Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 112
Filtrar
1.
Materials (Basel) ; 17(17)2024 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-39274728

RESUMEN

This work presents a 2D radiochromic dosimeter for ultraviolet (UV) radiation measurements, based on cotton fabric volume-modified with nitroblue tetrazolium chloride (NBT) as a radiation-sensitive compound. The developed dosimeter is flexible, which allows it to adapt to various shapes and show a color change from yellowish to purple-brown during irradiation. The intensity of the color change depends on the type of UV radiation and is the highest for UVC (253.7 nm). It has been shown that the developed dosimeters (i) can be used for UVC radiation dose measurements in the range of up to 10 J/cm2; (ii) can be measured in 2D using a flatbed scanner; and (iii) can have the obtained images after scanning be filtered with a medium filter to improve their quality by reducing noise from the fabric structure. The developed cotton-NBT dosimeters can measure UVC-absorbed radiation doses on objects of various shapes, and when combined with a dedicated computer software package and a data processing method, they form a comprehensive system for measuring dose distributions for objects with complex shapes. The developed system can also serve as a comprehensive method for assessing the quality and control of UV radiation sources used in various industrial processes.

2.
Bioengineering (Basel) ; 11(9)2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39329605

RESUMEN

Whole-spine radiography can be accomplished through two methods: (1) segmented imaging employing X-ray tube angulation and detectors, or (2) the Euronext Paris Advanced Orthopedic Solutions (EOS) 2D Imaging system that can capture the entire spine in a single image using X-ray tubes and detectors oriented at a 90-degree angle. This study aimed to establish optimal EOS examination parameters based on patient morphotype and scan speed to reduce patient radiation exposure, repeat examinations, heat stress on equipment, and X-ray tube cooling time. X-ray exposure conditions involved adjustments of scan speed ranging from two to four steps, contingent upon the patient's morphotype ('S', small body; 'M', medium body; and 'L', large body. Patient dose measurements were conducted 20 times for each set of conditions. When transitioning from an 'S' to an 'M' morphotype at a constant scan speed, the entrance skin dose (ESD) exhibited an increase of approximately 41.25 ± 4.57%. A similar change from an 'M' to an 'L' morphotype resulted in an ESD increase of roughly 59.56 ± 24.00%. A transition from an 'S' to an 'L' morphotype at the same scan speed manifested an ESD elevation of approximately 124.21 ± 26.96%. This study underscores significant variations in radiation dose, ranging from 40% to 50%, when altering morphotype while maintaining a consistent scan speed.

3.
Radiol Phys Technol ; 2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39249637

RESUMEN

This study investigated the effectiveness of placing skin-ring structures to enhance the precision of skin dose calculations in patients who had undergone head and neck volumetric modulated arc therapy using the Acuros XB algorithm. The skin-ring structures in question were positioned 2 mm below the skin surface (skin A) and 1 mm above and below the skin surface (skin B) within the treatment-planning system. These structures were then tested on both acrylic cylindrical and anthropomorphic phantoms and compared with the Gafchromic EBT3 film (EBT3). The results revealed that the maximum dose differences between skins A and B for the cylindrical and anthropomorphic phantoms were approximately 12% and 2%, respectively. In patients 1 and 2, the dose differences between skins A and B were 9.2% and 8.2%, respectively. Ultimately, demonstrated that the skin-dose calculation accuracy of skin B was within 2% and did not impact the deep organs.

4.
Radiography (Lond) ; 30(5): 1405-1410, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38955646

RESUMEN

INTRODUCTION: Radiotherapy is the standard treatment for breast cancer patients after surgery. However, radiotherapy can cause side effects such as dry and moist desquamation of the patient's skin. The dose calculation from a treatment planning system (TPS) might also be inaccurate. The purpose of this study is to measure the surface dose on the CIRS thorax phantom by an optically stimulated luminescent dosimeter (OSLD). METHODS: The characteristics of OSLD were studied in terms of dose linearity, reproducibility, and angulation dependence on the solid water phantom. To determine the surface dose, OSLD (Landauer lnc., USA) was placed on 5 positions at the CIRS phantom (Tissue Simulation and Phantom Technology, USA). The five positions were at the tip, medial, lateral, tip-medial, and tip-lateral. Then, the doses from OSLD and TPS were compared. RESULTS: The dosimeter's characteristic test was good. The maximum dose at a depth of 15 mm was 514.46 cGy, which was at 100%. The minimum dose at the surface was 174.91 cGy, which was at 34%. The results revealed that the surface dose from TPS was less than the measurement. The percent dose difference was -2.17 ± 6.34, -12.08 ± 3.85, and -48.71 ± 1.29 at the tip, medial, and lateral positions, respectively. The surface dose from TPS at tip-medial and tip-lateral was higher than the measurement, which was 12.56 ± 5.55 and 10.45 ± 1.76 percent dose different, respectively. CONCLUSION: The percent dose difference is within the acceptable limit, except for the lateral position because of the body curvature. However, OSLD is convenient to assess the radiation dose, and further study is to measure in vivo. IMPLICATION FOR PRACTICE: The OSL NanoDot dosimeter can be used for dose validation with a constant setup location. The measurement dose is higher than the dose from TPS, except for some tilt angles.


Asunto(s)
Dosimetría con Luminiscencia Ópticamente Estimulada , Fantasmas de Imagen , Humanos , Dosimetría con Luminiscencia Ópticamente Estimulada/instrumentación , Dosimetría con Luminiscencia Ópticamente Estimulada/métodos , Reproducibilidad de los Resultados , Dosificación Radioterapéutica , Dosímetros de Radiación
5.
Biomed Phys Eng Express ; 10(4)2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38714180

RESUMEN

Radiotherapy (RT) is one of the major treatment modalities among surgery and chemotherapy for carcinoma breast. The surface dose study of modified reconstructive constructive Mastectomy (MRM) breast is important due to the heterogeneity in the body contour and the conventional treatment angle to save the lungs and heart from the radiation. These angular entries of radiation beam cause an unpredictable dose deposition on the body surface, which has to be monitored. Thermoluminescent dosimeter (TLD) or optically stimulated luminescent dosimeter (nano OSLD) are commonly preferable dosimeters for this purpose. The surface dose response of TLD and nano OSLD during MRM irradiation has been compared with the predicted dose from the treatment planning system (TPS). The study monitored 100 MRM patients by employing a total 500 dosimeters consisting of TLD (n = 250) and nano OSLD (n = 250), during irradiation from an Elekta Versa HD 6 MV Linear accelerator. The study observed a variance of 3.9% in the dose measurements for TLD and 3.2% for nano OSLD from the planned surface dose, with a median percentage dose of 44.02 for nano OSLD and 40.30 for TLD (p value 0.01). There was no discernible evidence of variation in dose measurements attributable to differences in field size or from patient to patient. Additionally, no variation was observed in dose measurements when comparing the placement of the dosimeter from central to off-centre positions. In comparison, a minor difference in dose measurements were noted between TLD and nano OSLD, The study's outcomes support the applicability of both TLD and nano OSLD as effective dosimeters during MRM breast irradiation for surface dose evaluation.


Asunto(s)
Neoplasias de la Mama , Mastectomía , Dosificación Radioterapéutica , Dosimetría Termoluminiscente , Humanos , Femenino , Dosimetría Termoluminiscente/métodos , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/cirugía , Planificación de la Radioterapia Asistida por Computador/métodos , Dosimetría con Luminiscencia Ópticamente Estimulada/métodos , Persona de Mediana Edad , Dosis de Radiación , Adulto , Mama/efectos de la radiación , Mama/cirugía
6.
Med Phys ; 51(8): 5746-5753, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38346088

RESUMEN

BACKGROUND: Surface dose in megavoltage photon radiotherapy has a significant clinical impact on the skin-sparing effect. In previously published works, it was established that the presence of medium atomic number (Z) absorbers, such as tin, decreases the surface dose. It was concluded that high-Z absorbers, such as lead, increase the surface dose, relative to medium-Z absorbers, due to the increased contributions from photoelectrons and electron-positron pairs. PURPOSE: The purpose of this investigation is to revisit these conclusions in the context of photon beams from modern linacs. METHODS: A metric estimating the relative intensity of charged particles emitted in the forward direction, I f ${I}_f$ , was proposed using cross-sections for the photon interactions. The I f ${I}_f$ values were calculated for various absorbers using energy spectra of 6 and 10 MV photon beams from a Varian TrueBeam linac. Monte Carlo (MC) simulations were performed using TOPAS MC code to calculate the surface dose for various absorbers. Surface dose measurements were performed with 6 and 10 MV photon beams with tin and lead absorbers. RESULTS: The I f ${I}_f$ values were found to decrease as a function of Z for both 6 and 10 MV photon beams indicating that the surface dose from electrons emitted in the forward direction consistently decreases with increasing Z. With the increasing Z of the absorbers, both experimental and MC-calculated surface dose decreased without exhibiting a minimum at medium-Z absorbers. The surface dose for lead and tin was determined to be within 1% of each other for both 6 and 10 MV photon beams using MC simulations and experimental measurements. Therefore, no statistically significant difference in surface dose was found between the tin and lead absorbers disproving the presence of any minima in the surface dose versus the Z curve as has been reported in the literature. CONCLUSIONS: Surface dose for modern photon beams can be reduced using both medium and high Z absorbers since a consistent decrease in surface dose was found with increasing absorber Z.


Asunto(s)
Método de Montecarlo , Fotones , Fotones/uso terapéutico , Dosificación Radioterapéutica , Dosis de Radiación , Aceleradores de Partículas , Radioterapia de Alta Energía/métodos
7.
Asian Pac J Cancer Prev ; 24(12): 4133-4138, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-38156848

RESUMEN

PURPOSE/OBJECTIVE: The purpose of this study is to investigate the effect of treatment couch and immobilization devices on surface dose for megavoltage photon beams. MATERIAL/METHODS: Percentage surface dose (PSD) measurement was carried out in Elekta Synergy™ Linear accelerator using PTW Markus® Parallel plate ionization chamber of volume 0.05cm3 with water equivalent RW3 Slab phantom (PTW, Germany). The measurement depth was considered at 0.07mm. The reference PSD was measured at 0° gantry angle with 10×10cm2, 20×20cm2 and 30×30cm2 field sizes and 100cm SSD for 4MV, 6MV and 15MV photon beams. For comparison, PSD measurement was carried out at 180° gantry angle inclusion of treatment couch (TC), All in One positioning system (AIO - PS) and Vac lok Cushions (VLC). RESULTS: Beam angle at 0°, for field sizes 10×10cm2, 20×20cm2 and 30×30cm2, the PSD was observed as 30.9%, 40.5%, 48.7% for 4MV; 23.7%, 33.8%, 42.2% for 6MV; and 17.0%, 29.6%, 38.6% for 15MV respectively. Beam angle at 180° with TC, an increase in PSD by maximum of 65.0% for 4MV, 64.9% for 6MV and 55.9% for 15MV as compared to 0° angle. The PSD increased when beam angle was 180° with TC and AIO - PS were 65.0% for 4MV, 67.4% for 6MV, and 60.9% for 15MV than 0° angle. Similarly, increased PSD for beam angle at 180° with TC and VLC were 66.8% for 4MV, 66.8% for 6MV and 61.3% for 15MV as compared to 0° angle. CONCLUSION: For all three-photon energies, at 180° gantry angle, the PSD increased significantly in case of TC, VLC, and AIO - PS for all the field sizes as compared to gantry angle at 0°. It is necessary to consider TC, AIO - PS and VLC during dose calculation to ensure accuracy of patient treatment delivery.


Asunto(s)
Fotones , Planificación de la Radioterapia Asistida por Computador , Humanos , Fotones/uso terapéutico , Fantasmas de Imagen , Aceleradores de Partículas , Agua , Dosificación Radioterapéutica
8.
Med Biol Eng Comput ; 61(8): 2197-2205, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37380785

RESUMEN

In this study, a newly developed capacitor dosimeter was evaluated using electron beams commonly utilized in radiotherapy. The capacitor dosimeter comprised a silicon photodiode, 0.47-µF capacitor, and dedicated terminal (dock). Before electron beam irradiation, the dosimeter was charged using the dock. The doses were measured without using a cable by reducing the charging voltages using the currents from the photodiode during irradiation. A commercially available parallel-plane-type ionization chamber and solid-water phantom were used for dose calibration with an electron energy of 6 MeV. In addition, the depth doses were measured using a solid-water phantom at electron energies of 6, 9, and 12 MeV. The doses were proportional to the discharging voltages, and the maximum dose difference in the calibrated doses measured using a two-point calibration was approximately 5% in the range of 0.25-1.98 Gy. The depth dependencies at energies of 6, 9, and 12 MeV corresponded to those measured using the ionization chamber.


Asunto(s)
Electrones , Silicio , Dosímetros de Radiación , Fantasmas de Imagen , Agua , Dosificación Radioterapéutica , Radiometría
9.
J Radiat Res ; 64(4): 644-650, 2023 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-37280131

RESUMEN

In volumetric modulated arc therapy (VMAT), the effect of an increase in skin surface dose due to topical agents might be negligible. We investigated the bolus effects of three types of topical agents in VMAT for head and neck cancer (HNC). Topical agents of different thicknesses (0.1, 0.5 and 2 mm) were prepared. When each topical agent was set, the surface doses were measured for the anterior static field and VMAT, with and without a thermoplastic mask. No significant differences were observed among the three topical agents. For topical agent thicknesses of 0.1, 0.5 and 2 mm, the increases in surface dose for the anterior static field without the thermoplastic mask were 7-9, 30-31 and 81-84%, respectively. With the thermoplastic mask, the corresponding increases were 5, 12-15 and 41-43%, respectively. The increases in surface dose for VMAT without the thermoplastic mask were 5-8, 16-19 and 36-39%, respectively, and those with the thermoplastic mask were 4, 7-10 and 15-19%, respectively. The rate of increase in surface dose with the thermoplastic mask was smaller than that without the thermoplastic mask. The increase in surface dose with topical agents of clinical standard thickness (0.02 mm) was estimated to be 2% with the thermoplastic mask. The increase in surface dose with topical agents in dosimetric simulation, compared with control situation, is not significant in clinical conditions for HNC patients.


Asunto(s)
Neoplasias de Cabeza y Cuello , Radioterapia de Intensidad Modulada , Humanos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Neoplasias de Cabeza y Cuello/radioterapia , Radiometría
10.
Diagn Interv Radiol ; 29(3): 555-560, 2023 05 31.
Artículo en Inglés | MEDLINE | ID: mdl-37129301

RESUMEN

PURPOSE: The purpose of this study was to evaluate the effect of outside-field-of-view (FOV) lead shielding on the entrance surface dose (ESD) of the breast on an anthropomorphic X-ray phantom for a variety of axial skeleton X-ray examinations. METHODS: Using an anthropomorphic phantom and radiation dosimeter, the ESD of the breast was measured with and without outside-FOV shielding in anterior-posterior (AP) abdomen, AP cervical spine, occipitomental 30° (OM30) facial bones, AP lumbar spine, and lateral lumbar spine radiography. The effect of several exposure parameters, including a low milliampere-seconds technique, grid use, automatic exposure control use, wraparound lead (WAL) use, trolley use, and X-ray table use, on the ESD of the breast with and without outside-FOV shielding was investigated. The mean ESD (µSv) and standard deviation for each radiographic protocol were calculated. A one-tailed Student's t-test was carried out to evaluate whether ESD to the breast was reduced with the use of outside-FOV shielding. RESULTS: A total of 920 breast ESD measurements were recorded across the different protocol parameters. The largest decrease in mean ESD of the breast with outside-FOV shielding was 0.002 µSv (P = 0.084), recorded in the AP abdomen on the table with a grid, OM30 on the table with a grid, OM30 standard protocol on the trolley, and OM30 on the trolley with WAL protocols. This decrease was found to be statistically non-significant. CONCLUSION: This study found no significant decrease in the ESD of the breast with the use of outside-FOV shielding for the AP abdomen, AP cervical spine, OM30 facial bones, AP lumbar spine, or lateral lumbar spine radiography across a range of protocols.


Asunto(s)
Vértebras Lumbares , Tórax , Humanos , Rayos X , Dosis de Radiación , Radiografía , Fantasmas de Imagen
11.
Sensors (Basel) ; 23(7)2023 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-37050532

RESUMEN

This study evaluated the effect of pitch on 256-slice helical computed tomography (CT) scans. Cylindrical water phantoms (CWP) were measured using axial and helical scans with various pitch values. The surface dose distributions of CWP were measured, and reconstructed images were obtained using filtered back-projection (FBP) and iterative model reconstruction (IMR). The image noise in each reconstructed image was decomposed into a baseline component and another component that varied along the z-axis. The baseline component of the image noise was highest at the center of the reconstructed image and decreased toward the edges. The normalized 2D power spectra for each pitch were almost identically distributed. Furthermore, the ratios of the 2D power spectra for IMR and FBP at different pitch values were obtained. The magnitudes of the components varying along the z-axis were smallest at the center of the reconstructed image and increased toward the edge. The ratios of the 3D power spectra on the fx axis for IMR and FBP at different pitch values were obtained. The results showed that the effect of the pitch was related to the component that varied along the z-axis. Furthermore, the pitch had a smaller effect on IMR than on FBP.


Asunto(s)
Interpretación de Imagen Radiográfica Asistida por Computador , Tomografía Computarizada por Rayos X , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Estudios Prospectivos , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen , Dosis de Radiación , Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos
12.
Artículo en Inglés | MEDLINE | ID: mdl-37101538

RESUMEN

The emergence of the Halcyon linear accelerator has allowed for increased patient throughput and improved treatment times for common treatment sites in radiation oncology. However, it has been shown that this can lead to increased surface dose in sites like breast cancer compared with treatments on conventional machines with flattened radiation beams. Cherenkov imaging can be used to estimate surface dose by detection of Cherenkov photons emitted in proportion to energy deposition from high energy electrons in tissue. Phantom studies were performed with both square beams in reference conditions and with clinical treatments, and dosimeter readings and Cherenkov images report higher surface dose (25% for flat phantom entrance dose, 5.9% for breast phantom treatment) from Halcyon beam deliveries than for equivalent deliveries from a TrueBeam linac. Additionally, the first Cherenkov images of a patient treated with Halcyon were acquired, and superficial dose was estimated.

13.
Appl Radiat Isot ; 197: 110797, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37043867

RESUMEN

A framework has been developed for dosimetric evaluation in mammography, using the GATE Monte Carlo (MC) platform, to simulate a MAMMOMAT 3000 Nova mammograph (Siemens) available at the University Hospital Center "1st November 1954" of Oran (EHU Oran 1er Novembre, 1954), Algeria. Calculated quantities such half-value layer (HVL), Entrance Surface Dose (ESD) and Mean Glandular Dose (MGD) have been compared to experimental data in order to validate the modeling of mammography examinations. Results are consistent with previous studies and show a good agreement between measurements and Monte Carlo calculations. By varying the tube voltage from 25 to 35 kV, we have estimated an increasing of a factor of 2.4 in ESD, and a factor of 2.75 for the MGD in a breast phantom. Furthermore, the current intensity of 100 mAs used for a beam quality combination (Mo/Mo) Anode/filter was found suitable for the tube voltages of 25-29 keV since the MGD does not exceed the limits set by the different quality insurance protocols. This GATE dose calculation framework thus provides a very useful tool for the optimization of mammography examinations at Oran hospital by allowing a better estimation of the dose delivered to patients according to the parameters of the examination.


Asunto(s)
Mama , Mamografía , Humanos , Mamografía/métodos , Mama/diagnóstico por imagen , Radiometría , Método de Montecarlo , Fantasmas de Imagen , Hospitales , Dosis de Radiación
14.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 79(5): 453-461, 2023 May 20.
Artículo en Japonés | MEDLINE | ID: mdl-36927669

RESUMEN

PURPOSE: To investigate fundamental dosimetric properties of surface dose, exit dose, and beam profile of the brass mesh bolus for 4, 6, and 10 MV high-energy photon beams in radiation therapy. METHODS: Surface dose and exit dose in the water-equivalent phantom were measured, and percent depth doses (PDDs) were calculated with no bolus, one layer of brass mesh, two layers of brass mesh bolus, three layers of brass mesh bolus, and 0.5 cm tissue-equivalent (TE) bolus. Exit dose was measured at a phantom thickness of 10 cm. Beam profiles were measured at phantom depths of 0 cm and 10 cm. All dosimetry was performed for 4, 6, and 10 MV photon beams using a linear accelerator. RESULTS: The surface dose at a phantom depth of 0 cm increased to 37.3%, 36.3%, and 31.0% for 4, 6, and 10 MV, respectively, with the brass mesh bolus compared to the case of no bolus. The surface dose decreased with one layer of brass mesh bolus compared to that with the 0.5 cm TE bolus. On the other hand, the exit dose increased to 22.0%, 23.1%, and 22.8% for 4, 6, and 10 MV, respectively, with the brass mesh bolus compared to the case of no bolus. The beam profile at the depth of 0 cm showed oscillations, and the difference between the maximum and minimum doses was up to 13.1% with one layer of brass mesh bolus. CONCLUSION: It was suggested that the brass mesh bolus not only increases the surface dose but also has different properties from the conventional TE bolus.


Asunto(s)
Radiometría , Mallas Quirúrgicas , Cobre , Zinc , Dosificación Radioterapéutica
15.
Radiography (Lond) ; 29(3): 573-576, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36996507

RESUMEN

INTRODUCTION: When the patient dose in mammography is assessed, it is important to evaluate both average glandular dose (AGD) and entrance surface dose (ESD). A dose survey on both AGD and ESD in mammography has never been studied in Sri Lanka. Therefore, the present study aimed to evaluate the patient dose received during a full-field digital breast tomosynthesis (DBT) examination by determining both AGD and ESD. METHODS: The study was performed on 140 patients who underwent DBT examination. The AGD, ESD, compression breast thickness (CBT), half-value layer (HVL), target/filter combination, kVp, and mAs values were obtained from the machine, and AGD for each projection was calculated using the equation proposed by the Dance 2011. RESULTS: The measured mean AGDs and ESDs of both the breasts were statistically significantly lower than the reference values given by European protocol (p < 0.05). There were no statistically significant differences in both AGDs and ESDs between the right and left breast, between right craniocauidal (RCC) and left craniocaudal (LCC), and between right mediolateral oblique (RMLO) and left mediolateral oblique (LMLO) examinations (p > 0.05). The measured median AGDs and ESDs received for MLO projections of both breasts were statistically significantly higher than that of CC projections (p < 0.05). CONCLUSION: The patients receive a low radiation dose during their DBT examination with both lowered AGD and ESD than the recommended values. IMPLICATIONS FOR PRACTICE: The results can be used as a baseline to optimize the radiation dose in mammography in Sri Lanka.


Asunto(s)
Mamografía , Intensificación de Imagen Radiográfica , Humanos , Dosis de Radiación , Intensificación de Imagen Radiográfica/métodos , Mamografía/métodos , Mama/diagnóstico por imagen , Examen Físico
16.
Phys Med Biol ; 68(5)2023 02 23.
Artículo en Inglés | MEDLINE | ID: mdl-36753768

RESUMEN

Purpose. To address the shortcomings of current procedures for evaluating the measured-to-planned dose agreement inin vivodosimetry (IVD), this study aimed to develop an accurate and efficient novel framework to identify the detector location placed on a patient's skin surface using a 3D camera and determine the planned dose at the same anatomical position corresponding to the detector location.Methods. Breast cancer treatment was simulated using an anthropomorphic adult female phantom (ATOM 702D; CIRS, Norfolk, VA, USA). An optically stimulated luminescent dosimeter was used for surface dose measurements (MyOSLchip, RadPro International GmbH, Germany) at six IVD points. Three-dimensional surface imaging (3DSI) of the phantom with the detector was performed in the treatment position using a 3D camera. The developed framework, iSMART, was designed to import 3DSI and treatment planning data for determining the position of the IVD detectors in the 3D treatment planning DICOM image. The clinical usefulness of iSMART was evaluated in terms of accuracy and efficiency, for comparison with the results obtained using cone-beam computed tomography (CBCT) image guidance.Results. The relative dose difference between the planned doses determined using iSMART and CBCT images displayed similar accuracies (within approximately ±2.0%) at all detector locations. The relative dose differences between the planned and measured doses at the six detector locations ranged from -4.8% to 3.1% for the CBCT images and -3.5% to 2.1% for iSMART. The total time required to read the planned doses at six detector locations averaged at 8.1 and 0.8 min for the CBCT images and iSMART, respectively.Conclusions. The proposed framework can improve the robustness of IVD analyses and aid in accurate and efficient evaluations of the measured-to-planned dose agreement.


Asunto(s)
Neoplasias de la Mama , Radiometría , Adulto , Humanos , Femenino , Radiometría/métodos , Tomografía Computarizada de Haz Cónico/métodos , Modelos Teóricos , Dosímetros de Radiación , Fantasmas de Imagen
17.
J Appl Clin Med Phys ; 24(2): e13884, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36546565

RESUMEN

Numerous medical conditions are associated with pregnancy in women, including pulmonary thromboembolism, which can be fatal. An effective treatment of this condition is the positioning of an inferior vena cava filter (IVC-F) under the guidance of X-ray imaging. However, this procedure involves the risk of high radiation exposure to pregnant women and fetuses. Moreover, there are no published reports comparing the values of fetal dose, received during IVC-F placement in pregnant women, determined using dose calculation software and actual measurements. To address this issue, we compared the fetal radiation dose and entrance surface dose (ESD) for pregnant women for gestation periods of 6 and 9 months based on software calculations and actual measurements. The ESD and fetal doses were estimated for a pregnant woman for gestation periods of 6 and 9 months during IVC-F placement. For actual measurements, one pregnant model phantom was constructed using an anthropomorphic phantom, and two custom-made different-sized abdomen phantoms were used to simulate pregnancy. The custom-made abdomen phantoms were constructed using polyurethane. For software calculations, the software utilized a set of anatomically realistic pregnant patient phantoms. The ESD estimated using the software was consistent with the measured ESD, but the fetal dose estimations were more complicated due to fetal positioning. During fetal dose evaluation using software calculations, the user must carefully consider how much of the fetal length is in the irradiation field to prevent underestimation or overestimation. Despite the errors, the software can assist the user in identifying the magnitude of the dose approaching critical limits.


Asunto(s)
Exposición a la Radiación , Filtros de Vena Cava , Femenino , Embarazo , Humanos , Radiometría , Dosis de Radiación , Programas Informáticos , Fantasmas de Imagen
18.
Ethiop J Health Sci ; 32(Spec Iss 1): 11-16, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36339954

RESUMEN

Background: Early childhood radiation exposure carries an enhanced radiation risk of about two to three times as high as in adults. The objective of this study was to determine local diagnostic reference levels for the most frequent pediatric x-ray examinations in Addis Ababa, Ethiopia. Methods: A cross-sectional study was conducted on 18 public and private hospitals/clinics in Addis Ababa. A total of 864 pediatric patients, undergoing eight types of routine x-ray examinations with 13 projections were evaluated from December 18/2017 to March 17 /2018. All pediatrics were categorized under four age groups. Anthropometric and radiographic parameters of each patient were recorded .The minimum, maximum, mean and third quartile values of entrance surface dose were analyzed using SPSS version 23. Finally, the suggested local diagnostic reference levels were compared with national and international reference dose values. Results: Of the 864 pediatric patients, chest (AP/PA), lower and upper extremity (AP/PA) accounted for 501(58%), 110 (13%) and 103 (12%) respectively, accounting to 714(83%) of the total pediatric x-ray examinations. The suggested local diagnostic reference levels of chest X-ray (AP/PA) examinations in mGy were: (0.09,0.13,0.17,0.17) for age group (0-<1,1-<5 ,5-<10, and 10-<15), respectively. Similarly, for same age group (0-<1,1-<5 ,5-<10, and 10-<15) the suggested local diagnostic reference levels of lower and upper extremities in mGy were: (0.06,0.08,0.09,0.09) and (0.04,0.05,0.05,0.06), respectively. Conclusion: The suggested local diagnostic reference levels were slightly higher than the national and international guidance levels, indicating the need for establishment of diagnostic reference levels in the country.


Asunto(s)
Niveles de Referencia para Diagnóstico , Pediatría , Adulto , Niño , Humanos , Preescolar , Dosis de Radiación , Rayos X , Estudios Transversales , Etiopía
19.
J Contemp Brachytherapy ; 14(4): 370-378, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36199944

RESUMEN

Purpose: Intra-operative radiotherapy (IORT) has been used as a tool to provide a high-dose radiation boost to a limited volume of patients with fixed tumors with a likelihood of microscopically involved resection margins, in order to improve local control. Two main techniques to deliver IORT include high-dose-rate (HDR) brachytherapy, termed 'intra-operative brachytherapy' (IOBT), and electrons, termed 'intra-operative electron radiotherapy' (IOERT), both having very different dose distributions. A recent paper described an improved local recurrence-free survival favoring IOBT over IOERT for patients with locally advanced or recurrent rectal cancer and microscopically irradical resections. Although several factors may have contributed to this result, an important difference between the two techniques was the higher surface dose delivered by IOBT. This article described an adaptation of IOERT technique to achieve a comparable surface dose as dose delivered by IOBT. Material and methods: Two steps were taken to increase the surface dose for IOERT: 1. Introducing a bolus to achieve a maximum dose on the surface, and 2. Re-normalizing to allow for the same prescribed dose at reference depth. Conclusions: We describe and propose an adaptation of IOERT technique to increase surface dose, decreasing the differences between these two techniques, with the aim of further improving local control. In addition, an alternative method of dose prescription is suggested, to consider improved comparison with other techniques in the future.

20.
J Med Phys ; 47(2): 173-180, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36212207

RESUMEN

Purpose: The aim of the current study is to commission compensator-based total body irradiation (TBI) and to compare surface dose using percentage depth dose (PDD) while varying the distance between beam spoiler and phantom surface. Materials and Methods: TBI commissioning was performed on Elekta Synergy® Platform linear accelerator for bilateral extended source to surface distance treatment technique. The PDD was measured by varying the distance (10 cm, 20 cm, 30 cm, and 40 cm) between the beam spoiler and the phantom surface. Beam profile and half-value layer (HVL) measurement were carried out using the FC65 ion-chamber. Quality assurance (QA) was performed using an in-house rice-flour phantom (RFP). In-vivo diodes (IVD) were placed on the RFP at various regions to measure the delivered dose, and it was compared to the calculated dose. Results: An increase in Dmax and surface dose was observed when beam spoiler was moved away from the phantom surface. The flatness and symmetry of the beam profile were calculated. The HVL of Perspex and aluminum is 17 cm and 8 cm, respectively. The calculated dose of each region was compared to the measured dose on the RFP with IVD, and the findings showed that the variation was <4.7% for both Perspex and Aluminum compensators. Conclusion: The commissioning of the compensator-based TBI technique was performed and its QA measurements were carried out. The Mayneord factor corrected PDD and measured PDD values were compared. The results are well within the clinical tolerance limit. This study concludes that 10 cm -20 cm is the optimal distance from the beam spoiler to phantom surface to achieve prescribed dose to the skin.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...