Life (Basel) ; 14(10)2024 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-39459626

RESUMEN

Fractional flow reserve (FFR) is regarded as the gold standard for assessing the functional significance of coronary artery lesions. However, its utilization in clinical practice remains limited. This study aims to determine whether FFR results can influence treatment decisions for coronary artery disease compared to visual assessments of angiographic images. We conducted a retrospective study involving 63 patients diagnosed with either chronic coronary syndrome (n = 39, 61.9%) or acute coronary syndrome (n = 24, 38.1%) who underwent an FFR assessment. Three experienced interventional cardiologists (>300 PCI procedures/year) reevaluated 105 ambiguous coronary lesions in these patients, blinded to the FFR results. The objective was to assess lesion significance and determine the treatment strategy based on a visual angiographic evaluation. The three operators reached concordant agreement (≥two operators) to perform PCI in 60 (57.1%) of the evaluated lesions based on the angiographic assessment. Of these, nine lesions (15%) were deemed functionally non-significant by FFR (FFR > 0.80). Conversely, they agreed to defer PCI in 45 (42.9%) lesions, but 4 lesions (8.9%) were found to be functionally significant (FFR ≤ 0.80) and required a re-evaluation for PCI. Visual-guided decision making by interventional cardiologists shows variability and does not always align with the functional significance of coronary lesions as determined by FFR. Incorporating FFR into routine decision making could enhance treatment accuracy and patient outcomes.

2.
J Midlife Health ; 15(2): 69-74, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39145263

RESUMEN

Introduction: Colposcopy is important for triaging any abnormal cervical screening test. Scarcity of trained colposcopists and colposcopy centers is a big hurdle to screening programs in low- and middle-income countries. Objectives of the Study: The objective was to assess the performance of the artificial intelligence incorporated into the mobile optical device technologies (ODT) Enhanced Visual Assessment (EVA visual check) against physician colposcopic diagnosis and the gold standard of histopathology. Materials and Methods: It was a cross-sectional observational study conducted on women referred to a colposcopy clinic following an abnormal screening test. Colposcopic examination was performed by colposcopists using the MobileODT EVA system. Physician's impression and Visual Check analysis were compared with the final histopathological analysis or cytology. Cases with normal cytology and normal colposcopy did not undergo biopsy, and these were considered normal. Results: A total of 2050 women were screened, and 147 screen-positive women were recruited in the study. EVA Visual Check had a sensitivity of 86.8% (75-95), specificity of 28.7% (20-39), positive predictive value (PPV) of 40.7% (32-50), negative predictive value (NPV) of 79.4% (62-91), and diagnostic accuracy of 49.7% (41-58) for diagnosing cervical intraepithelial neoplasia (CIN) 1+ lesions. EVA Visual Check has a sensitivity of 89.3% (72-98), specificity of 26.1% (18-35), PPV of 22.1% (15-31), NPV of 91.2% (76-98), and diagnostic accuracy of 38.1% (30-46) for CIN 2+ lesions. Conclusion: MobileODT EVA colposcope with AI has sensitivity comparable to physician's diagnosis, whereas specificity, PPV, and NPV were less than that of physician's diagnosis. It could prove valuable for triage of screen-positive women for further management.

3.
Cytojournal ; 21: 17, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38887694

RESUMEN

Objective: The simplest way to determine the adequacy of aspirated materials is the on-site gross visual assessment of aspirated materials. However, few studies have examined the gross findings of thyroid aspirates. This study aimed to clarify the diagnostic significance of clay-like material aspirated from thyroid nodules. Material and Methods: We reviewed 69,848 thyroid nodules that underwent aspiration cytology at Kuma Hospital between January 2007 and August 2021. Among them, 355 (0.5%) nodules with aspirated materials described as clay-like materials were retrospectively examined. Results: Among 355 nodules, 322 (90.7%) were categorized as cystic fluid or benign. The aspirated materials were mainly composed of non-epithelial components, including colloid or proteinaceous materials, foamy histiocytes, and degenerative red blood cells. In original ultrasound reports, the incidence of intermediate and high suspicion was 11.0%. Malignant cells were observed in 21 nodules (5.9%), one-third of which were papillary thyroid carcinomas. The materials aspirated from papillary and follicular thyroid carcinomas exhibited necrotic carcinoma cells derived from infarcted areas. The overall risk of malignancy was 3.9%. The risk of malignancy in nodules interpreted as highly suspicious on ultrasound examination was 37.5%. Conclusion: As clay-like materials aspirated from thyroid nodules were considered sufficient specimens, the recognition contributes to avoiding unnecessary second punctures. The presence of clay-like materials was indicative of the colloid and/or blood components of benign cystic lesions, or, more rarely, of infarcted carcinoma. The ultrasound examination results tended to overestimate nodules. We should reaffirm that on-site gross visual assessment of aspirated materials is a fast and reasonably accurate predictor of the on-site adequacy of the samples.

4.
Burns ; 50(6): 1586-1596, 2024 08.
Artículo en Inglés | MEDLINE | ID: mdl-38641499

RESUMEN

BACKGROUND: The purpose of dermal substitutes is to mimic the basic properties of the extracellular matrix of human skin. The application of dermal substitutes to the defect reduces the formation of hypertrophic scars and improves the scar quality. This study aims to develop an original dermal substitute enriched with stable fibroblast growth factor 2 (FGF2-STAB®) and test it in an animal model. METHODS: Dermal substitutes based on collagen/chitosan scaffolds or collagen/chitosan scaffolds with nanofibrous layer were prepared and enriched with FGF2-STAB® at concentrations of 0, 0.1, 1.0, and 10.0 µg ‧ cm-2. The performance of these dermal substitutes was tested in vivo on artificially formed skin defects in female swine. The outcomes were evaluated using cutometry at 3 and 6 months. In addition, visual appearance was assessed based on photos of the scars at 1-month, 3-month and 6-month follow-ups using Yeong scale and Visual Analog Scale. RESULTS: The dermal substitute was fully integrated into all defects and all wounds healed successfully. FGF2-STAB®-enriched matrices yielded better results in cutometry compared to scaffolds without FGF2. Visual evaluation at 1, 3, and 6 months follow-ups detected no significant differences among groups. The FGF2-STAB® effectiveness in improving the elasticity of scar tissues was confirmed in the swine model. This effect was independently observed in the scaffolds with nanofibres as well as in the scaffolds without nanofibres. CONCLUSION: The formation of scars with the best elasticity was exhibited by addition 1.0 µg ‧ cm-2of FGF2-STAB® into the scaffolds, although it had no significant effect on visual appearance at longer follow-ups. This study creates the basis for further translational studies of the developed product and its progression into the clinical phase of the research.


Asunto(s)
Quitosano , Elasticidad , Factor 2 de Crecimiento de Fibroblastos , Piel Artificial , Animales , Porcinos , Femenino , Andamios del Tejido , Colágeno , Viscosidad , Cicatriz Hipertrófica , Quemaduras , Cicatrización de Heridas/efectos de los fármacos , Nanofibras/uso terapéutico , Modelos Animales de Enfermedad , Piel
5.
J Neurol ; 271(7): 4267-4280, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38632125

RESUMEN

OBJECTIVE: Frontal hypometabolism on FDG-PET is observed in progressive supranuclear palsy (PSP), although it is unclear whether it is a feature of all PSP clinical variants and hence whether it is a useful diagnostic feature. We aimed to compare the frequency, severity, and pattern of frontal hypometabolism across PSP variants and determine whether frontal hypometabolism is related to clinical dysfunction. METHODS: Frontal hypometabolism in prefrontal, premotor, and sensorimotor cortices was visually graded on a 0-3 scale using CortexID Z-score images in 137 PSP patients. Frontal asymmetry was recorded. Severity scores were used to categorize patients as premotor-predominant, prefrontal-predominant, sensorimotor-predominant, mixed-predominance, or no regional predominance. Frontal ratings were compared across PSP clinical variants, and Spearman correlations were used to assess relationships with the Frontal Assessment Battery (FAB). RESULTS: 97% showed evidence of frontal hypometabolism which was most common (100%) in the speech-language (PSP-SL), corticobasal (PSP-CBS), and frontal (PSP-F) variants and least common in the progressive gait freezing (PSP-PGF) variant (73%). PSP-SL and PSP-CBS showed more severe hypometabolism than Richardson's syndrome (PSP-RS), Parkinsonism (PSP-P), and PSP-PGF. A premotor-predominant pattern was most common in PSP-SL and PSP-CBS, with more mixed patterns in the other variants. Hypometabolism was most commonly asymmetric in PSP-SL, PSP-P, PSP-F and PSP-CBS. Worse hypometabolism in nearly all frontal regions correlated with worse scores on the FAB. CONCLUSIONS: Frontal hypometabolism is a common finding in PSP, although it varies in severity and pattern across PSP variants and will likely be the most diagnostically useful in PSP-SL and PSP-CBS.


Asunto(s)
Lóbulo Frontal , Tomografía de Emisión de Positrones , Parálisis Supranuclear Progresiva , Humanos , Parálisis Supranuclear Progresiva/diagnóstico por imagen , Parálisis Supranuclear Progresiva/metabolismo , Femenino , Masculino , Anciano , Persona de Mediana Edad , Lóbulo Frontal/diagnóstico por imagen , Lóbulo Frontal/metabolismo , Fluorodesoxiglucosa F18 , Índice de Severidad de la Enfermedad , Anciano de 80 o más Años
6.
Breast Cancer ; 31(4): 671-683, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38619787

RESUMEN

BACKGROUND: Visual assessment of mammographic breast composition remains the most common worldwide, although subjective variability limits its reproducibility. This study aimed to investigate the inter- and intra-observer variability in qualitative visual assessment of mammographic breast composition through a multi-institutional observer performance study for the first time in Japan. METHODS: This study enrolled 10 Japanese physicians from five different institutions. They used the new Japanese breast-composition classification system 4th edition to subjectively evaluate the breast composition in 200 pairs of right and left normal mediolateral oblique mammograms (number determined using precise sample size calculations) twice, with a 1-month interval (median patient age: 59 years [range 40-69 years]). The primary endpoint of this study was the inter-observer variability using kappa (κ) value. RESULTS: Inter-observer variability for the four and two classes of breast-composition assessment revealed moderate agreement (Fleiss' κ: first and second reading = 0.553 and 0.587, respectively) and substantial agreement (Fleiss' κ: first and second reading = 0.689 and 0.70, respectively). Intra-observer variability for the four and two classes of breast-composition assessment demonstrated substantial agreement (Cohen's κ, median = 0.758) and almost perfect agreement (Cohen's κ, median = 0.813). Assessments of consensus between the 10 physicians and the automated software Volpara® revealed slight agreement (Cohen's κ; first and second reading: 0.104 and 0.075, respectively). CONCLUSIONS: Qualitative visual assessment of mammographic breast composition using the new Japanese classification revealed excellent intra-observer reproducibility. However, persistent inter-observer variability, presenting a challenge in establishing it as the gold standard in Japan.


Asunto(s)
Neoplasias de la Mama , Mamografía , Variaciones Dependientes del Observador , Humanos , Persona de Mediana Edad , Femenino , Mamografía/métodos , Adulto , Japón , Anciano , Reproducibilidad de los Resultados , Neoplasias de la Mama/diagnóstico por imagen , Mama/diagnóstico por imagen , Mama/patología , Médicos , Densidad de la Mama
7.
Front Plant Sci ; 15: 1343632, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38584948

RESUMEN

Potato tuber shape, size, and specific gravity are important agronomic traits in the russet market class of potatoes with an impact on quality, consistency, and product recovery of processed foods such as French fries. Therefore, identifying genetic regions associated with the three traits through quantitative trait locus/loci (QTL) analysis is a crucial process in the subsequent development of marker-assisted selection for use in potato breeding programs. QTL analysis was conducted on a tetraploid mapping population consisting of 190 individuals derived from the cross between two russet-skinned parents, Palisade Russet and the breeding clone ND028673B-2Russ. Field data collected over a 2-year period and used in the QTL analyses included tuber length-width and width-depth ratios that were obtained using a digital caliper. The width-depth ratio provided an assessment of the "flatness" of a tuber, which is of importance in potato processing. To cross-validate the accuracy and differences among tuber shape measurement methods, a trained evaluator also assessed the identical tubers based on 1-5 scale (compressed to long) visual assessment method. Furthermore, the weights of analyzed tubers and specific gravities were also collected during the phenotyping process for each mapping clone. A major tuber shape QTL was consistently observed on chromosome 10 with both the length-width ratio and visual assessments. On chromosome 4, a significant QTL for tuber shape from the visual assessment phenotypic data was also detected. Additionally, a tuber shape-related QTL on chromosome 6 was also detected from the length-width ratio data from 2020. Chromosome 2 was also identified as having a significant QTL for the width-depth ratio, which is of importance in influencing the flatness of a tuber. One significant QTL for tuber weight (i.e., tuber size) was observed on chromosome 5, and a significant QTL for specific gravity was found on chromosome 3. These significant and major QTL should be useful for developing marker-assisted selection for more efficient potato breeding.

8.
BMC Sports Sci Med Rehabil ; 16(1): 76, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38566260

RESUMEN

BACKGROUND: The Single Leg Squat (SLS) test is widely used in the clinical setting to examine and evaluate rehabilitation goals. It is simple to perform and is proposed to have biomechanical and neuromuscular similarities to athletic movements. The aim of the present study was to investigate whether demographics, previous injuries, and biomechanical and psychosocial factors are associated with the outcome of the SLS, assessed as a total score for all segments and as a separate knee segment in elite and sub-elite female soccer players. METHODS: We conducted a cross-sectional study involving 254 female soccer players (22 yrs; SD ± 4, height 1.69 m; SD ± 0.1, weight 64 kg; SD ± 6) from divisions 1-3 of the Swedish Soccer League. During the preseason, we assessed the participants using the SLS and tested their hip strength and ankle mobility. Demographics, previous injury, sleep quality, fear of movement, anxiety, and perceived stress were assessed with questionnaires. Logistic regression models were built to analyse the association between the outcome of the SLS and the independent variables for the dominant and non-dominant leg. RESULTS: Significantly more participants failed the SLS on the dominant leg compared with the non-dominant leg (p < 0.001). The outcome of the SLS associated with various biopsychosocial factors depending on if the dominant or non-dominant leg was tested. The total score associated with hip strength for the dominant (OR 0.99, 95% CI 0.98-0.99, p = 0.04) and the non-dominant leg (OR 0.99, 95% CI 0.97-0.99, p = 0.03). The knee segment associated with division level for the dominant (div 2; OR 2.34, 95% CI 1.01-5.12, p = 0.033. div 3; OR 3.07, 95% CI 1.61-5.85, p = 0.001) and non-dominant leg (div 2; OR 3.30, 95% CI 1.33-8.00, p = 0.01. div 3; OR 3.05, 95% CI 1.44-6.43, p = 0.003). CONCLUSIONS: This study identified that leg dominance, division level, hip strength, and psychosocial factors were associated with the outcome of the SLS when assessed as a total score and as a separate knee segment. This indicates that clinicians need to understand that movement control is associated with factors from several domains. Whether these factors and, the results of the SLS are related to injury need to be studied prospectively. TRIAL REGISTRATION: Clinical Trials Gov, date of registration 2022-03-01. CLINICAL TRIALS IDENTIFIER: NCT05289284A.

9.
Sci Prog ; 107(2): 368504241248004, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38683182

RESUMEN

Objectives: Discrimination of nasal cavity lesions using nasal endoscopy is challenging because of the differences in clinical manifestations and treatment strategies. We aimed to investigate the diagnostic accuracy of clinical visual assessment (CVA) of nasal cavity masses using endoscopic images and determine whether there is a difference according to pathologic class and the examiners' experience. Methods: We collected pathologically confirmed endoscopic images of normal findings, nasal polyp (NP), benign tumor, and malignant tumor (each class contained 100 images) randomly selected. Eighteen otolaryngologists, including six junior residents, six senior residents, and six board-certified rhinologists classified the test set images into four classes of lesions by CVA. Diagnostic performance according to the pathologic class and the examiner's experience level was evaluated based on overall accuracy, F1-score, confusion matrix, and area under the receiver operating characteristic curve (AUC). Results: Diagnostic performance was significantly different according to the pathological class of nasal cavity mass lesions with the overall accuracy reported high in the order of normal, NP, benign tumor, and malignant tumor (0.926 ± 0.100; 0.819 ± 0.135; 0.580 ± 0.112; 0.478 ± 0.187, respectively), F1 score (0.937 ± 0.076; 0.730 ± 0.093; 0.549 ± 0.080; 0.554 ± 0.146, respectively) and AUC value (0.96 ± 0.06; 0.84 ± 0.07; 0.70 ± 0.05; 0.71 ± 0.08, respectively). The expert rhinologist group achieved higher overall accuracy than the resident group (0.756 ± 0.157 vs. 0.680 ± 0.239, p < .05). Conclusion: CVA for nasal cavity mass was highly dependent on the pathologic class and examiner's experience. The overall accuracy was reliably high for normal findings, but low in classifying benign and malignant tumors. Differential diagnosis of lesions solely based on nasal endoscopic evaluation is challenging. Therefore, clinicians should consider further clinical evaluation for suspicious cases.


Asunto(s)
Endoscopía , Cavidad Nasal , Humanos , Cavidad Nasal/diagnóstico por imagen , Cavidad Nasal/patología , Endoscopía/métodos , Neoplasias Nasales/diagnóstico por imagen , Neoplasias Nasales/patología , Neoplasias Nasales/diagnóstico , Masculino , Pólipos Nasales/diagnóstico , Pólipos Nasales/diagnóstico por imagen , Pólipos Nasales/patología , Femenino , Curva ROC , Adulto , Persona de Mediana Edad
10.
Cureus ; 16(1): e51755, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38318547

RESUMEN

OBJECTIVE: To determine the diagnostic accuracy of smartphone thermal imaging for preoperative perforator mapping in perforator-based flaps, taking visual inspection as gold standard. METHODOLOGY: It was a cross-validation study conducted at the Department of Plastic Surgery, Dr. Ruth K. Pfau Civil Hospital, Karachi, Pakistan, from August 2022 to January 2023. All adult patients aged 18 to 40 years of either gender undergoing perforator flap surgery were included. Each patient followed the same treatment regimen, which involved the preoperative identification of the perforator location using the FLIR One camera. Subsequently, confirmation was achieved during the surgical procedure through visual inspection. A two-by two table was used to calculate sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy. RESULTS: The mean age of the patients was 30.10±6.87 years, ranging from 18 to 40 years. Most of the patients were males (58.7%), and 41.3% were females. Almost 80.4% were pedicle flaps, and 19.6% were free flaps. The accuracy of thermal imaging was found to be 83.2%, with a sensitivity of 84.3%, a specificity of 80%, a PPV of 92.9%, and a NPV of 62.2%, respectively. CONCLUSION: Smartphone-based thermal imaging is useful for the diagnosis of perforators and has high sensitivity and specificity.

11.
Indian J Pediatr ; 2024 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-38214829

RESUMEN

OBJECTIVES: To compare the performance of Modified Kramer's and Kramer's methods in terms of agreement with total serum bilirubin (TSB). METHODS: This cross-sectional study was done in Level-III neonatal unit in New Delhi. Visibly jaundiced neonates born at ≥35 wk of gestation were enrolled and examined by (i) conventional Kramer's, (ii) Modified Kramer's in artificial (MK-A) and (iii) natural daylight (MK-N), and finally sampled for estimation of TSB by point-of-care spectrophotometry. The primary outcomes were agreement of Kramer's and Modified Kramer's with TSB and accuracy in terms of proportion of bilirubin estimates lying within ±2 mg/dL of TSB; secondary outcome was agreement of MK-A and MK-N with TSB. RESULTS: A total of 144 neonates with median gestation of 37 wk and mean birth weight of 2788 g were enrolled. Bland Altman analysis between Kramer's and TSB yielded mean difference of 1.7 mg/dL, 95% limits of agreement (LOA) -3.1 to 6.6 mg/dL. For Modified Kramer's and TSB, mean difference was -0.02 mg/dL, 95% LOA -4.7 to 4.7 mg/dL under artificial light; 0.02 mg/dL, 95% LOA -4.2 to 4.2 mg/dL under natural daylight. MK-N had highest proportion of bilirubin estimates lying within ±2 mg/dL of TSB (68.7%) as compared to MK-A (59.7%) [OR, 1.77; 95% CI, 1.09 to 2.86] and Kramer's (45.8%) [OR, 1.65; 95% CI, 1.27 to 2.15]. CONCLUSIONS: Though all the three methods had poor agreement with TSB, Modified Kramer's method when performed in natural light had reasonable accuracy, however limited clinical utility, in evaluation of clinical jaundice.

12.
Plant Dis ; : PDIS11222669RE, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-37822103

RESUMEN

Phony peach disease (PPD), found predominantly in central and southern Georgia, is a re-emerging disease caused by Xylella fastidiosa (Xf) subsp. multiplex. Accurate detection and rapid removal of symptomatic trees are crucial to effective disease management. Currently, peach producers rely solely on visual identification of symptoms to confirm PPD, which can be ambiguous if early in development. We compared visual assessment to quantitative PCR (qPCR) for detecting Xf in 'Julyprince' in 2019 and 2020 (JP2019 and JP2020) and in 'Scarletprince' in 2020 (SP2020). With no prior knowledge of qPCR results, all trees in each orchard were assessed by a cohort of five experienced and five inexperienced raters in the morning and afternoon. Visual identification accuracy of PPD was variable, but experienced raters were more accurate when identifying PPD trees. In JP2019, the mean rater accuracy for experienced and inexperienced raters was 0.882 and 0.805, respectively. For JP2020, the mean rater accuracy for experienced and inexperienced raters was 0.914 and 0.816, respectively. For SP2020, the mean rater accuracy for experienced and inexperienced raters was 0.898 and 0.807, respectively. All raters had false positive (FP) and false negative (FN) observations, but experienced raters had significantly lower FN rates compared with the inexperienced group. Almost all raters overestimated the incidence of PPD in the orchards. Reliability of visual assessments was demonstrated as moderate to good, regardless of experience. Further research is needed to develop accurate and reliable methods of detection to aid management of PPD as both FPs and FNs are costly to peach production.

13.
MethodsX ; 11: 102455, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38023320

RESUMEN

Evaluation of landscape visual quality is crucial for policymaking and planning but is still challenging. A wide range of visual assessment protocols is available, but there is still no consensus on appropriate indicators or approaches. Also, evaluation protocols can encompass many indicators, being exhaustive and complex and making the evaluation lengthy. Furthermore, protocols tend to be catered to a particular type of landscape or site-specific, and it can be tricky to ensure the protocol developed is adequate for the landscape under study. This paper proposes a methodology to optimise the selection of indicators for landscape visual assessments. There are two main goals: i) reduce the evaluation time to avoid respondent fatigue, and ii) make the protocol site-specific, choosing indicators that perform better and avoiding redundant indicators. •The presented method optimises the selection of indicators in expert visual assessments;•Indicators are rated in situ on a 5-point scale and go through a performance and redundancy test;•It helps to adapt complex evaluation protocols to the study landscape and to choose robust indicators in a supported and scientific way.

14.
Sensors (Basel) ; 23(15)2023 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-37571608

RESUMEN

Three-dimensional measurement is a high-throughput method that can record a large amount of information. Three-dimensional modelling of plants has the possibility to not only automate dimensional measurement, but to also enable visual assessment to be quantified, eliminating ambiguity in human judgment. In this study, we have developed new methods that could be used for the morphological analysis of plants from the information contained in 3D data. Specifically, we investigated characteristics that can be measured by scale (dimension) and/or visual assessment by humans. The latter is particularly novel in this paper. The characteristics that can be measured on a scale-related dimension were tested based on the bounding box, convex hull, column solid, and voxel. Furthermore, for characteristics that can be evaluated by visual assessment, we propose a new method using normal vectors and local curvature (LC) data. For these examinations, we used our highly accurate all-around 3D plant modelling system. The coefficient of determination between manual measurements and the scale-related methods were all above 0.9. Furthermore, the differences in LC calculated from the normal vector data allowed us to visualise and quantify the concavity and convexity of leaves. This technique revealed that there were differences in the time point at which leaf blistering began to develop among the varieties. The precise 3D model made it possible to perform quantitative measurements of lettuce size and morphological characteristics. In addition, the newly proposed LC-based analysis method made it possible to quantify the characteristics that rely on visual assessment. This research paper was able to demonstrate the following possibilities as outcomes: (1) the automation of conventional manual measurements, and (2) the elimination of variability caused by human subjectivity, thereby rendering evaluations by skilled experts unnecessary.


Asunto(s)
Imagenología Tridimensional , Lactuca , Lactuca/crecimiento & desarrollo , Simulación por Computador
15.
Quant Imaging Med Surg ; 13(8): 4806-4815, 2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37581034

RESUMEN

Background: 18F-florbetaben (FBB) positron emission tomography (PET) scan has been widely used in research and routine clinical practice. Most studies used late-phase (scanning from 90 to 110 min after injection) FBB scans to generate beta-amyloid accumulation data. The feasibility of middle-phase scan is seldom discussed. Using the middle-phase data can shorten the patients' waiting between the injection and scan, and hospital can acquire more flexible schedule of routine scan. Methods: Paired middle-phase (60-80 min) FBB scans and standard (90-110 min) FBB scans were obtained from 27 subjects (12 neurodegenerative dementia, 8 mild cognitive impairment, 3 normal control, and 4 patients not suffering from neurodegenerative dementia). Standardized uptake value ratios (SUVRs) were calculated and converted to centiloid (CL) scale to investigate the impact on image quantification. CL pipeline validation were performed to build an equation converting the middle-phase data into equivalent standard scans. Cohen's kappa of binary interpretation and brain amyloid plaque load (BAPL) score were also used to evaluate the intrareader agreement of the FBB image from the two protocols. Results: The middle-phase FBB SUVR showed an excellent correlation, which provided a linear regression equation of SUVRFBB60-80 = 0.88 × SUVRFBB90-110 + 0.07, with R2=0.98. The slope of the equation indicated that there was bias between the middle and standard acquisition. This can be converted into the CL scale using CL = 174.68 × SUVR - 166.39. Cohen's kappa of binary interpretation and BAPL score were 1.0 (P<0.0001). Conclusions: Our findings indicate that the middle-phase FBB protocol is feasible in clinical applications for scans that are at either end of beta-amyloid spectrum, which provides comparable semiquantitative results to standard scan. Patient's waiting time between the injection and scan can be shortened.

16.
Skin Res Technol ; 29(7): e13407, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37522508

RESUMEN

BACKGROUND: Skin dullness has long been a major concern of Japanese women. It is usually evaluated and judged visually by experts. Although several factors are recognized to play a role, it is unclear to what extent such physiological characteristics contribute to skin dullness. The purpose of this study is to establish an objective method for evaluation, which will assist in developing cosmetics products targeting skin dullness. METHODS: We conducted a skin measurement study on 50 Japanese women in their 30-50s, where skin dullness was visually assessed by a group of experts to obtain an average dullness score, and several skin parameters were obtained. We then developed a regression model that explains the visual assessment score using these physiological parameters. RESULTS: The results of partial least squares analysis of the dullness perception and physiological characteristics showed that skin dullness can be defined by colorimetric, optical, and skin surface microtopography parameters. Additionally, the contribution of each parameter to the model was determined. Our results suggest that dullness perception is highly affected by the melanin content and yellowness of the skin, followed by skin reddishness, roughness, and translucency score, whereas glossiness has less effect. Strikingly, the contribution ratio of each parameter varied among age groups. Furthermore, we confirmed that the predicted value of skin dullness increases with age. CONCLUSION: Our results will help the design of cosmetics targeting factors specific to age groups in developing effective solutions for skin dullness.


Asunto(s)
Cosméticos , Piel , Humanos , Femenino , Piel/diagnóstico por imagen , Colorimetría , Modelos Teóricos , Propiedades de Superficie
17.
J Cardiovasc Echogr ; 33(1): 17-21, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37426720

RESUMEN

Background: The relationship between visual assessment and longitudinal strain during dobutamine stress echocardiography (DSE) remains poorly investigated. This study assessed wall motion segments visually graded as normokinetic, hypokinetic, and akinetic at baseline and the peak of DSE and compared with longitudinal strain between segments with and without induced impaired contractility and improved contractility during DSE. Methods: This study included 112 patients examined by DSE, consisting of 58 patients referred for diagnostic study and 54 patients referred for viability study. Regional left ventricular (LV) contractility was assessed visually and longitudinal strain was measured using echocardiography transthoracic. Results: At baseline, the strain of LV segments was -16.33 ± 6.26 in visually normokinetic, 13.05 ± 6.44 in visually hypokinetic, and -8.46 ± 5.69 in visually akinetic segments. During peak dose, the strain of LV segments was -15.37 ± 6.89 in visually normokinetic, -11.37 ± 5.11 in visually hypokinetic, and -7.37 ± 3.92 in visually akinetic segments. In segments with visually observed impaired contractility, the median longitudinal strain was significantly lower than in segments without impaired contractility. For segments with visually observed improved contractility, the median longitudinal strain was significantly higher than for segments without improved contractility. In diagnostic study, sensitivity of visual assessment for absolute decrease of >2% longitudinal strain was 77%, respectively. In the viability study, the sensitivity was 82% for an absolute decrease of ≥2% longitudinal strain. Conclusions: There is good association between strain analysis value and visually assessed wall motion contractility.

19.
J Pers Med ; 13(4)2023 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-37108994

RESUMEN

BACKGROUND: The assessment of breast density is one of the main goals of radiologists because the masking effect of dense fibroglandular tissue may affect the mammographic identification of lesions. The BI-RADS 5th Edition has revised the mammographic breast density categories, focusing on a qualitative evaluation rather than a quantitative one. Our purpose is to compare the concordance of the automatic classification of breast density with the visual assessment according to the latest available classification. METHODS: A sample of 1075 digital breast tomosynthesis images from women aged between 40 and 86 years (58 ± 7.1) was retrospectively analyzed by three independent readers according to the BI-RADS 5th Edition. Automated breast density assessment was performed on digital breast tomosynthesis images with the Quantra software version 2.2.3. Interobserver agreement was assessed with kappa statistics. The distributions of breast density categories were compared and correlated with age. RESULTS: The agreement on breast density categories was substantial to almost perfect between radiologists (κ = 0.63-0.83), moderate to substantial between radiologists and the Quantra software (κ = 0.44-0.78), and the consensus of radiologists and the Quantra software (κ = 0.60-0.77). Comparing the assessment for dense and non-dense breasts, the agreement was almost perfect in the screening age range without a statistically significant difference between concordant and discordant cases when compared by age. CONCLUSIONS: The categorization proposed by the Quantra software has shown a good agreement with the radiological evaluations, even though it did not completely reflect the visual assessment. Thus, clinical decisions regarding supplemental screening should be based on the radiologist's perceived masking effect rather than the data produced exclusively by the Quantra software.

20.
Eur J Neurol ; 30(6): 1639-1647, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36915220

RESUMEN

BACKGROUND: Nigrosome 1 (NG1), a small cluster of dopaminergic cells in the substantia nigra and visible in the susceptibility map-weighted magnetic resonance image (SMwI), is severely affected in Parkinson's disease (PD). However, the degree of nigrostriatal degeneration according to the visibility of NG1 has not yet been well elucidated. METHODS: We consecutively recruited 138 PD and 78 non-neurodegenerative disease (non-ND) patients, who underwent both 18 F-FP-CIT positron emission tomography (PET) and SMwI. Three neurologists and one radiologist evaluated the visibility of NG1 in SMwI. The participants were thereby grouped into visible, intermediate, and non-visible groups. Nigrostriatal dopaminergic input was calculated using the specific binding ratio (SBR) of the 18 F-FP-CIT PET. We determined the threshold of regional SBR for discriminating NG1 visibility and the probability for NG1 visibility according to regional SBR. RESULTS: Visual rating of NG1 showed excellent interobserver agreements as well as high sensitivity and specificity to differentiate the PD group from the non-ND group. NG1 was visible in seven patients (5.1%) in the PD group, who had relatively short disease duration or less severe loss of striatal dopamine. The threshold of putaminal SBR reduction on the more affected side for the disappearance of NG1 was 45.5%, and the probability for NG1 visibility dropped to 50% after the reduction of putaminal SBR to 41% from the normal mean. CONCLUSIONS: Almost half loss of nigrostriatal dopaminergic input is required to dissipate the hyperintensity of NG1 on SMwI, suggesting its utility in diagnosing PD only after the onset of the motor symptoms.


Asunto(s)
Enfermedad de Parkinson , Humanos , Enfermedad de Parkinson/complicaciones , Dopamina/metabolismo , Tropanos/metabolismo , Tomografía de Emisión de Positrones/métodos , Cuerpo Estriado/diagnóstico por imagen , Cuerpo Estriado/metabolismo , Tomografía Computarizada de Emisión de Fotón Único/métodos , Sustancia Negra/diagnóstico por imagen , Sustancia Negra/metabolismo , Proteínas de Transporte de Dopamina a través de la Membrana Plasmática/metabolismo