, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38824486

RESUMEN

Microbubble-mediated sonothrombolysis has been proven to be a non-invasive and efficient method for thrombolysis. Nevertheless, there is a potential risk that the thrombus debris generated during the dissolution of the original thrombus are too large and can lead to hazardous emboli. Using a sonothrombolysis microfluidic platform, we investigated the effects of ultrasound power, thrombolytic agent and microbubble concentration on the size of thrombus debris with the example of microbubble-mediated sonothrombolysis of arterial thrombus. Additionally, we studied the effects of ultrasound power on the size and shape of thrombus debris produced by acute and chronic arterial sonothrombolysis. In acute arterial sonothrombolysis, ultrasound power has significant effect on the size of thrombus debris and steadily increases with the increase of ultrasound power. Conversely, in chronic arterial sonothrombolysis, the size of thrombus debris is minimally affected by ultrasound power. Using the sonothrombolysis microfluidic platform, the relationship between ultrasound power and the safety of sonothrombolysis has been illustrated, and the sonothrombolysis microfluidic platform is demonstrated to be a promising tool for further studies on the process of sonothrombolysis.


Asunto(s)
Microburbujas , Trombosis , Terapia por Ultrasonido , Trombosis/diagnóstico por imagen , Trombosis/etiología , Trombosis/terapia , Terapia por Ultrasonido/métodos , Terapia por Ultrasonido/efectos adversos , Humanos , Dispositivos Laboratorio en un Chip , Terapia Trombolítica/métodos , Fibrinolíticos/uso terapéutico
7.
J Nanobiotechnology ; 22(1): 311, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38831332

RESUMEN

Efficient thrombolysis in time is crucial for prognostic improvement of patients with acute arterial thromboembolic disease, while limitations and complications still exist in conventional thrombolytic treatment methods. Herein, our study sought to investigate a novel dual-mode strategy that integrated ultrasound (US) and near-infrared light (NIR) with establishment of hollow mesoporous silica nanoprobe (HMSN) which contains Arginine-glycine-aspartate (RGD) peptide (thrombus targeting), perfluoropentane (PFP) (thrombolysis with phase-change and stable cavitation) and indocyanine green (ICG) (thrombolysis with photothermal conversion). HMSN is used as the carrier, the surface is coupled with targeted RGD to achieve high targeting and permeability of thrombus, PFP and ICG are loaded to achieve the collaborative diagnosis and treatment of thrombus by US and NIR, so as to provide a new strategy for the integration of diagnosis and treatment of arterial thrombus. From the in vitro and in vivo evaluation, RGD/ICG/PFP@HMSN can aggregate and penetrate at the site of thrombus, and finally establish the dual-mode directional development and thrombolytic treatment under the synergistic effect of US and NIR, providing strong technical support for the accurate diagnosis and treatment of arterial thrombosis.


Asunto(s)
Verde de Indocianina , Rayos Infrarrojos , Oligopéptidos , Terapia Trombolítica , Trombosis , Animales , Terapia Trombolítica/métodos , Oligopéptidos/química , Verde de Indocianina/química , Trombosis/diagnóstico por imagen , Trombosis/tratamiento farmacológico , Nanopartículas/química , Fluorocarburos/química , Dióxido de Silicio/química , Humanos , Ratones , Masculino , Conejos , Ultrasonografía/métodos , Pentanos
8.
Echocardiography ; 41(6): e15860, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38889076

RESUMEN

PURPOSE: Persistent microvascular obstruction (MVO) after successful percutaneous coronary intervention (PCI) in acute ST segment elevation myocardial infarction (STEMI) has been well-described. MVO predicts lack of recovery of left ventricular function and increased mortality. Sonothrombolysis utilizing diagnostic ultrasound induced cavitation of commercially available microbubble contrast has been effective at reducing infarct size and improving left ventricular ejection fraction (LVEF) when performed both pre- and post-PCI. However, the effectiveness of post-PCI sonothrombolysis alone after successful PCI has not been demonstrated. METHODS: A prospective randomized controlled trial was performed in 50 consecutive consenting patients with anterior STEMI who underwent a continuous microbubble infusion immediately following successful PCI. Intermittent high mechanical index (MI) impulses were applied only in the sonthrombolysis group. Delayed enhancement magnetic resonance imaging (MRI) was performed at 48 h and again at 6-8 weeks to assess for differences in infarct size, LVEF, and MVO. RESULTS: There were no differences between groups in age, gender, and cardiovascular risk factors. Significant (> 2 segments) MVO following successful PCI was observed in 66% of patients. Although sonothrombolysis reduced the extent of MVO acutely, there were no differences in infarct size, LVEF, or extent of MVO by MRI at 48 h. Twenty-eight patients returned for a follow up MRI at 6-8 weeks. LVEF improved only in the sonothrombolysis group (∆LVEF 7.81 ± 4.57% with sonothrombolysis vs. 1.77 ± 7.02% for low MI only, p = .011). CONCLUSION: Post-PCI sonothrombolysis had minimal effect on reducing myocardial infarct size but improved left ventricular systolic function in patients with acute anterior wall STEMI.


Asunto(s)
Intervención Coronaria Percutánea , Humanos , Femenino , Masculino , Intervención Coronaria Percutánea/métodos , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento , Infarto del Miocardio con Elevación del ST/fisiopatología , Infarto del Miocardio con Elevación del ST/cirugía , Recuperación de la Función , Infarto del Miocardio/fisiopatología , Microburbujas , Ecocardiografía/métodos , Microcirculación/fisiología , Medios de Contraste , Anciano
9.
J Cardiovasc Dev Dis ; 11(3)2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38535098

RESUMEN

Stroke is a major cause of death and disability globally, with ischemic stroke being the predominant mechanism. While spontaneous recanalization may occur, significant neuronal injury would have occurred in the interim. Intravenous thrombolysis administered within the first 4.5 h after stroke onset and endovascular thrombectomy within 24 h in patients with a salvageable penumbra improves functional independence. Ultrasound has been shown in both in vivo and in vitro models to enhance clot lysis, even more-so in the presence of thrombolytic agents. The use of transcranial Doppler and transcranial color-coded Doppler ultrasound in acute IS has been reported in case series, case-controlled studies, and clinical trials. While ultrasound at a frequency of 300 kHz increases the risk of intracranial hemorrhage, the 2 MHz range ultrasound aids thrombolysis and improves recanalization without significantly increasing the risk of symptomatic intracranial hemorrhage. Despite this, functional independence was not increased in clinical trials, nor was a benefit shown with the adjunctive use of microbubbles or microspheres. Nonetheless, newer technologies such as endovascular ultrasound, endovascular delivery of microbubbles, and thrombolytic-filled microbubbles await clinical trials. More evidence is needed before sonothrombolysis can be routinely used in the hyperacute management of ischemic stroke.

10.
Ultrasonics ; 138: 107223, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38553135

RESUMEN

Thrombotic occlusions of large blood vessels are increasingly treated with catheter based mechanical approaches, one of the most prominent being to employ aspiration to extract clots through a hollow catheter lumen. A central technical challenge for aspiration catheters is to achieve sufficient suction force to overcome the resistance of clot material entering into the distal tip. In this study, we examine the feasibility of inducing cavitation within hollow cylindrical transducers with a view to ultimately using them to degrade the mechanical integrity of thrombus within the tip of an aspiration catheter. Hollow cylindrical radially polarized PZT transducers with 3.3/2.5 mm outer/inner diameters were assessed. Finite element simulations and hydrophone experiments were used to investigate the pressure field distribution as a function of element length and resonant mode (thickness, length). Operating in thickness mode (∼5 MHz) was found to be associated with the highest internal pressures, estimated to exceed 23 MPa. Cavitation was demonstrated to be achievable within the transducer under degassed water (10 %) conditions using hydrophone detection and high-frequency ultrasound imaging (40 MHz). Cavitation clouds occupied a substantial portion of the transducer lumen, in a manner that was dependent on the pulsing scheme employed (10 and 100 µs pulse lengths; 1.1, 11, and 110 ms pulse intervals). Collectively the results support the feasibility of achieving cavitation within a transducer compatible with mounting in the tip of an aspiration format catheter.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Transductores , Succión , Catéteres , Agua
11.
J Thromb Thrombolysis ; 57(5): 788-796, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38393673

RESUMEN

The treatment of acute ischemic stroke has improved in last few decades. While meta-analyses of several trials have established the safety and efficacy of Intravenous (IV) Tenecteplase thrombolysis, concomitant continuous transcranial doppler (TCD) ultrasound administration has not been assessed in any clinical trial. The aim of this study was to determine the effects of continuous 2 MHz TCD ultrasound during IV Tenecteplase thrombolysis for Middle cerebral artery (MCA) stroke. A total of 19 patients were included, 13 received TCD ultrasound and 6 sham TCD with IV Tenecteplase. TCD spectrum and difference in Pre and post TCD parameters were measured. Asymptomatic hemorrhagic transformation of infarct was seen in two patients. There was no mortality or clinical worsening in the sonothrombolysis group as against sham sonothrombolysis group. Median of peak systolic velocity was increased in both the sonothrombolysis (P = 0.0002) and sham sonothrombolysis group (P-value = 0.001). The difference in change in mean flow velocity between two groups, sonothrombolysis (11 cm/sec) and sham sonothrombolysis (3.5 cm/sec) were also significantly different (P = 0.014). This pilot work has established safety of continuous 30 min TCD application along with IV Tenecteplase thrombolysis and it concludes that concomitant 2 MHz TCD ultrasound administration significantly increased the MCA blood flow compared to chemothrombolysis alone.CTRI Registered Number: CTRI/2021/02/031418.


Asunto(s)
Fibrinolíticos , Accidente Cerebrovascular Isquémico , Tenecteplasa , Terapia Trombolítica , Activador de Tejido Plasminógeno , Ultrasonografía Doppler Transcraneal , Humanos , Tenecteplasa/administración & dosificación , Tenecteplasa/uso terapéutico , Ultrasonografía Doppler Transcraneal/métodos , Masculino , Persona de Mediana Edad , Femenino , Accidente Cerebrovascular Isquémico/tratamiento farmacológico , Accidente Cerebrovascular Isquémico/terapia , Accidente Cerebrovascular Isquémico/diagnóstico por imagen , Terapia Trombolítica/métodos , Fibrinolíticos/uso terapéutico , Fibrinolíticos/administración & dosificación , Anciano , Activador de Tejido Plasminógeno/administración & dosificación , Activador de Tejido Plasminógeno/uso terapéutico , Infarto de la Arteria Cerebral Media/terapia , Infarto de la Arteria Cerebral Media/tratamiento farmacológico , Infarto de la Arteria Cerebral Media/diagnóstico por imagen , Resultado del Tratamiento , Terapia Combinada
12.
IEEE Open J Nanotechnol ; 4: 109-132, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38111792

RESUMEN

Nanoparticles containing thrombolytic medicines have been developed for thrombolysis applications in response to the increasing demand for effective, targeted treatment of thrombosis disease. In recent years, there has been a great deal of interest in nanoparticles that can be navigated and driven by a magnetic field. However, there are few review publications concerning the application of magnetic nanoparticles in thrombolysis. In this study, we examine the current state of magnetic nanoparticles in the application of in vitro and in vivo thrombolysis under a static or dynamic magnetic field, as well as the combination of magnetic nanoparticles with an acoustic field for dual-mode thrombolysis. We also discuss four primary processes of magnetic nanoparticles mediated thrombolysis, including magnetic nanoparticle targeting, magnetic nanoparticle trapping, magnetic drug release, and magnetic rupture of blood clot fibrin networks. This review will offer unique insights for the future study and clinical development of magnetic nanoparticles mediated thrombolysis approaches.

13.
Ultrasound Med Biol ; 49(11): 2388-2397, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37648590

RESUMEN

OBJECTIVE: Cavitation-enhanced delivery of therapeutic agents is under development for the treatment of cancer and neurodegenerative and cardiovascular diseases, including sonothrombolysis for deep vein thrombosis. The objective of this study was to quantify the spatial and temporal distribution of cavitation activity nucleated by Definity infused through the EKOS catheter over a range of acoustic parameters controlled by the EKOS endovascular system. METHODS: Three insonation protocols were compared in an in vitro phantom mimicking venous flow to measure the effect of peak rarefactional pressure, pulse duration and pulse repetition frequency on cavitation activity energy, location and duration. Inertial and stable cavitation activity was quantified using passive cavitation imaging, and a metric of cavitation dose based on energy density was defined. RESULTS: For all three insonation protocols, cavitation was sustained for the entire 30 min Definity infusion. The evolution of cavitation energy during each pulse duration was similar for all three protocols. For insonation protocols with higher peak rarefactional acoustic pressures, inertial and stable cavitation doses also increased. A complex relationship between the temporal behavior of cavitation energy within each pulse and the pulse repetition frequency affected the cavitation dose for the three insonation protocols. The relative predominance of stable or inertial cavitation dose varied according to insonation schemes. Passive cavitation images revealed the spatial distribution of cavitation activity. CONCLUSION: Our cavitation dose metric based on energy density enabled the impact of different acoustic parameters on cavitation activity to be measured. Depending on the type of cavitation to be promoted or suppressed, particular pulsing schemes could be employed in future studies, for example, to correlate cavitation dose with sonothrombolytic efficacy.


Asunto(s)
Acústica , Fluorocarburos , Catéteres , Frecuencia Cardíaca
14.
Ultrason Sonochem ; 96: 106435, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37178667

RESUMEN

Whilst sonothrombolysis is a promising and noninvasive ultrasound technique for treating blood clots, bleeding caused by thrombolytic agents used for dissolving clots and potential obstruction of blood flow by detached clots (i.e., embolus) are the major limitations of the current approach. In the present study, a new sonothrombolysis method is proposed for treating embolus without the use of thrombolytic drugs. Our proposed method involves (a) generating a spatially localised acoustic radiation force in a blood vessel against the blood flow to trap moving blood clots (i.e., generation of an acoustic net), (b) producing acoustic cavitation to mechanically destroy the trapped embolus, and (c) acoustically monitoring the trapping and mechanical fractionation processes. Three different ultrasound transducers with different purposes were employed in the proposed method: (1) 1-MHz dual focused ultrasound (dFUS) transducers for capturing moving blood clots, (2) a 2-MHz High Intensity Focused Ultrasound (HIFU) source for fractionating blood clots and (3) a passive acoustic emission detector with broad bandwidth (10 kHz to 20 MHz) for receiving and analysing acoustic waves scattered from a trapped embolus and acoustic cavitation. To demonstrate the feasibility of the proposed method, in vitro experiments with an optically transparent blood vessel-mimicking phantom filled with a blood mimicking fluid and a blood clot (1.2 to 5 mm in diameter) were performed with varying the dFUS and HIFU exposure conditions under various flow conditions (from 1.77 to 6.19 cm/s). A high-speed camera was used to observe the production of acoustic fields, acoustic cavitation formation and blood clot fragmentation within a blood vessel by the proposed method. Numerical simulations of acoustic and temperature fields generated under a given exposure condition were also conducted to further interpret experimental results on the proposed sonothrombolysis. Our results clearly showed that fringe pattern-like acoustic pressure fields (fringe width of 1 mm) produced in a blood vessel by the dFUS captured an embolus (1.2 to 5 mm in diameter) at the flow velocity up to 6.19 cm/s. This was likely to be due to the greater magnitude of the dFUS-induced acoustic radiation force exerted on an embolus in the opposite direction to the flow in a blood vessel than that of the drag force produced by the flow. The acoustically trapped embolus was then mechanically destructed into small pieces of debris (18 to 60 µm sized residual fragments) by the HIFU-induced strong cavitation without damaging the blood vessel walls. We also observed that acoustic emissions emitted from a blood clot captured by the dFUS and cavitation produced by the HIFU were clearly distinguished in the frequency domain. Taken together, these results can suggest that our proposed sonothrombolysis method could be used as a promising tool for treating thrombosis and embolism through capturing and destroying blood clots effectively.


Asunto(s)
Embolia , Ultrasonido Enfocado de Alta Intensidad de Ablación , Trombosis , Humanos , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Trombosis/terapia , Embolia/terapia , Fantasmas de Imagen , Acústica
15.
Ultrasound Med Biol ; 49(5): 1049-1057, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36868959

RESUMEN

Thrombosis in cardiovascular disease is an urgent global issue, but treatment progress is limited by the risks of current antithrombotic approaches. The cavitation effect in ultrasound-mediated thrombolysis offers a promising mechanical alternative for clot lysis. Further addition of microbubble contrast agents introduces artificial cavitation nuclei that can enhance the mechanical disruption induced by ultrasound. Recent studies have proposed sub-micron particles as novel sonothrombolysis agents with increased spatial specificity, safety and stability for thrombus disruption. In this article, the applications of different sub-micron particles for sonothrombolysis are discussed. Also reviewed are in vitro and in vivo studies that apply these particles as cavitation agents and as adjuvants to thrombolytic drugs. Finally, perspectives on future developments in sub-micron agents for cavitation-enhanced sonothrombolysis are shared.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación , Trombolisis Mecánica , Trombosis , Terapia por Ultrasonido , Humanos , Ultrasonografía , Trombosis/tratamiento farmacológico , Fibrinolíticos/uso terapéutico , Microburbujas , Terapia Trombolítica
16.
Biomaterials ; 294: 122025, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36716588

RESUMEN

Microbubbles (MBs) were observed for the first time in vivo as a curious consequence of quick saline injection during ultrasound (US) imaging of the aortic root, more than 50 years ago. From this serendipitous event, MBs are now widely used as contrast enhancers for US imaging. Their intrinsic properties described in this review, allow a multitude of designs, from shell to gas composition but also from grafting targeting agents to drug payload encapsulation. Indeed, the versatile MBs are deeply studied for their dual potential in imaging and therapy. As presented in this paper, new generations of MBs now opens perspectives for targeted molecular imaging along with the development of new US imaging systems. This review also presents an overview of the different therapeutic strategies with US and MBs for cancer, cardiovascular diseases, and inflammation. The overall aim is to overlap those fields in order to find similarities in the MBs application for treatment enhancement associated with US. To conclude, this review explores the new scales of MBs technologies with nanobubbles development, and along concurrent advances in the US imaging field. This review ends by discussing perspectives for the booming future uses of MBs.


Asunto(s)
Sistemas de Liberación de Medicamentos , Microburbujas , Humanos , Sistemas de Liberación de Medicamentos/métodos , Medios de Contraste/uso terapéutico , Ultrasonido , Ultrasonografía/métodos
17.
J Am Soc Echocardiogr ; 36(5): 504-513, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36535625

RESUMEN

BACKGROUND: The diagnostic ultrasound-guided high mechanical index impulses during an intravenous microbubble infusion (sonothrombolysis) improve myocardial perfusion in acute ST segment elevation myocardial infarction, but its effect on left ventricular diastolic dysfunction (DD), left atrial (LA) mechanics and remodeling is unknown. We assessed the effect of sonothrombolysis on DD grade and LA mechanics. METHODS: One hundred patients (59 ± 10 years; 34% women) were randomized to receive either high mechanical index impulses plus percutaneous coronary intervention (PCI) (therapy group) or PCI only (control group) (n = 50 in each group). Diastolic dysfunction grade and LA mechanics were assessed immediately before and after PCI and at 48 to 72 hours, 1 month, and 6 months of follow-up. Diastolic dysfunction grades were classified as grades I, II, and III. The LA mechanics was obtained by two-dimensional speckle-tracking echocardiography-derived global longitudinal strain (GLS). RESULTS: As follow-up time progressed, increased DD grade was observed more frequently in the control group than in the therapy group at 1 month and 6 months of follow-up (all P < .05). The LA-GLS values were incrementally higher in the therapy group when compared with the control group at 48 to 72 hours, 24.0% ± 7.3% in the therapy group versus 19.6% ± 7.2% in the control group, P = .005; at 1 month, 25.3% ± 6.3% in the therapy group versus 21.5% ± 8.3% in the control group, P = .020; and at 6 months, 26.2% ± 8.7% in the therapy group versus 21.6% ± 8.5% in the control group, P = .015. The therapy group was less likely to experience LA remodeling (odds ratio, 2.91 [1.10-7.73]; P = .03). LA-GLS was the sole predictor of LA remodeling (odds ratio, 0.79 [0.67-0.94]; P = .006). CONCLUSION: Sonothrombolysis is associated with better DD grade and LA mechanics, reducing LA remodeling.


Asunto(s)
Fibrilación Atrial , Remodelación Atrial , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , Femenino , Masculino , Infarto del Miocardio con Elevación del ST/diagnóstico , Infarto del Miocardio con Elevación del ST/terapia , Intervención Coronaria Percutánea/métodos , Atrios Cardíacos/diagnóstico por imagen , Función Ventricular Izquierda , Remodelación Ventricular
18.
Children (Basel) ; 11(1)2023 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-38255371

RESUMEN

In recent years, advances in ultrasound therapeutics have been implemented into treatment algorithms for the adult population; however, the use of therapeutic ultrasound in the pediatric population still needs to be further elucidated. In order to better characterize the utilization and practicality of sonothrombolysis in the juvenile population, the authors conducted a literature review of current pediatric research in therapeutic ultrasound. The PubMed database was used to search for all clinical and preclinical studies detailing the use and applications of sonothrombolysis, with a focus on the pediatric population. As illustrated by various review articles, case studies, and original research, sonothrombolysis demonstrates efficacy and safety in clot dissolution in vitro and in animal studies, particularly when combined with microbubbles, with potential applications in conditions such as deep venous thrombosis, peripheral vascular disease, ischemic stroke, myocardial infarction, and pulmonary embolism. Although there is limited literature on the use of therapeutic ultrasound in children, mainly due to the lower prevalence of thrombotic events, sonothrombolysis shows potential as a noninvasive thrombolytic treatment. However, more pediatric sonothrombolysis research needs to be conducted to quantify the safety and ethical considerations specific to this vulnerable population.

19.
J Control Release ; 350: 870-885, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36096365

RESUMEN

Sonothrombolysis with recombinant tissue plasminogen activator (rtPA) and microbubbles has been widely studied to enhance thrombolytic potential. Here, we report different sonothrombolysis strategy in nanoparticles using microbubbles cavitation. We found that different particles in shape exhibited different reactivity toward the cavitation, leading to a distinct sonothrombolytic potential. Two different gold nanoparticles in shape were functionalized with the rtPA: rtPA-functionalized gold nanospheres (NPt) and gold nanostars (NSt). NPt could not accelerate the thrombolytic potential with a sole acoustic stimulus. Importantly, NSt enhanced the potential with acoustic stimulus and microbubble-mediated cavitation, while NPt were not reactive to cavitation. Coadministration of NSt and microbubbles resulted in a dramatic reduction of the infarcts in a photothrombotic model and recovery in the cerebral blood flow. Given the synergistic effect and in vivo feasibility of this strategy, cavitation-assisted sonothrombolysis by asymmetrical NSt might be useful for treating acute ischemic stroke.


Asunto(s)
Accidente Cerebrovascular Isquémico , Nanopartículas del Metal , Fibrinolíticos/uso terapéutico , Oro , Humanos , Terapia Trombolítica/métodos , Activador de Tejido Plasminógeno/uso terapéutico
20.
J Endovasc Ther ; : 15266028221126938, 2022 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-36172738

RESUMEN

PURPOSE: Intra-arterial administration of microbubbles (MBs) through an ultrasound (US) catheter increases the local concentration of MBs into the thrombus and may further enhance outcomes of contrast-enhanced sonothrombolysis (CEST). The objective of this study was to evaluate the feasibility and lytic efficacy of intra-arterial infusion of MBs during US-enhanced thrombolysis in both in vitro and in vivo peripheral arterial occluded models. MATERIALS AND METHODS: SonoVue and Luminity MBs were infused at a flow rate of 20 mL/h through either the drug delivery lumen of the US catheter (DDC, n=20) or through the tube lumen of the vascular phantom (systematic infusion, n=20) during thrombolysis with a low-dose urokinase (UK) protocol (50 000 IU/h) with(out) US application to assess MB survivability and size by pre-treatment and post-treatment measurements. A human thrombus was placed into a vascular phantom of the flow system to examine the lytic effects of CEST by post-treatment D-dimer concentrations measurements of 5 treatment conditions (saline, UK, UK+US, UK+US+SonoVue, and UK+US+Luminity). Thrombolytic efficacy of localized MBs and US delivery was then investigated in vivo in 5 porcine models by arterial blood flow, microcirculation, and postmortem determined thrombus weight and remaining length. RESULTS: US exposure significantly decreased SonoVue (p=0.000) and Luminity (p=0.000) survivability by 37% and 62%, respectively. In vitro CEST treatment resulted in higher median D-dimer concentrations for the SonoVue (0.94 [0.07-7.59] mg/mL, p=0.025) and Luminity (0.83 [0.09-2.53] mg/mL, p=0.048) subgroups when compared with thrombolysis alone (0.36 [0.02-1.00] mg/mL). The lytic efficacy of CEST examined in the porcine model showed an improved median arterial blood flow of 21% (7%-79%), and a median thrombus weight and length of 1.02 (0.96-1.43) g and 2.25 (1.5-4.0) cm, respectively. One allergic reaction and 2 arrhythmias were observed due to the known allergic reaction on lipids in the porcine model. CONCLUSION: SonoVue and Luminity can be combined with an US catheter and could potentially accelerate thrombolytic treatment of peripheral arterial occlusions. CLINICAL IMPACT: Catheter-directed thrombolysis showed to be an effective alternative to surgery for acute peripheral arterial occlusions, but this technique is still associated with several limb and life-threatening complications. The effects of thrombolysis on clot dissolution may be further enhanced by intra-arterial administration of microbubbles through an ultrasound catheter. This study demonstrates the feasibility and lytic efficacy of intra-arterial infusion of microbubbles during US-enhanced thrombolysis in both in vitro and in vivo peripheral arterial occluded models.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...